996 resultados para interlaboratory comparison


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Results of an interlaboratory comparison on size characterization of SiO2 airborne nanoparticles using on-line and off-line measurement techniques are discussed. This study was performed in the framework of Technical Working Area (TWA) 34—“Properties of Nanoparticle Populations” of the Versailles Project on Advanced Materials and Standards (VAMAS) in the project no. 3 “Techniques for characterizing size distribution of airborne nanoparticles”. Two types of nano-aerosols, consisting of (1) one population of nanoparticles with a mean diameter between 30.3 and 39.0 nm and (2) two populations of non-agglomerated nanoparticles with mean diameters between, respectively, 36.2–46.6 nm and 80.2–89.8 nm, were generated for characterization measurements. Scanning mobility particle size spectrometers (SMPS) were used for on-line measurements of size distributions of the produced nano-aerosols. Transmission electron microscopy, scanning electron microscopy, and atomic force microscopy were used as off-line measurement techniques for nanoparticles characterization. Samples were deposited on appropriate supports such as grids, filters, and mica plates by electrostatic precipitation and a filtration technique using SMPS controlled generation upstream. The results of the main size distribution parameters (mean and mode diameters), obtained from several laboratories, were compared based on metrological approaches including metrological traceability, calibration, and evaluation of the measurement uncertainty. Internationally harmonized measurement procedures for airborne SiO2 nanoparticles characterization are proposed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the interlaboratory mass bias for high-precision stable Mg isotopic analysis of natural materials, a suite of silicate standards ranging in composition from felsic to ultramafic were analyzed in five laboratories by using three types of multicollector inductively coupled plasma mass spectrometer (MC-ICPMS). Magnesium isotopic compositions from all labs are in agreement for most rocks within quoted uncertainties but are significantly (up to 0.3 parts per thousand in Mg-26/Mg-24, > 4 times of uncertainties) different for some mafic samples. The interlaboratory mass bias does not correlate with matrix element/Mg ratios, and the mechanism for producing it is uncertain but very likely arises from column chemistry. Our results suggest that standards with different matrices are needed to calibrate the efficiency of column chemistry and caution should be taken when dealing with samples with complicated matrices. Well-calibrated standards with matrix elements matching samples should be used to reduce the interlaboratory mass bias.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

14 Laboratorien aus 12 europäischen Ländern nahmen an einer Laborvergleichsuntersuchung zur Stickstoffbestimmung in Fischerzeugnissen und Standardsubstanzen nach Kjeldahl teil. 13 Laboratorien erzielten dabei Ergebnisse, die alle in engen Grenzen um die gefundenen Mittelwerte streuten. Der von den einzelnen Teilnehmern erzielte Variationskoeffizient war mit etwa 0,5 % gering. Auch die Standardsubstanzen mit bekanntem Stickstoffgehalt konnten überwiegend mit hinreichender Genauigkeit (98 % der vom Hertsteller angegebenen Gehalte) analysiert werden. Der ideale Kjeldahlaufschluß ist durch kurze Aufschlußzeiten (ca. 120 min), eine Aufschlußtemperatur bei 430° C und durch die Wahl des für die jeweilige Matrix geeigneten Katalysators gekennzeichnet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An interlaboratory comparison (ILC) was conducted to evaluate the proficiency of multiple laboratories to quantify dimethylsulfide (DMS) in aqueous solution. Ten participating laboratories were each supplied with blind duplicate test solutions containing dimethylsulfoniopropionate hydrochloride (DMSP HCl) dissolved in acidified artificial seawater. The test solutions were prepared by the coordinating laboratory from a DMSP HCl reference material that was synthesized and purity certified for this purpose. A concentration range was specified for the test solutions and the participating laboratories were requested to dilute them as required for their analytical procedure, together with the addition of excess alkali under gas-tight conditions to convert the DMSP to DMS. Twenty-two DMS concentrations and their estimated expanded measurement uncertainties (95% confidence level) were received from the laboratories. With two exceptions, the within-laboratory variability was 5% or less and the between-laboratory variability was ~ 25%. The magnitude of expanded measurement uncertainties reported from all participants ranged from 1% to 33% relative to the result. The information gained from this pilot ILC indicated the need for further test sample distribution studies of this type so that participating laboratories can identify systematic errors in their analysis procedures and realistically evaluate their measurement uncertainty. The outcome of ILC studies provides insights into the comparability of data in the global surface seawater DMS database.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Within the framework of a European Union (EU) research project entitled

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The bacterium Coxiella burnetii, which has a wide host range, causes Q fever. Infection with C burnetii can cause abortions, stillbirth, and the delivery of weak offspring in ruminants. Coxiella burnetii infection is zoonotic, and in human beings it can cause chronic, potentially fatal disease. Real-time polymerase chain reaction (PCR) is increasingly being used to detect the organism and to aid in diagnosis both in human and animal cases. Many different real-time PCR methods, which target different genes, have been described. To assess the comparability of the C. burnetii real-time PCR assays in use in different European laboratories, a panel of nucleic acid extracts was dispatched to 7 separate testing centers. The testing centers included laboratories from both human and animal health agencies. Each laboratory tested the samples using their in-house real-time PCR methods. The results of this comparison show that the most common target gene for real-time PCR assays is the IS1111 repeat element that is present in multiple copies in the C. burnetii genome. Many laboratories also use additional real-time PCR tests that target single-copy genes. The results of the current study demonstrate that the assays in use in the different laboratories are comparable, with general agreement of results for the panel of samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Avidity tests can be used to discriminate between cattle that are acutely and chronically infected with the intracellular parasite Neospora caninum. The aim of this study was to compare the IgG avidity ELISA tests being used in four European laboratories. A coded panel of 200 bovine sera from well documented naturally and experimentally N. caninum infected animals were analysed at the participating laboratories by their respective assay systems and laboratory protocols. Comparing the numeric test results, the concordance correlation coefficients were between 0.479 and 0.776. The laboratories categorize the avidity results into the classes "low" and "high" which are considered indicative of recent and chronic infection, respectively. Three laboratories also use an "intermediate" class. When the categorized data were analysed by Kappa statistics there was moderate to substantial agreements between the laboratories. There was an overall better agreement for dichotomized results than when an intermediate class was also used. Taken together, this first ring test for N. caninum IgG avidity assays showed a moderate agreement between the assays used by the different laboratories to estimate the IgG avidity. Our experience suggests that avidity tests are sometimes less robust than conventional ELISAs. Therefore, it is essential that they are carefully standardised and their performance continuously evaluated.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Segundo O`Kane et al, em 2008, foi demonstrado que 88,9% dos erros laboratoriais são realizados na fase pré-analítica. No laboratório de análises clínicas, o sistema de controle da qualidade pode ser definido como toda a ação sistemática necessária para dar confiança e segurança em todos os exames e prevenir a ocorrência de erros. O tempo de armazenamento pode variar de dias a meses ou mesmo anos, influenciando na definição da temperatura de estocagem. O armazenamento de longo prazo pode resultar na criopreservação inadequada para determinados analitos e pode desnaturar as lipoproteínas. Objetivos: Este trabalho teve como objetivo avaliar a fase pré-analítica, controle da qualidade interno e também avaliar o efeito do congelamento (- 80C) quanto ao tempo de armazenamento do soro e plasma de sangue colhido com ácido etilenodiamino tetra-acético (EDTA). As dosagens foram realizadas no Laboratório de Lípides LabLip, e estocadas em - 80 C por três anos, as mesmas foram redosadas no Serviço de Patologia Clínica da Policlínica Piquet Carneiro da UERJ com metodologias iguais e realizada a comparabilidade dos resultados. Foram analisados o perfil lipídico (CT, HDLc e TG) e PCR-US de 103 amostras, 73 no soro e 30 no plasma em dois laboratórios altamente qualificados. Discussão: Após redosagem foram encontrados nas dosagens de HDLc e CT resultados diminuídos respectivamente (correlação coeficiente no soro 0,48 e 0,62) teste t pareado no soro (CT p 0,0012 e HDLc p 0,0001). Conclusões: Os dados obtidos nas avaliações dos resultados de diferentes laboratórios e tempo de estocagem revelaram que as amostras quando armazenadas por um longo período após redosagem no soro, apresentaram diferenças em certos analitos, tais como CT e HDLc, no qual obteve-se resultados significativamente diminuídos, diferentemente no plasma, que após três anos de estocagem a -80C foram redosados e aplicados no teste t pareado, os analitos CT e PCR-US mantiveram a estabilidade.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Recently, screening tests for monitoring the prevalence of transmissible spongiform encephalopathies specifically in sheep and goats became available. Although most countries require comprehensive test validation prior to approval, little is known about their performance under normal operating conditions. Switzerland was one of the first countries to implement 2 of these tests, an enzyme-linked immunosorbent assay (ELISA) and a Western blot, in a 1-year active surveillance program. Slaughtered animals (n = 32,777) were analyzed in either of the 2 tests with immunohistochemistry for confirmation of initial reactive results, and fallen stock samples (n = 3,193) were subjected to both screening tests and immunohistochemistry in parallel. Initial reactive and false-positive rates were recorded over time. Both tests revealed an excellent diagnostic specificity (>99.5%). However, initial reactive rates were elevated at the beginning of the program but dropped to levels below 1% with routine and enhanced staff training. Only those in the ELISA increased again in the second half of the program and correlated with the degree of tissue autolysis in the fallen stock samples. It is noteworthy that the Western blot missed 1 of the 3 atypical scrapie cases in the fallen stock, indicating potential differences in the diagnostic sensitivities between the 2 screening tests. However, an estimation of the diagnostic sensitivity for both tests on field samples remained difficult due to the low disease prevalence. Taken together, these results highlight the importance of staff training, sample quality, and interlaboratory comparison trials when such screening tests are implemented in the field.

Relevância:

60.00% 60.00%

Publicador: