981 resultados para mini-implant


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective. This study evaluated the reliability of tooth-crown radiographic references to aid in orthodontic mini-implant insertion and showed an insertion technique based on these references. Study design. The sample consisted of 213 interradicular septa evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width and its midpoint was linked to the interdental contact point to determine septum midline (SML). The distances from SML to mesial and distal teeth were measured and compared to evaluate SML centralization degree in 2 different septum heights. Results. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. Conclusions. The tooth-crown radiographic references determine a high centralization degree of the SML on which an insertion site could be defined. The greater SML centralization degree was observed at the coronal septum area. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010;110:e8-e16)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: a ancoragem óssea é fundamental para o sucesso do tratamento de algumas más oclusões, pois permite a aplicação de forças contínuas, diminui o tempo de tratamento e independe da colaboração do paciente. MÉTODOS: o propósito desse trabalho foi comparar, por meio de modelos dentários, a perda de ancoragem após a retração inicial de caninos superiores entre dois grupos. O grupo A utilizou o mini-implante enquanto o grupo B utilizou o Botão de Nance. Para todos os pacientes foram realizados dois modelos (M1 e M2). Os primeiros modelos foram realizados ao início (M1), e os outros ao final da retração inicial de canino (M2). RESULTADOS: todas as medidas foram tabuladas e submetidas à análise estatística. Para verificar o erro sistemático intraexaminador foi utilizado o teste t pareado. Na determinação do erro casual utilizou-se o cálculo de erro proposto por Dahlberg. Para comparação entre as fases Início e Após, foi utilizado o teste t pareado. Para a comparação entre os grupos de mini-implante e Botão de Nance, foi utilizado o teste t de Student para medidas independentes. em todos os testes foi adotado nível de significância de 5% (p<0,05). CONCLUSÃO: ao se medir e comparar em modelos dentários a perda de ancoragem dos molares após a retração inicial de canino utilizando-se dois sistemas de ancoragem distintos (Mini-implante e Botão de Nance), pôde-se observar a inexistência de diferença estatisticamente significativa entre os dois grupos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: verificar se o mini-implante no palato é eficaz como ancoragem direta para distalização dos molares superiores. MÉTODOS: foi utilizado um modelo em acrílico da arcada superior. Após a confecção da canaleta na região correspondente aos alvéolos dentários, os dentes em acrílico foram fixados com cera #7, montado aparelho ortodôntico com a técnica Edgewise e inserido um mini-implante (SIN, São Paulo) no local correspondente à rafe palatina. Foram colocados arco 0,19" x 0,25" e barra transpalatina, soldados na barra dois ganchos para retenção de dois elásticos em cadeia de dois elos, a uma carga de 150g/f de cada lado (Unitek), que se estenderam dos ganchos até o mini-implante. O modelo da maxila foi mergulhado 40 vezes em banheira e fotografado após cada mergulho para observação da movimentação dentária. Os dados foram analisados pela análise da variânçia (ANOVA) e teste de Tukey. RESULTADOS: os molares deslocaram-se distalmente 3,1mm, em média, com inclinação distal entre 3 e 5mm. CONCLUÕES: a movimentação dos molares ocorreu pela inclinação distal, com leve rotação, mas sem efeito extrusivo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mini-implant insertion requires accurate surgical technique. This study shows an insertion technique using only tooth crown references; its scientific basis is evaluated radiographically. The sample consisted of 213 inter-radicular septa, evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width. The midpoint of the septum width was linked to the interdental contact point to determine septum midline. The distances from septum midline to "mesial and distal teeth were measured to evaluate the septum midline centralization degree in two different septum heights. The difference between mesial and distal distances represented the septum midline deviation degree. The mesial and distal distances were compared by t-tests, and the septum midline deviation was correlated with septum height using Pearson's correlation test. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. There was a moderate correlation (r = 0.45) between septum midline deviation and septum height. The tooth crown references evaluated on interproximal radiographs determine a high centralization degree of the septum midline on which the insertion site could be defined. The greater centralization degree was observed at the coronal septum area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate healing time before loading, areas compression and tension and location of insertion on mini-implant stability. Design: Six minipigs were used. Each animal received 3 mini-implants in each quadrant: 1 mini-implant was used as an unloaded control (G1, n = 24); the other 2 were loaded with 150 g-force at three time intervals (G2: immediate loading, G3: after 15 days and G4: after 30 days), with 16 mini-implant in each experimental group. After 120 days, tissue blocks of the areas of interest were harvested. Clinical analysis (exact Fisher test) determined the survival rate. Histological analysis (Kontron KS 300TM, Zeiss) quantified the fractional bone-toimplant contact (%BIC) and bone area (%BA) at each healing time point, areas of interest, and insertion site (ANOVA and t tests for dependent and independent samples). Results: The mini-implant survival rates were G1: 71%, G2: 50%, G3: 75% and G4: 63%, with no statistical differences between them. The groups presented similar %BIC and %BA. There were no differences between the compression and tension sides or maxillary and mandibular insertion sites. Conclusions: These results suggest that low-intensity immediate or early orthodontic loading does not affect mini-implant stability, because similar histomorphometric results were observed for all the groups, with partial osseointegration of the mini-implants present.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To determine (1) the optimal sites for mini-implant placement in the maxilla and the mandible based on dimensional mapping of the interradicular spaces and cortical bone thickness and (2) The effect of age and sex on the studied anatomic measurements. MATERIAL AND METHODS: The cone beam computed tomography images of 100 patients (46 males, 54 females) divided into two age groups (13-18 years), and (19-27 years) were used. The following interradicular measurements were performed: (1) Buccolingual bone thickness; (2) Mesiodistal spaces both buccally and palatally/lingually; and (3) Buccal and palatal/lingual cortical thicknesses. RESULTS: In the maxilla, the highest buccolingual thickness existed between first and second molars; the highest mesiodistal buccal/palatal distances were between the second premolar and the first molar. The highest buccal cortical thickness was between the first and second premolars. The highest palatal cortical thickness was between central and lateral incisors. In the mandible, the highest buccolingual and buccal cortical thicknesses were between the first and second molars. The highest mesiodistal buccal distance was between the second premolar and the first molar. The highest mesiodistal lingual distance was between the first and second premolars. The highest lingual cortical thickness was between the canine and the first premolar. The males and the older age group had significantly higher buccolingual, buccal, and palatal cortical thicknesses at specific sites and levels in the maxilla and the mandible. CONCLUSIONS: A clinical guideline for optimal sites for mini-implant placement is suggested. Sex and age affected the anatomic measurements in certain areas in the maxilla and the mandible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To estimate the applicability of potential sites for insertion of orthodontic mini-implants (OMIs) by a systematic review of studies that used computed tomography (CT) or cone beam CT to evaluate anatomical bone quality and quantity parameters, such as bone thickness, available space, and bone density.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To investigate the adequacy of potential sites for insertion of orthodontic mini-implants (OMIs) in the anterior alveolar region (delimited by the first premolars) through a systematic review of studies that used computed tomography (CT) or cone beam CT (CBCT) to assess anatomical hard tissue parameters, such as bone thickness, available space, and bone density. MATERIALS AND METHODS MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews were searched to identify all relevant papers published between 1980 and September 2011. An extensive search strategy was performed that included the key words "computerized (computed) tomography" and "mini-implants." Information was extracted from the eligible articles for three anatomical areas: maxillary anterior buccal, maxillary anterior palatal, and mandibular anterior buccal. Quantitative data obtained for each anatomical variable under study were evaluated qualitatively with a scoring system. RESULTS Of the 790 articles identified by the search, 8 were eligible to be included in the study. The most favorable area for OMI insertion in the anterior maxilla (buccally and palatally) and mandible is between the canine and the first premolar. The best alternative area in the maxilla (buccally) and the mandible is between the lateral incisor and the canine, while in the maxillary palatal area it is between the central incisors or between the lateral incisor and the canine. CONCLUSIONS Although there is considerable heterogeneity among studies, there is a good level of agreement regarding the optimal site for OMI placement in the anterior region among investigations of anatomical hard tissue parameters based on CT or CBCT scans. In this context, the area between the lateral incisor and the first premolar is the most favorable. However, interroot distance seems to be a critical factor that should be evaluated carefully.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJETIVO: este estudo teve como objetivo avaliar a influência da largura do septo inter-radicular no local de inserção de mini-implantes autoperfurantes sobre o grau de estabilidade desses dispositivos de ancoragem. MÉTODOS: a amostra consistiu de 40 mini-implantes inseridos entre as raízes do primeiro molar e segundo pré-molar superiores de 21 pacientes, com o intuito de fornecer ancoragem para retração anterior. A largura do septo no local de inserção (LSI) foi mensurada nas radiografias pós-cirúrgicas e, sob esse aspecto, os mini-implantes foram divididos em dois grupos: grupo 1 (áreas críticas, LSI<3mm) e grupo 2 (áreas não críticas, LSI>3mm). A estabilidade dos mini-implantes foi avaliada mensalmente pela quantificação do grau de mobilidade e a partir dessa variável foi calculada a proporção de sucesso. Avaliou-se também: a quantidade de placa, altura de inserção, grau de sensibilidade e período de observação. RESULTADOS: os resultados obtidos demonstraram que não houve diferença estatisticamente significativa para o grau de mobilidade e proporção de sucesso entre os mini-implantes inseridos em septos de largura mesiodistal crítica e não crítica. A proporção de sucesso total encontrada foi de 90% e nenhuma variável demonstrou estar relacionada ao insucesso dos mini-implantes. No entanto, observou-se maior sensibilidade nos pacientes cujos mini-implantes apresentavam mobilidade, e que a falha desses dispositivos de ancoragem ocorria logo após sua inserção. CONCLUSÃO: a largura do septo inter-radicular no local de inserção não interferiu na estabilidade dos mini-implantes autoperfurantes avaliados neste estudo.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study evaluated fracture torque by torsion, in relation to the length and diameter of orthodontic mini-implants, to demonstrate their viability for clinical and experimental use based on the torque recommended by the manufacturers. The fractures at the moment of insertion, whose incidence in the literature is around 4%, are principally due to excessive force and the inability of the implant to resist rotational forces. Thirty orthodontic mini-implants of three commercial brands available in Brazil (Neodent 1.6 x 9 mm, Dentoflex 1.6 x 9 mm and Kopp 1.6 x 9 mm) were attached to a device made specifically for this research, leaving the mini-implants with sufficient stability. The miniimplants were submitted to torsion torque, using a digital torque wrench, until their breaking point. The values obtained with the test were submitted to analysis of variance and the Tukey test. The mean values of mini-implant ruptures were 26 N.cm for group A (Dentoflex), 25.4 N. cm for group B (Kopp) and 32.8 N.cm for group C (Neodent). From the Tukey test we could observe that the relationships between the means of the Dentoflex and Neodent groups, and between the Kopp and Neodent groups, were significant. Between the Dentoflex and Kopp groups, significance was nonexistent. All the values found in our research for fracture torque were higher than the limits recommended by the manufacturers for clinical use in orthodontics. The highest values were found in the Neodent group.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

OBJETIVO: o propósito do presente estudo é avaliar o limite de resistência à flexão de um protótipo de mini-implante desenvolvido para ancoragem do aparelho de Herbst. MÉTODOS: após a realização de um cálculo do tamanho da amostra, quatro corpos de prova contendo os protótipos de mini-implantes foram submetidos a uma força de flexão por engastamento simples, utilizando-se uma máquina universal de ensaios mecânicos, sendo calculado o limite de resistência à força de flexão. RESULTADOS: após os ensaios mecânicos, os novos mini-implantes apresentaram o limite de resistência à força de flexão de 98,2kgf, que foi o menor valor encontrado. CONCLUSÃO: os protótipos de mini-implantes desenvolvidos para ancoragem do aparelho de Herbst foram capazes de suportar forças de flexão maiores do que as forças de mordida descritas na literatura.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar a distribuição de tensões na resina em contato com os filetes de roscas de mini-implantes cilíndricos e cônicos, submetidos à carga lateral e torção de inserção. Um modelo fotoelástico foi confeccionado com gelatina transparente, para simular o osso alveolar. O modelo foi observado com um polariscópio plano e fotografado antes e após a ativação dos mini-implantes com força lateral e de inserção. A aplicação de cargas laterais provocou momentos fletores nos mini-implantes, aparecimento de franjas isocromáticas ao longo dos filetes do corpo dos mini-implantes e no ápice. Quando foi aplicado o torque de inserção, verificou-se a concentração de tensões próxima ao ápice. Concluiu-se que: (1) o mini-implante cilíndrico apresentou maior concentração de tensões no ápice, e (2) o mini-implante cônico apresentou maior concentração de tensões nos filetes de rosca apicais.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objective: To describe the ultrastructure of the interface between periodontal tissues and titanium mini-implants in rat mandibles. Materials and Methods: A titanium mini-implant was placed between the buccal roots of the mandibular first molar of 24 adult rats. After 21, 30, 45, 60, 90, and 120 days of implantation, the mandibular portion was removed and fixed in cacodylate-buffered 2% glutaraldehyde + 2.5% formaldehyde. The material was decalcified and processed for scanning and transmission electron microscopy. Results: Ultrastructural analysis revealed a thin cementum-like layer at longer times after implantation at the areas in which the periodontal ligament was in contact with the implant. Conclusions: The alveolar bone and the periodontal ligament reorganized their constituents around the implant, and a thin cementum-like layer was formed at longer times after implantation at the areas in which the periodontal ligament was in contact with the implant. (Angle Orthod. 2010;80:459-435.)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The objective of this study was to evaluate the stress distribution in the resin in contact with the spirals of cylindrical and conical mini-implants, when submitted to lateral load and insertion torsion. A photoelastic model was fabricated using transparent gelatin to simulate the alveolar bone. The model was observed with a plane polariscope and photographically recorded before and after activation of the two screws with a lateral force and torsion. The lateral force application caused bending moments on both mini-implants, with the uprising of fringes or isochromatics, characteristics of stresses, along the threads of the mini-implants and in the apex. When the torsion was exerted in the mini-implants, a great concentration of stress upraised close to the apex. The conclusion was that, comparing conical with cylindrical mini-implants under lateral load, the stresses were similar on the traction sides. The differences appear (1) on the apex, where the cylindrical mini-implant showed a greater concentration of stress, and (2) along the spirals, in the compression side, where the conical mini-implant showed a greater concentration of stress. The greater part of the stress produced by both mini-implants, after torsion load in insertion, were concentrated on the apex. With the cylindrical mini-implant, the greater concentration of tension was close to the apex, while with the conical one, the stresses were distributed along a greater amount of apical threads.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Objectives: To compare autogenous bone (AT) and fresh-frozen allogeneic bone (AL) in terms of histomorphometrical graft incorporation and implant osseointegration after grafting for lateral ridge augmentation in humans. Materials and methods: Thirty-four patients were treated with either AL (20 patients) or AT (14 patients) onlay grafts. During implant installation surgery 6 months after grafting, cylindrical biopsies were harvested perpendicularly to the lateral aspect of the augmented alveolar ridge. Additionally, titanium mini-implants were installed in the grafted regions, also perpendicularly to the ridge; these were biopsied during second-stage surgery. Histological/histomorphometric analysis was performed using decalcified and non-decalcified sections. Results: Histological analysis revealed areas of necrotic bone (NcB) occasionally in contact with or completely engulfed by newly formed vital bone (VB) in both AT and AL groups (55.9 ± 27.6 vs. 43.1 ± 20.3, respectively; P = 0.19). Statistically significant larger amounts of VB (27.6 ± 17.5 vs. 8.4 ± 4.9, respectively; P = 0.0002) and less soft connective tissue (ST) (16.4 ± 15.6 vs. 48.4 ± 18.1, respectively; P ≤ 0.0001) were seen for AT compared with AL. No significant differences were observed between the groups regarding both bone-to-implant contact (BIC) and the bone area between implant threads (BA) on the mini-implant biopsies. Conclusion: Allogeneic bone block grafts may be an option in cases where a limited amount of augmentation is needed, and the future implant can be expected confined within the inner aspect of the bone block. However, the clinical impact of the relatively poor graft incorporation on the long-term performance of oral implants placed in AL grafts remains obscure. © 2013 John Wiley & Sons A/S.