951 resultados para linear quadratic control


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Linear quadratic stabilizers are well-known for their superior control capabilities when compared to the conventional lead-lag power system stabilizers. However, they have not seen much of practical importance as the state variables are generally not measurable; especially the generator rotor angle measurement is not available in most of the power plants. Full state feedback controllers require feedback of other machine states in a multi-machine power system and necessitate block diagonal structure constraints for decentralized implementation. This paper investigates the design of Linear Quadratic Power System Stabilizers using a recently proposed modified Heffron-Phillip's model. This model is derived by taking the secondary bus voltage of the step-up transformer as reference instead of the infinite bus. The state variables of this model can be obtained by local measurements. This model allows a coordinated linear quadratic control design in multi machine systems. The performance of the proposed controller has been evaluated on two widely used multi-machine power systems, 4 generator 10 bus and 10 generator 39 bus systems. It has been observed that the performance of the proposed controller is superior to that of the conventional Power System Stabilizers (PSS) over a wide range of operating and system conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Networked control systems (NCSs) have attracted much attention in the past decade due to their many advantages and growing number of applications. Different than classic control systems, resources in NCSs, such as network bandwidth and communication energy, are often limited, which degrade the closed-loop system performance and may even cause the system to become unstable. Seeking a desired trade-off between the closed-loop system performance and the limited resources is thus one heated area of research. In this paper, we analyze the trade-off between the sensor-to-controller communication rate and the closed-loop system performance indexed by the conventional LQG control cost. We present and compare several sensor data schedules, and demonstrate that two event-based sensor data schedules provide better trade-off than an optimal offline schedule. Simulation examples are provided to illustrate the theories developed in the paper. © 2012 AACC American Automatic Control Council).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper is concerned with the modelling of strategic interactions between the human driver and the vehicle active front steering (AFS) controller in a path-following task where the two controllers hold different target paths. The work is aimed at extending the use of mathematical models in representing driver steering behaviour in complicated driving situations. Two game theoretic approaches, namely linear quadratic game and non-cooperative model predictive control (non-cooperative MPC), are used for developing the driver-AFS interactive steering control model. For each approach, the open-loop Nash steering control solution is derived; the influences of the path-following weights, preview and control horizons, driver time delay and arm neuromuscular system (NMS) dynamics are investigated, and the CPU time consumed is recorded. It is found that the two approaches give identical time histories as well as control gains, while the non-cooperative MPC method uses much less CPU time. Specifically, it is observed that the introduction of weight on the integral of vehicle lateral displacement error helps to eliminate the steady-state path-following error; the increase in preview horizon and NMS natural frequency and the decline in time delay and NMS damping ratio improve the path-following accuracy. © 2013 Copyright Taylor and Francis Group, LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The standard linear-quadratic (LQ) survival model for external beam radiotherapy is reviewed with particular emphasis on studying how different schedules of radiation treatment planning may be affected by different tumour repopulation kinetics. The LQ model is further examined in the context of tumour control probability (TCP) models. The application of the Zaider and Minerbo non-Poissonian TCP model incorporating the effect of cellular repopulation is reviewed. In particular the recent development of a cell cycle model within the original Zaider and Minerbo TCP formalism is highlighted. Application of this TCP cell-cycle model in clinical treatment plans is explored and analysed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes a linear quadratic regulator with integral action, ensuring fast dynamic response and resisting capability of voltage deviation from instantaneous reference grid voltage, to control the inverter voltage that can also be used in a microgrid. The proposed control strategy is based on a linear quadratic regulator, minimizing the cost function of the system, with integral action used to impede voltage degradation from a reference voltage for outside disturbances of the system, such as abrupt load change. The combined integral term assists to recover the voltage difference between grid and reference grid voltage. The validity of the proposed controller has been tested with linear and non-linear loads under various conditions. In both cases, the effectiveness of the controller has been proved. The result of the proposed controller is good to track the instantaneous reference grid voltage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The linear quadratic Gaussian control of discrete-time Markov jump linear systems is addressed in this paper, first for state feedback, and also for dynamic output feedback using state estimation. in the model studied, the problem horizon is defined by a stopping time τ which represents either, the occurrence of a fix number N of failures or repairs (T N), or the occurrence of a crucial failure event (τ δ), after which the system paralyzed. From the constructive method used here a separation principle holds, and the solutions are given in terms of a Kalman filter and a state feedback sequence of controls. The control gains are obtained by recursions from a set of algebraic Riccati equations for the former case or by a coupled set of algebraic Riccati equation for the latter case. Copyright © 2005 IFAC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, an alternative apriori and aposteriori formulation has been derived for the discrete linear quadratic regulator (DLQR) in a manner analogous to that used in the discrete Kalman filter. It has been shown that the formulation seamlessly fits into the available formulation of the DLQR and the equivalent terms in the existing formulation and the proposed formulation have been identified. Thereafter, the significance of this alternative formulation has been interpreted in terms of the sensitivity of the controller performances to any changes in the states or to changes in the control inputs. The implications of this alternative formulation to adaptive controller tuning have also been discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this paper is to design and develop an optimal motion cueing algorithm (MCA) based on the genetic algorithm (GA) that can generate high-fidelity motions within the motion simulator's physical limitations. Both, angular velocity and linear acceleration are adopted as the inputs to the MCA for producing the higher order optimal washout filter. The linear quadratic regulator (LQR) method is used to constrain the human perception error between the real and simulated driving tasks. To develop the optimal MCA, the latest mathematical models of the vestibular system and simulator motion are taken into account. A reference frame with the center of rotation at the driver's head to eliminate false motion cues caused by rotation of the simulator to the translational motion of the driver's head as well as to reduce the workspace displacement is employed. To improve the developed LQR-based optimal MCA, a new strategy based on optimal control theory and the GA is devised. The objective is to reproduce a signal that can follow closely the reference signal and avoid false motion cues by adjusting the parameters from the obtained LQR-based optimal washout filter. This is achieved by taking a series of factors into account, which include the vestibular sensation error between the real and simulated cases, the main dynamic limitations, the human threshold limiter in tilt coordination, the cross correlation coefficient, and the human sensation error fluctuation. It is worth pointing out that other related investigations in the literature normally do not consider the effects of these factors. The proposed optimized MCA based on the GA is implemented using the MATLAB/Simulink software. The results show the effectiveness of the proposed GA-based method in enhancing human sensation, maximizing the reference shape tracking, and reducing the workspace usage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study presents a disturbance attenuation controller for horizontal position stabilisation for hover and automatic landings of a rotary-wing unmanned aerial vehicle (RUAV) operating close to the landing deck in rough seas. Based on a helicopter model representing aerodynamics during the landing phase, a non-linear state feedback H∞ controller is designed to achieve rapid horizontal position tracking in a gusty environment. Practical constraints including flapping dynamics, servo dynamics and time lag effect are considered. A high-fidelity closed-loop simulation using parameters of the Vario XLC gas-turbine helicopter verifies performance of the proposed horizontal position controller. The proposed controller not only increases the disturbance attenuation capability of the RUAV, but also enables rapid position response when gusts occur. Comparative studies show that the H∞ controller exhibits performance improvement and can be applied to ship/RUAV landing systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple linear ramp control circuit, suitable for use with force-commutated thyrister circuits is discussed here. The circuit is based on only two IM 558 dual timer iCs, operating from a single 15 V supply. The reset terminals facilitate inhibition of the output of any stage. The use of this circuit in a thyristor chopper operating at 400 Hz 13 described.