711 resultados para percutaneous interventions
Resumo:
Percutaneous needle intervention based on PET/CT images is effective, but exposes the patient to unnecessary radiation due to the increased number of CT scans required. Computer assisted intervention can reduce the number of scans, but requires handling, matching and visualization of two different datasets. While one dataset is used for target definition according to metabolism, the other is used for instrument guidance according to anatomical structures. No navigation systems capable of handling such data and performing PET/CT image-based procedures while following clinically approved protocols for oncologic percutaneous interventions are available. The need for such systems is emphasized in scenarios where the target can be located in different types of tissue such as bone and soft tissue. These two tissues require different clinical protocols for puncturing and may therefore give rise to different problems during the navigated intervention. Studies comparing the performance of navigated needle interventions targeting lesions located in these two types of tissue are not often found in the literature. Hence, this paper presents an optical navigation system for percutaneous needle interventions based on PET/CT images. The system provides viewers for guiding the physician to the target with real-time visualization of PET/CT datasets, and is able to handle targets located in both bone and soft tissue. The navigation system and the required clinical workflow were designed taking into consideration clinical protocols and requirements, and the system is thus operable by a single person, even during transition to the sterile phase. Both the system and the workflow were evaluated in an initial set of experiments simulating 41 lesions (23 located in bone tissue and 18 in soft tissue) in swine cadavers. We also measured and decomposed the overall system error into distinct error sources, which allowed for the identification of particularities involved in the process as well as highlighting the differences between bone and soft tissue punctures. An overall average error of 4.23 mm and 3.07 mm for bone and soft tissue punctures, respectively, demonstrated the feasibility of using this system for such interventions. The proposed system workflow was shown to be effective in separating the preparation from the sterile phase, as well as in keeping the system manageable by a single operator. Among the distinct sources of error, the user error based on the system accuracy (defined as the distance from the planned target to the actual needle tip) appeared to be the most significant. Bone punctures showed higher user error, whereas soft tissue punctures showed higher tissue deformation error.
Resumo:
OBJECTIVE: To assess the feasibility and safety of coronary interventions performed through the radial artery. METHODS: We studied 103 patients with ages from 38 to 86 years (57±8.7), 90 (87%) males, and: radial pulse with a good amplitude, presence of ulnar pulse, a good collateral flow through the palmar arch assessed with the Allen's test. RESULTS: The vascular approach was obtained in 97 (94%) patients, 88 (91%) treated electively and 9 (9%) during acute myocardial infarction, for primary angioplasty; 56 (64%) unstable angina; 22 (25%) stable angina; 10 (11%) were asymptomatic, 6 referred for recanalization of chronic occlusion and 4 silent ischemia in the first week after acute myocardial infarction. We approached 107 arteries: anterior descending artery, 49 (46%); right coronary artery, 27 (25%); circumflex artery, 25 (23%); diagonal artery, 6 (6%); and 2 saphenous vein bypass grafts. We treated 129 lesions: 80 (62%) B2 type; 23 (18%) B1 type; 17 (13%) C type; and 9 (7%). A type. There were 70 stents , and 59 balloon angioplasties performed. Thirty-two (33%) patients used GP IIb/IIIa inhibitors. The mean duration of the elective procedure was 42.3±12.8 min. Success, correct stent deployment and residual lesion <20%, was reached in 100% of the lesions treated with stent implantation; arterial dilation with residual lesion <50% was obtained in 96% of the lesions treated with transluminal coronary angioplasty (TCA). Complications, were: 1 (1.0%) non-Q-wave acute myocardial infarction; 2 (2%) hematomas in the forearm; and 2 losses of radial pulse. CONCLUSION: Radial artery aproach is practical and safe for percutaneous coronary interventions there was a low incidence of complications.
Resumo:
Positron emission tomography-computed tomography (PET-CT) has gained widespread acceptance as a staging investigation in the diagnostic workup of malignant tumours and may be used to visualize metabolic changes before the evolution of morphological changes. To make histology of PET findings without distinctive structural changes available for treatment decisions, we developed a protocol for multimodal image-guided interventions using an integrated PET-CT machine. We report our first experience in 12 patients admitted for staging and restaging of breast cancer, non-small cell lung cancer, cervical cancer, soft tissue sarcoma, and osteosarcoma. Patients were repositioned according to the findings in PET-CT and intervention was planned based on a subsequent single-bed PET-CT acquisition of the region concerned. The needle was introduced under CT guidance in a step-by-step technique and correct needle position in the centre of the FDG avid lesion was assured by repetition of a single-bed PET-CT acquisition before sampling. The metabolically active part of lesions was accurately targeted in all patients and representative samples were obtained in 92%. No major adverse effects occurred. We conclude that PET-CT guidance for interventions is feasible and may be promising to optimize the diagnostic yield of CT-guided interventions and to make metabolically active lesions without morphological correlate accessible to percutaneous interventions.
Resumo:
The Ross procedure has been used in children and young adults for aortic valve replacement and the correction of complex obstruction syndromes of the left ventricular outflow tract. We report the mid-term results of the Ross procedure in a single institution and performed by the same surgical team. Population: Between March 1999 and December 2005, 18 patients were operated on using the Ross procedure. The mean age at the time of surgery was 12 years, being 12 patients male (67%). The primary indication for surgery was isolated aortic valve disease, being the predominant abnormality in 58% of cases aortic regurgitation and in 42% left ventricular outflow tract obstruction. Associated lesions included sub-aortic membrane in 3 patients (16%), small VSD in 2 patients (11%), bicuspid aortic valve in 4 patients (22%) and severe left ventricular dysfunction and mitral valve regurgitation in 1 patient (6%). Ten of the 18 patients (56%) had been submitted to previous surgical procedures or percutaneous interventions. Results: Early post-operative mortality was not seen, but two patients (11%), had late deaths, one due to endocarditis, a year after the Ross procedure, and the other due to dilated cardiomiopathy and mitral regurgitation. The shortest time of follow-up is 6 months and the longest 72 months (median 38 months). Of the 16 survivors, 14 patients are in class I of the NYHA and 2 in class II, without significant residual lesions or need for re-intervention. The 12 patients with more than a year of follow up revealed normal coronary perfusion in all patients and no segmental wall motion abnormalities. Nevertheless, two of the 12 patients developed residual dynamic obstruction of LVOT and in three patients aortic regurgitation of a mild to moderate degree was evident. Significant gradients were not verified in the RVOT. Conclusions: The Ross procedure, despite its complexity, can be undertaken with excellent immediate results. Aspects such as the dilation of the neo aortic root and homograft evolution can not be considered in a study of this nature, seeing that the mean follow up time does not exceed 5 years.
Resumo:
A woman aged 98 years entered the tertiary hospital service with a picture of acute myocardial infarction of the extensive anterior wall, which began 4 hours earlier. Due to the large myocardial risk area suggested by the electrocardiogram, the patient was taken to the hemodynamics laboratory for the performance of emergency coronary arteriography, which revealed occlusion in the proximal third of the anterior descending artery. Primary angioplasty followed by stent grafting was successfully performed. The patient had a satisfactory evolution (Killip I) and was discharged from the hospital on the seventh postinfarction day. We discuss here aspects of thrombolysis and coronary percutaneous interventions in the aged.
Resumo:
OBJECTIVE: To verify the results after the performance of primary coronary angioplasty in Brazil in the last 4 years. METHODS: During the first 24 hours of acute myocardial infarction onset, 9,434 (12.2%) patients underwent primary PTCA. We analyzed the success and occurrence of major in-hospital events, comparing them over the 4-year period. RESULTS: Primary PTCA use increased compared with that of all percutaneous interventions (1996=10.6% vs. 2000=13.1%; p<0.001). Coronary stent implantation increased (1996=20% vs. 2000=71.9%; p<0.001). Success was greater (1998=89.5% vs. 1999=92.5%; p<0.001). Reinfarction decreased (1998=3.9% vs. 99=2.4% vs. 2000=1.5%; p<0.001) as did emergency bypass surgery (1996=0.5% vs. 2000=0.2%; p=0.01). In-hospital deaths remained unchanged (1996=5.7% vs. 2000=5.1%, p=0.53). Balloon PTCA was one of the independent predictors of a higher rate of unsuccessful procedures (odds ratio 12.01 [CI=95%] 1.58-22.94), and stent implantation of lower mortality rates (odds ratio 4.62 [CI=95%] 3.19-6.08). CONCLUSION: The success rate has become progressively higher with a significant reduction in reinfarction and urgent bypass surgery, but in-hospital death remains nearly unchanged. Coronary stenting was a predictor of a lower death rate, and balloon PTCA was associated with greater procedural failure.
Resumo:
Interventional paediatric and congenital cardiology is expanding at a rapid pace. Validated techniques (such as aortic or pulmonary valve dilatations and occlusion of persistent ductus arteriosus and atrial septal defects) are improving thanks to the use of smaller introducers and sheaths, low-profile balloons and novel devices. Moreover, catheter-based interventions have emerged as an attractive alternative to surgery in other fields: pulmonary valve replacement, balloon and stent implantation for native and recurrent coarctation, and percutaneous closure of ventricular septal defects. On the other hand, percutaneous interventions in the paediatric population may be limited by patient size or the anatomy of the defect. Hybrid approaches involving both cardiac interventionists and surgeons are being developed to overcome these limitations. Based on a better understanding of cardiac development, fetal cardiac interventions are being attempted in order to alter the history of severe obstructive lesions. Finally, some interventional procedures still carry a low success rate-for example, pulmonary vein stenosis, even with the use of conventional stents. Biodegradable stents and devices are being developed and may find an application in this setting as well as in others. The purpose of this review is to highlight the advances in paediatric interventional cardiology since the beginning of the third millennium.
Resumo:
PET/CT guidance for percutaneous interventions allows biopsy of suspicious metabolically active bone lesions even when no morphological correlation is delineable in the CT images. Clinical use of PET/CT guidance with conventional step-by-step technique is time consuming and complicated especially in cases in which the target lesion is not shown in the CT image. Our recently developed multimodal instrument guidance system (IGS) for PET/CT improved this situation. Nevertheless, bone biopsies even with IGS have a trade-off between precision and intervention duration which is proportional to patient and personnel exposure to radiation. As image acquisition and reconstruction of PET may take up to 10 minutes, preferably only one time consuming combined PET/CT acquisition should be needed during an intervention. In case of required additional control images in order to check for possible patient movements/deformations, or to verify the final needle position in the target, only fast CT acquisitions should be performed. However, for precise instrument guidance accounting for patient movement and/or deformation without having a control PET image, it is essential to be able to transfer the position of the target as identified in the original PET/CT to a changed situation as shown in the control CT.
Resumo:
This prospective study evaluated the effect of an individualized, comprehensive, home-based cardiac rehabilitation program combining exercise training with risk factor modification and psychosocial counseling on risk factors, psychological wellbeing, functional capacity, and work resumption in 99 post-percutaneous coronary interventions (PCI) patients randomized to control (standard care plus telephone follow-up, n = 49) or intervention (individualized, comprehensive, home-based cardiac rehabilitation, n = 50) groups. Data were collected at time 1 (T-1) during hospital admission, time 2 (T-2) approximately 2 months post-PCI, and time 3 (T-3) approximately 12 months post-PCI. Results suggest that the allocation to an individualized, comprehensive, home-based cardiac rehabilitation program provided more advantageous outcomes. At both follow-ups, the intervention group showed within-group improvement in serum cholesterol levels (P < 0.02; P < 0.01) and exercise participation (P < 0.001; P < 0.001) with differences in exercise participation favoring the intervention group (P < 0.01) at T-2 Repeated measures ANOVA showed significant improvements over time in body mass index (BMI) (P < 0.01), psychological well-being (P < 0.001), and functional capacity (P < 0.001) for both groups. More patients in the intervention group had returned to work at T-2 (P < 0.001) and did so more quickly (P < 0.01). These findings suggest that an individualized, comprehensive, home-based cardiac rehabilitation program improves risk factor profiles and work resumption patterns for patients following PCI. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
Resumo:
OBJECTIVES: This study aimed to characterize myocardial infarction after percutaneous coronary intervention (PCI) based on cardiac marker elevation as recommended by the new universal definition and on the detection of late gadolinium enhancement (LGE) by cardiovascular magnetic resonance (CMR). It is also assessed whether baseline inflammatory biomarkers are higher in patients developing myocardial injury. BACKGROUND: Cardiovascular magnetic resonance accurately assesses infarct size. Baseline C-reactive protein (CRP) and neopterin predict prognosis after stent implantation. METHODS: Consecutive patients with baseline troponin (Tn) I within normal limits and no LGE in the target vessel underwent baseline and post-PCI CMR. The Tn-I was measured until 24 h after PCI. Serum high-sensitivity CRP and neopterin were assessed before coronary angiography. RESULTS: Of 45 patients, 64 (53 to 72) years of age, 33% developed LGE with infarct size of 0.83 g (interquartile range: 0.32 to 1.30 g). A Tn-I elevation >99% upper reference limit (i.e., myocardial necrosis) (median Tn-I: 0.51 μg/l, interquartile range: 0.16 to 1.23) and Tn-I > 3× upper reference limit (i.e., type 4a myocardial infarction [MI]) occurred in 58% and 47% patients, respectively. LGE was undetectable in 42% and 43% of patients with periprocedural myocardial necrosis and type 4a MI, respectively. Agreement between LGE and type 4a MI was moderate (kappa = 0.45). The levels of CRP or neopterin did not significantly differ between patients with or without myocardial injury, detected by CMR or according to the new definition (p = NS). CONCLUSIONS: This study reports the lack of substantial agreement between the new universal definition and CMR for the diagnosis of small-size periprocedural myocardial damage after complex PCI. Baseline levels of CRP or neopterin were not predictive for the development of periprocedural myocardial damage.
Resumo:
BACKGROUND AND AIM OF THE STUDY: Percutaneous coronary interventions (PCI) are frequently performed before coronary artery bypass graft (CABG) surgery. This study sought to evaluate postoperative outcomes, and incidence of recurrent target ischemia in vessels with prior PCI in patients who had PCI prior to CABG compared to only CABG patients. METHODS: A review included CABG patients operated from 2000 to 2012. PCI prior to CABG patients were compared with patients having had CABG on native coronary arteries. Demographic and risk factors, including hospital morbidity, mortality, and recurrent target vessel ischemia at follow-up (FU), were compared. Major end-points were statistical differences of postoperative morbidity and reintervention rates due to symptomatic graft failure or target vessel ischemia during FU. RESULTS: Twenty-four percent of 1669 isolated CABG patients had PCI prior to CABG, with an increasing percentage during recent years. Demographics, risk factors, comorbidities and mortality rates were similar. Incidence of postoperative hemorrhage (OR 1.9; 95% CI 1.1-3.2; p = 0.02), perioperative myocardial infarction rate (p = 0.02), neurological deficits (OR 3.5; 95% CI 1.2-9.7; p = 0.02) and re-intervention rate for symptomatic graft or target vessel occlusion were higher in pretreated patients (OR 1.8; 95% CI 1.1-3.0; p = 0.01). CONCLUSIONS: PCI prior to CABG increases the risk for postoperative morbidity. Increased postoperative hemorrhage could be attributed to ongoing double anti-platelet therapy. doi: 10.1111/jocs.12514 (J Card Surg 2015;30:313-318).
Resumo:
This registry has aimed to collect data on cardiac catheterisation procedures in Europe in 2006.
Resumo:
To investigate the ability of SYNTAX score and Clinical SYNTAX score (CSS) to predict very long-term outcomes in an all-comers population receiving drug-eluting stents.
Resumo:
The purpose of this study was to assess the impact of body mass index (BMI) on clinical outcome of patients treated by percutaneous coronary intervention (PCI) using drug-eluting stents. Patients were stratified according to BMI as normal (<25 kg/m(2)), overweight (25 to 30 kg/m(2)), or obese (>30 kg/m(2)). At 5-year follow-up all-cause death, myocardial infarction, clinically justified target vessel revascularization (TVR), and definite stent thrombosis were assessed. A complete dataset was available in 7,427 patients, of which 45%, 22%, and 33% were classified according to BMI as overweight, obese, and normal, respectively. Mean age of patients was significantly older in those with a normal BMI (p <0.05). Incidence of diabetes mellitus, hypertension, and dyslipidemia increased as BMI increased (p <0.05). Significantly higher rates of TVR (15.3% vs 12.8%, p = 0.02) and early stent thrombosis (1.5% vs 0.9%, p = 0.04) were observed in the obese compared to the normal BMI group. No significant difference among the 3 BMI groups was observed for the composite of death/myocardial infarction/TVR or for definite stent thrombosis at 5 years, whereas the normal BMI group was at higher risk for all-cause death at 5 years (obese vs normal BMI, hazard ratio 0.74, confidence interval 0.53 to 0.99, p = 0.05; overweight vs normal BMI, hazard ratio 0.73, confidence interval 0.59 to 0.94, p = 0.01) in the multivariate Cox proportional hazard model. Age resulted in a linearly dependent covariate with BMI in the all-cause 5-year mortality multivariate model (p = 0.001). In conclusion, the "obesity paradox" observed in 5-year all-cause mortality could be explained by the higher rate of elderly patients in the normal BMI group and the existence of colinearity between BMI and age. However, obese patients had a higher rate of TVR and early stent thrombosis and a higher rate of other risk factors such as diabetes mellitus, hypertension, and hypercholesterolemia.