999 resultados para fluxo de fluido
Resumo:
Analisamos alguns modelos de fluxo de fluido utilizando o software gráfico F(C): Funções Complexas. Descrevemos as equações que expressam o potencial complexo, bem como a velocidade complexa para cada modelo. Os modelos estudados são fluxo uniforme, com fonte, com sumidouro, composto, circular e com obstáculo. Apresentamos o conceito de Domínio de Cores e o mecanismo de leitura dos gráficos. Cada modelo é apresentado de forma exemplificada, incluindo representações geométricas das curvas de fluxo e equipotenciais, bem como os gráficos do potencial complexo e velocidade complexa.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The determination of the rheology of drilling fluids is of fundamental importance to select the best composition and the best treatment to be applied in these fluids. This work presents a study of the rheological behavior of some addictives used as viscosifiers in water-based drilling fluids. The evaluated addictives were: Carboxymethylcellulose (CMC), Xanthan gum (GX), and Bentonite. The main objective was to rheologically characterize suspensions composed by these addictives, by applying mathematical models for fluid flow behavior, in order to determine the best flow equation to represent the system, as well as the model parameters. The mathematical models applied in this research were: the Bingham Model, the Ostwald de Wale Model, and the Herschel-Bulkley Model. A previous study of hydration time for each used addictive was accomplished seeking to evaluate the effect of polymer and clay hydration on rheological behavior of the fluid. The rheological characterization was made through typical rheology experiments, using a coaxial cylinder viscosimeter, where the flow curves and the thixotropic magnitude of each fluid was obtained. For each used addictive the rheological behavior as a function of temperature was also evaluated as well as fluid stability as a function of the concentration and kind of addictive used. After analyses of results, mixtures of polymer and clay were made seeking to evaluate the rheological modifications provided by the polymer incorporation in the water + bentonite system. The obtained results showed that the Ostwald de Waale model provided the best fit for fluids prepared using CMC and for fluids with Xanthan gum and Bentonite the best fit was given by the Herschel-Bulkley one
Resumo:
The complexity of the Phenomenon of fluid flow in porous way causes a difficulty in its explicit description. Different in the cases where the flow is given through a pipe, where it is possible to measure the length and diameter of the pipe and to determine their ability to flow as a function of pressure, which is a complicated task in porous way. However, we try to approach clearly the equations used to conjecture the behavior of fluid flow in porous way. We made use of the Gambit to create a fractal geometry with the fluent we give the contour´s conditions we would want to analyze the data. The triangular mesh was created; it makes interactions with the discs of different rays, as barriers putted in the geometry. This work presents the results of a simulation with a flow of viscous fluids (oilliquid). The oil flows in a porous way constructed in 2D. The behavior evaluation of the fluid flow inside the porous way was realized with graphics, images and numerical results used for different datas analysis. The study was aimed in relation at the behavior of permeability (k) for different fractal dimensions. Taking into account the preservation of porosity and increasing the fractal distribution of the discs. The results showed that k decreases when we increase the numbers of discs, although the porosity is the same for all generations of the first simulation, in other words, the permeability decreases when we increase the fractality. Well, there are strong turbulence in the flow each time we increase the number of discs and this hinders the passage of the same to the exit. These results permitted to put in evidence how the permeability (k) is affected in a porous way with obstacles distributed in a diversified form. We also note that k decreases when we increase the pressure variation (P) within geometry. So, in front of the results and the absence of bibliographic subsidies about other theories, the work realized here can possibly by considered the unpublished form to explain and reflect on how the permeability is changed when increasing the fractal dimension in a porous way
Resumo:
Nas últimas duas décadas, as cerâmicas avançadas têm sido exaustivamente utilizadas em aplicações na indústria devido às suas propriedades de elevada resistência ao desgaste e dureza. Entretanto, ainda se tem um alto custo agregado ao acabamento da peça. Esse acabamento geralmente é feito pelo processo de retificação, único processo economicamente viável que produz superfícies de elevada qualidade e precisão geométrica. Nesse contexto, as empresas vêm buscando a otimização no processo de retificação como, por exemplo, a redução do fluxo de fluido de corte utilizado, o que também visa atender exigências mundiais de preservação ambiental. Desta forma, este projeto pretendeu explorar a técnica da Mínima Quantidade de Lubrificação (MQL) na retificação cilíndrica externa de mergulho em cerâmicas com rebolos diamantados. Foram utilizados dois métodos de refrigeração: o convencional e o MQL, com três avanços de corte para cada caso. Foram usados um bocal convencional e um bocal para o MQL, tendo este um uniformizador de saída do jato. Foram analisadas como variáveis de saída: a emissão acústica, relação G, aspecto da superfície via microscopia eletrônica de varredura (MEV), rugosidade e circularidade. Assim, embora a refrigeração convencional ainda apresente os melhores resultados em comparação com a refrigeração com MQL, esta última pode atender os requisitos necessários para diversas aplicações, em especial quando utilizadas baixas espessuras equivalentes de corte (h eq). Além disso, a técnica de MQL possui a vantagem de gerar um menor impacto ambiental em comparação com a lubrificação convencional, devido ao uso mínimo de fluido de corte cujo descarte é cada vez mais regulamentado e custoso.
Resumo:
A interferência eletromagnética causada pela linha de energia elétrica afeta negativamente os sinais de instrumentos eletrônicos, especialmente aqueles com baixos níveis de amplitude. Este tipo de interferência é conhecida como interferência de modo comum. Existem muitos métodos e arquiteturas utilizadas para minimizar a influência deste fenômeno de interferência em instrumentos eletrônicos, o mais comum dos quais é a utilização de filtros rejeita banda. Este trabalho apresenta: a análise, desenvolvimento, protótipo e teste de uma nova arquitetura de filtro com característica reconfigurável para instrumentos biomédicos e medição de dados de fluxo em fluido de alta complexidade, com objetivo de reduzir a interferência de modo comum e preservar as componentes do sinal útil na mesma faixa de frequência do ruído, utilizando a técnica de equilíbrio dinâmico de impedância. Além disso, este trabalho pode ser usado em qualquer sistema de medição que também sofra interferência na frequência da linha de alimentação (50/60 Hz, no Brasil e na França, 60 Hz nos Estados Unidos da América). Os blocos de circuitos foram modelados matematicamente e a função de transferência global do circuito fechado foi gerada. Em seguida, o projeto foi descrito e simulado na língua VHDL_AMS e também em um software de simulação eletrônica, usando blocos de componentes discretos, com e sem realimentação. Após análise teórica dos resultados da simulação, um circuito protótipo foi construído e testado usando como entrada um sinal obtido a partir de eletrodos de ECG e Eletrodos Eletroresistivos. Os resultados experimentais do circuito condizem com os da simulação: uma redução de ruído de 98,7% foi obtida em simulações utilizando um sinal sinusoidal, e uma redução de 92% foi realizada utilizando eletrodos de ECG em testes experimentais. Os mesmos testes em eletrodos Eletroresistivos, obtendo o maior valor de 80,3% de redução (durante análise de 3 casos). Em ambos os casos, o sinal útil foi preservado. O método e a sua arquitetura pode ser aplicado para atenuar as interferências que ocorrem na mesma banda de frequência das componentes do sinal útil, preservando ao mesmo tempo estes sinais.
Resumo:
The distribution of diagenetic alterations in Late Cenomanian siliciclastic reservoirs from Potiguar Basin was influenced by the stratigraphic framework and the depositional system. Seismic sections and geophysical logs of two wells drilled in the SW portion of the mentioned basin above register regional stratigraphic surfaces representing maximum floods related to a transgressive event. The sequential analysis of 80 m of drill core (~450 m deep) recognized nine depositional facies with an upwards granodecrescent standard piling that limits cycles with an erosional conglomeratic base (lag) overlain by intercalations of medium to very fine sandstones showing cross bedding (channel, planar and low angled) and horizontal bedding (plane-parallel , wave and flaser). The top of the cycles is marked by the deposition of pelites and the development of paleosoils and lagoons. The correlation of genetically related facies reveals associations of channel fillings, crevasse, and flood plains deposited in a transgressive system. Detailed descriptions of seventy nine thin sections aided by MEV-EBSD/EDS, DRX and stable isotope analyses in sandstones revealed an arcosian composition and complex textural arrays with abundant smectite fringes continuously covering primary components, mechanically infiltrated cuticles and moldic and intragrain pores. K-feldspar epitaxial overgrowth covers microcline and orthoclase grains before any other phase. Abundant pseudomatrix due to the compactation of mud intraclasts concentrate along the stratification planes, locally replaced by macrocristalline calcite and microcrystalline and framboidal pyrite. Kaolinite (booklets and vermicular), microcrystalline smectite, microcrystalline titanium minerals and pyrite replace the primary components. The intergrain porosity prevails over the moldic, intragrain and contraction porosities. The pores are poorly connected due to the presence of intergranular smectite, k-feldspar overgrowth, infiltrated mud and pseudomatrix. The sandstones were subjected to eodiagenetic conditions next to the surface and shallow burial mesodiagenetic conditions. The diagenetic alterations reduced the porosity and the permeability mainly due to the precipitation of smectite fringes, compactation of mud intraclasts onto the pseudomatrix and cementing by poikilotopic calcite characterizing different reservoir petrofacies. These diagenetic products acted as barriers and detours to the flow of fluids thus reducing the quality of the reservoir.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
OBJETIVO: avaliar a sensibilidade dolorosa e os fatores envolvidos na produção de fluido papilar adequado para análise de citologia oncótica, por meio de sistema automatizado de coleta. MÉTODOS: foram selecionadas 50 mulheres assintomáticas, sem antecedente pessoal ou familiar de câncer de mama, fora do ciclo gravídico-puerperal para coleta de fluido papilar por meio de sistema automatizado. Foram registradas e relacionadas com a produção de fluido papilar a idade da paciente, tabagismo, antecedente de cirurgia mamária, paridade, amamentação, estado menopausal e idade da menarca. Todo o material coletado foi fixado em meio apropriado, e encaminhado separadamente para análise de citologia oncótica. A sensibilidade dolorosa do procedimento de coleta foi avaliada por meio da Escala Category-Ratio Scale (CR10) de Borg. RESULTADOS: a idade variou de 22 a 59 anos, média de 41,6±8,6 anos. Das 50 pacientes, 20 (40%) não apresentaram fluido papilar adequado para análise em nenhuma das mamas. Naquelas pacientes que se obteve fluido papilar adequado para análise de citologia oncótica, a paridade esteve inversamente relacionada com a capacidade de obter amostra celular adequada, nível de significância estatística (p=0,035), OR=0,0032 (IC 95%=0,0001-0,1388). Em relação à sensibilidade dolorosa, o exame foi bem tolerado. CONCLUSÕES: o método automatizado de coleta de fluido papilar para análise de citologia oncótica foi bem tolerado pelas mulheres tendo produzido material analisável em 60% dos casos, esteve inversamente relacionado com a paridade.
Resumo:
Water injection is the most widely used method for supplementary recovery in many oil fields due to various reasons, like the fact that water is an effective displacing agent of low viscosity oils, the water injection projects are relatively simple to establish and the water availability at a relatively low cost. For design of water injection projects is necessary to do reservoir studies in order to define the various parameters needed to increase the effectiveness of the method. For this kind of study can be used several mathematical models classified into two general categories: analytical or numerical. The present work aims to do a comparative analysis between the results presented by flow lines simulator and conventional finite differences simulator; both types of simulators are based on numerical methods designed to model light oil reservoirs subjected to water injection. Therefore, it was defined two reservoir models: the first one was a heterogeneous model whose petrophysical properties vary along the reservoir and the other one was created using average petrophysical properties obtained from the first model. Comparisons were done considering that the results of these two models were always in the same operational conditions. Then some rock and fluid parameters have been changed in both models and again the results were compared. From the factorial design, that was done to study the sensitivity analysis of reservoir parameters, a few cases were chosen to study the role of water injection rate and the vertical position of wells perforations in production forecast. It was observed that the results from the two simulators are quite similar in most of the cases; differences were found only in those cases where there was an increase in gas solubility ratio of the model. Thus, it was concluded that in flow simulation of reservoirs analogous of those now studied, mainly when the gas solubility ratio is low, the conventional finite differences simulator may be replaced by flow lines simulator the production forecast is compatible but the computational processing time is lower.
Resumo:
The present study provides a methodology that gives a predictive character the computer simulations based on detailed models of the geometry of a porous medium. We using the software FLUENT to investigate the flow of a viscous Newtonian fluid through a random fractal medium which simplifies a two-dimensional disordered porous medium representing a petroleum reservoir. This fractal model is formed by obstacles of various sizes, whose size distribution function follows a power law where exponent is defined as the fractal dimension of fractionation Dff of the model characterizing the process of fragmentation these obstacles. They are randomly disposed in a rectangular channel. The modeling process incorporates modern concepts, scaling laws, to analyze the influence of heterogeneity found in the fields of the porosity and of the permeability in such a way as to characterize the medium in terms of their fractal properties. This procedure allows numerically analyze the measurements of permeability k and the drag coefficient Cd proposed relationships, like power law, for these properties on various modeling schemes. The purpose of this research is to study the variability provided by these heterogeneities where the velocity field and other details of viscous fluid dynamics are obtained by solving numerically the continuity and Navier-Stokes equations at pore level and observe how the fractal dimension of fractionation of the model can affect their hydrodynamic properties. This study were considered two classes of models, models with constant porosity, MPC, and models with varying porosity, MPV. The results have allowed us to find numerical relationship between the permeability, drag coefficient and the fractal dimension of fractionation of the medium. Based on these numerical results we have proposed scaling relations and algebraic expressions involving the relevant parameters of the phenomenon. In this study analytical equations were determined for Dff depending on the geometrical parameters of the models. We also found a relation between the permeability and the drag coefficient which is inversely proportional to one another. As for the difference in behavior it is most striking in the classes of models MPV. That is, the fact that the porosity vary in these models is an additional factor that plays a significant role in flow analysis. Finally, the results proved satisfactory and consistent, which demonstrates the effectiveness of the referred methodology for all applications analyzed in this study.
Resumo:
Em meados da década de 50 iniciou-se o desenvolvimento da citometria de fluxo, tecnologia que permite verificar características físico-químicas de células ou partículas suspensas em meio fluido. Esta tecnologia utiliza anticorpos monoclonais marcados com fluorocromos como ferramenta de investigação em diversas análises e necessita de controles isotípicos para definição da região negativa (background). Estes controles são constituídos por imunoglobulinas de mesmo isotipo e fluorocromo dos anticorpos testes, sendo o isotiocianato de fluoresceína (FITC) o marcador fluorescente mais utilizado na conjugação de anticorpos. Os controles isotípicos têm como função definir a fluorescência inespecífica (células negativas) e as regiões fluorescentes (células positivas). No presente estudo foi selecionado anticorpo monoclonal murino (AcMm) dirigido contra antígeno eritrocitário canino, produzido no Laboratório de Anticorpos Monoclonais do Hemocentro de Botucatu, o qual reage positivamente com hemácias de cães, mas nunca com leucócitos humanos, tendo, portanto, potencial utilidade como controle negativo em citometria de fluxo. A purificação do AcMm da subclasse IgG1 foi feita por cromatografia de afinidade em Proteína-A Sepharose, e o controle da purificação realizado por eletroforese em géis de ágarose e poliacrilamida (SDS-PAGE). A imunoglobulina purificada foi conjugada ao FITC e filtrado em coluna de Sephadex G-25 para separação das proteínas marcadas e não-marcadas. O AcMm conjugado foi testado contra hemácias de cães, e o êxito da conjugação comprovado por testes de fluorescência, sendo a mediana de positividade de 94,70. Frente a leucócitos humanos a mediana de positividade foi 0,03 contra 0,50 dos reagentes comerciais. Os testes estatísticos não-paramétricos de Wilcoxon e correlação de Spearman comprovaram a eficiência e validam o controle isotípico produzido em comparação aos reagentes comerciais testados.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS