997 resultados para non radiographic axial spondylarthritis
Resumo:
To compare the impact of meeting specific classification criteria [modified New York (mNY), European Spondyloarthropathy Study Group (ESSG), and Assessment of SpondyloArthritis international Society (ASAS) criteria] on anti-tumor necrosis factor (anti-TNF) drug retention, and to determine predictive factors of better drug survival. All patients fulfilling the ESSG criteria for axial spondyloarthritis (SpA) with available data on the axial ASAS and mNY criteria, and who had received at least one anti-TNF treatment were retrospectively retrieved in a single academic institution in Switzerland. Drug retention was computed using survival analysis (Kaplan-Meier), adjusted for potential confounders. Of the 137 patients classified as having axial SpA using the ESSG criteria, 112 also met the ASAS axial SpA criteria, and 77 fulfilled the mNY criteria. Drug retention rates at 12 and 24 months for the first biologic therapy were not significantly different between the diagnostic groups. Only the small ASAS non-classified axial SpA group (25 patients) showed a nonsignificant trend toward shorter drug survival. Elevated CRP level, but not the presence of bone marrow edema on magnetic resonance imaging (MRI) scans, was associated with significantly better drug retention (OR 7.9, ICR 4-14). In this cohort, anti-TNF drug survival was independent of the classification criteria. Elevated CRP level, but not positive MRI, was associated with better drug retention.
Resumo:
Objectives:¦The aim of this study was to estimate the prevalence of subclinical small joint synovitis detected by ultrasonography in patients with axial SpA, and to evaluate their relevance in terms of function or and disease activity.¦Methods:¦Forty axial SpA patients, 40 RA and 20 healthy subjects were evaluated by ultrasonography, using a reproducible semi-quantitative score by B-mode and Doppler, for synovitis, while disease activity and function were assessed using validated instruments (DAS28, BASDAI, BASFI, m-SACRAH and HAQ).¦Results:¦Median B-mode score were respectively 8.2 for axial SpA, 11.5 for RA and 6.0 for healthy subjects, corresponding to a prevalence of clinical significant synovitis of respectively 37.5%, 60% and 11% for a level of significance at > 8 chosen to¦classify as active > 75% of RA patient with DAS28 >2.6 and < 10% of controls. Addtionally, Doppler was positive in 8% of SpA, 30 % of RA and none of the healthy subjects. Echographic synovitis correlated with disease activity (DAS28) and function¦(HAQ, mSACRAH) in RA patients, but no correlation were found for SpA patients with disease activity (BASDAI) or function (BASFI, HAQ, mSACRAH). Cases of synovitis using classification by Doppler positivity were insufficient to allow any¦statistical analysis.¦Conclusions:¦B-mode ultrasonographic evaluation can demonstrate subclinical synovitis in almost 40% of SpA patients, but they do not appear to correlate with disease activity or function on the contrary to what is observed in RA patients, representing potentially different processes
Resumo:
BACKGROUND: Adequate pain assessment is critical for evaluating the efficacy of analgesic treatment in clinical practice and during the development of new therapies. Yet the currently used scores of global pain intensity fail to reflect the diversity of pain manifestations and the complexity of underlying biological mechanisms. We have developed a tool for a standardized assessment of pain-related symptoms and signs that differentiates pain phenotypes independent of etiology. METHODS AND FINDINGS: Using a structured interview (16 questions) and a standardized bedside examination (23 tests), we prospectively assessed symptoms and signs in 130 patients with peripheral neuropathic pain caused by diabetic polyneuropathy, postherpetic neuralgia, or radicular low back pain (LBP), and in 57 patients with non-neuropathic (axial) LBP. A hierarchical cluster analysis revealed distinct association patterns of symptoms and signs (pain subtypes) that characterized six subgroups of patients with neuropathic pain and two subgroups of patients with non-neuropathic pain. Using a classification tree analysis, we identified the most discriminatory assessment items for the identification of pain subtypes. We combined these six interview questions and ten physical tests in a pain assessment tool that we named Standardized Evaluation of Pain (StEP). We validated StEP for the distinction between radicular and axial LBP in an independent group of 137 patients. StEP identified patients with radicular pain with high sensitivity (92%; 95% confidence interval [CI] 83%-97%) and specificity (97%; 95% CI 89%-100%). The diagnostic accuracy of StEP exceeded that of a dedicated screening tool for neuropathic pain and spinal magnetic resonance imaging. In addition, we were able to reproduce subtypes of radicular and axial LBP, underscoring the utility of StEP for discerning distinct constellations of symptoms and signs. CONCLUSIONS: We present a novel method of identifying pain subtypes that we believe reflect underlying pain mechanisms. We demonstrate that this new approach to pain assessment helps separate radicular from axial back pain. Beyond diagnostic utility, a standardized differentiation of pain subtypes that is independent of disease etiology may offer a unique opportunity to improve targeted analgesic treatment.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A rigorous derivation of non-linear equations governing the dynamics of an axially loaded beam is given with a clear focus to develop robust low-dimensional models. Two important loading scenarios were considered, where a structure is subjected to a uniformly distributed axial and a thrust force. These loads are to mimic the main forces acting on an offshore riser, for which an analytical methodology has been developed and applied. In particular, non-linear normal modes (NNMs) and non-linear multi-modes (NMMs) have been constructed by using the method of multiple scales. This is to effectively analyse the transversal vibration responses by monitoring the modal responses and mode interactions. The developed analytical models have been crosschecked against the results from FEM simulation. The FEM model having 26 elements and 77 degrees-of-freedom gave similar results as the low-dimensional (one degree-of-freedom) non-linear oscillator, which was developed by constructing a so-called invariant manifold. The comparisons of the dynamical responses were made in terms of time histories, phase portraits and mode shapes. (C) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.
Resumo:
The aim of this study was to describe the axial skeleton of a wild Brazilian carnivorous, the crab-eating fox (Cerdocyon thous). Five specimens of crab-eating fox were previously unfrozen for radiographic exams and their bones went through dissection and chemical maceration. This animal presents seven cervical vertebrae, and from the third on, they become shorter and wider than the other ones e the spinous process was makeable from the fifth cervical vertebrae on. There are thirteen thoracic vertebrae and the spinous process of the lumbar vertebrae, which are seven, decreases from the fifth on. The sacrum is formed by two vertebrae and there are twenty or twenty one caudal vertebrae. It can be concluded that the crab-eating fox axial skeleton is similar to that of the domestic dog.
Resumo:
The agouti is a species intensively hunted throughout the Amazon and the semi-arid regions of northeastern Brazil. Considering the current trend in conservation management of wild species, the aim of this study was to determine the morphometric reference to the heart of agouti raised in captivity, based on thoracic and cardiac measurements in these animals. Thirty adult agoutis, 1 to 3 years of age, without clinical signs of cardiac disease were selected. The animals were physically restrained and radiographies in laterolateral (LL) and ventrodorsal (VD) recumbence were produced. The following measures were taken: the apicobasilar length of the heart (at the most cranial height of the Carina region to the heart apex) (AB), maximum width of the heart perpendicular to AB (CD), heart inclination angle (AIC), trachea inclination angle (AIT), distance from the right heart wall (DPTd), distance from the left heart wall (DPTe) and vertical depth of the thorax, and the ventral face of the vertebral column to the dorsal border of the sternum at the level of the trachea bifurcation (H). The ratios between AB/CD, AB/H and CD/H were also analyzed. To calculate the vertebral heart scale (VHS), the AB and CD measurements were laid over the thoracic vertebra starting at T4. Radiographic evaluation showed values consistent with those reported in small animals and some wild and exotic species. The main biometric values in the chest cavity and heart of agouti are arranged as follows: (1) The ratios between AB/H ratio and CD/H were not sensitive for identifying heart increases (p>0.05), while the ratio AB/CD was more sensitive in this identification (p<0.05); (2) AIC: 21.2±6.4º (mean between male and famale); (3) AIT for males and females: 9.93±3.23° and 8.4±3.94°; (4) DPTd and DPTe for males: 0.97±0.40cm and 0.7±0.30cm; (5) DPTd and DPTe for females: 1.12±0.42cm and 01.02±0.43cm; (6) VHS for males and females: 7.75±0.48v e 7.61±0.34v; (7) The caudal vena cava (CVC) was visualized dorsal-cranially and located right of the midline. The data obtained allowed the acquisition of the first reference values for biometry of the heart of agoutis, contributing to better understanding of cardiac morphology and identification of cardiomyopathy in these animals.
Resumo:
Improving the appearance of the trunk is an important goal of scoliosis surgical treatment, mainly in patients' eyes. Unfortunately, existing methods for assessing postoperative trunk appearance are rather subjective as they rely on a qualitative evaluation of the trunk shape. In this paper, an objective method is proposed to quantify the changes in trunk shape after surgery. Using a non-invasive optical system, the whole trunk surface is acquired and reconstructed in 3D. Trunk shape is described by two functional measurements spanning the trunk length: the lateral deviation and the axial rotation. To measure the pre and postoperative differences, a correction rate is computed for both measurements. On a cohort of 36 scoliosis patients with the same spinal curve type who underwent the same surgical approach, surgery achieved a very good correction of the lateral trunk deviation (median correction of 76%) and a poor to moderate correction of the back axial rotation (median correction of 19%). These results demonstrate that after surgery, patients are still confronted with residual trunk deformity, mainly a persisting hump on the back. That can be explained by the fact that current scoliosis assessment and treatment planning are based solely on radiographic measures of the spinal deformity and do not take trunk deformity into consideration. It is believed that with our novel quantitative trunk shape descriptor, clinicians and surgeons can now objectively assess trunk deformity and postoperative shape and propose new treatment strategies that could better address patients' concern about their appearance. © (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Resumo:
Fiber reinforced polymer composites have been widely applied in the aeronautical field. However, composite processing, which uses unlocked molds, should be avoided in view of the tight requirements and also due to possible environmental contamination. To produce high performance structural frames meeting aeronautical reproducibility and low cost criteria, the Brazilian industry has shown interest to investigate the resin transfer molding process (RTM) considering being a closed-mold pressure injection system which allows faster gel and cure times. Due to the fibrous composite anisotropic and non homogeneity characteristics, the fatigue behavior is a complex phenomenon quite different from to metals materials crucial to be investigated considering the aeronautical application. Fatigue sub-scale specimens of intermediate modulus carbon fiber non-crimp multi-axial reinforcement and epoxy mono-component system composite were produced according to the ASTM 3039 D. Axial fatigue tests were carried out according to ASTM D 3479. A sinusoidal load of 10 Hz frequency and load ratio R = 0.1. It was observed a high fatigue interval obtained for NCF/RTM6 composites. Weibull statistical analysis was applied to describe the failure probability of materials under cyclic loads and fractures pattern was observed by scanning electron microscopy. (C) 2010 Published by Elsevier Ltd.