14 resultados para microneedle
Resumo:
Intra-arterial (IA) injection represents an experimental avenue for minimally invasive delivery of stem cells to the injured brain. It has however been reported that IA injection of stem cells carries the risk of reduction in cerebral blood flow (CBF) and microstrokes. Here we evaluate the safety of IA neural progenitor cell (NPC) delivery to the brain. Cerebral blood flow of rats was monitored during IA injection of single cell suspensions of NPCs after stroke. Animals received 1 × 10(6) NPCs either injected via a microneedle (microneedle group) into the patent common carotid artery (CCA) or via a catheter into the proximally ligated CCA (catheter group). Controls included saline-only injections and cell injections into non-stroked sham animals. Cerebral blood flow in the microneedle group remained at baseline, whereas in the catheter group a persistent (15 minutes) decrease to 78% of baseline occurred (P<0.001). In non-stroked controls, NPCs injected via the catheter method resulted in higher levels of Iba-1-positive inflammatory cells (P=0.003), higher numbers of degenerating neurons as seen in Fluoro-Jade C staining (P<0.0001) and ischemic changes on diffusion weighted imaging. With an appropriate technique, reduction in CBF and microstrokes do not occur with IA transplantation of NPCs.
Resumo:
Delivery of large molecular weight biological molecules to the epidermis and dermis is constrained by the tough outer layer of the epidermis, the stratum corneum (sc). Microneedle technologies attempt to overcome this physical barrier using sharp micron-size projections to penetrate the sc. Dissolvable microneedles (DMN), are a particular microneedle design whereby the needle structure is composed of a soluble matrix that upon application to the skin, dissolves releasing the vaccine load into skin. This thesis examines (1) the formulation and processing considerations around DMN fabrication, (2) the immunogenicity of DMN containing trivalent influenza vaccine (TIV) in pre-clinical mouse and pig models and (3) the thermostability of these DMN formulations during storage. The results demonstrate the importance of formulation for microneedle formation and mechanical strength. Trehalose and polyvinylalcohol based formulations produced optimal microneedle structures and were amenable to piezoelectric dispensing; allowing for precise multi-layered DMN to be fabricated. The effect of drying conditions was assessed and found to be critical for DMN mechanical strength and skin penetration. The antibody responses to TIV generated by DMN-mediated vaccination were comparable or greater to those induced by immunization with a commercial TIV via the IM route in mice. DMN mediated immunisation resulted in a significantly broader humoral response to heterotypic influenza viruses compared to IM delivery. Stored at 40°C, a licensed seasonal influenza vaccine incorporated into DMN array was thermostable for at least 6 month as determined by Single Radial Immunodiffusion and immunogenicity in mice. The thesis advances the field of DMN influenza vaccination by elucidating important processing and formulation considerations in the fabrication of highly reproducible DMN. It also demonstrated that DMN can induce broader, larger humoral responses than conventional IM administration while demonstrating enhanced accelerated stability. Crucially, this works advances an automated fabrication system that will allow for clinical translation of DMN.
Resumo:
Microneedles (MNs) are emerging devices that can be used for the delivery of drugs at specific locations1. Their performance is primarily judged by different features and the penetration through tissue is one of the most important aspects to evaluate. For detailed studies of MN performance different kind of in-vitro, exvivo and in-vivo tests should be performed. The main limitation of some of these tests is that biological tissue is too heterogeneous, unstable and difficult to obtain. In addition the use of biological materials sometimes present legal issues. There are many studies dealing with artificial membranes for drug diffusion2, but studies of artificial membranes for Microneedle mechanical characterization are scarce3. In order to overcome these limitations we have developed tests using synthetic polymeric membranes instead of biological tissue. The selected artificial membrane is homogeneous, stable, and readily available. This material is mainly composed of a roughly equal blend of a hydrocarbon wax and a polyolefin and it is commercially available under the brand name Parafilm®. The insertion of different kind of MN arrays prepared from crosslinked polymers were performed using this membrane and correlated with the insertion of the MN arrays in ex-vivo neonatal porcine skin. The insertion depth of the MNs was evaluated using Optical coherence tomography (OCT). The implementation of MN transdermal patches in the market can be improved by make this product user-friendly and easy to use. Therefore, manual insertion is preferred to other kind of procedures. Consequently, the insertion studies were performed in neonatal porcine skin and the artificial membrane using a manual insertion force applied by human volunteers. The insertion studies using manual forces correlated very well with the same studies performed with a Texture Analyzer equipment. These synthetic membranes seem to mimic closely the mechanical properties of the skin for the insertion of MNs using different methods of insertion. In conclusion, this artificial membrane substrate offers a valid alternative to biological tissue for the testing of MN insertion and can be a good candidate for developing a reliable quality control MN insertion test.
Resumo:
A microwave (MW)-assisted crosslinking process to prepare hydrogel-forming microneedle (MN) arrays was evaluated. The effects of the crosslinking process on the MN arrays characteristics was evaluated. The results suggest that MN arrays prepared using the MW assisted process had equivalent properties to those prepared conventionally, but can be produced 30 times faster.
Resumo:
Pulsatile, or “on-demand”, delivery systems have the capability to deliver a therapeutic molecule at the right time/site of action and in the right amount (1). Pulsatile delivery systems present multiple benefits over conventional dosage forms and provide higher patient compliance. The combination of stimuli-responsive materials with the drug delivery capabilities of hydrogel-forming MN arrays (2) opens an interesting area of research. In the present work we describe, a stimuli-responsive hydrogel-forming microneedle (MN) array that enable delivery of a clinically-relevant model drug (ibuprofen) upon application of UV radiation (Figure 1A). MN arrays were prepared using a micromolding technique using a polymer prepared from 2-hydroxyethyl methacrylate (HEMA) and ethylene glycol dimethacrylate (EGDMA) (Figure 1B). The arrays were loaded with up to 5% (w/w) ibuprofen included in a light-responsible conjugate (3,5-dimethoxybenzoin conjugate) (2). The presence of the conjugate inside the MN arrays was confirmed by Raman spectroscopy measurements. MN arrays were tested in vitro showing that they were able to deliver up to three doses of 50 mg of ibuprofen after application of an optical trigger (wavelength of 365 nm) over a long period of time (up to 160 hours) (Figure 1C and 1D). The work presented here is a probe of concept and a modified version of the system should be used as UV radiation is shown to be the major etiologic agent in the development of skin cancers. Consequently, for future applications of this technology an alternative design should be developed. Based on the previous research dealing with hydrogel forming MN arrays a suitable strategy will be to use hydrogel-forming MN arrays containing a backing layer made with the material described in this work as the drug reservoir (2). Finally, a porous layer of a material that blocks UV radiation should be included between the MN array and the drug reservoir. Therefore radiation can be applied to the system without reaching the skin surface. Therefore after modification, the system described here interesting properties as “on-demand” release system for prolonged periods of time. This technology has potential for use in “on-demand” delivery of a wide range of drugs in a variety of applications relevant to enhanced patient care.
Resumo:
Dissolving polymeric microneedle arrays and hydrogel-forming microneedle arrays have attracted much attention during recent years due mainly to their biocompatibility and capacity for enhanced drug delivery. Nevertheless, for the production of this type of devices, typically, a drying step is required. Microneedles are prepared following a micromoulding technique using aqueous blends of Gantrez® S-97. Currently, production of microneedles arrays involves a long drying process of 48 hours. Therefore alternative drying methods were investigated including microwave radiation and hot air convection.
Resumo:
PURPOSE:
To evaluate the combination of a pressure-indicating sensor film with hydrogel-forming microneedle arrays, as a method of feedback to confirm MN insertion in vivo.
METHODS:
Pilot in vitro insertion studies were conducted using a Texture Analyser to insert MN arrays, coupled with a pressure-indicating sensor film, at varying forces into excised neonatal porcine skin. In vivo studies involved twenty human volunteers, who self-applied two hydrogel-forming MN arrays, one with a pressure-indicating sensor film incorporated and one without. Optical coherence tomography was employed to measure the resulting penetration depth and colorimetric analysis to investigate the associated colour change of the pressure-indicating sensor film.
RESULTS:
Microneedle insertion was achieved in vitro at three different forces, demonstrating the colour change of the pressure-indicating sensor film upon application of increasing pressure. When self-applied in vivo, there was no significant difference in the microneedle penetration depth resulting from each type of array, with a mean depth of 237 μm recorded. When the pressure-indicating sensor film was present, a colour change occurred upon each application, providing evidence of insertion.
CONCLUSIONS:
For the first time, this study shows how the incorporation of a simple, low-cost pressure-indicating sensor film can indicate microneedle insertion in vitro and in vivo, providing visual feedback to assure the user of correct application. Such a strategy may enhance usability of a microneedle device and, hence, assist in the future translation of the technology to widespread clinical use.
Resumo:
We analysed the use of microneedle-based electrodes to enhance electroporation of mouse testis with DNA vectors for production of transgenic mice. Different microneedle formats were developed and tested, and we ultimately used electrodes based on arrays of 500 μm tall microneedles. In a series of experiments involving injection of a DNA vector expressing Green Fluorescent Protein (GFP) and electroporation using microneedle electrodes and a commercially available voltage supply, we compared the performance of flat and microneedle electrodes by measuring GFP expression at various timepoints after electroporation. Our main finding, supported by both experimental and simulated data, is that needles significantly enhanced electroporation of testis.
Resumo:
Immunodiagnostic microneedles provide a novel way to extract protein biomarkers from the skin in a minimally invasive manner for analysis in vitro. The technology could overcome challenges in biomarker analysis specifically in solid tissue, which currently often involves invasive biopsies. This study describes the development of a multiplex immunodiagnostic device incorporating mechanisms to detect multiple antigens simultaneously, as well as internal assay controls for result validation. A novel detection method is also proposed. It enables signal detection specifically at microneedle tips and therefore may aid the construction of depth profiles of skin biomarkers. The detection method can be coupled with computerised densitometry for signal quantitation. The antigen specificity, sensitivity and functional stability of the device were assessed against a number of model biomarkers. Detection and analysis of endogenous antigens (interleukins 1α and 6) from the skin using the device was demonstrated. The results were verified using conventional enzyme-linked immunosorbent assays. The detection limit of the microneedle device, at ≤10 pg/mL, was at least comparable to conventional plate-based solid-phase enzyme immunoassays.
Resumo:
Photodynamic therapy (PDT) is used for skin treatments of premalignant and cancer lesions and recognized as a non-invasive technique that combines tissue photosensitization and subsequent exposure to light to induce cell death. However, it is limited to the treatment of superficial lesions, mainly due to the low cream penetration. Therefore, the improvement of transdermal distribution of aminolevulinic acid (ALA) is needed. In this study, the kinetics and homogeneity of production of ALA-induced PpIX after the skin pre-treatment with microneedles rollers of 0.5, 1.0 and 1.5 mm length were investigated. An improvement in homogeneity and production of PpIX was shown in a porcine model. Widefield fluorescence imaging three hours after the topical application of ALA-cream in the combined treatment with microeedles rollers.
Resumo:
A challenge in epidermal DNA vaccination is the efficient and targeted delivery of polynucleotides to immunologically sensitive Langerhans cells. This paper investigates this particular challenge for physical delivery approaches. The skin immunology and material properties are examined in the context of the physical cell targeting requirements of the viable epidermis. Selected current physical cell targeting technologies engineered to meet these needs are examined: needle and syringe; diffusion patches; liquid jet injectors; microneedle arrays/patches; and biolistic particle injection. The operating methods and relative performance of these approaches are discussed, with a comment on potential future developments and technologies. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
We analyze four extreme AGN transients to explore the possibility that they are caused by rare, high-amplitude microlensing events. These previously unknown type-I AGN are located in the redshift range 0.6-1.1 and show changes of > 1.5 magnitudes in the g-band on a timescale of ~years. Multi-epoch optical spectroscopy, from the William Herschel Telescope, shows clear differential variability in the broad line fluxes with respect to the continuum changes and also evolution in the line profiles. In two cases a simple point-source, point-lens microlensing model provides an excellent match to the long-term variability seen in these objects. For both models the parameter constraints are consistent with the microlensing being due to an intervening stellar mass object but as yet there is no confirmation of the presence of an intervening galaxy. The models predict a peak amplification of 10.3/13.5 and an Einstein timescale of 7.5/10.8 years respectively. In one case the data also allow constraints on the size of the CIII] emitting region, with some simplifying assumptions, to to be ~1.0-6.5 light-days and a lower limit on the size of the MgII emitting region to be > 9 light-days (half-light radii). This CIII] radius is perhaps surprisingly small. In the remaining two objects there is spectroscopic evidence for an intervening absorber but the extra structure seen in the lightcurves requires a more complex lensing scenario to adequately explain.
Resumo:
Antecedentes y objetivos: La hiperhidrosis primaria afecta el 2,8% de la población de Estados Unidos. Condición que impacta el desarrollo social de los individuos afectados, ocasionando fobia social. Existen opciones disponibles para el tratamiento de la hiperhidrosis incluyendo medicamentos tópico, sistémico, inyectable y quirúrgico. El objetivo de ésta revisión sistemática de la literatura es determinar la efectividad y seguridad de los dispositivos de emisión de microondas, radiofrecuencia no ablativa y sistema de ultrasonido microfocalizado para el tratamiento de la hiperhidrosis primaria. Materiales y métodos: Se realizó una revisión sistemática de la literatura de artículos obtenidos de bases de datos: Medline, Cochrane, Embase, Ovid y Scielo. Se incluyeron ensayos clínicos aleatorizados controlados, ensayos cuasiexperimentales desde el 2011; donde evaluaran el uso de estos dispositivos en el manejo de hiperhidrosis primaria. Resultados: Se seleccionaron 21 artículos en total. Se encontró que con los tres dispositivos se logra una reducción significativa a puntajes entre 1 y 2 de la escala de Severidad de la Hiperhidrosis; en 3 estudios se encontró mejoría en la calidad de vida; los eventos adversos fueron transitorios, siendo más frecuentes con el dispositivo de emisión de microondas. Conclusión: Primera revisión sistemática de la literatura sobre el efecto de estos tres dispositivos en el manejo de hiperhidrosis. Se espera aportar a la literatura existente una recomendación acerca de la efectividad y seguridad de estos dispositivos para que sea aplicado en los pacientes con diagnóstico de hiperhidrosis primaria.
Resumo:
Wearable biosensors are attracting interest due to their potential to provide continuous, real-time physiological information via dynamic, non-invasive measurements of biochemical markers in biofluids, such as interstitial fluid (ISF). One notable example of their applications is for glycemic monitoring in diabetic patients, which is typically carried out either by direct measurement of blood glucose via finger pricking or by wearable sensors that can continuously monitor glucose in ISF by sampling it from below the skin with a microneedle. In this context, the development of a new and minimally invasive multisensing tattoo-based platform for the monitoring of glucose and other analytes in ISF extracted through reverse iontophoresis in proposed by the GLUCOMFORT project. This elaborate describes the in-vitro development of flexible electrochemical sensors based on inkjet-printed PEDOT:PSS and metal inks that are capable of determining glucose and chloride at biologically relevant concentrations, making them good candidates for application in the GLUCOMFORT platform. In order to make PEDOT:PSS sensitive to glucose at micromolar concentrations, a biocompatible functionalization based on immobilized glucose oxidase and electrodeposited platinum was developed. This functionalization was successfully applied to bulk and flexible amperometric devices, the design of which was also optimized. Using the same strategy, flexible organic electrochemical transistors (OECTs) for glucose sensing were also made and successfully tested. For the sensing of chloride ions, an organic charge-modulated field-effect transistor (OCMFET) featuring a silver/silver chloride modified floating gate electrode was developed and tested.