972 resultados para hearing protector


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to determine the influence of hearing protection devices (HPDs) on the understanding of speech in young adults with normal hearing, both in a silent situation and in the presence of ambient noise. The experimental research was carried out with the following variables: five different conditions of HPD use (without protectors, with two earplugs and with two earmuffs); a type of noise (pink noise); 4 test levels (60, 70, 80 and 90 dB[A]); 6 signal/noise ratios (without noise, + 5, + 10, zero, - 5 and - 10 dB); 5 repetitions for each case, totalling 600 tests with 10 monosyllables in each one. The variable measure was the percentage of correctly heard words (monosyllabic) in the test. The results revealed that, at the lowest levels (60 and 70 dB), the protectors reduced the intelligibility of speech (compared to the tests without protectors) while, in the presence of ambient noise levels of 80 and 90 dB and unfavourable signal/noise ratios (0, -5 and -10 dB), the HPDs improved the intelligibility. A comparison of the effectiveness of earplugs versus earmuffs showed that the former offer greater efficiency in respect to the recognition of speech, providing a 30% improvement over situations in which no protection is used. As might be expected, this study confirmed that the protectors' influence on speech intelligibility is related directly to the spectral curve of the protector's attenuation. (C) 2003 Elsevier B.V. Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Pop-rock musicians are at risk of developing hearing loss and other symptoms related to amplified music. Aim: The aim of the present study was to assess the satisfaction provided by the use of hearing protection in pop-rock musicians. Study design: Contemporary cohort study. Materials and Methods: A study of 23 male pop-rock musicians, aged between 25 to 45 years. After audiological evaluation (pure tone audiometry, middle ear analysis, TEOAE and DPOAE) hearing protective devices were provided to be used for three months. After that musicians answered a satisfaction assessment questionnaire. Results: The prevalence of hearing loss was of 21.7%. The most common complaints about the hearing protectors were: autophonia, pressure in the ears, interference in high frequencies perception and full time use of the hearing protector during concerts. There was a positive correlation between a reduction in tinnitus after the use of the HPD with the following complaints: tinnitus after beginning the career (p=0.044), discomfort with the sound intensity in the work place (p=0.009) and intolerance to loud sound (p=0.029). Conclusions: There was a high prevalence of hearing loss and a positive tendency towards the use of the ear protector device among the sample population.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This thesis is concerned with the optimising of hearing protector selection. A computer model was used to estimate the reduction in noise exposure and risk of occupational deafness provided by the wearing of hearing protectors in industrial noise spectra. The model was used to show that low attenuation hearing protectors con provide greater protection than high attenuation protectors if the high attenuation protectors ore not worn for the total duration of noise exposure; or not used by a small proportion of the population. The model was also used to show that high attenuation protectors will not necessarily provide significantly greater reduction in risk than low attenuation protectors if the population has been exposed to the noise for many years prior to the provision of hearing protectors. The effects of earplugs and earmuffs on the localisation of sounds were studied to determine whether high attenuation earmuffs are likely to have greater potential than the lower attenuation earplugs for affecting personal safety. Laboratory studies and experiments at a foundry with normal-hearing office employees and noise-exposed foundrymen who had some experience of wearing hearing protectors showed that although earplugs reduced the ability of the wearer to determine the direction of warning sounds, earmuffs produced more total angular error and more confusions between left and right. !t is concluded from the research findings that the key to the selection of hearing protectors is to be found in the provision of hearing protectors that can be worn for a very high percentage of the exposure time by a high percentage of the exposed population with the minimum effect on the personal safety of the wearers - the attenuation provided by the protection should be adequate but not a maximum value.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El presente estudio se realizó con el fin de verificar los niveles de atenuación de dos tipos de protectores auditivos tipo copa, bajo condiciones reales de operación en una empresa del sector hidrocarburos en Colombia. Esta verificación se llevó a cabo determinando las diferencias existentes entre los niveles de atenuación establecidos por el fabricante (NRR Teórico), los niveles de atenuación ajustados de acuerdo a la metodología propuesta por NIOSH (NRR Ajustado) y los niveles de atenuación obtenidos experimentalmente (NRR Experimental). El estudio se desarrolló sobre la evaluación de los niveles equivalentes de presión sonora, mediante dosimetrías de doble canal, valorando los niveles de ruido al interior y al exterior del pabellón auditivo de forma simultánea. Los valores obtenidos en las mediciones se ajustaron a los criterios establecidos en la norma ISO 11904 parte 1 considerando la estimación de niveles de inmisión sonora mediante técnica MIRE (Microphone In a Real Ear) corregidos a condiciones de campo libre. Los resultados obtenidos permitieron establecer diferencias significativas entre los niveles de atenuación teóricos, ajustados y experimentales, aspecto que brinda oportunidades de mejora cuando se trata de seleccionar y mantener elementos de protección personal auditiva como estrategia preventiva primaria en el propósito de la disminución de la probabilidad de ocurrencia de hipoacusia neurosensorial inducida por ruido en el lugar de trabajo.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

El propósito de este estudio es determinar la relación entre la exposición ocupacional y los niveles de audición en trabajadores urbanos en espacio abierto (aseo urbano en general). Se realizó un estudio de corte transversal con 491 personas que incluyen hombres y mujeres, cuyo ambiente laboral es el espacio abierto de la ciudad. Los datos se obtuvieron durante los exámenes médicos periódicos realizados en el año 2014 a los empleados de una empresa cuya actividad económica es el aseo urbano, que incluye recolección de basuras, cuidado forestal y de prados de uso común, y limpieza del borde de los andenes. Se realizó estadística descriptiva para las características demográficas y razón de disparidad u Odds Ratio (OR) para buscar la relación de antecedentes y hábitos personales con el riesgo de desarrollar pérdida auditiva. De las 491 personas expuestas a niveles altos de ruido ocupacional, 62% presentó pérdida auditiva, de los cuales la mayoría se desempeña como guadañadores y cortadores de césped, y son personas que llevan trabajando entre 1-5 años en la empresa. Se encontró un aumento estadísticamente significativo entre la baja escolaridad y el riesgo de sufrir hipoacusia (p=0.0001) y un efecto protector del uso de motocicleta y audífonos. La enfermedad vascular periférica, la práctica de tejo y la diabetes mostraron una fuerte tendencia a aumentar el riesgo. La pérdida auditiva encontrada en este grupo no se puede relacionar directamente con la exposición ocupacional a ruido, a pesar de ser trabajos que se llevan a cabo en el espacio urbano. Sin embargo, la baja escolaridad favorece la lesión auditiva y puede verse acelerada por enfermedades de alta prevalencia como diabetes y practicas recreacionales locales.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La Directiva 2003/10/CE del Parlamento Europeo y del Consejo, del 6 de febrero de 2003, específica con arreglo al apartado 1 del artículo 16 de la Directiva 89/391/CEE las disposiciones mínimas de seguridad y de salud relativas a la exposición de los trabajadores a los riesgos derivados de los agentes físicos (ruido). En la industria musical, y en concreto en los músicos de orquesta, una exposición de más de ocho horas al día a un nivel de presión sonora de 80dB(A) o más es algo muy común. Esta situación puede causar a los trabajadores daños auditivos como la hiperacusia, hipoacusia, tinitus o ruptura de la membrana basilar entre otros. Esto significa que deben tomarse medidas para implementar las regulaciones de la forma más razonable posible para que la interpretación del músico, la dinámica y el concepto musical que se quiere transmitir al público se vea lo menos afectada posible. Para reducir la carga auditiva de los músicos de orquesta frente a fuertes impactos sonoros provenientes de los instrumentos vecinos, se está investigando sobre el uso de unos paneles acústicos que colocados en puntos estratégicos de la orquesta pueden llegar a reducir el impacto sonoro sobre el oído hasta 20dB. Los instrumentos de viento metal y de percusión son los responsables de la mayor emisión de presión sonora. Para proteger el oído de los músicos frente a estos impactos, se colocan los paneles en forma de barrera entre dichos instrumentos y los músicos colocados frente a ellos. De esta forma se protege el oído de los músicos más afectados. Para ver el efecto práctico que producen estos paneles en un conjunto orquestal, se realizan varias grabaciones en los ensayos y conciertos de varias orquestas. Los micrófonos se sitúan a la altura del oído y a una distancia de no más de 10cm de la oreja de varios de los músicos más afectados y de los músicos responsables de la fuerte emisión sonora. De este modo se puede hacer una comparación de los niveles de presión sonora que percibe cada músico y evaluar las diferencias de nivel existentes entre ambos. Así mismo se utilizan configuraciones variables de los paneles para comparar las diferencias de presión sonora que existen entre las distintas posibilidades de colocarlos y decidir así sobre la mejor ubicación y configuración de los mismos. A continuación, una vez obtenidos las muestras de audio y los diferentes archivos de datos medidos con un analizador de audio en distintas posiciones de la orquesta, todo ello se calibra y analiza utilizando un programa desarrollado en Matlab, para evaluar el efecto de los paneles sobre la percepción auditiva de los músicos, haciendo especial hincapié en el análisis de las diferencias de nivel de presión sonora (SPL). Mediante el cálculo de la envolvente de las diferencias de nivel, se evalúa de un modo estadístico el efecto de atenuación de los paneles acústicos en los músicos de orquesta. El método está basado en la probabilidad estadística de varias muestras musicales ya que al tratarse de música tocada en directo, la dinámica y la sincronización entre los músicos varía según el momento en que se toque. Estos factores junto con el hecho de que la partitura de cada músico es diferente dificulta la comparación entre dos señales grabadas en diferentes puntos de la orquesta. Se necesita por lo tanto de varias muestras musicales para evaluar el efecto de atenuación de los paneles en las distintas configuraciones mencionadas anteriormente. El estudio completo del efecto de los paneles como entorno que influye en los músicos de orquesta cuando están sobre el escenario, tiene como objetivo la mejora de sus condiciones de trabajo. Abstract For several years, the European Union has been adopting many laws and regulations to protect and give more security to people who are exposed to some risk in their job. Being exposed to a loud sound pressure level during many hours in the job runs the risk of hearing damage. Particularly in the field of music, the ear is the most important working tool. Not taking care of the ear can cause some damage such as hearing loss, tinnitus, hyperacusis, diplacusis, etc. This could have an impact on the efficiency and satisfaction of the musicians when they are playing, which could also cause stress problems. Orchestra musicians, as many other workers in this sector, are usually exposed to a sound level of 80dB(A) or more during more than eight hours per day. It means that they must satisfy the law and their legal obligations to avoid health problems proceeding from their job. Putting into practice the new regulations is a challenge for orchestras. They must make sure that the repertoire, with its dynamic, balance and feeling, is not affected by the reduction of sound levels imposed by the law. This study tries to investigate the benefits and disadvantages of using shields as a hearing protector during rehearsals and orchestral concerts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to describe the outcome of neonatal hearing screening (NHS) and audiological diagnosis in neonates in the NICU. The sample was divided into Group I: neonates who underwent NHS in one step and Group II: neonates who underwent a test and retest NHS. NHS procedure was automated auditory brainstem response. NHS was performed in 82.1% of surviving neonates. For GI, referral rate was 18.6% and false-positive was 62.2% (normal hearing in the diagnostic stage). In GII, with retest, referral rate dropped to 4.1% and false-positive to 12.5%. Sensorineural hearing loss was found in 13.2% of infants and conductive in 26.4% of cases. There was one case of auditory neuropathy spectrum (1.9%). Dropout rate in whole process was 21.7% for GI and 24.03% for GII. We concluded that it was not possible to perform universal NHS in the studied sample or, in many cases, to apply it within the first month of life. Retest reduced failure and false-positive rate and did not increase evasion, indicating that it is a recommendable step in NHS programs in the NICU. The incidence of hearing loss was 2.9%, considering sensorineural hearing loss (0.91%), conductive (1.83%) and auditory neuropathy spectrum (0.19%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article analyzed whether the practices of hearing health care were consistent with the principles of universality, comprehensiveness and equity from the standpoint of professionals. It involved qualitative research conducted at a Medium Complexity Hearing Health Care Center. A social worker, three speech therapists, a physician and a psychologist constituted the study subjects. Interviews were conducted as well as observation registered in a field diary. The thematic analysis technique was used in the analysis of the material. The analysis of interviews resulted in the construction of the following themes: Universality and access to hearing health, Comprehensive Hearing Health Care and Hearing Health and Equity. The study identified issues that interfere with the quality of service and run counter to the principles of Brazilian Unified Health System. The conclusion reached was that a relatively simple investment in training and professional qualification can bring about significant changes in order to promote a more universal, comprehensive and equitable health service.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electroacoustic stimulation is an excellent option for people with residual hearing in the low frequencies, who obtain insufficient benefit with hearing aids. To be effective, the subject's residual hearing should be preserved during cochlear implant surgery. To evaluate the hearing preservation in patients that underwent implant placement and to compare the results in accordance with the approach to the inner ear. 19 subjects underwent a soft surgical technique, and the electrode MED-EL FLEX™ EAS, designed to be atraumatic, was used. We evaluated pre- and postoperative tonal audiometric tests with an average of 18.4 months after implantation, to measure the rate of hearing preservation. 17 patients had total or partial preservation of residual hearing; 5 had total hearing preservation and two individuals had no preservation of hearing. The insertion of the electrode occurred through a cochleostomy in 3 patients, and in 2 of these there was no hearing preservation; the other 16 patients experienced electrode insertion through a round window approach. All patients benefited from the cochlear implant, even those who are only using electrical stimulation. The hearing preservation occurred in 89.4% of cases. There was no significant difference between the forms of inner ear approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: It is well known the association between gastroesophageal reflux disease and asthma. The hyperreactivity of the airways is a characteristic of an asthmatic. Many studies associate the increase of the airways reactivity with gastroesophageal reflux disease. AIM: In this study we have evaluated the effect of the intraluminal exposition to gastric juice of trachea on the reactivity to methacholine from rats submitted to a pulmonary allergic inflammation. METHODS: Group of rats were sensitized and challenged with ovalbumin. After 24 hours the animals were sacrificed, and their tracheae were removed to be cultured with gastric juice. The gastric juice was obtained from a donor rat. Subsequently the segments were placed into plastic plates with RPMI-1640 for incubation, under suitable atmosphere and time. After the period of incubation the segments were put into chambers for the analysis of the contractile response to methacholine. RESULTS: We observed reduction in the contractile response of trachea cultured with gastric juice from allergic rats. This result was confirmed by the pharmacological treatments with compound 48/80 and dissodium cromoglicate (mast cells blockade), L-NAME (nitric oxide inhibitor, NO), capsaicin (neuropeptides depletion) and indomethacin (ciclooxigenase inhibitor). CONCLUSIONS: Our results highlight to the existence of a complex interaction between pulmonary allergy and gastric juice in the airways. The involvement of the non-adrenergic non-cholinergic system, NO, prostanoids and mast cells are directly related to this interaction. We suggest that the reduced contractile response observed in vitro may represent a protector mechanism of the airways. Despite its presence in the human body it can not be observed due to the predominant effects of excitatory the non-adrenergic non-cholinergic system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spectral peak resolution was investigated in normal hearing (NH), hearing impaired (HI), and cochlear implant (CI) listeners. The task involved discriminating between two rippled noise stimuli in which the frequency positions of the log-spaced peaks and valleys were interchanged. The ripple spacing was varied adaptively from 0.13 to 11.31 ripples/octave, and the minimum ripple spacing at which a reversal in peak and trough positions could be detected was determined as the spectral peak resolution threshold for each listener. Spectral peak resolution was best, on average, in NH listeners, poorest in CI listeners, and intermediate for HI listeners. There was a significant relationship between spectral peak resolution and both vowel and consonant recognition in quiet across the three listener groups. The results indicate that the degree of spectral peak resolution required for accurate vowel and consonant recognition in quiet backgrounds is around 4 ripples/octave, and that spectral peak resolution poorer than around 1–2 ripples/octave may result in highly degraded speech recognition. These results suggest that efforts to improve spectral peak resolution for HI and CI users may lead to improved speech recognition

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to explore the potential advantages, both theoretical and applied, of preserving low-frequency acoustic hearing in cochlear implant patients. Several hypotheses are presented that predict that residual low-frequency acoustic hearing along with electric stimulation for high frequencies will provide an advantage over traditional long-electrode cochlear implants for the recognition of speech in competing backgrounds. A simulation experiment in normal-hearing subjects demonstrated a clear advantage for preserving low-frequency residual acoustic hearing for speech recognition in a background of other talkers, but not in steady noise. Three subjects with an implanted "short-electrode" cochlear implant and preserved low-frequency acoustic hearing were also tested on speech recognition in the same competing backgrounds and compared to a larger group of traditional cochlear implant users. Each of the three short-electrode subjects performed better than any of the traditional long-electrode implant subjects for speech recognition in a background of other talkers, but not in steady noise, in general agreement with the simulation studies. When compared to a subgroup of traditional implant users matched according to speech recognition ability in quiet, the short-electrode patients showed a 9-dB advantage in the multitalker background. These experiments provide strong preliminary support for retaining residual low-frequency acoustic hearing in cochlear implant patients. The results are consistent with the idea that better perception of voice pitch, which can aid in separating voices in a background of other talkers, was responsible for this advantage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The differences in spectral shape resolution abilities among cochlear implant ~CI! listeners, and between CI and normal-hearing ~NH! listeners, when listening with the same number of channels ~12!, was investigated. In addition, the effect of the number of channels on spectral shape resolution was examined. The stimuli were rippled noise signals with various ripple frequency-spacings. An adaptive 4IFC procedure was used to determine the threshold for resolvable ripple spacing, which was the spacing at which an interchange in peak and valley positions could be discriminated. The results showed poorer spectral shape resolution in CI compared to NH listeners ~average thresholds of approximately 3000 and 400 Hz, respectively!, and wide variability among CI listeners ~range of approximately 800 to 8000 Hz!. There was a significant relationship between spectral shape resolution and vowel recognition. The spectral shape resolution thresholds of NH listeners increased as the number of channels increased from 1 to 16, while the CI listeners showed a performance plateau at 4–6 channels, which is consistent with previous results using speech recognition measures. These results indicate that this test may provide a measure of CI performance which is time efficient and non-linguistic, and therefore, if verified, may provide a useful contribution to the prediction of speech perception in adults and children who use CIs.