985 resultados para hologram recording


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new polymer matrix sensitized with methylene blue for use as an optical recording material is described here. The characterization is done to determine the optimal recording conditions. These films need no chemical development and are found to be stable for several months. The matrix has excellent shelf life and needs an exposure only as short as 20 s. Direct imaging was done on this material.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Different interferometric techniques were developed last decade to obtain full field, quantitative, and absolute phase imaging, such as phase-shifting, Fourier phase microscopy, Hilbert phase microscopy or digital holographic microscopy (DHM). Although, these techniques are very similar, DHM combines several advantages. In contrast, to phase shifting, DHM is indeed capable of single-shot hologram recording allowing a real-time absolute phase imaging. On the other hand, unlike to Fourier phase or Hilbert phase microscopy, DHM does not require to record in focus images of the specimen on the digital detector (CCD or CMOS camera), because a numerical focalization adjustment can be performed by a numerical wavefront propagation. Consequently, the depth of view of high NA microscope objectives is numerically extended. For example, two different biological cells, floating at different depths in a liquid, can be focalized numerically from the same digital hologram. Moreover, the numerical propagation associated to digital optics and automatic fitting procedures, permits vibrations insensitive full- field phase imaging and the complete compensation for a priori any image distortion or/and phase aberrations introduced for example by imperfections of holders or perfusion chamber. Examples of real-time full-field phase images of biological cells have been demonstrated. ©2008 COPYRIGHT SPIE

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The measurement of the phase shift φ between the transmited and difracted beams interfering along the same direction behind the hologram recorded in a photorefractive crystal is directly and accurately measured using a self-stabilized recording technique. The measured phase shift as a function of the applied electric field allows computing the Debye screening lenght and the effectively applied field coefficient of an undoped Bi 12TiO 20 crystal. The result is in good agreement with the already available information about this sample. © 2008 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The lack of a systematic approach in Australia to recording and preserving legal history was highlighted in the article by Catherine Hutchins in the August 2002 issue of the Australian Bar Review. This article describes the modest, albeit continuing, efforts on the part of the Supreme Court Library to meet this need in the State of Queensland. The efforts began in 1983 and have recently escalated with a series of exhibitions, talks, displays, interviews and preservations of documents (from online publication).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We aimed to investigate the feasibility of an experimental system for simultaneous transcranial DC stimulation(tDCS) and EEG recording in human epilepsy. We report tolerability of this system in a cross-over controlled trial with 15 healthy subjects and preliminary effects of its use, testing repeated tDCS sessions, in two patients with drug-refractory Continuous Spike-Wave Discharges During Slow Sleep (CSWS). Our system combining continuous recording of the EEG with tDCS allows detailed evaluation of the interictal activity during the entire process. Stimulation with 1 mA was well‐tolerated in both healthy volunteers and patients with refractory epilepsy. The large reduction in interictal epileptiform EEG discharges in the two subjects with epilepsy supports further investigation of tDCS using this combined method of stimulation and monitoring in epilepsy. Continuous monitoring of epileptic activity throughout tDCS improves safety and allows detailed evaluation of epileptic activity changes induced by tDCS in patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magdeburg, Univ., Fak. für Naturwiss., Diss., 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Otto-von-Guericke-Universität Magdeburg, Fakultät für Naturwissenschaften, Univ., Dissertation, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper continues a discussion of approaches and methodologies we have used in our studies of feeding in haematophagous insects. Described are techniques for directly monitoring behaviour: electrical recording of feeding behaviour via resistance changes in the food canal, optical methods for monitoring mouthpart activity, and a computer technique for behavioural event recording. Also described is the use of "flow charts" or "decision diagrams" to model interrelated sequences of behaviours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insight into the function of sleep may be gained by studying animals in the ecological context in which sleep evolved. Until recently, technological constraints prevented electroencephalogram (EEG) studies of animals sleeping in the wild. However, the recent development of a small recorder (Neurologger 2) that animals can carry on their head permitted the first recordings of sleep in nature. To facilitate sleep studies in the field and to improve the welfare of experimental animals, herein, we test the feasibility of using minimally invasive surface and subcutaneous electrodes to record the EEG in barn owls. The EEG and behaviour of four adult owls in captivity and of four chicks in a nest box in the field were recorded. We scored a 24-h period for each adult bird for wakefulness, slow-wave sleep (SWS), and rapid-eye movement (REM) sleep using 4 s epochs. Although the quality and stability of the EEG signals recorded via subcutaneous electrodes were higher when compared to surface electrodes, the owls' state was readily identifiable using either electrode type. On average, the four adult owls spent 13.28 h awake, 9.64 h in SWS, and 1.05 h in REM sleep. We demonstrate that minimally invasive methods can be used to measure EEG-defined wakefulness, SWS, and REM sleep in owls and probably other animals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Anti Bullying Procedures for Primary and Post Primary Schools - Appendix 3 Template for recording bullying behaviour. Provided by the Department of Education and Skills, Ireland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ambulatory blood pressure (BP) was recorded in hypertensive patients whose physicians had been asked to reduce diastolic pressure measured in the office to 90 mm Hg or less. 34 hypertensive patients with a diastolic pressure measured by their physician of 95 mm Hg or more despite antihypertensive therapy had their treatment changed with the aim of achieving this pre-set goal within 3 months. At the beginning and the end of the study, ambulatory BP was monitored during the daytime with a portable non-invasive recorder. The results of the ambulatory recordings were not made available to the physicians until completion of the study. In half the patients the ambulatory diastolic pressure was already 90 mm Hg or less at the start. In these patients, treatment adjustment did not further decrease ambulatory BP. In contrast, patients who initially had an ambulatory diastolic pressure above 90 mm Hg had a significantly decreased ambulatory BP at the end of the study. Intensifying the therapy of hypertensive patients who have a normal ambulatory BP may result in overtreatment without any real gain in BP control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mammalian circadian timing system consists of a master pacemaker in the suprachiasmatic nucleus (SCN) in the hypothalamus, which is thought to set the phase of slave oscillators in virtually all body cells. However, due to the lack of appropriate in vivo recording technologies, it has been difficult to study how the SCN synchronizes oscillators in peripheral tissues. Here we describe the real-time recording of bioluminescence emitted by hepatocytes expressing circadian luciferase reporter genes in freely moving mice. The technology employs a device dubbed RT-Biolumicorder, which consists of a cylindrical cage with reflecting conical walls that channel photons toward a photomultiplier tube. The monitoring of circadian liver gene expression revealed that hepatocyte oscillators of SCN-lesioned mice synchronized more rapidly to feeding cycles than hepatocyte clocks of intact mice. Hence, the SCN uses signaling pathways that counteract those of feeding rhythms when their phase is in conflict with its own phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article outlines a transaction cost theory of title insurance andanalyses the role it plays in countries with recording and registrationof land titles. Title insurance indemnifies real estate right holdersfor losses caused by pre-existing title defects that are unknown whenthe policy is issued. It emerged to complement the errors and omissions insurance of professionals examining title quality. Poor organizationof public records led title insurers in the USA to integrate titleexamination and settlement services. Their residual claimant statusmotivates insurers to screen, cure and avoid title defects. Firmsintroducing title insurance abroad produce little information on titlequality, however. Their policies are instead issued on a casualty basis,complementing and enforcing the professional liability of conveyancers.Future development in markets with land registration is uncertainbecause of adverse selection, competitive reactions from establishedconveyancers and the ability of larger banks to self-insure title risks.