994 resultados para injection methods


Relevância:

100.00% 100.00%

Publicador:

Resumo:

On-chip debug (OCD) features are frequently available in modern microprocessors. Their contribution to shorten the time-to-market justifies the industry investment in this area, where a number of competing or complementary proposals are available or under development, e.g. NEXUS, CJTAG, IJTAG. The controllability and observability features provided by OCD infrastructures provide a valuable toolbox that can be used well beyond the debugging arena, improving the return on investment rate by diluting its cost across a wider spectrum of application areas. This paper discusses the use of OCD features for validating fault tolerant architectures, and in particular the efficiency of various fault injection methods provided by enhanced OCD infrastructures. The reference data for our comparative study was captured on a workbench comprising the 32-bit Freescale MPC-565 microprocessor, an iSYSTEM IC3000 debugger (iTracePro version) and the Winidea 2005 debugging package. All enhanced OCD infrastructures were implemented in VHDL and the results were obtained by simulation within the same fault injection environment. The focus of this paper is on the comparative analysis of the experimental results obtained for various OCD configurations and debugging scenarios.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A method of injecting metallic elements into an electron-beam ion trap (EBIT) is described. The method is advantageous over the conventional coaxial and pulsed injection methods in two ways: (a) complicated switching of injection and extraction beams can be avoided when extracting beams of highly charged ions from the EBIT and (b) a beam of stable intensity can be achieved. This method may be applicable to any metallic elements or metallic compounds that have vapor pressures of similar to 0.1 Pa at a temperature lower than 1900 degrees C. We have employed this method for the extraction of highly charged ions of Bi, Er, Fe, and Ho. (c) 2006 American Institute of Physics.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

REASONS FOR PERFORMING STUDY: Proximal diffusion of local anaesthetic solution after perineural anaesthesia may lead to the desensitisation of structures other than those intended. However, there is no evidence-based study demonstrating the potential distribution and diffusion of local anaesthetic solution after perineural analgesia in the distal limb. OBJECTIVE: To document the potential diffusion of local anaesthetic solution using a radiopaque contrast model and to evaluate the influence of walking compared with confinement in a stable after injection. METHODS: Radiopaque contrast medium was injected subcutaneously over one palmar nerve at the base of the proximal sesamoid bones in 6 nonlame mature horses. Horses were assigned randomly to stand still or walk after injection. Radiographs were obtained 0, 5, 10, 15, 20 and 30 min after injection and were analysed to determine the distribution and diffusion of the contrast medium. RESULTS: In 89% of injections an elongated pattern of the contrast medium was observed suggesting distribution along the neurovascular bundle. After 49% of injections a fine radiopaque line extended proximally from the contrast 'patch', and in 25% of injections a line extended distally. There was significant proximal and distal diffusion with time when sequential radiographs of each limb were compared. The greatest diffusion occurred in the first 10 min. Walking did not significantly influence the extent of either proximal or distal diffusion. CONCLUSIONS AND POTENTIAL RELEVANCE: Significant proximal diffusion occurs in the first 10 min after perineural injection in the distal aspect of the limb and should be considered when interpreting nerve blocks. Distribution of local anaesthetic solution outside the fascia surrounding the neurovascular bundle or in lymphatic vessels may explain delayed or decreased effects.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A current injection pattern in Electrical Impedance Tomography (EIT) has its own current distribution profile within the domain under test. Hence, different current patterns have different sensitivity, spatial resolution and distinguishability. Image reconstruction studies with practical phantoms are essential to assess the performance of EIT systems for their validation, calibration and comparison purposes. Impedance imaging of real tissue phantoms with different current injection methods is also essential for better assessment of the biomedical EIT systems. Chicken tissue paste phantoms and chicken tissue block phantoms are developed and the resistivity image reconstruction is studied with different current injection methods. A 16-electrode array is placed inside the phantom tank and the tank is filled with chicken muscle tissue paste or chicken tissue blocks as the background mediums. Chicken fat tissue, chicken bone, air hole and nylon cylinders are used as the inhomogeneity to obtained different phantom configurations. A low magnitude low frequency constant sinusoidal current is injected at the phantom boundary with opposite and neighboring current patterns and the boundary potentials are measured. Resistivity images are reconstructed from the boundary data using EIDORS and the reconstructed images are analyzed with the contrast parameters calculated from their elemental resistivity profiles. Results show that the resistivity profiles of all the phantom domains are successfully reconstructed with a proper background resistivity and high inhomogeneity resistivity for both the current injection methods. Reconstructed images show that, for all the chicken tissue phantoms, the inhomogeneities are suitably reconstructed with both the current injection protocols though the chicken tissue block phantom and opposite method are found more suitable. It is observed that the boundary potentials of the chicken tissue block phantoms are higher than the chicken tissue paste phantom. SNR of the chicken tissue block phantoms are found comparatively more and hence the chicken tissue block phantom is found more suitable for its lower noise performance. The background noise is found less in opposite method for all the phantom configurations which yields the better resistivity images with high PCR and COC and proper IRMean and IRMax neighboring method showed higher noise level for both the chicken tissue paste phantoms and chicken tissue block phantoms with all the inhomogeneities. Opposite method is found more suitable for both the chicken tissue phantoms, and also, chicken tissue block phantoms are found more suitable compared to the chicken tissue paste phantom. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A novel Projection Error Propagation-based Regularization (PEPR) method is proposed to improve the image quality in Electrical Impedance Tomography (EIT). PEPR method defines the regularization parameter as a function of the projection error developed by difference between experimental measurements and calculated data. The regularization parameter in the reconstruction algorithm gets modified automatically according to the noise level in measured data and ill-posedness of the Hessian matrix. Resistivity imaging of practical phantoms in a Model Based Iterative Image Reconstruction (MoBIIR) algorithm as well as with Electrical Impedance Diffuse Optical Reconstruction Software (EIDORS) with PEPR. The effect of PEPR method is also studied with phantoms with different configurations and with different current injection methods. All the resistivity images reconstructed with PEPR method are compared with the single step regularization (STR) and Modified Levenberg Regularization (LMR) techniques. The results show that, the PEPR technique reduces the projection error and solution error in each iterations both for simulated and experimental data in both the algorithms and improves the reconstructed images with better contrast to noise ratio (CNR), percentage of contrast recovery (PCR), coefficient of contrast (COC) and diametric resistivity profile (DRP). (C) 2013 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Abrasion, feeding, injection and immersion methods were used to evaluate the pathogenicity of five different strains of Aeromonas hydrophila viz. RG (rui gill), ML (mrigal lesion), SG (sharpunti gill), F1K (mrigal kidney), GFL (gold fish lesion) and Ah-19 (Aeromonas hydrophila-19, Ref. Strain) against C. mrigala H. Bacterial suspension containing viable cells of 7.5x 10⁵ per ml was found to be very effective in intramuscular injection and feeding resulting 100% mortality after 96hr of inoculation. The strain RG, ML and F1K produced scale loss with erosion of the skin surface with/without hemorrhagic lesion after 48hr of inoculation following abrasion method. The strains SG and Ah-19 resulting scale loss with erosion of the skin surface with/without hemorrhagic lesion after 72hr of inoculation following abrasion and injection methods. SG and F1K caused reddening in mouth region after 72hr of feeding inoculation, whereas RG resulted frank ulcers from eroded dermal layer exposing underlying musculature which was hemorrhagic after 96hr of inoculation by abrasion method.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An on-line sample introduction technique in capillary gas chromatograph (CGC) for the analysis of high-pressure gas-liquid mixtures has been designed and evaluated. A sample loop of 0.05 muL and a washing solvent loop of 0.5 muL are mounted on a 10-port switching valve, which serves as the injection valve. A capillary resistor was connected to the vent of sample loop in order to maintain the pressure of the sample. Both the sample and the washing solvent are transferred into the split-injection port through a narrow bore fused silica capillary inserted into the injection liner through a septum. The volume of the liner is used both as the pressure-release damper and evaporation chamber of the sample. On-line analysis of both reactants and resultants in ethylene olimer reaction mixture at 5 MPa was carried out, which demonstrated the applicability of the technique. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Solid phase extraction (SPE) is a powerful technique for preconcentration/removal or separation of trace and ultra trace amounts of toxic and nutrient elements. SPE effectively simplifies the labour intensive sample preparation, increase its reliability and eliminate the clean up step by using more selective extraction procedures. The synthesis of sorbents with a simplified procedure and diminution of the risks of errors shows the interest in the areas of environmental monitoring, geochemical exploration, food, agricultural, pharmaceutical, biochemical industry and high purity metal designing, etc. There is no universal SPE method because the sample pretreatment depends strongly on the analytical demand. But there is always an increasing demand for more sensitive, selective, rapid and reliable analytical procedures. Among the various materials, chelate modified naphthalene, activated carbon and chelate functionalized highly cross linked polymers are most important. In the biological and environmental field, large numbers of samples are to be analysed within a short span of time. Hence, online flow injection methods are preferred as they allow extraction, separation, identification and quantification of many numbers of analytes. The flow injection online preconcentration flame AAS procedure developed allows the determination of as low as 0.1 µg/l of nickel in soil and cobalt in human hair samples. The developed procedure is precise and rapid and allows the analysis of 30 samples per hour with a loading time of 60 s. The online FI manifold used in the present study permits high sampling, loading rates and thus resulting in higher preconcentration/enrichment factors of -725 and 600 for cobalt and nickel respectively with a 1 min preconcentration time compared to conventional FAAS signal. These enrichment factors are far superior to hitherto developed on line preconcentration procedures for inorganics. The instrumentation adopted in the present study allows much simpler equipment and low maintenance costs compared to costlier ICP-AES or ICP-MS instruments.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective and design: Knowing that hyperglycemia is a hallmark of vascular dysfunction in diabetes and that neonatal streptozotocin-induced diabetic rats (n-STZ) present reduced inflammatory response, we decided to evaluate the effect of chlorpropamide-lowered blood glucose levels on carrageenan-induced rat paw edema and pleural exudate in n-STZ. Materials: Diabetes was induced by STZ injection (160 mg/kg, ip) in neonates (2-day-old) Wistar rats. Treatment: n-STZ diabetic rats were treated with chlorpropamide (200 mg/kg, 15 d, by gavage) 8 weeks after STZ injection. Methods: Carrageenan-induced paw edema and pleural exudate volumes were assessed concomitantly with peripheral and exudate leukocyte count. We also evaluated the expression of inducible nitric oxide synthase (iNOS) in lungs of all experimental groups. Results: Chlorpropamide treatment improved glucose tolerance, beta-cell function (assessed by HOMA-beta), corrected paw edema, and pleural exudate volume in n-STZ. Neither leukocyte count nor iNOS expression were affected by diabetes or by chlorpropamide treatment. Conclusion: Chlorpropamide treatment by restoring beta-cell function, reducing blood sugar levels, and improving glucose tolerance might be contributing to the correction of the reduced inflammatory response tested as paw edema and pleural exudate in n-STZ diabetic rats.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A new compact system encompassing in flow gas diffusion unit and a wall-jet amperometric FIA detector, coated with a supramolecular porphyrin film, was specially designed as an alternative to the time-consuming Monier-Williams method, allowing fast, reproducible and accurate analyses of free sulphite species in fruit juices. In fact, a linear response between 0.64 and 6.4 ppm of sodium sulphite. LOD = 0.043 ppm, relative standard deviation of +/- 1.5% (n = 10) and analytical frequency of 85 analyses/h were obtained utilising optimised conditions. That superior analytical performance allows the precise evaluation of the amount of free sulphite present in foods, providing an important comparison between the standard addition and the standard injection methods. Although the first one is most frequently used, it was strongly influenced by matrix effects because of the unexpected reactivity of sulphite ions with the juice matrixes, leading to its partial consumption soon after addition. In contrast, the last method was not susceptible to matrix effects yielding accurate results, being more reliable for analytical purposes. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose. There is considerable evidence that cellular oxidative stress caused by hyperglycemia plays an important role in the genesis and evolution of chronic diabetic lesions. In this study, we determined the effectiveness of pancreas transplantation (PT) in preventing the imbalance caused by excessive production of reactive oxygen species over antioxidant defenses in lungs of rats rendered diabetic by alloxan injection.Methods. Sixty inbred male Lewis rats, weighing 250-280 g, were randomly assigned to 3 experimental groups: NC, 20 nondiabetic control rats; DC, 20 untreated diabetic control rats; and PT, 20 diabetic rats that received syngeneic PT from normal donor Lewis rats. Each group was further divided into 2 subgroups of 10 rats each which were killed after 4 and 12 weeks of follow-up. Plasma glucose, glycosylated hemoglobin, and insulin levels were determined in all rats. Lipid hydroperoxide (LPO) concentrations and enzyme activities of superoxide dismutase (SOD), catalase (CAT), and glutathione peroxidase (GSH-Px) were measured in the pulmonary tissue of all rats.Results. The DC rats showed elevated blood glucose and glycosylated hemoglobin levels, with insulin blood levels significantly lower than the NC rats (P < .001). They also showed significantly increased LPO concentrations in the lungs (P < .01) after 4 and 12 weeks of follow-up. In contrast, SOD, CAT, and GSH-Px antioxidant activities were significantly reduced in these periods (P < .01) 12 weeks after diabetes induction. Successful PT corrected all clinical and metabolic changes in the diabetic rats, with sustained normoglycemia throughout the study. Excessive lung LPO production and low SOD, CAT, and GSH-Px antioxidant activities were already back to normal 4 weeks after PT.Conclusion. PT can control oxidative stress in pulmonary tissue of diabetic rats. It may be the basis for preventing chronic diabetic lesions in lungs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To report a case of idiopathic macular hole, with vitreoretinal traction confirmed by optical coherence tomography that was successfully treated by a single intravitreous perfluoropropane (C3F8) gas bubble injection.METHODS: Case report. A 65-year-old patient with idiopathic macular hole (stage 2, one eye) received an intravitreous gas injection and was prospectively followed with optical coherence tomography.RESULTS: A complete posterior vitreous detachment was achieved within 6 weeks after gas injection. Visual acuity improved from 20/80 to 20/25 by 10 months of followup. Optical coherence tomography disclosed vitreoretinal traction release and macular hole closure. No complications were related to the procedure.CONCLUSION: This simple procedure can assist a complete posterior vitreous detachment with relief of the hyaloid-foveolar traction, facilitating macular hole closure. (C) 2001 by Elsevier Science Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Il tomografo sonico è uno strumento di recente applicazione nell’analisi morfo-sintomatica delle alberature. Si tratta di uno strumento che sfrutta la propagazione delle onde sonore nel legno per determinarne la densità e le possibili alterazioni interne. Oltre all’applicazione su larga scala in un parco di Imola, per effettuare una valutazione approfondita di tutti gli esemplari, lo strumento è stato applicato per scopi diversi. In prima analisi è stato utilizzato per valutare stadi precoci di alterazione e l’evoluzione delle patologie interne nel tempo. Successivamente si voleva identificare il percorso di sostanze liquide iniettate con mezzi endoterapici nel tronco, attraverso l’applicazione di tomografia sonica sopra e sotto il punto di iniezione. In ultima analisi è stato effettuato un confronto tra tomografia sonica e risonanza magnetica nucleare per identificare patologie invisibili ai normali strumenti utilizzati nell’analisi della stabilità delle piante.