Multimodal target correction by local bone registration: a PET/CT evaluation


Autoria(s): Oliveira-Santos, Thiago; Weitzel, Thilo; Klaeser, Bernd; Krause, Thomas; Nolte, Lutz-Peter; Weber, Stefan; Reyes, Mauricio
Data(s)

2010

Resumo

PET/CT guidance for percutaneous interventions allows biopsy of suspicious metabolically active bone lesions even when no morphological correlation is delineable in the CT images. Clinical use of PET/CT guidance with conventional step-by-step technique is time consuming and complicated especially in cases in which the target lesion is not shown in the CT image. Our recently developed multimodal instrument guidance system (IGS) for PET/CT improved this situation. Nevertheless, bone biopsies even with IGS have a trade-off between precision and intervention duration which is proportional to patient and personnel exposure to radiation. As image acquisition and reconstruction of PET may take up to 10 minutes, preferably only one time consuming combined PET/CT acquisition should be needed during an intervention. In case of required additional control images in order to check for possible patient movements/deformations, or to verify the final needle position in the target, only fast CT acquisitions should be performed. However, for precise instrument guidance accounting for patient movement and/or deformation without having a control PET image, it is essential to be able to transfer the position of the target as identified in the original PET/CT to a changed situation as shown in the control CT.

Formato

application/pdf

application/pdf

Identificador

http://boris.unibe.ch/2868/1/OliveiraEMBC2010b.pdf

http://boris.unibe.ch/2868/2/05626797.pdf

Oliveira-Santos, Thiago; Weitzel, Thilo; Klaeser, Bernd; Krause, Thomas; Nolte, Lutz-Peter; Weber, Stefan; Reyes, Mauricio (2010). Multimodal target correction by local bone registration: a PET/CT evaluation. IEEE Engineering in Medicine and Biology Society conference proceedings, 2010, pp. 5616-5619. Piscataway, N.J.: IEEE Service Center 10.1109/IEMBS.2010.5626797 <http://dx.doi.org/10.1109/IEMBS.2010.5626797>

doi:10.7892/boris.2868

info:doi:10.1109/IEMBS.2010.5626797

info:pmid:21096492

urn:issn:1557-170X

Idioma(s)

eng

Publicador

IEEE Service Center

Relação

http://boris.unibe.ch/2868/

Direitos

info:eu-repo/semantics/restrictedAccess

info:eu-repo/semantics/restrictedAccess

Fonte

Oliveira-Santos, Thiago; Weitzel, Thilo; Klaeser, Bernd; Krause, Thomas; Nolte, Lutz-Peter; Weber, Stefan; Reyes, Mauricio (2010). Multimodal target correction by local bone registration: a PET/CT evaluation. IEEE Engineering in Medicine and Biology Society conference proceedings, 2010, pp. 5616-5619. Piscataway, N.J.: IEEE Service Center 10.1109/IEMBS.2010.5626797 <http://dx.doi.org/10.1109/IEMBS.2010.5626797>

Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed