956 resultados para pH meters


Relevância:

70.00% 70.00%

Publicador:

Resumo:

This is the protocol for a review and there is no abstract. The objectives are as follows: Our objective is to determine if there is sufficient evidence to recommend the use of pH testing (the intervention under scrutiny) for verification of correct placement of nasogastric tubes in adults and children. To this end, we will attempt to answer the following questions: 1. In adults and children, is pH testing an effective and safe method for determining whether nasogastric tubes are correctly positioned in the stomach before feeding (or delivery of any fluid) begins? 2. What evidence is there about the risk of adverse events in the case of incorrect placement? For this review, pH testing is defined as: litmus paper, pH indicator test strips, pH meters. These will be tested against other methods used for detecting placement of nasogastric tubes, including visual examination of aspirate, auscultation with insufflation of air, detection of air bubbles in a bowl of water, X-ray, ultrasonography, endoscopy, enzyme analysis of aspirate, capnography, and other methods that do not rely on measurement of pH.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper is aiming to evaluate the effects of different levels of the aluminum on the growth of the Eucalyptus grandis x E. urophylla shoots cultivated in vitro. Evaluations were carried out on pH and chemicals modifications of the culture medium by Geochem program, polyamines contents (putrescine, espermidine e espermine) and acid phosphatase ativity on the shoots. The trial had a totally randomized design with four treatments and four replicates. The treatments were: 0.0, 6.75,13.50 and 27 mg.L -1 of AlCl 3.6H 2. Evaluations were carried out on the 4th, 8th, 12th, 16th, 20th, 24th and 28th day of culture. The addition of the aluminium, in all concentrations, affected the culture medium ionic equilibrium, the morphology of the shoots, reduced the pH on the medium, induced an increase in polyamines content and higher acid phosphatase activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the quest to develop viable designs for third-generation optical interferometric gravitational-wave detectors, one strategy is to monitor the relative momentum or speed of the test-mass mirrors, rather than monitoring their relative position. The most straightforward design for a speed-meter interferometer that accomplishes this is described and analyzed in Chapter 2. This design (due to Braginsky, Gorodetsky, Khalili, and Thorne) is analogous to a microwave-cavity speed meter conceived by Braginsky and Khalili. A mathematical mapping between the microwave speed meter and the optical interferometric speed meter is developed and used to show (in accord with the speed being a quantum nondemolition observable) that in principle the interferometric speed meter can beat the gravitational-wave standard quantum limit (SQL) by an arbitrarily large amount, over an arbitrarily wide range of frequencies . However, in practice, to reach or beat the SQL, this specific speed meter requires exorbitantly high input light power. The physical reason for this is explored, along with other issues such as constraints on performance due to optical dissipation.

Chapter 3 proposes a more sophisticated version of a speed meter. This new design requires only a modest input power and appears to be a fully practical candidate for third-generation LIGO. It can beat the SQL (the approximate sensitivity of second-generation LIGO interferometers) over a broad range of frequencies (~ 10 to 100 Hz in practice) by a factor h/hSQL ~ √W^(SQL)_(circ)/Wcirc. Here Wcirc is the light power circulating in the interferometer arms and WSQL ≃ 800 kW is the circulating power required to beat the SQL at 100 Hz (the LIGO-II power). If squeezed vacuum (with a power-squeeze factor e-2R) is injected into the interferometer's output port, the SQL can be beat with a much reduced laser power: h/hSQL ~ √W^(SQL)_(circ)/Wcirce-2R. For realistic parameters (e-2R ≃ 10 and Wcirc ≃ 800 to 2000 kW), the SQL can be beat by a factor ~ 3 to 4 from 10 to 100 Hz. [However, as the power increases in these expressions, the speed meter becomes more narrow band; additional power and re-optimization of some parameters are required to maintain the wide band.] By performing frequency-dependent homodyne detection on the output (with the aid of two kilometer-scale filter cavities), one can markedly improve the interferometer's sensitivity at frequencies above 100 Hz.

Chapters 2 and 3 are part of an ongoing effort to develop a practical variant of an interferometric speed meter and to combine the speed meter concept with other ideas to yield a promising third- generation interferometric gravitational-wave detector that entails low laser power.

Chapter 4 is a contribution to the foundations for analyzing sources of gravitational waves for LIGO. Specifically, it presents an analysis of the tidal work done on a self-gravitating body (e.g., a neutron star or black hole) in an external tidal field (e.g., that of a binary companion). The change in the mass-energy of the body as a result of the tidal work, or "tidal heating," is analyzed using the Landau-Lifshitz pseudotensor and the local asymptotic rest frame of the body. It is shown that the work done on the body is gauge invariant, while the body-tidal-field interaction energy contained within the body's local asymptotic rest frame is gauge dependent. This is analogous to Newtonian theory, where the interaction energy is shown to depend on how one localizes gravitational energy, but the work done on the body is independent of that localization. These conclusions play a role in analyses, by others, of the dynamics and stability of the inspiraling neutron-star binaries whose gravitational waves are likely to be seen and studied by LIGO.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Senior thesis written for Oceanography 445

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are many methods used to estimate values in places no sampled for construction of contours maps. The aim of this study was to use the methods of interpolation kriging, inverse of the square of the distance and polynomial in the representation of the spatial variability of the pH of the soil in the organic and conventional management in the culture of the coffee plantation. For that, irregular meshes were built for soil sampling in the depth of 0-0,10 meters, totaling 40 points sampling in each area. For gauging of the interpolation methods they were solitary 10% of the total of points, for each area. Initially, the data were appraised through the classic statistics (descriptive and exploratory) and spatial analysis. The method inverse square of the distance and kriging has low error in estimating dados. The method of kriging presented low variation around the average in different managements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, the influence of pH on interfacial energy distributed over the phospholipids-bilayer surface model and the effect of hydrophobicity on coefficient of friction (f) were investigated by using microelectrophoresis. An important clinical implication of deficiency in hydrophobicity is the loss of phospholipids that is readily observed in osteoarthritis joints. This paper establishes the influence of pH on interfacial energy upon an increase f, which might be associated with a decrease of hydrophobicity of the articular surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrotalcites have been synthesised using three different pH solutions to assess the effect of pH on the uptake of arsenate and vanadate. The ability of these hydrotalcites to remove vanadate and arsenate from solution has been determined by ICP-OES. Raman spectroscopy is used to monitor changes in the anionic species for hydrotalcites synthesised at different pH values. The results show a reduction in the concentration of arsenate and vanadate anions that are removed in extremely alkaline solutions. Hydrotalcites containing arsenate and vanadate are stable in solutions up to pH 10. Exposure of these hydrotalcites to higher pH values results in the removal of large percentages of arsenate and vanadate from the hydrotalcite interlayer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stimulated human whole saliva (WS) was used to study the dynamics of papain hydrolysis at defined pH, ionic strength and temperature with the view of reducing an acquired pellicle. A quartz crystal microbalance with dissipation (QCM-D) was used to monitor the changes in frequency due to enzyme hydrolysis of WS films and the hydrolytic parameters were calculated using an empirical model. The morphological and conformational changes of the salivary films before and after enzymatic hydrolysis were characterized by atomic force microscopy (AFM) imaging and grazing angle infrared spectroscopy (GA-FTIR) spectra, respectively. The characteristics of papain hydrolysis of WS films were pH-, ionic strength- and temperature-dependent. The WS films were partially removed by the action of enzyme, resulting thinner and smoother surfaces. The IR data suggested that hydrolysis-induced deformation did not occur onto the remnants salivary films. The processes of papain hydrolysis of WS films can be controlled by properly regulating pH, ionic strength and temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

1. Both dietary magnesium depletion and potassium depletion (confirmed by tissue analysis) were induced in rats which were then compared with rats treated with chlorothiazide (250 mg/kg diet) and rats on a control synthetic diet. 2. Brain and muscle intracellular pH was measured by using a surface coil and [31P]-NMR to measure the chemical shift of inorganic phosphate. pH was also measured in isolated perfused hearts from control and magnesium-deficient rats. Intracellular magnesium status was assessed by measuring the chemical shift of β-ATP in brain. 3. There was no evidence for magnesium deficiency in the chlorothiazide-treated rats on tissue analysis or on chemical shift of β-ATP in brain. Both magnesium and potassium deficiency, but not chlorothiazide treatment, were associated with an extracellular alkalosis. 4. Magnesium deficiency led to an intracellular alkalosis in brain, muscle and heart. Chlorothiazide treatment led to an alkalosis in brain. Potassium deficiency was associated with a normal intracellular pH in brain and muscle. 5. Magnesium depletion and chlorothiazide treatment produce intracellular alkalosis by unknown mechanism(s).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pretreatments of sugarcane bagasse for saccharification using different acid-catalysed imidazolium IL solutions (containing 20% water) at 130 °C for 30 min were investigated. At the same solution pH, pretreatment effectiveness in terms of glucan digestibility, delignification and xylan removal were similar for aqueous 1-butyl-3-methylimidazolium methane sulfonate (BMIMCH3SO3), 1-butyl-3-methylimidazolium methyl sulfate (BMIMCH3SO4), 1-ethyl-3-methylimidazolium chloride (EMIMCl) and 1-butyl-3-methylimidazolium chloride (BMIMCl). Decreasing solution pH of aqueous IL systems from 6.0 to 0.4 increased bagasse delignification and xylan removal, and as a result, improved glucan digestibility. The glucan digestibilities for bagasse samples pretreated by IL solutions with pH ≤ 0.9 were > 90% after 72 h of enzymatic hydrolysis. Without pH adjustment, the effectiveness of these aqueous IL solutions (except BMIMCH3SO3 because of its low natural pH of 0.9) to deconstruct the biomass was poor and the glucan digestibilities of pretreated bagasse samples were < 20%. These results show that pretreatment effectiveness of aqueous imidazolium ILs can simply be estimated from solution pH rather than hydrogen bond basicity (β) of the IL solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a rapid synthesis of gold nanoparticles using hydroquinone as a reducing agent under acidic conditions without the need for precursor seed particles. The nanoparticle formation process is facilitated by the addition of NaOH to a solution containing HAuCl4 and hydroquinone to locally change the pH; this enhances the reducing capability of hydroquinone to form gold nucleation centres, after which further growth of gold can take place through an autocatalytic mechanism. The stability of the nanoparticles is highly dependent on the initial solution pH, and both the concentration of added NaOH and hydroquinone present in solution. The gold nanoparticles were characterized by UV–visible spectroscopy, transmission electron microscopy, Fourier transform infrared spectroscopy, atomic force microscopy, dynamic light scattering, and zeta potential measurements. It was found that under optimal conditions that stable aqueous suspensions of 20 nm diameter nanoparticles can be achieved where benzoquinone, the oxidized product of hydroquinone, acts as a capping agent preventing nanoparticles aggregation.