983 resultados para high viscosity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ionic liquids based on 1-alkyl-3-methylimidazolium cations and the hydrogen sulfate (or bisulfate) anion, HSO4-, are much more viscous than ionic liquids with alkyl sulfates, RSO4-. The structural origin of the high viscosity of HSO4- ionic liquids is unraveled from detailed comparison of the anion Raman bands in 1-ethyl-3-methylimidazolium hydrogen sulfate and 1-butyl-3-methylimidazolium hydrogen sulfate with available data for simple HSO(4)(-) salts in crystalline phase, molten phase, and aqueous solution. Two Raman bands at 1046 and 1010 cm(-1) have been assigned as symmetric stretching modes nu(s)(S = O) of HSO4-, the latter being characteristic of chains of hydrogen-bonded anions. The intensity of this component increases in the supercooled liquid phase. For comparison purposes, Raman spectra of 1-ethyl-3-methylimidazolium ethyl sulfate and 1-butyl-3-methylimidazolium methyl sulfate have been also obtained. There is no indication of difference in the strength of hydrogen bond interactions of imidazolium cations with HSO4- or RSO4- anions. Raman spectra at high pressures, up to 2.6 GPa, are also discussed. Raman spectroscopy provides evidence that hydrogen-bonded anions resulting in anion-anion interaction is the reason for the high viscosity of imidazolium ionic liquids with HSO4-. If the ionic liquid is exposed to moisture, these structures are disrupted upon absorption of water from the atmosphere.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Postmortem minimal invasive angiography has already been implemented to support virtual autopsy examinations. An experimental approach in a porcine model to overcome an initially described artificial tissue edema artifact by using a poly ethylene glycol (PEG) containing contrast agent solution showed promising results. The present publication describes the first application of PEG in a whole corpse angiographic CT examination. A minimal invasive postmortem CT angiography was performed in a human corpse utilizing the high viscosity contrast agent solution containing 65% of PEG. Injection was carried out via the femoral artery into the aortic root in simulated cardiac output conditions. Subsequent CT scanning delivered the 3D volume data of the whole corpse. Visualization of the human arterial anatomy was excellent and the contrast agent distribution was generally limited to the arterial system as intended. As exceptions an enhancement of the brain, the left ventricular myocardium and the renal cortex became obvious. This most likely represented the stage of centralization of the blood circulation at the time of death with dilatation of the precapillary arterioles within these tissues. Especially for the brain this resulted in a distinctively improved visualization of the intracerebral structures by CT. However, the general tissue edema artifact of postmortem minimal invasive angiography examinations could be distinctively reduced.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tris(2-ethylhexyl) trimellitate (TOTM) was recently suggested as a reference fluid for industrial use associated with high viscosity at elevated temperature and pressure. Viscosity and density data have already been published on one sample covering the temperature range (303-373) K and at pressures up to about 65 MPa. The viscosity covered a range from about (9 to 460) mPa s. In the present article we study several other characteristics of TOTM that must be available if it were to be adopted as a standard. First, we present values for the viscosity and density obtained with a different sample of TOTM to examine the important feature of consistency among different samples. Vibrating-wire viscosity measurements were performed at pressures from (5 to 100) MPa, along 6 isotherms between (303 and 373) K. Density measurements were carried out from (293 to 373) K up to 68 MPa, along 4 isotherms, using an Anton Paar DMA HP vibrating U-tube densimeter. Secondly, we report a study of the effect of water contamination on the viscosity of TOTM, performed using an Ubbelhode viscometer under atmospheric pressure. Finally, in order to support the use of TOTM as a reference liquid for the calibration of capillary viscometers, values of its surface tension, obtained by the pendant drop method, are provided. (C) 2016 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This paper will develop and illustrate a concept of institutional viscosity to balance the more agentive concept of motility with a theoretical account of structural conditions. The argument articulates with two bodies of work: Archer’s (2007, 2012) broad social theory of reflexivity as negotiating agency and social structures; and Urry’s (2007) sociology of mobility and mobility systems. It then illustrates the concept of viscosity as a variable (low to high viscosity) through two empirical studies conducted in the sociology of education that help demonstrate how degrees of viscosity interact with degrees of motility, and how this interaction can impact on motility over time. The first study explored how Australian Defence Force families cope with their children’s disrupted education given frequent forced relocations. The other study explored how middle class professionals relate to career and educational opportunities in rural and remote Queensland. These two life conditions have produced very different institutional practices to make relocations thinkable and doable, by variously constraining or enabling mobility. In turn, the degrees of viscosity mobile individuals meet with over time can erode or elevate their motility.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We perform two and three dimensional numerical simulations of plume formation in density and viscosity stratified fluid systems. We show that the ambient to plume fluid viscosity ratio strongly affects the near wall plume structures (line or sheet plumes) such as plume spacing and shape of plumes. We observe that where mushroom-like plumes are observed for lower viscosity ratios, taller plumes with bulbous heads form for high viscosity ratios. Plume structure and spacing are in good agreement with experimental results. By studying the geometry of the line plumes and the flow in the circulation cells, we discuss the mechanisms of their formation and the dynamics of merging. We show that an increase in the viscosity ratio decreases the total length of line plumes in the planform which indicates a decreased mixing at higher viscosity ratios. (C) 2015 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Vertebroplasty is a minimally invasive surgical procedure, which requires efficacious percutaneous cement delivery via a cannulated needle to restore the strength and stiffness in osteoporotic vertebral bodies. Cement viscosity is understood to influence the injectability, cohesion and cement retention within the vertebral body. Altering the liquid to powder ratio modifies the viscosity of bone cement; however, the cement viscosity-response association between cement fill and augmentation of strength and stiffness is unknown. The aim of this study was to determine the relationship between viscosity, cement fill and the potential augmentation of strength and stiffness in an open pore foam structure that was representative of osteoporotic cancellous bone using an in vitro prophylactic vertebroplasty model. The results showed a strong linear correlation between compressive strength and stiffness augmentation with percentage cement fill, the extent of which was strongly dependent on the cement viscosity. Significant forces were required to ensure maximum delivery of the high viscosity cement using a proprietary screw-driven cement delivery technology. These forces could potentially exceed the normal human physical limit. Similar trends were observed when comparing the results from this study and previously reported cadaveric and animal based in vitro models.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Impeller speed is one of the most crucial process variables that affect the properties of the granules produced in a high-shear granulator. Several reports can be found in literature that discuss the influence of impeller speed on the granules size. For instance some researchers like Knight report an increase of granule size with impeller speed [1] and [2], while others (Scheaefer et al. and Ramaker et al.) observed a decrease of granules size with increasing impeller speed [3] and [4]. However there is limited work reported in literature on the effect of the impeller speed on the mechanical properties of granules. Mechanical properties are important as they affect the performance of the granules on the other downstream process such as transportation and handling. The work reported here serves to address the missing in knowledge gap regarding the influence of impeller speed on mechanical properties granules. How the granulation system responds to the changes in the impeller speeds depends on binder that is used in the process. For this reason the two extreme cases, of a low viscosity binder system and high viscosity binder system are considered in this research. For low viscosity binder system it was observed that the granule size decreased with increasing impeller speed whilst for the high viscosity binder system the opposite was observed by Knight [1]. The granule strength, the Young's modulus and yield strength of the high viscosity granules increased with increasing impeller speed where as the opposite trends were observed for the low viscosity binder granules.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Being a new generation of green solvents and high-tech reaction media of the future, ionic liquids have increasingly attracted much attention. Of particular interest in this context are room temperature ionic liquids (in short as ILs in this paper). Due to the relatively high viscosity, ILs is expected to be used in the form of solvent diluted mixture with reduced viscosity in industrial application, where predicting the viscosity of IL mixture has been an important research issue. Different IL mixture and many modelling approaches have been investigated. The objective of this study is to provide an alternative model approach using soft computing technique, i.e., artificial neural network (ANN) model, to predict the compositional viscosity of binary mixtures of ILs [C n-mim][NTf 2] with n=4, 6, 8, 10 in methanol and ethanol over the entire range of molar fraction at a broad range of temperatures from T=293.0-328.0K. The results show that the proposed ANN model provides alternative way to predict compositional viscosity successfully with highly improved accuracy and also show its potential to be extensively utilized to predict compositional viscosity taking account of IL alkyl chain length, as well as temperature and compositions simultaneously, i.e., more complex intermolecular interactions between components in which it would be hard or impossible to establish the analytical model. This illustrates the potential application of ANN in the case that the physical and thermodynamic properties are highly non-linear or too complex. © 2012 Copyright the authors.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Este trabalho tem como objectivo a medição da solubilidade de gases em líquidos a altas pressões. Para a realização experimental foi usada uma célula de altas pressões de volume variável e um método de observação directa para a detecção das transições de fase. As condições usadas neste trabalho experimental foram temperaturas entre 276.00 e 373.15 K e pressões ate 100 MPa. Numa primeira fase foram efectuadas medições de solubilidade de metano em anilina pura e para uma solução aquosa de composição mássica igual a 5% em anilina. A anilina é fundamentalmente usada em processos como a produção de borracha, de poliuretanos, pigmentos e tintas, fármacos, herbicidas e fungicidas. É usualmente produzida através de processos de redução do nitrobenzeno por reacção com o HCl. De facto, esta síntese é um processo químico complexo onde um grande número de processos compete entre si. Alterações nas condições do processo com a possível formação de produtos intermediários podem afectar a eficiência do processo. Para a sua melhoria foi sugerido que o hidrogénio usado fosse simultaneamente produzido e gasto no reactor principal. Neste caso e para a produção do mesmo, era necessário adicionar metano e água ao reactor. Tendo por base a ideia de que as reacções onde o hidrogénio é reagente e produto ocorrem em simultâneo, torna-se clara a importância do estudo da solubilidade do metano em anilina pura e em soluções aquosas desta. Numa segunda fase foi estudada a solubilidade do dióxido de carbono em soluções aquosas de tri-iso-butil(metil)fosfónio tosilato, com composições molares são de 4, 8 e 12% em líquido iónico. Este pertencente à família dos fosfónios. Possui uma viscosidade e densidade elevadas, é térmica e quimicamente estável e ainda possui uma elevada polaridade. Apresenta uma miscibilidade completa em água e nos solventes mais usuais, como o diclorometano e tolueno, não sendo no entanto míscivel em hexano. O tri-isobutil( metil)fosfónium tosilato é usado como solvente nos processos de hidroformilação de olefinas e ainda em processos de captura e conversão de dióxido de carbono. Neste trabalho experimental, a temperatura e a pressão foram inicialmente aumentadas até o sistema atingir o equilíbrio. A pressão é diminuída lentamente até se verificar o aparecimento/desaparecimento da última bolha de gás. A pressão à qual a última bolha de gás desaparece representa a pressão de equilíbrio para aquela temperatura. Este procedimento foi efectuado para vários sistemas e várias temperaturas.