999 resultados para indirect diagnosis
Resumo:
Hemophilia A is an X-linked, inherited, bleeding disorder caused by the partial or total inactivity of the coagulation factor VIII (FVIII). Due to difficulties in the direct recognition of the disease-associated mutation in the F8 gene, indirect diagnosis using polymorphic markers located inside or close to the gene is used as an alternative for determining the segregation of the mutant gene within families and thus for detecting carrier individuals and/or assisting in prenatal diagnosis. This study characterizes the allelic and haplotype frequencies, genetic diversity, population differentiation and linkage disequilibrium of five microsatellites (F8Int1, F8Int13, F8Int22, F8Int25.3 and IKBKG) in samples of healthy individuals from Sao Paulo, Rio Grande do Sul and Pernambuco and of patients from Sao Paulo with haemophilia A to determine the degree of informativeness of these microsatellites for diagnostic purposes. The interpopulational diversity parameters highlight the differences among the analyzed population samples. Regional differences in allelic frequencies must be taken into account when conducting indirect diagnosis of haemophilia A. With the exception of IKBKG, all of the microsatellites presented high heterozygosity levels. Using the markers described, diagnosis was possible in 10 of 11 families. The F8Int22, F8Int1, F8Int13, F8Int25.3 and IKBKG microsatellites were informative in seven, six, five and two of the cases, respectively, demonstrating the effectiveness of using these microsatellites in prenatal diagnosis and in carrier identification in the Brazilian population.
Resumo:
Este estudo teve como objetivo produzir um antígeno (Ag) a partir de cultura de células de membrana sinovial caprina (MSC) infectadas com o vírus de artrite encefalite caprina (CAEV), pela técnica de microfiltração seriada, substituindo a ultracentrifugação em colchão de sacarose (UCCS) para utilização em ELISA indireto (ELISA-i). Amostras de 188 soros caprinos, que previamente foram testados pelo Western blot (WB) com Ag UCCS, foram submetidas à análise pelo ELISA-i com o novo antígeno produzido, que mostrou concordância de 92% em relação ao antígeno UCCS. A sensibilidade e a especificidade do ELISA em relação ao WB foram de 95,6% e 88,5%, respectivamente. A nova técnica, criada a partir de microfiltrações, mostrou-se efetiva e de baixo custo para o diagnóstico sorológico de anticorpos para CAEV em comparação ao antígeno ultracentrifugado, e constitui uma alternativa viável para produção de antígeno purificado de lentivírus de pequenos ruminantes.
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Using BCG, MPT-51 and Ag85 as antigens in an indirect ELISA for the diagnosis of bovine tuberculosis
Resumo:
This study evaluated the Mycobacterium tuberculosis protein antigen MPT-51, the trimeric antigen 85 (Ag85) complex, and Bacillus Calmette-Guerin (BCG) in an indirect ELISA to diagnose bovine tuberculosis (TB) from serum samples. Serum was collected from 208 intra-dermal tuberculin test (ITT)-positive and 54 ITT-negative animals from a region where bovine TB is endemic. Using the Ag85 and BCG antigens, the indirect ELISA was able to discriminate ITT-positive from ITT-negative animals. This level of discrimination was not achieved when using the MPT-51 antigen. The highest sensitivity (Se) and specificity (Sp) of the test was found when BCG was used (Se, 82%; Sp, 91%). Further work in different epidemiological settings and with larger numbers of animals will be required to validate these findings. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
Crude Toxoplasma gondii antigens represent raw material used to prepare reagents to be employed in different serologic tests for the diagnosis of toxoplasmosis, including the IgM and IgG indirect hemagglutination (IgG-HA and IgM-HA) tests. So far, the actual antigenic molecules of the parasite involved in the interaction with agglutinating anti-T. gondii antibodies in these tests are unknown. The absorption process of serum samples from toxoplasmosis patients with the IgG-HA reagent (G-toxo-HA) demonstrated that red cells from this reagent were coated with T. gondii antigens with Mr of 39, 35, 30, 27, 22 and 14 kDa. The immune-absorption process with the IgM-HA reagent (M-toxo-HA), in turn, provided antibody eluates which recognized antigenic bands of the parasite corresponding to Mr of 54, 35 and 30 kDa, implying that these antigens are coating red cells from this reagent. The identification of most relevant antigens for each type of HA reagent seems to be useful for the inspection of the raw antigenic material, as well as of reagent batches routinely produced. Moreover the present findings can be used to modify these reagents in order to improve the performance of HA tests for the diagnosis of toxoplasmosis
Resumo:
Toxocariasis is caused by infection of man by Toxocara canis and Toxocara cati larvae, the common roundworm of dogs and cats. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. Non specific reactions are observed mainly due to cross-reactivity with Ascaris sp antigens. This investigation aimed at developing and evaluating an indirect antibody competition ELISA (IACE) employing a specific rabbit IgG anti-Toxocara canis excretory-secretory antigens as the competition antibody, in order to improve indirect ELISA specificity performed for toxocariasis diagnosis. For that, the rabbit IgG was previously absorbed by Ascaris suum adult antigens. Sensitivity and specificity of IACE were first evaluated in 28 serum samples of mice experimentally infected with T. canis embryonated eggs. Adopting cut-off value established in this population before infection, sensitivity and specificity were 100% after 20 days post-inoculation. For human population IACE was evaluated using sera from 440 patients with clinical signs of toxocariasis and the cut-off value was established with 60 serum samples from apparently healthy individuals. Using as reference test the indirect ELISA performed by Adolfo Lutz Institute, sensitivity was 60.2%, specificity was 98% and concordance was 77.3%. Repeatability of IACE was evaluated by the inter-reactions variation coefficient (2.4%).
Resumo:
We compared the indirect immunofluorescence assay (IFA) with Western blot (Wb) as a confirmatory method to detect antibodies anti retrovirus (HIV-1 and HTLV-I/II). Positive and negative HIV-1 and HTLV-I/II serum samples from different risk populations were studied. Sensitivity, specificity, positive, negative predictive and kappa index values were assayed, to assess the IFA efficiency versus Wb. The following cell lines were used as a source of viral antigens: H9 ( HTLV-III b); MT-2 and MT-4 (persistently infected with HTLV-I) and MO-T (persistently infected with HTLV-II). Sensitivity and specificity rates for HIV-1 were 96.80% and 98.60% respectively, while predictive positive and negative values were 99.50% and 92.00% respectively. No differences were found in HIV IFA performance between the various populations studied. As for IFA HTLV system, the sensitivity and specificity values were 97.91% and 100% respectively with positive and negative predictive values of 100% and 97.92%. Moreover, the sensitivity of the IFA for HTLV-I/II proved to be higher when the samples were tested simultaneously against both antigens (HTLV-I-MT-2 and HTLV-II-MO-T). The overall IFA efficiency for HIV-1 and HTLV-I/II-MT-2 antibody detection probed to be very satisfactory with an excellent correlation with Wb (Kappa indexes 0.93 and 0.98 respectively). These results confirmed that the IFA is a sensitive and specific alternative method for the confirmatory diagnosis of HIV-1 and HTLV-I/II infection in populations at different levels of risk to acquire the infection and suggest that IFA could be included in the serologic diagnostic algorithm.
Resumo:
Using the indirect hemagglutination (IH), indirect immunofluorescence (IIF) and enzyme linked immunosorbent assay (ELISA) tests for the diagnosis of Chagas disease, 4000 serum samples were examined. This study was conducted with different purposes: clinical interest, research support and parasitological monitoring of those patients with Chagas disease who were treated with heart transplantations. The tests occurred without patient selection and in accordance with the medical requests. The results showed discrepancies and brought about several questions, considering the different results that all three methods showed when considered together. What was found brought about concerns and we suggest the adoption of different measures, aiming to avoid these mismatches in the context of this disease.
Resumo:
Clinical and serological follow-up of 7 patients submitted to renal transplantation and presenting positive serological reactions to Chagas 'disease before immunossupression did not show significant changes in indirect immunofluorescence and complement fixation titres for Chagas ' disease, or signs and symptoms indicating exacerbation of the disease during follow- up. In addition, 18 of 66 recipients of renal transplants considered to be non-chagasic before immunosuppression showed at least one positive result to the indirect immunofluorescence test for Chagas ' disease during the study period. The results suggest that the immunosuppression State induced in chagasic patients submitted to renal transplant did notpromoted exacerbation of the chronic infection in these patients and not interfere with the serological response of chronic chagasics, thus permitting the use of these serologic reactions for diagnostic purposes in these cases. However, the positive results ofthe indirect immunofluorescence test in non- chagasic patients indicate the needforjudicious interpretation ofthe indirect immunofluorescence test for the diagnosis of Chagas' disease in renal transplanted patients.
A contribution to the diagnosis of Capillaria hepatica infection by indirect immunofluorescence test
Resumo:
A highly specific pattern of immunofluorescence was noted when sera from Capillaria hepatica-infected rats were tested against the homologous worms and eggs present either in paraffin or cryostat sections from mouse liver. The pattern was represented by a combined apple green fluorescence of the internal contents of worms and eggs, which persisted in serum-dilutions of 1:400 up to 1:1600. Unequivocal fluorescent pattern was observed from 15 days up to 3 months following inoculation of rats with embryonated C. hepatica eggs and such result was confirmed by the ELISA. After the 4th month of infection, the indirect immunofluorescence test turned negative, probably revealing the extinction of parasitism, however the ELISA was contradictory, disclosing high levels of antibodies in this period . The IIF was also negative when control normal rat sera and sera from rats administered by gavage with immature C. hepatica eggs (spurious infection), or for reactions made against Schistosoma mansoni eggs, although a weakly positive pattern occurred with Fasciola hepatica eggs. The indirect immunofluorescence test may be recommended for use with human sera to detect early C. hepatica infection in special clinical instances and in epidemiological surveys, since it is a simple, inexpensive, and reliable test, presenting excellent sensitivity and specificity. Although the diagnosis is positive only during early infection, this is the period when the symptoms are usually more severe and the need for differential diagnosis is greater.
Resumo:
Abdominal angiostrongyliasis is a potentially fatal zoonotic disease with a broad geographical distribution throughout Central and South America. This study assessed the performance of Angiostrongylus costaricensis eggs as the antigen in an indirect immunofluorescence assay for the determination of parasite-specific IgG and IgG1 antibodies. For prevalence studies, an IgG antibody titre > 16 was identified as the diagnostic threshold with the best performance, providing 93.7% sensitivity and 84.6% specificity. Cross reactivity was evaluated with 65 additional samples from patients with other known parasitic infections. Cross reactivity was observed only in samples from individuals infected with Strongyloides stercoralis. For clinical diagnosis, we recommend the determination of IgG only as a screening test. IgG1 determination may be used to increase the specificity of the results for patients with a positive screening test.
Resumo:
An indirect enzyme linked immunoassay (ELISA-I) was developed and standardized for the serological diagnosis of classical swine fever (CSF). For the comparison, nine hundred and thirty-seven swine serum samples were tested by serum neutralization followed by immunoperoxidase staining (NPLA), considered as the standard. Of these, 223 were positive and 714 negative for neutralizing antibodies to classical swine fever virus (CSFV). In relation to the NPLA, the ELISA-I presented a 98.2% sensitivity; 92.86% specificity, 81.11% positive predictive value, 99.4% negative predictive value and a 94.1% precision. Statistical analysis showed a very strong correlation (r=0,94) between both tests. When compared to a commercially available ELISA kit, the performance of both, in relation to the NPLA, was similar. It was concluded that the ELISA-I is suitable for large scale screening of antibodies to classical swine fever virus, although it does not distinguish antibodies to classical swine fever virus from those induced by other pestiviruses.
Resumo:
Taenia solium cysticercosis is still a serious public health problem in several countries where poverty and lack of hygiene favor transmission. Because pigs are the primary intermediate hosts, prevalence of porcine cysticercosis is a reliable indicator of active transmission zones. Serological diagnostic methods are important tools for epidemiological studies since they can be applied to living animals on a large scale. Four antigen preparations (cyst fluid and crude) from T. solium and T. crassiceps metacestodes were compared for swine cysticercosis diagnosis by indirect ELISA (IE). Twenty-eight serum samples from swine naturally and experimentally infected by cysticerci of T. solium and 56 serum samples from swine reared in commercial herds were tested. Best results of overall sensitivity were obtained by the use of cyst fluid and crude antigen of T. crassiceps metacestode (100 and 96.4%, respectively). Using homologous antigen preparations we have observed higher specificity percentage (98.2% for cyst fluid and 96.4% for crude metacestode T. solium antigen). We concluded that sensitivity is of far more importance than specificity for identification of endemic areas in order to prevent transmission to man. We conclude, therefore, that IE performed with cyst fluid antigen of T. crassiceps metacestode is a better tool for that purpose. (C) 2000 Elsevier B.V. B.V. All rights reserved.
Resumo:
Two rapid tests evaluated in dogs considered to be of high risk of Infection with the Chagas parasite Trypanosoma cruzi using two immunochromatographic assays. Trypanosoma Detect (TM) for canine, InBios, Seattle, WA and CHAGAS STAT-PAK (TM) assay, Chembio Diagnostic Systems, Medford, NY, in south central Louisiana. For this purpose a serological survey was carried out in a total of 122 dogs and a serum bank was created. These 122 animals were first tested by IFAT that was used as the standard test From the serum bank 50 samples were tested using the two rapid Chagas assays and results compared to the standard test IFAT The serological survey using IFAT showed it prevalence of T cruzi infection in 22.1% of the tested dogs. In the immunochromatographic assays. 13 and 11 animals were positive on rapid assay Trypanosoma Detect (TM) for canine, InBios and CHAGAS STAT-PAK (TM), Chembio Diagnostic Systems, respectively compared to 11 positive by IFAT. These two immunochromatographic tests have shown high susceptibility and specificity compared to our standard method IFAT. The rapid, easy and accurate screening assays used in conjunction with confirmatory tests, would be an excellent tool for veterinarians to diagnose T cruzi infection. Early detection of T cruzi infection may prevent complications through an effective treatment. Greater awareness by veterinarians of the risk. clinical findings, history along with diagnostic methods will contribute greatly to an understanding of the true prevalence of Chagas disease in dogs in Louisiana. (c) 2009 Elsevier B.V. All rights reserved.
Resumo:
Toxocariasis is caused by infection of man by Toxocara canis and Toxocara, cati larvae, the common roundworm of dogs and cats. Because larvae are difficult to detect in tissues, diagnosis is mostly based on serology. Non specific reactions are observed mainly due to cross-reactivity with Ascaris sp antigens. This investigation aimed at developing and evaluating an indirect antibody competition ELISA (IACE) employing a specific rabbit IgG anti-Toxocara canis excretory-secretory antigens as the competition antibody. in order to improve indirect ELISA specificity performed for toxocariasis diagnosis. For that, the rabbit IgG was previously absorbed by Ascaris suum adult antigens. Sensitivity and specificity of IACE were first evaluated in 28 serum samples of mice experimentally infected with T. canis embryonated eggs. Adopting cut-off value established in this population before infection, sensitivity and specificity were 100% after 20 days post-inoculation. For human population IACE was evaluated using sera from 440 patients with clinical signs of toxocariasis and the cut-off value was established with 60 serum samples from apparently healthy individuals. Using as reference test the indirect ELISA performed by Adolfo Lutz Institute, sensitivity was 60.2%, specificity was 98% and concordance was 77.3%. Repeatability of IACE was evaluated by the inter-reactions variation coefficient (2.4%).