999 resultados para joint monitoring
Resumo:
In this article, we consider the synthetic control chart with two-stage sampling (SyTS chart) to control the process mean and variance. During the first stage, one item of the sample is inspected; if its value X, is close to the target value of the process mean, then the sampling is interrupted. Otherwise, the sampling goes on to the second stage, where the remaining items are inspected and the statistic T = Sigma [x(i) - mu(0) + xi sigma(0)](2) is computed taking into account all items of the sample. The design parameter is function of X-1. When the statistic T is larger than a specified value, the sample is classified as nonconforming. According to the synthetic procedure, the signal is based on Conforming Run Length (CRL). The CRL is the number of samples taken from the process since the previous nonconforming sample until the occurrence of the next nonconforming sample. If the CRL is sufficiently small, then a signal is generated. A comparative study shows that the SyTS chart and the joint X and S charts with double sampling are very similar in performance. However, from the practical viewpoint, the SyTS chart is more convenient to administer than the joint charts.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
OBJECTIVE To analyze strategies for self-management support by patients with stroke in the light of the methodology of the five A's (ask, advice, assess, assist and arrange). METHODS Integrative review conducted at the following databases CINAHL, SCOPUS, PubMed, Cochrane and LILACS. RESULTS A total of 43 studies published between 2000 and 2013 comprised the study sample. All proposed actions in the five A's methodology and others were included. We highlight the Assist and Arrange, in which we added actions, especially with regard to the use of technological resources and joint monitoring between patients, families and professionals. No study included all five A's, which suggests that the actions of supported self-management are developed in a fragmented way. CONCLUSION The use of five A's strategy provides guidelines for better management of patients with stroke with lower cost and higher effectiveness.
Resumo:
Bajo la tipología de estudio de caso, la presente investigación pretende explicar la influencia ejercida desde el Banco Mundial en la configuración de políticas públicas nacionales en Bolivia para la privatización del suministro, transporte y acceso al agua potable. El objetivo general de la investigación es explicar los alcances y limitaciones del modelo de privatización del agua en Bolivia como política pública, promovido por el Banco Mundial (BM), en la primera década del siglo XXI. Sosteniendo que el modelo de privatización del BM ha sido permeado y superado por el interés nacional del pueblo boliviano en materia de acceso al agua. Finalmente, la metodología empleada será de corte cualitativa a partir del análisis de documentos oficiales, textos académicos y científicos, legislaciones y disposiciones tomadas desde el BM y desde Bolivia en lo que respecta a la privatización del agua.
Resumo:
Polycyclic aromatic hydrocarbons (PAHs) are common environmental contaminants which can be derived from anthropogenic sources, such as combustion and discharges from extraction and transport, and natural processes, including leakage and erosion of fossil carbon. Natural PAH sources contribute, along with biological activities and terrestrial run-off, to the organic carbon content in sediments.The Barents Sea region is far from many anthropogenic sources of PAH, but production and trans-shipment of hydrocarbons is increasing. We present data for polycyclic aromatic hydrocarbon (PAH) concentrations in bottom sediments from 510 stations in the Barents and White Seas, and along the northern coast of Norway.
Resumo:
The T-2 and the generalized variance vertical bar S vertical bar charts are used for monitoring the mean vector and the covariance matrix of multivariate processes. In this article, we propose for bivariate processes the use of the T-2 and the VMAX charts. The points plotted on the VMAX chart correspond to the maximum of the sample variances of the two quality characteristics. The reason to consider the VMAX statistic instead of the generalized variance vertical bar S vertical bar is the user's familiarity with the computation of simple sample variances; we can't say the same with regard to the computation of the generalized variance vertical bar S vertical bar.
Resumo:
The present document has been elaborated in the context of the ERA-ARD project “The Agricultural Research for Development (ARD) dimension of the European Research Area (ERA) “. It is based on work done within Task 3.2 to identify a set of common or compatible methodologies for ARD planning, monitoring and evaluation and impact assessment. This set should serve as a guide for the management of joint ARD activities that are presently developed within the framework of the ERA-ARD project.
Resumo:
"Serial no. 97-N."
Resumo:
Este trabalho descreve a abordagem abrangente sobre a melhoria do sistema de gestão da qualidade na Unidade de Imagiologia do Hospital da Boavista através da implementação das normas de acreditação da Joint Commission International (JCI). Fundamental para a melhoria geral da qualidade é a redução contínua de riscos para os doentes e para os profissionais da Unidade. Tais riscos podem existir ao nível do ambiente físico assim como no circuito dos exames e dos doentes. A acreditação em Saúde é uma das prioridades estratégicas do Ministério da Saúde e tem como objetivo fortalecer a confiança dos cidadãos nos profissionais de saúde bem como nas instituições de saúde. É importante que Portugal cultive a melhoria da qualidade e segurança nas instituições de saúde mantendo uma relação adequada custo/benefício. A União Europeia tem feito um esforço para que a acreditação seja harmoniosa nos seus princípios, no entanto é respeitada sempre a prevalência da legislação de cada país, bem como as suas especificações culturais e religiosas (Shaw, 2006), responsabilizando-o pelo seu sistema de saúde O trabalho aqui apresentado tem como objetivo principal fundamentar a escolha do modelo de acreditação da JCI para o Hospital da Boavista, nomeadamente para a Unidade de Imagiologia, ver se os padrões estão de acordo com os procedimentos da Unidade, identificar falhas e apontar possiveis melhorias. Pretende-se ainda mostrar a importância da implementação dos sistemas de certificação e acreditação da gestão da qualidade, documentada pela experiência profissional, bem como o know-how do Hospital da Boavista, assim como a complementaridade dos programas da gestão da qualidade, certificação e acreditação. A escolha do modelo de acreditação da JCI, foi uma opção do Hospital da Boavista baseada na credibilidade e no grau de exigência que a entidade impõe. Foi imperativo que a Unidade de Imagiologia realizasse as suas funções de forma válida e fiável e que disponibilizasse produtos / serviços de qualidade. A monitorização e consequente controlo de qualidade do serviço prestado pela Unidade de Imagiologia, foi difícil mas simplificado, em parte, devido ao sistema de gestão da qualidade ISO 9001:2008 já implementado, tendo este sido consolidado com a implementação da acreditação da JCI, com padrões específicos bem definidos na gestão do controlo de qualidade na Unidade de Imagiologia do Hospital da Boavista.
Resumo:
1.Pre-assessment data of the patient A 2-year-old boy, weighing 15 kg was admitted with a history of limited mouth opening(inter-incisor distance of 6 mm), hypoplastic and retrognathic mandible (bird face deformity) and facial asymmetry from left temporomandibular joint ankylosis (TMJA). He was born at term, after an uneventful pregnancy, and there was no report of trauma during caesarean section. No other possible aetiologies were identified. He was scheduled for mandibular osteotomy. Preoperative ENT examination revealed adenotonsillar hypertrophy. 2. Anaesthetic Plan A fiberoptic nasal intubation was performed under deep inhalation anaesthesia with sevoflurane, with the patient breathing spontaneously. Midazolam (0.05 mg.kg-1) and alfentanil (0.03 mg.kg-1) were given and anaesthesia was maintained with O2/air and sevoflurane. No neuromuscular blocking agent was administered since the surgical team needed facial nerve monitoring. 3. Description of incident During surgery an accidental extubation occurred and an attempt was made to reintubate the trachea by direct laryngoscopy. Although the osteotomy was nearly completed, the vocal cords could not be visualized (Cormack-Lehane grade IV laryngoscopic view). 4. Solving the problem Re-intubation was finally accomplished with the flexible fiberscope and the procedure was concluded without any more incidents. Extubation was performed 24 hours postoperatively with the patient fully awake. After surgery mouth opening improved to inter-incisor gap of 15 mm. 5. Lessons learned and take home message Two airways issues present in this case can lead to difficultventilation and intubation: TMJA and adenotonsillar hypertrophy. These difficulties were anticipated and managed accordingly. The accidental extubation brought to our attention the fact that, even after surgical correction, this airway remains challenging. Even with intensive jaw stretchingexercises there is a high incidence of re-ankylosis, especially in younger patients. One should bear that in mind when anaesthetizing patients with TMJA.
Resumo:
This paper studies frequent monitoring in an infinitely repeated game with imperfect public information and discounting, where players observe the state of a continuous time Brownian process at moments in time of length _. It shows that a limit folk theorem can be achieved with imperfect public monitoring when players monitor each other at the highest frequency, i.e., _. The approach assumes that the expected joint output depends exclusively on the action profile simultaneously and privately decided by the players at the beginning of each period of the game, but not on _. The strong decreasing effect on the expected immediate gains from deviation when the interval between actions shrinks, and the associated increase precision of the public signals, make the result possible in the limit. JEL: C72/73, D82, L20. KEYWORDS: Repeated Games, Frequent Monitoring, Public Monitoring, Brownian Motion.
Oral cancer treatments and adherence: medication event monitoring system assessment for capecitabine
Resumo:
Background: Oncological treatments are traditionally administered via intravenous injection by qualified personnel. Oral formulas which are developing rapidly are preferred by patients and facilitate administration however they may increase non-adherence. In this study 4 common oral chemotherapeutics are given to 50 patients, who are still in the process of inclusion, divided into 4 groups. The aim is to evaluate adherence and offer these patients interdisciplinary support with the joint help of doctors and pharmacists. We present here the results for capecitabine. Materials and Methods: The final goal is to evaluate adhesion in 50 patients split into 4 groups according to oral treatments (letrozole/exemestane, imatinib/sunitinib, capecitabine and temozolomide) using persistence and quality of execution as parameters. These parameters are evaluated using a medication event monitoring system (MEMS®) in addition to routine oncological visits and semi-structured interviews. Patients were monitored for the entire duration of treatment up to a maximum of 1 year. Patient satisfaction was assessed at the end of the monitoring period using a standardized questionary. Results: Capecitabine group included 2 women and 8 men with a median age of 55 years (range: 36−77 years) monitored for an average duration of 100 days (range: 5-210 days). Persistence was 98% and quality of execution 95%. 5 patients underwent cyclic treatment (2 out of 3 weeks) and 5 patients continuous treatment. Toxicities higher than grade 1 were grade 2−3 hand-foot syndrome in 1 patient and grade 3 acute coronary syndrome in 1 patient both without impact on adherence. Patients were satisfied with the interviews undergone during the study (57% useful, 28% very useful, 15% useless) and successfully integrated the MEMS® in their daily lives (57% very easily, 43% easily) according to the results obtained by questionary at the end of the monitoring period. Conclusion: Persistence and quality of execution observed in our Capecitabine group of patients were excellent and better than expected compared to previously published studies. The interdisciplinary approach allowed us to better identify and help patients with toxicities to maintain adherence. Overall patients were satisfied with the global interdisciplinary follow-up. With longer follow up better evaluation of our method and its impact will be possible. Interpretation of the results of patients in the other groups of this ongoing trial will provide us information for a more detailed analysis.
Resumo:
Therapeutic drug monitoring (TDM), i.e., the quantification of serum or plasma concentrations of medications for dose optimization, has proven a valuable tool for the patient-matched psychopharmacotherapy. Uncertain drug adherence, suboptimal tolerability, non-response at therapeutic doses, or pharmacokinetic drug-drug interactions are typical situations when measurement of medication concentrations is helpful. Patient populations that may predominantly benefit from TDM in psychiatry are children, pregnant women, elderly patients, individuals with intelligence disabilities, forensic patients, patients with known or suspected genetically determined pharmacokinetic abnormalities or individuals with pharmacokinetically relevant comorbidities. However, the potential benefits of TDM for optimization of pharmacotherapy can only be obtained if the method is adequately integrated into the clinical treatment process. To promote an appropriate use of TDM, the TDM expert group of the Arbeitsgemeinschaft für Neuropsychopharmakologie und Pharmakopsychiatrie (AGNP) issued guidelines for TDM in psychiatry in 2004. Since then, knowledge has advanced significantly, and new psychopharmacologic agents have been introduced that are also candidates for TDM. Therefore the TDM consensus guidelines were updated and extended to 128 neuropsychiatric drugs. 4 levels of recommendation for using TDM were defined ranging from "strongly recommended" to "potentially useful". Evidence-based "therapeutic reference ranges" and "dose related reference ranges" were elaborated after an extensive literature search and a structured internal review process. A "laboratory alert level" was introduced, i.e., a plasma level at or above which the laboratory should immediately inform the treating physician. Supportive information such as cytochrome P450 substrateand inhibitor properties of medications, normal ranges of ratios of concentrations of drug metabolite to parent drug and recommendations for the interpretative services are given. Recommendations when to combine TDM with pharmacogenetic tests are also provided. Following the guidelines will help to improve the outcomes of psychopharmacotherapy of many patients especially in case of pharmacokinetic problems. Thereby, one should never forget that TDM is an interdisciplinary task that sometimes requires the respectful discussion of apparently discrepant data so that, ultimately, the patient can profit from such a joint effort.
Resumo:
A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.