50 resultados para nucl
Resumo:
On the domain of general assignment games (with possible reservation prices) the core is axiomatized as the unique solution satisfying two consistency principles: projection consistency and derived consistency. Also, an axiomatic characterization of the nucleolus is given as the unique solution that satisfies derived consistency and equal maximum complaint between groups. As a consequence, we obtain a geometric characterization of the nucleolus. Maschler et al. (1979) provide a geometrical characterization for the intersection of the kernel and the core of a coalitional game, showing that those allocations that lie in both sets are always the midpoint of certain bargaining range between each pair of players. In the case of the assignment game, this means that the kernel can be determined as those core allocations where the maximum amount, that can be transferred without getting outside the core, from one agent to his / her optimally matched partner equals the maximum amount that he / she can receive from this partner, also remaining inside the core. We now prove that the nucleolus of the assignment game can be characterized by requiring this bisection property be satisfied not only for optimally matched pairs but also for optimally matched coalitions. Key words: cooperative games, assignment game, core, nucleolus
Resumo:
La période postnatale et l’expérience sensorielle sont critiques pour le développement du système visuel. Les interneurones inhibiteurs exprimant l’acide γ-aminobutyrique (GABA) jouent un rôle important dans le contrôle de l’activité neuronale, le raffinement et le traitement de l’information sensorielle qui parvient au cortex cérébral. Durant le développement, lorsque le cortex cérébral est très susceptible aux influences extrinsèques, le GABA agit dans la formation des périodes critiques de sensibilité ainsi que dans la plasticité dépendante de l’expérience. Ainsi, ce système inhibiteur servirait à ajuster le fonctionnement des aires sensorielles primaires selon les conditions spécifiques d’activité en provenance du milieu, des afférences corticales (thalamiques et autres) et de l’expérience sensorielle. Certaines études montrent que des différences dans la densité et la distribution de ces neurones inhibiteurs corticaux reflètent les caractéristiques fonctionnelles distinctes entre les différentes aires corticales. La Parvalbumine (PV), la Calretinine (CR) et la Calbindine (CB) sont des protéines chélatrices du calcium (calcium binding proteins ou CaBPs) localisées dans différentes sous-populations d’interneurones GABAergiques corticaux. Ces protéines tamponnent le calcium intracellulaire de sorte qu’elles peuvent moduler différemment plusieurs fonctions neuronales, notamment l’aspect temporel des potentiels d’action, la transmission synaptique et la potentialisation à long terme. Plusieurs études récentes montrent que les interneurones immunoréactifs (ir) aux CaBPs sont également très sensibles à l’expérience et à l’activité sensorielle durant le développement et chez l’adulte. Ainsi, ces neurones pourraient avoir un rôle crucial à jouer dans le phénomène de compensation ou de plasticité intermodale entre les cortex sensoriels primaires. Chez le hamster (Mesocricetus auratus), l’énucléation à la naissance fait en sorte que le cortex visuel primaire peut être recruté par les autres modalités sensorielles, telles que le toucher et l’audition. Suite à cette privation oculaire, il y a établissement de projections ectopiques permanentes entre les collicules inférieurs (CI) et le corps genouillé latéral (CGL). Ceci a pour effet d’acheminer l’information auditive vers le cortex visuel primaire (V1) durant le développement postnatal. À l’aide de ce modèle, l’objectif général de ce projet de thèse est d’étudier l’influence et le rôle de l’activité sensorielle sur la distribution et l’organisation des interneurones corticaux immunoréactifs aux CaBPs dans les aires sensorielles visuelle et auditive primaires du hamster adulte. Les changements dans l’expression des CaBPs ont été déterminés d’une manière quantitative en évaluant les profils de distribution laminaire de ces neurones révélés par immunohistochimie. Dans une première expérience, nous avons étudié la distribution laminaire des CaBPs dans les aires visuelle (V1) et auditive (A1) primaires chez le hamster normal adulte. Les neurones immunoréactifs à la PV et la CB, mais non à la CR, sont distribués différemment dans ces deux cortex primaires dédiés à une modalité sensorielle différente. Dans une deuxième étude, une comparaison a été effectuée entre des animaux contrôles et des hamsters énucléés à la naissance. Cette étude montre que le cortex visuel primaire de ces animaux adopte une chimioarchitecture en PV similaire à celle du cortex auditif. Nos recherches montrent donc qu’une suppression de l’activité visuelle à la naissance peut influencer l’expression des CaBPs dans l’aire V1 du hamster adulte. Ceci suggère également que le type d’activité des afférences en provenance d’autres modalités sensorielles peut moduler, en partie, une circuiterie corticale en CaBPs qui lui est propre dans le cortex hôte ou recruté. Ainsi, nos travaux appuient l’hypothèse selon laquelle il serait possible que certaines de ces sous-populations d’interneurones GABAergiques jouent un rôle crucial dans le phénomène de la plasticité intermodale.
Resumo:
There are three trivial misprints in our paper.
Resumo:
Although MRI is utilized for planning the resection of soft-tissue tumors, it is not always capable of differentiating benign from malignant lesions. The risk of local recurrence of soft-tissue sarcomas is increased when biopsies are performed before resection and by inadequate resections. PET associated with computed tomography using fluorodeoxyglucose labeled with fluorine-18 ((18)F-FDG PET/CT) may help differentiate between benign and malignant tumors, thus avoiding inadequate resections and making prior biopsies unnecessary. The purpose of this study was to evaluate the usefulness of (18)F-FDG PET/CT in differentiating benign from malignant solid soft-tissue lesions. Patients with solid lesions of the limbs or abdominal wall detected by MRI were submitted to (18)F-FDG PET/CT. The maximum standardized uptake value (SUVmax) cutoff was determined to differentiate malignant from benign tumors. Regardless of the (18)F-FDG PET/CT results all patients underwent biopsy and surgery. MRI was performed in 54 patients, and 10 patients were excluded because of purely lipomatose or cystic lesions. (18)F-FDG PET/CT was performed in the remaining 44 patients. Histopathology revealed 26 (59%) benign and 18 (41%) malignant soft-tissue lesions. A significant difference in SUVmax was observed between benign and malignant soft-tissue lesions. The SUVmax cutoff of 3.0 differentiated malignant from benign lesions with 100% sensitivity, 83.3% specificity, 89.6% accuracy, 78.3% positive predictive value, and 100% negative predictive value. (18)F-FDG PET/CT seems to be able to differentiate benign from malignant soft-tissue lesions with good accuracy and very high negative predictive value. Incorporating (18)F-FDG PET/CT into the diagnostic algorithm of these patients may prevent inadequate resections and unnecessary biopsies.
Resumo:
We derive a new implementation of linear covariant gauges on the lattice, based on a minimizing functional that can be interpreted as the Hamiltonian of a spin-glass model in a random external magnetic field. We show that our method solves most problems encountered in earlier implementations, mostly related to the no-go condition formulated by Giusti [Nucl. Phys. B498, 331 (1997)]. We carry out tests in the SU(2) case in four space-time dimensions. We also present preliminary results for the transverse gluon propagator at different values of the gauge parameter xi.
Resumo:
Objectives The first objective of this study was to evaluate the radiological impact on relatives and the environment because of outpatient treatment of differentiated thyroid carcinoma with 3.7 and 5.55 GBq of ((131)I)NaI. The second objective was to determine, analyze, and evaluate whole-body radiation dose to caregivers, the production of contaminated solid waste, and the potentiality of radiation dose and surface contamination existing inside patients` households. Methods Twenty patients were treated on an outpatient basis, taking into consideration their acceptable living conditions, interests, and willingness to comply with medical and radiation-safety guidelines. The caregivers themselves, as well as the potentiality of the radiation dose inside patients` residences, were monitored with a thermo-luminescence dosimeter. Surface contamination and contaminated solid wastes were identified and measured by using a Geiger-Muller detector. Results and discussion Twenty-six monitored individuals received accumulated effective radiation doses of less than 1.0 mSv, and only one 2.8 mSv, throughout the 7 days of measurement. The maximum registered value for the potential of radiation dose inside all living areas was 1.30 mSv. The monitored surface contamination inside patients` dwellings showed a mean value of 4.2 Bq/cm(2) for all surfaces found to be contaminated. A total of 2.5l of contaminated solid waste was generated by the patients with 3.33 MBq of all estimated activity. Conclusion This study revealed that the treatment of differentiated thyroid carcinoma with 3.7 and 5.55 GBq of ((131)I)NaI, on an outpatient basis, can be safe when overseen by qualified professionals and with an adapted radiation-protection guideline. Even considering the radioiodine activity level and the dosimetric methodology applied here, negligible human exposure and a nonmeasurable radiological impact to the human environment were found. Nucl Med Commun 30:533-541 (C) 2009 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Resumo:
A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). Methods: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. Results: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. Conclusion: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.
Resumo:
Renal scintigraphy with 99mTc-dimercaptosuccinic acid (99mTc-DMSA) is performed with the aim of detect cortical abnormalities related to urinary tract infection and accurately quantify relative renal function (RRF). For this quantitative assessment Nuclear Medicine Technologist should draw regions of interest (ROI) around each kidney (KROI) and peri-renal background (BKG) ROI although controversy still exists about BKG-ROI. The aim of this work was to evaluate the effect of the normalization procedure, number and location of BKG-ROI on the RRF in 99mTc-DMSA scintigraphy.
Resumo:
The main purpose of the present study is to determine if the circadian rhythms present in the human bone marrow are likely to influence 3’- deoxy- 3’-[18F] Fluorothymidine (18F-FLT) uptake in the same organ. The 18F-FLT is a Thymidine analogous proliferation agent. The relatively high physiological uptake of this tracer in the bone marrow diminishes the Tumor/Background (T/B) ratio, decreasing the detection accuracy of PET/CT and possibly affecting SUV quantifications.
Resumo:
Tomographic image can be degraded, partially by patient based attenuation. The aim of this paper is to quantitatively verify the effects of attenuation correction methods Chang and CT in 111In studies through the analysis of profiles from abdominal SPECT, correspondent to a uniform radionuclide uptake organ, the left kidney.
Resumo:
Objective - To describe and validate the simulation of the basic features of GE Millennium MG gamma camera using the GATE Monte Carlo platform. Material and methods - Crystal size and thickness, parallel-hole collimation and a realistic energy acquisition window were simulated in the GATE platform. GATE results were compared to experimental data in the following imaging conditions: a point source of 99mTc at different positions during static imaging and tomographic acquisitions using two different energy windows. The accuracy between the events expected and detected by simulation was obtained with the Mann–Whitney–Wilcoxon test. Comparisons were made regarding the measurement of sensitivity and spatial resolution, static and tomographic. Simulated and experimental spatial resolutions for tomographic data were compared with the Kruskal–Wallis test to assess simulation accuracy for this parameter. Results - There was good agreement between simulated and experimental data. The number of decays expected when compared with the number of decays registered, showed small deviation (≤0.007%). The sensitivity comparisons between static acquisitions for different distances from source to collimator (1, 5, 10, 20, 30cm) with energy windows of 126–154 keV and 130–158 keV showed differences of 4.4%, 5.5%, 4.2%, 5.5%, 4.5% and 5.4%, 6.3%, 6.3%, 5.8%, 5.3%, respectively. For the tomographic acquisitions, the mean differences were 7.5% and 9.8% for the energy window 126–154 keV and 130–158 keV. Comparison of simulated and experimental spatial resolutions for tomographic data showed no statistically significant differences with 95% confidence interval. Conclusions - Adequate simulation of the system basic features using GATE Monte Carlo simulation platform was achieved and validated.
Resumo:
The foot and the ankle are small structures commonly affected by disorders, and their complex anatomy represent significant diagnostic challenges. SPECT/CT Image fusion can provide missing anatomical and bone structure information to functional imaging, which is particularly useful to increase diagnosis certainty of bone pathology. However, due to SPECT acquisition duration, patient’s involuntary movements may lead to misalignment between SPECT and CT images. Patient motion can be reduced using a dedicated patient support. We aimed at designing an ankle and foot immobilizing device and measuring its efficacy at improving image fusion. Methods: We enrolled 20 patients undergoing distal lower-limb SPECT/CT of the ankle and the foot with and without a foot holder. The misalignment between SPECT and CT images was computed by manually measuring 14 fiducial markers chosen among anatomical landmarks also visible on bone scintigraphy. Analysis of variance was performed for statistical analysis. Results: The obtained absolute average difference without and with support was 5.1±5.2 mm (mean±SD) and 3.1±2.7 mm, respectively, which is significant (p<0.001). Conclusion: The introduction of the foot holder significantly decreases misalignment between SPECT and CT images, which may have clinical influence in the precise localization of foot and ankle pathology.
Resumo:
Purpose - The education and training of a nuclear medicine technologist (NMT) is not homogeneous among European countries, which leads to different scope of practices and, therefore, different technical skills are assigned. The goal of this research was to characterize the education and training of NMT in Europe. Materials and methods - This study was based on a literature research to characterize the education and training of NMT and support the historical evolution of this profession. It was divided into two different phases: the first phase included analysis of scientific articles and the second phase included research of curricula that allow health professionals to work as NMT in Europe. Results - The majority of the countries [N=31 (89%)] offer the NMT curriculum integrated into the high education system and only in four (11%) countries the education is provided by professional schools. The duration in each education system is not equal, varying in professional schools (2-3 years) and high education level system (2-4 years), which means that different European Credit Transfer and Accumulation System, such as 240, 230, 222, 210 or 180 European Credit Transfer and Accumulation System, are attributed to the graduates. The professional title and scope of the practice of NMT are different in different countries in Europe. In most countries of Europe, nuclear medicine training is not specific and curriculum does not demonstrate the Nuclear Medicine competencies performed in clinical practice. Conclusion - The heterogeneity in education and training for NMT is an issue prevalent among European countries. For NMT professional development, there is a huge need to formalize and unify educational and training programmes in Europe.
Resumo:
Myocardial perfusion gated-single photon emission computed tomography (gated-SPECT) imaging is used for the combined evaluation of myocardial perfusion and left ventricular (LV) function. The aim of this study is to analyze the influence of counts/pixel and concomitantly the total counts in the myocardium for the calculation of myocardial functional parameters. Material and methods: Gated-SPECT studies were performed using a Monte Carlo GATE simulation package and the NCAT phantom. The simulations of these studies use the radiopharmaceutical 99mTc-labeled tracers (250, 350, 450 and 680MBq) for standard patient types, effectively corresponding to the following activities of myocardium: 3, 4.2, 5.4-8.2MBq. All studies were simulated using 15 and 30s/projection. The simulated data were reconstructed and processed by quantitative-gated-SPECT software, and the analysis of functional parameters in gated-SPECT images was done by using Bland-Altman test and Mann-Whitney-Wilcoxon test. Results: In studies simulated using different times (15 and 30s/projection), it was noted that for the activities for full body: 250 and 350MBq, there were statistically significant differences in parameters Motility and Thickness. For the left ventricular ejection fraction (LVEF), end-systolic volume (ESV) it was only for 250MBq, and 350MBq in the end-diastolic volume (EDV), while the simulated studies with 450 and 680MBq showed no statistically significant differences for global functional parameters: LVEF, EDV and ESV. Conclusion: The number of counts/pixel and, concomitantly, the total counts per simulation do not significantly interfere with the determination of gated-SPECT functional parameters, when using the administered average activity of 450MBq, corresponding to the 5.4MBq of the myocardium, for standard patient types.
Resumo:
FUNDAMENTO: O fenômeno da isquemia e reperfusão intestinal é um evento frequente na clínica e está associado a repercussões deletérias em órgãos a distância, em especial ao coração. OBJETIVO: Investigar a expressão gênica do estresse oxidativo e defesa antioxidante no coração de camundongos isogênicos, submetidos a isquemia e reperfusão intestinal (IR). MÉTODOS: Doze camundongos (C57BL/6) foram distribuídos em dois grupos: Grupo IR (GIR) com 60 min de oclusão da artéria mesentérica superior, seguidos de 60 min de reperfusão. Grupo Controle (GC) submetidos a anestesia e a laparotomia sem o procedimento de IR observados por 120 min. As amostras de intestino e coração foram processadas pelo método (RT-qPCR / Reverse transcriptase - quantitative Polymerase Chain Reaction) para determinar a expressão gênica de 84 genes relacionados ao estresse oxidativo ("t" de Student, p < 0,05). RESULTADOS: Observou-se no tecido intestinal (GIR) uma expressão significantemente aumentada em 65 (74,71%) genes em relação ao tecido normal (GC), e 37 (44,04%) genes estiveram hiperexpressos (maior que três vezes o limiar permitido pelo algoritmo). No tocante aos efeitos da I/R intestinal a distância no tecido cardíaco verificou-se a expressão significantemente aumentada de 28 genes (33,33%), mas somente oito genes (9,52%) se hiperexpressaram três vezes acima do limiar. Quatro (7,14%) desses oito genes se expressaram simultaneamente nos tecidos intestinal e cardíaco. No GIR notaram-se cardiomiócitos com núcleos de menor tamanho, picnóticos, ricos em heterocromatina e raros nucléolos, indicando sofrimento cardíaco. CONCLUSÃO: A I/R intestinal promoveu a hiperexpressão estatisticamente significante de oito genes associados ao estresse oxidativo a distância no tecido miocárdico.