1000 resultados para perchloric acid
Resumo:
A simple, rapid and inexpensive method for the determination of sparfloxacin in tablets is described. The procedure is based on the use of volumetric dosage in a nonaqueous medium in glacial acetic acid with 0.1 M perchloric acid. The method validation yielded good results and included precision and accuracy. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Resumo:
An inexpensive, simple, precise and rapid method for the determination of fluoroquinolone gatifloxacin in tablets is described. The procedure is based on the use of volumetric dosage in a non-aqueous medium in glacial acetic acid with 0.1 M perchloric acid. The method validation yielded good results and included the precision, recovery and accuracy. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay.
Resumo:
An efficient aza-Michael addition of amines to a series of ,-unsaturated ketones, carboxylic esters, nitriles and chalcones has been carried out using perchloric acid supported over silica gel (HClO4-SiO2) at room temperature in high yields under solvent-free reaction conditions.
Resumo:
Mode of access: Internet.
Resumo:
The objective of this work was to evaluate the accuracy of digestion techniques using nitric and perchloric acid at the ratios of 2:1, 3:1, and 4:1 v v-1, in one- or two-step digestion, to estimate chromium contents in cattle feces, using sodium molybdate as a catalyst. Fecal standards containing known chromium contents (0, 2, 4, 6, 8, and 10 g kg-1) were produced from feces of five animals. The chromium content in cattle feces is accurately estimated using digestion techniques based on nitric and perchloric acids, at a 3:1 v v-1 ratio, in one-step digestion, with sodium molybdate as a catalyst.
Resumo:
Ethanol oxidation has been studied on Pt(111), Pt(100) and Pt(110) electrodes in order to investigate the effect of the surface structure and adsorbing anions using electrochemical and FTIR techniques. The results indicate that the surface structure and anion adsorption affect significantly the reactivity of the electrode. Thus, the main product of the oxidation of ethanol on the Pt(111) electrode is acetic acid, and acetaldehyde is formed as secondary product. Moreover, the amount of CO formed is very small, and probably associated with the defects present on the electrode surface. For that reason, the amount of CO(2) is also small. This electrode has the highest catalytic activity for the formation of acetic acid in perchloric acid. However, the formation of acetic acid is inhibited by the presence of specifically adsorbed anions, such as (bi) sulfate or acetate, which is the result of the formation of acetic acid. On the other hand, CO is readily formed at low potentials on the Pt(100) electrode, blocking completely the surface. Between 0.65 and 0.80 V, the CO layer is oxidized and the production of acetaldehyde and acetic acid is detected. The Pt(110) electrode displays the highest catalytic activity for the splitting of the C-C bond. Reactions giving rise to CO formation, from either ethanol or acetaldehyde, occur at high rate at any potential. On the other hand, the oxidation of acetaldehyde to acetic acid has probably the lower reaction rate of the three basal planes.
Resumo:
A new approach to electrochromics, based on the reversible coating-dissolution of an oxide from an inorganic electrochromic electrolyte consisting of a silver-amine complex in a polymer electrolyte (PEO), has proven successful. The reversible electrodeposition of silver onto indium-tin oxide coated glass (ITO) was investigated and the influence of HClO(4) and KI was evaluated. Several characteristics of the electrolyte Ag-PEO make it suitable for use in electrochromic reversible silver electrodeposition devices, such as visible absorption spectrum with an absorbance variation of 60%, an electrochromic efficiency of 5.2 cm(2) C(-1) and an ionic conductivity 4.4 x 10(-4) S cm(-1). The addition of perchloric acid improved the transparency of Ag-PEO, and potassium iodide (KI) was fundamental in setting up the process of reversible silver electrodeposition in the PEO polymeric matrix. A description of the electrochemical processes implied is presented. A number of approaches focusing on the improvement of system performance are tested. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
An analytical procedure for the determination of Hg in otter (Lontra longicaudis) feces was developed, to separate fish scales for the identification of the animal diet. Samples were washed with ultra-pure water and the suspension was sampled and transferred for digestion. The solubilization was performed with nitric-perchloric acid mixture, and detection carried out by the atomic fluorescence spectrometry (AFS). The quality of the analytical procedure was assessed by analyzing in-house standard solutions and certified reference materials. Total Hg concentrations were in the range of 7.6-156 ng g(-1) (July 2004), 25.6-277 ng g(-1) (January 2005) and 14.6-744 ng g(-1) (May 2005) that is approximately the same order of magnitude for all samples collected in two reservoirs at the Tiete River, Brazil. Although Hg concentrations varied with sampling periods and diet, high levels were correlated to the percentage of carnivorous fish scales present in the otter feces. (c) 2007 Elsevier Ltd. All rights reserved.
Resumo:
A method for the simultaneous analysis of the enantiomers of mefloquine (MQ) and its main metabolite carboxymefloquine (CMQ) in plasma is described for the first time. The assay involves two-step liquid-phase micro-extraction (LPME) and enantioselective high-performance liquid chromatography. In the first LPME step, the enantiomers of MQ were extracted from an alkalinized sample through a thin layer of di-n-hexyl ether immobilized in the pores of the hollow fiber and into 0.01 M perchloric acid as acceptor solution. In the second LPME step, the same sample was acidified to enable the extraction of CMQ using the same organic solvent and 0.05 M sodium hydroxide as acceptor phase. The analytes were resolved on a Chirobiotic T column in the polar-organic mode of elution and detected at 285 nm. The recovery rates from 1 mL of plasma were in the range 35-38%. The method presented limits of quantification of 50 ng/mL for all analytes and was linear up to 1,500 and 3,000 ng/mL for the enantiomers of MQ and CMQ, respectively. The plasmatic concentrations of (+)-(RS)-MQ were higher than those of (-)-(SR)-MQ after oral administration of the racemic drug to rats.
Resumo:
Carcinoembryonic antigen (CEA), immunologically identical to CEA derived from colonic carcinoma, was identified and purified from perchloric acid (PCA) extracts of bronchial and mammary carcinoma. CEA extracted from bronchial and mammary carcinoma was quantitated by single radial immunodiffusion and was found to be in average about 50-75 times less abundant in these tumors than in colonic carcinoma. CEA could also be detected in one normal breast in lactation and at lower concentrations in normal lung (1000-4000 times lower than in colonic carcinoma). The small amounts of CEA present in normal tissues are distinct from the glycoprotein of small mol. wt showing only partial identity with CEA, that we recently identified and extracted in much larger quantities from normal lung and spleen. The demonstration of the presence of CEA in non digestive carcinoma by classical gel precipitation analysis suggests that the CEA detected in the plasma of such patients by radioimmunoassay is also identical to colonic carcinoma CEA. Our comparative study of plasma CEA from bronchial and colonic carcinoma, showing that CEA from both types of patient has the same elution pattern on Sephadex G-200 and gives parallel inhibition curves in the radioimmunoassay, is in favor of this hypothesis. However, it should not be concluded that all positive CEA radioimmunoassay indicate the presence of an antigen identical to colonic carcinoma CEA. A word of warning concerning the interpretation of radioimmunoassay is required by the observation that the addition of mg amounts of PCA extract of normal plasma, cleared of CEA by Sephadex filtration, could interfere in the test and mimic the presence of CEA.
Resumo:
A preliminary study of the pharmacokinetic parameters of t-Butylaminoethyl disulfide was performed after administration of two different single doses (35 and 300 mg/kg) of either the cold or labelled drug. Plasma or blood samples were treated with dithiothreitol, perchloric acid, and, after filtration, submitted to further purification with anionic resein. In the final step, the drug was retained on a cationic resin column, eluted with NaCl 1M and detected according to the method of Ellman (1958). Alternatively, radioactive drug was detected by liquid scintillation counting. The results corresponding to the smaller dose of total drug suggested a pharmacokinetic behavior related to a one open compartment model with the following parameters: area under the intravenous curve (AUC i.v.):671 ± 14; AUC oral: 150 ± 40 µg.min. ml [raised to the power of -1]; elimination rate constant: 0.071 min [raised to the power of -1]; biological half life: 9.8 min; distribution volume: 0.74 ml/g. For the higher dose, the results seemed to obey a more complex undertermined model. Combining the results, the occurence of a dose-dependent pharmacokinetic behavior is suggested, the drug being rapidly absorbed and rapidly eliminated; the elimination process being related mainly to metabolization. The drug seems to be more toxic when administered I.V. because by this route it escapes first pass metabolism, while being quickly distributed to tissues. The maximum tolerated blood level seems to be around 16 µg/ml.
Resumo:
A preliminary study of the pharmacokinetic parameters of t-Butylaminoethanethiol (TBAESH) was performed after administration of a single dose (35 mg/kg) either orally or intravenously. Plasma or blood samples were treated with dithiothreitol, perchloric acid and, after filtration, submitted to further purification with anionic resin. In the final step the drug was retained on a cationic resin column, eluted with NaCl lM and detected according to the method of Ellman (1958). The results suggested a pharmacokinetic behavior related to a one open compartment model with the following values for the total drug: area under the intravenous curve (AUC i.v.): 443(+ ou -) 24.0; AUC oral: 85.5(+ ou -) 14.5 ug min.ml(elevado a -1); elimination rate constant: 0.069(+ ou -) 0.0055 min(elevado a -1), biological half-life: 10.0(+ ou -) 0.80 min; distribution volume 1.15(+ ou -) 0.15 ml/g; biodisponibility: 0.19(+ ou -) 0.02. From a pharmacokinetic standpoint, TBAESH seems to have no advantage over the analogous disulfide compound.
Resumo:
Two new forms of non-specific crossreacting antigens (NCAs) were identified in the Nonidet P40 (NP-40) extracts of normal granulocytes by precipitation with the monoclonal antibody (MAb) 192 directed against carcinoembryonic antigen (CEA) and already known to crossreact with the perchloric acid soluble NCA-55. The NP-40 soluble NCAs recognized by MAb 192 have apparent mol. wts of 90,000 and 160,000 in sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Both NCAs appear to consist of a single monomeric polypeptide chain, since they have the same electrophoretic mobility in SDS-PAGE under reduced and non-reduced conditions. When granulocytes were extracted with perchloric acid instead of NP-40, only the 55,000 mol. wt antigen, corresponding to the previously described NCA-55, was precipitated by MAb 192. Furthermore, it was shown that NCA-55 is not a degradation product of NCA-90 or NCA-160 due to the perchloric acid treatment because exposure to perchloric acid of NCA preparations purified from NP-40 extracts did not change their apparent mol. wts in SDS-PAGE. It was also shown that NCA-160 is not a granulocytic form of CEA because it was not precipitated by the MAb 35 reacting exclusively with CEA. Immunocytochemical studies of granulocytes and macrophages showed that MAb 192 stained both types of cells whereas MAb 47 stained only the granulocytes and MAb 35 none of these cells. In granulocytes both MAbs reacted with antigens associated with granules and also present at the periphery of the nucleus as well as in the Golgi apparatus. The NCA-90 identified by MAb 192 was found by sequential immunodepletion to be antigenically distinct from the NCA-95 precipitated by MAb 47. The epitope recognized by MAb 192 on CEA and NCA molecules appears to be on the peptidic moiety because the antigens deglycosylated by the enzyme Endo F were still precipitated by this MAb. Taken together, the results indicate that MAb 192 identifies two novel forms of NCA (NCA-90 and NCA-160) in NP-40 extracts of granulocytes, which are distinct from CEA and the previously described NCA-55 and NCA-95 identified by MAbs 192 and 47, respectively, in perchloric acid extracts of granulocytes.
Resumo:
Carcinoembryonic antigen (CEA) was identified in perchloric acid (PCA)_extract from normal colon mucosa by 2 immunological criteria: a line of identity in double diffusion and a parallel inhibition curve in radioimmunoassay (RIA), both with reference colon carcinoma-CEA (CEA-Tu). The average concentration of CEA in normal colon mucosa (CEA-No) was 35 times lower than in primary large bowel carcinomas and 230 times lower than in metastatic colon or rectum carcinomas. CEA-No was purified from PCA extracts of normal colon mucosa by Sephadex G-200 filtration and immunoadsorbent columns. Purified CEA-No had quatitatively the same inhibition activity in RIA as the British Standard CEA coded 73/601. Purified CEA-No was labelled with 125I. The percentage of binding of labelled CEA-No to a specific goat anti-CEA-Tu antiserum was similar to that of CEA-Tu. Labelled CEA-No could be used as radioactive tracer in RIA as well as labelled CEA-Tu. The physico-chemical properties of purified CEA-Tu as demonstrated by Sepharose 6 B filtration, SDS Polyacrylamide gel analysis and cesium chloride density gradient, were found to be almost identical to those of reference CEA-Tu. Preliminary results showed that CEA-No and CEA-Tu contained the same types of carbohydrates in similar proportions. A rabbit antiserum against CEA-No was obtained which demonstrated the same specificity as conventional anti-CEA-Tu antisera.
Resumo:
Antisera highly specific for carcinoembryonic antigen (CEA) from New Zealand White rabbits and a goat reacted strongly in antibody binding tests with cultured tumor cell lines, irrespective of the ability of the cell lines to produce CEA. The most reactive were colon carcinoma and melanoma cell lines, the former known to produce CEA and the latter not associated with CEA production. The reactivity was not diminished by absorption with perchloric acid extracts of normal lung or spleen, whereas absoprtion with purified CEA preparations abolished the reactivity. Quantitative absorption studies indicated that reactivity against CEA-producing cell lines could be totally removed by absorption with other CEA-producing lines but not with melanoma cell lines. Reactivity against melanoma cell lines could be completely removed by colon carcinoma cells as well as by melanoma cells. Antisera raised against purified CEA, after absorption with extracts of normal lung, still contained two populations of antibodies, one that binds a newly described antigen cross-reacting with CEA which is present on melanoma cells.