862 resultados para mini-projects
Resumo:
This paper reports the results of a three-year study of the effectiveness of mini-projects in a first year laboratory course in chemistry at a Scottish university. A mini-project is a short, practical problem which requires for its solution the application of the knowledge and skills developed in previously completed set experiments. A number of recommendations have been made about the most appropriate ways of introducing mini-projects into undergraduate laboratory course. The main hypothesis of this survey was concerned with the value of mini-projects in laboratory courses formulated within the context of Information Processing Theory.
Resumo:
From an analysis of a learning model based on the theory of information processing four hypothesis were developed for improving the design of laboratory courses. Three of these hypotheses concerned specific procedures to minimise the load on students' working memories (or working spaces) and the fourth hypothesis was concerned with the value of mini-projects in enhancing meaningful learning of the knowledge and skills underpinning the set experiments. A three-year study of a first year undergraduate chemistry laboratory course at a Scottish university has been carried out to test these four hypotheses. This paper reports the results of the study relevant to the three hypotheses about the burden on students' working spaces. It was predicted from the learning model that the load on students working space should be reduced by appropriate changes to the written instructions and the laboratory organisation and by the introduction of prelab-work and prelab-training in laboratory techniques. It was concluded from research conducted over the three years period that all these hypothesised changes were effective both in reducing the load on students' working spaces and in improving their attitudes to the laboratory course.
Resumo:
Flexibles y accesibles, estos proyectos imaginativos ofrecen una gran cantidad de material fotocopiable y proyectos para complementar cualquier libro de curso. Los proyectos capturarán la imaginación de jóvenes estudiantes y les motivarán a hablar el inglés de una manera cooperativa mientras trabajan en el proyecto. El libro está escrito para profesores de inglés cuyos estudiantes son de edades comprendidas entre los once y los diecisiete años. Proyectos imaginativos está dividido en diez capítulos, los primeros ocho de estos están divididos en mini-proyectos, cada mini-proyecto es una lección.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Participation usually sets off from the bottom up, taking the form of more or less enduring forms of collective action with varying degrees of infl uence. However, a number of projects have been launched by political institutions in the last decades with a view to engaging citizens in public affairs and developing their democratic habits, as well as those of the administration. This paper analyses the political qualifying capacity of the said projects, i.e. whether participating in them qualifi es individuals to behave as active citizens; whether these projects foster greater orientation towards public matters, intensify (or create) political will, and provide the necessary skills and expertise to master this will. To answer these questions, data from the comparative analysis of fi ve participatory projects in France and Spain are used, shedding light on which features of these participatory projects contribute to the formation of political subjects and in which way. Finally, in order to better understand this formative dimension, the formative capacity of institutional projects is compared with the formative dimension of other forms of participation spontaneously developed by citizens.
Resumo:
The Ophira Mini Sling System involves anchoring a midurethral, low-tension tape to the obturator internus muscles bilaterally at the level of the tendinous arc. Success rates in different subsets of patients are still to be defined. This work aims to identify which factors influence the 2-year outcomes of this treatment. Analysis was based on data from a multicenter study. Endpoints for analysis included objective measurements: 1-h pad-weight (PWT), and cough stress test (CST), and questionnaires: International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) and Urinary Distress Inventory (UDI)-6. A logistic regression analysis evaluated possible risk factors for failure. In all, 124 female patients with stress urinary incontinence (SUI) underwent treatment with the Ophira procedure. All patients completed 1 year of follow-up, and 95 complied with the 2-year evaluation. Longitudinal analysis showed no significant differences between results at 1 and 2 years. The 2-year overall objective results were 81 (85.3%) patients dry, six (6.3%) improved, and eight (8.4%) incontinent. A multivariate analysis revealed that previous anti-incontinence surgery was the only factor that significantly influenced surgical outcomes. Two years after treatment, women with previous failed surgeries had an odds ratio (OR) for treatment failure (based on PWT) of 4.0 [95% confidence interval (CI) 1.02-15.57). The Ophira procedure is an effective option for SUI treatment, with durable good results. Previous surgeries were identified as the only significant risk factor, though previously operated patients showed an acceptable success rate.
Resumo:
OBJETIVO: este estudo teve como objetivo avaliar a influência da largura do septo inter-radicular no local de inserção de mini-implantes autoperfurantes sobre o grau de estabilidade desses dispositivos de ancoragem. MÉTODOS: a amostra consistiu de 40 mini-implantes inseridos entre as raízes do primeiro molar e segundo pré-molar superiores de 21 pacientes, com o intuito de fornecer ancoragem para retração anterior. A largura do septo no local de inserção (LSI) foi mensurada nas radiografias pós-cirúrgicas e, sob esse aspecto, os mini-implantes foram divididos em dois grupos: grupo 1 (áreas críticas, LSI<3mm) e grupo 2 (áreas não críticas, LSI>3mm). A estabilidade dos mini-implantes foi avaliada mensalmente pela quantificação do grau de mobilidade e a partir dessa variável foi calculada a proporção de sucesso. Avaliou-se também: a quantidade de placa, altura de inserção, grau de sensibilidade e período de observação. RESULTADOS: os resultados obtidos demonstraram que não houve diferença estatisticamente significativa para o grau de mobilidade e proporção de sucesso entre os mini-implantes inseridos em septos de largura mesiodistal crítica e não crítica. A proporção de sucesso total encontrada foi de 90% e nenhuma variável demonstrou estar relacionada ao insucesso dos mini-implantes. No entanto, observou-se maior sensibilidade nos pacientes cujos mini-implantes apresentavam mobilidade, e que a falha desses dispositivos de ancoragem ocorria logo após sua inserção. CONCLUSÃO: a largura do septo inter-radicular no local de inserção não interferiu na estabilidade dos mini-implantes autoperfurantes avaliados neste estudo.
Resumo:
This study evaluated fracture torque by torsion, in relation to the length and diameter of orthodontic mini-implants, to demonstrate their viability for clinical and experimental use based on the torque recommended by the manufacturers. The fractures at the moment of insertion, whose incidence in the literature is around 4%, are principally due to excessive force and the inability of the implant to resist rotational forces. Thirty orthodontic mini-implants of three commercial brands available in Brazil (Neodent 1.6 x 9 mm, Dentoflex 1.6 x 9 mm and Kopp 1.6 x 9 mm) were attached to a device made specifically for this research, leaving the mini-implants with sufficient stability. The miniimplants were submitted to torsion torque, using a digital torque wrench, until their breaking point. The values obtained with the test were submitted to analysis of variance and the Tukey test. The mean values of mini-implant ruptures were 26 N.cm for group A (Dentoflex), 25.4 N. cm for group B (Kopp) and 32.8 N.cm for group C (Neodent). From the Tukey test we could observe that the relationships between the means of the Dentoflex and Neodent groups, and between the Kopp and Neodent groups, were significant. Between the Dentoflex and Kopp groups, significance was nonexistent. All the values found in our research for fracture torque were higher than the limits recommended by the manufacturers for clinical use in orthodontics. The highest values were found in the Neodent group.
Resumo:
OBJETIVO: o propósito do presente estudo é avaliar o limite de resistência à flexão de um protótipo de mini-implante desenvolvido para ancoragem do aparelho de Herbst. MÉTODOS: após a realização de um cálculo do tamanho da amostra, quatro corpos de prova contendo os protótipos de mini-implantes foram submetidos a uma força de flexão por engastamento simples, utilizando-se uma máquina universal de ensaios mecânicos, sendo calculado o limite de resistência à força de flexão. RESULTADOS: após os ensaios mecânicos, os novos mini-implantes apresentaram o limite de resistência à força de flexão de 98,2kgf, que foi o menor valor encontrado. CONCLUSÃO: os protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst foram capazes de suportar forças de flexão maiores do que as forças de mordida descritas na literatura.
Resumo:
O objetivo deste trabalho foi avaliar a distribuição de tensões na resina em contato com os filetes de roscas de mini-implantes cilíndricos e cônicos, submetidos à carga lateral e torção de inserção. Um modelo fotoelástico foi confeccionado com gelatina transparente, para simular o osso alveolar. O modelo foi observado com um polariscópio plano e fotografado antes e após a ativação dos mini-implantes com força lateral e de inserção. A aplicação de cargas laterais provocou momentos fletores nos mini-implantes, aparecimento de franjas isocromáticas ao longo dos filetes do corpo dos mini-implantes e no ápice. Quando foi aplicado o torque de inserção, verificou-se a concentração de tensões próxima ao ápice. Concluiu-se que: (1) o mini-implante cilíndrico apresentou maior concentração de tensões no ápice, e (2) o mini-implante cônico apresentou maior concentração de tensões nos filetes de rosca apicais.
Resumo:
Objective: To describe the ultrastructure of the interface between periodontal tissues and titanium mini-implants in rat mandibles. Materials and Methods: A titanium mini-implant was placed between the buccal roots of the mandibular first molar of 24 adult rats. After 21, 30, 45, 60, 90, and 120 days of implantation, the mandibular portion was removed and fixed in cacodylate-buffered 2% glutaraldehyde + 2.5% formaldehyde. The material was decalcified and processed for scanning and transmission electron microscopy. Results: Ultrastructural analysis revealed a thin cementum-like layer at longer times after implantation at the areas in which the periodontal ligament was in contact with the implant. Conclusions: The alveolar bone and the periodontal ligament reorganized their constituents around the implant, and a thin cementum-like layer was formed at longer times after implantation at the areas in which the periodontal ligament was in contact with the implant. (Angle Orthod. 2010;80:459-435.)
Resumo:
This article presents an extensive investigation carried out in two technology-based companies of the So Carlos technological pole in Brazil. Based on this multiple case study and literature review, a method, entitled hereafter IVPM2, applying agile project management (APM) principles was developed. After the method implementation, a qualitative evaluation was carried out by a document analysis and questionnaire application. This article shows that the application of this method at the companies under investigation evidenced the benefits of using simple, iterative, visual, and agile techniques to plan and control innovative product projects combined with traditional project management best practices, such as standardization.
Resumo:
This article discusses the impact on the profitability of firms under Complementary Law 102/2000 (which abrogated the Law 89/96 - Kandir Law) allowing the appropriation of ICMS credits, due to investment in fixed assets goods, at a ratio of 1/48 per month. The paper seeks to demonstrate how this new system - which resulted in the transformation of the ICMS as a value added tax (VAT) consumption-type to an income-type - leads to a loss of approximately 30% of the value of credits to be recovered and the effect it generates on the cost of investment and the profits for small, medium and large firms. From the methodological point of view, it is a descriptive and quantitative research, which proceeded in three stages. Initially, we have obtained estimated value of net sales and volume of investments, based on report Painel de Competitividade prepared by the Federacao das Indtustrias do Estado de Sao Paulo (Fiesp/Serasa). Based on this information, it was possible to obtain estimates of the factors of generation of debits and credits for ICMS, using the model Credit Control of Fixed Assets (CIAP). Finally, we have calculated three indicators: (i) present value of debt recovery/value of credits, (ii) present value of debt recovery / investment value, (iii) present value of debt recovery / sales profitability. We have conclude that the system introduced by Complementary Law 102/2000 implicates great opportunity cost for firms and that legislation should be reviewed from this perspective, aiming to ensure lower costs associated with investment projects.
Resumo:
This paper reports the experiences and perceptions of student group projects of three cohorts of undergraduates: a 3rd year capstone course in professional communication (N = 54), a 3rd year elective in chemical engineering (N = 29), and a core 2nd-year course in chemical engineering (N = 74).