988 resultados para monitoring failure


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Marnet, Oliver, 'Behaviour and rationality in corporate governance', Journal of Economic Issues (2005) 39(3) pp.613-632 RAE2008

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Jargon aphasia with neologisms (i.e., novel nonword utterances) is a challenging language disorder that lacks a definitive theoretical description as well as clear treatment recommendations (Marshall, 2006). Aim: The aims of this two part investigation were to determine the source of neologisms in an individual with jargon aphasia (FF), to identify potential facilitatory semantic and/or phonological cuing effects in picture naming, and to determine whether the timing of the cues relative to the target picture mediated the cuing advantage. Methods and Procedures: FF’s underlying linguistic deficits were determined using several cognitive and linguistic tests. A series of computerized naming experiments using a modified version of the 175 item-Philadelphia Naming Test (Roach, Schwartz, Martin, Grewal, & Brecher, 1996) manipulated the cue type (semantic versus phonological) and relatedness (related versus unrelated). In a follow-up experiment, the relative timing of phonological cues was manipulated to test the effect of timing on the cuing advantage. The accuracy of naming responses and error patterns were analyzed. Outcome and Results: FF’s performance on the linguistic and cognitive test battery revealed a severe naming impairment with relatively spared word and nonword repetition, auditory comprehension of words and monitoring, and fairly well preserved semantic abilities. This performance profile was used to evaluate various explanations for neologisms including a loss of phonological codes, monitoring failure, and impairments in semantic system. The primary locus of his deficit appears to involve the connection between semantics to phonology, specifically, when word production involves accessing the phonological forms following semantic access. FF showed a significant cuing advantage only for phonological cues in picture naming, particularly when the cue preceded or coincided with the onset of the target picture. Conclusions: When integrated with previous findings, the results from this study suggest that the core deficit of this and at least some other jargon aphasics is in the connection from semantics to phonology. The facilitative advantage of phonological cues could potentially be exploited in future clinical and research studies to test the effectiveness of these cues for enhancing naming performance in individuals like FF.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Although the potential to reduce hospitalisation and mortality in chronic heart failure (CHF) is well reported, the feasibility of receiving healthcare by structured telephone support or telemonitoring is not. Aims: To determine; adherence, adaptation and acceptability to a national nurse-coordinated telephone-monitoring CHF management strategy. The Chronic Heart Failure Assistance by Telephone Study (CHAT). Methods: Triangulation of descriptive statistics, feedback surveys and qualitative analysis of clinical notes. Cohort comprised of standard care plus intervention (SC + I) participants who completed the first year of the study. Results: 30 GPs (70% rural) randomised to SC + I recruited 79 eligible participants, of whom 60 (76%) completed the full 12 month follow-up period. During this time 3619 calls were made into the CHAT system (mean 45.81 SD ± 79.26, range 0-369), Overall there was an adherence to the study protocol of 65.8% (95% CI 0.54-0.75; p = 0.001) however, of the 60 participants who completed the 12 month follow-up period the adherence was significantly higher at 92.3% (95% CI 0.82-0.97, p ≤ 0.001). Only 3% of this elderly group (mean age 74.7 ±9.3 years) were unable to learn or competently use the technology. Participants rated CHAT with a total acceptability rate of 76.45%. Conclusion: This study shows that elderly CHF patients can adapt quickly, find telephone-monitoring an acceptable part of their healthcare routine, and are able to maintain good adherence for a least 12 months. © 2007.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Aims: This paper describes the development of a risk adjustment (RA) model predictive of individual lesion treatment failure in percutaneous coronary interventions (PCI) for use in a quality monitoring and improvement program. Methods and results: Prospectively collected data for 3972 consecutive revascularisation procedures (5601 lesions) performed between January 2003 and September 2011 were studied. Data on procedures to September 2009 (n = 3100) were used to identify factors predictive of lesion treatment failure. Factors identified included lesion risk class (p < 0.001), occlusion type (p < 0.001), patient age (p = 0.001), vessel system (p < 0.04), vessel diameter (p < 0.001), unstable angina (p = 0.003) and presence of major cardiac risk factors (p = 0.01). A Bayesian RA model was built using these factors with predictive performance of the model tested on the remaining procedures (area under the receiver operating curve: 0.765, Hosmer–Lemeshow p value: 0.11). Cumulative sum, exponentially weighted moving average and funnel plots were constructed using the RA model and subjectively evaluated. Conclusion: A RA model was developed and applied to SPC monitoring for lesion failure in a PCI database. If linked to appropriate quality improvement governance response protocols, SPC using this RA tool might improve quality control and risk management by identifying variation in performance based on a comparison of observed and expected outcomes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Remote monitoring for heart failure has been evaluated in numerous systematic reviews. The aim of this meta-review was to appraise their quality and synthesise results. We electronically searched online databases, performed a forward citation search and hand-searched bibliographies. Systematic reviews of remote monitoring interventions that were used for surveillance of heart failure patients were included. Seven (41%) systematic reviews pooled results for meta-analysis. Eight (47%) considered all non-invasive remote monitoring strategies. Five (29%) focused on telemonitoring. Four (24%) included both non-invasive and invasive technologies. According to AMSTAR criteria, ten (58%) systematic reviews were of poor methodological quality. In high quality reviews, the relative risk of mortality in patients who received remote monitoring ranged from 0.53 (95% CI=0.29-0.96) to 0.88 (95% CI=0.76-1.01). High quality reviews also reported that remote monitoring reduced the relative risk of all-cause (0.52; 95% CI=0.28-0.96 to 0.96; 95% CI=0.90–1.03) and heart failure-related hospitalizations (0.72; 95% CI=0.64–0.81 to RR 0.79; 95% CI=0.67-0.94) and, as a consequence, healthcare costs. As the high quality reviews reported that remote monitoring reduced hospitalizations, mortality and healthcare costs, research efforts should now be directed towards optimising these interventions in preparation for more widespread implementation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background/aims: Remote monitoring for heart failure has not only been evaluated in a large number of randomised controlled trials, but also in many systematic reviews and meta-analyses. The aim of this meta-review was to identify, appraise and synthesise existing systematic reviews that have evaluated the effects of remote monitoring in heart failure. Methods: Using a Cochrane methodology, we electronically searched all relevant online databases and search engines, performed a forward citation search as well as hand-searched bibliographies. Only fully published systematic reviews of invasive and/or non-invasive remote monitoring interventions were included. Two reviewers independently extracted data. Results: Sixty-five publications from 3333 citations were identified. Seventeen fulfilled the inclusion and exclusion criteria. Quality varied with A Measurement Tool to Assess Systematic Reviews (AMSTAR scores) ranging from 2 to 11 (mean 5.88). Seven reviews (41%) pooled results from individual studies for meta-analysis. Eight (47%) considered all non-invasive remote monitoring strategies. Four (24%) focused specifically on telemonitoring. Four (24%) included studies investigating both non-invasive and invasive technologies. Population characteristics of the included studies were not reported consistently. Mortality and hospitalisations were the most frequently reported outcomes 12 (70%). Only five reviews (29%) reported healthcare costs and compliance. A high degree of heterogeneity was reported in many of the meta-analyses. Conclusions: These results should be considered in context of two negative RCTs of remote monitoring for heart failure that have been published since the meta-analyses (TIM-HF and Tele-HF). However, high quality reviews demonstrated improved mortality, quality of life, reduction in hospitalisations and healthcare costs.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Trials of new technologies to remotely monitor for signs and symptoms of worsening heart failure are continually emerging. The extent to which technological differences impact the effectiveness of non-invasive remote monitoring for heart failure management is unknown. Objective To examine the effect of specific technology used for non-invasive remote monitoring of people with heart failure on all-cause mortality and heart failure-related hospitalisations. Methods A sub-analysis of a large systematic review and meta-analysis was conducted. Studies were stratified according to the specific type of technology used and separate meta-analyses were performed. Four different types of non-invasive remote monitoring technologies were identified including structured telephone calls, videophone, interactive voice response devices and telemonitoring. Results Only structured telephone calls and telemonitoring were effective in reducing the risk of all-cause mortality (RR 0.87; 95% CI=0.75-1.01; p=0.06 and 0.62; 95% CI=0.50-0.77; p<0.0001) and heart failure-related hospitalisations (RR 0.77; 95% CI=0.68-0.87; p<0.001) and 0.75; 95% CI=0.63-0.91; p=0.003). More research data is required for videophone and interactive voice response technologies. Conclusions This sub-analysis identified that only two of the four specific technologies used for non-invasive remote monitoring in heart failure improved outcomes. When results of studies that involved these disparate technologies were combined in previous meta-analyses, significant improvements in outcomes were identified. As such, this study has highlighted implications for future meta-analyses of randomised controlled trials focused on evaluating the effectiveness of remote monitoring in heart failure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background There are few data regarding the effectiveness of remote monitoring for older people with heart failure. We conducted a post-hoc sub-analysis of a previously published large Cochrane systematic review and meta-analysis of relevant randomized controlled trials to determine whether structured telephone support and telemonitoring were effective in this population. Methods A post hoc sub-analysis of a systematic review and meta-analysis that applied the Cochrane methodology was conducted. Meta-analyses of all-cause mortality, all-cause hospitalizations and heart failure-related hospitalizations were performed for studies where the mean or median age of participants was 70 or more years. Results The mean or median age of participants was 70 or more years in eight of the 16 (n=2,659/5,613; 47%) structured telephone support studies and four of the 11 (n=894/2,710; 33%) telemonitoring studies. Structured telephone support (RR 0.80; 95% CI=0.63-1.00) and telemonitoring (RR 0.56; 95% CI=0.41-0.76) interventions reduced mortality. Structured telephone support interventions reduced heart failure-related hospitalizations (RR 0.81; 95% CI=0.67-0.99). Conclusion Despite a systematic bias towards recruitment of individuals younger than the epidemiological average into the randomized controlled trials, older people with heart failure did benefit from structured telephone support and telemonitoring. These post-hoc sub-analysis results were similar to overall effects observed in the main meta-analysis. While further research is required to confirm these observational findings, the evidence at hand indicates that discrimination by age alone may be not be appropriate when inviting participation in a remote monitoring service for heart failure.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An approach to achieving the ambitious goal of cost effectively extending the safe operation life of energy pipelines to, for instance, 100 years is the application of structural health monitoring and life prediction tools that are able to provide long-term remnant pipeline life prediction and in-situ pipeline condition monitoring. A critical step in pipeline structural health monitoring is the enhancement of technological capabilities that are required for quantifying the effects of key factors influencing buried pipeline corrosion and environmentally assisted materials degradation, and the development of condition monitoring technologies that are able to provide in-situ monitoring and site-specific warning of pipeline damage. This paper provides an overview of our current research aimed at developing new sensors for monitoring, categorising and quantifying the level and nature of external pipeline and coating damages under the combined effects of various inter-related variables and processes such as localised corrosion, coating damage and disbondment, cathodic shielding. The concept of in-situ monitoring and site-specific warning of pipeline corrosion is illustrated by a case of monitoring localised corrosion under disbonded coatings using a new corrosion monitoring probe. A basic principle that underpins the use of sensors to monitor localised corrosion has been presented: Localised corrosion and coating failure are not an accidental occurrence, it occurs as the result of fundamental thermodynamic instability of a metal exposed to a specific environment. Therefore corrosion and coating disbondment occurring on a pipeline will also occur on a sensor made of the same material and exposed to the same pipeline condition. Although the exact location of localised corrosion or coating disbondment could be difficult to pinpoint along the length of a buried pipeline, the ‘worst-case scenario’ and high risk pipeline sections and sites are predictable. Sensors can be embedded at these strategic sites to collect data that contain ‘predictor features’ signifying the occurrence of localised corrosion, CP failure, coating disbondment and degradation. Information from these sensors will enable pipeline owners to prioritise site survey and inspection operations, and to develop maintenance strategy to manage aged pipelines, rather than replace them.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Acute liver failure (ALF) models in pigs have been widely used for evaluating newly developed liver support systems. But hardly any guidelines are available for the surgical methods and the clinical management.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Congestive heart failure has long been one of the most serious medical conditions in the United States; in fact, in the United States alone, heart failure accounts for 6.5 million days of hospitalization each year. One important goal of heart-failure therapy is to inhibit the progression of congestive heart failure through pharmacologic and device-based therapies. Therefore, there have been efforts to develop device-based therapies aimed at improving cardiac reserve and optimizing pump function to meet metabolic requirements. The course of congestive heart failure is often worsened by other conditions, including new-onset arrhythmias, ischemia and infarction, valvulopathy, decompensation, end-organ damage, and therapeutic refractoriness, that have an impact on outcomes. The onset of such conditions is sometimes heralded by subtle pathophysiologic changes, and the timely identification of these changes may promote the use of preventive measures. Consequently, device-based methods could in the future have an important role in the timely identification of the subtle pathophysiologic changes associated with congestive heart failure.