930 resultados para excess sludge


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An integrated anaerobic-aerobic treatment system of sulphate-laden wastewater was proposed here to achieve low sludge production, low energy consumption and effective sulphide control. Before integrating the whole system, the feasibility of autotrophic denitrification utilising dissolved sulphide produced during anaerobic treatment of sulphate rich wastewater was studied here. An upflow anaerobic sludge blanket reactor was operated to treat sulphate-rich synthetic wastewater (TOC = 100 mg/L and sulphate = 500 mg/L) and its effluent with dissolved sulphide and external nitrate solution were fed into an anoxic biofilter. The anaerobic reactor was able to remove 77-85% of TOC at HRT of 3 h and produce 70-90 mg S/L sulphide in dissolved form for the subsequent denitrification. The performance of anoxic reactor was stable, and the anoxic reactor could remove 30 mg N/L nitrate at HRT of 2 h through autotrophic denitrification. Furthermore, sulphur balance for the anoxic filter showed that more than 90% of the removed sulphide was actually oxidised into sulphate, thereby there was no accumulation of sulphur particles in the filter bed. The net sludge productions were approximately 0.15 to 0.18 g VSS/g COD in the anaerobic reactor and 0.22 to 0.31 g VSS/g NO3--N in the anoxic reactor. The findings in this study will be helpful in developing the integrated treatment system to achieve low-cost excess sludge minimisation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This article describes an effective procedure for reducing the water content of excess sludge production from a wastewater treatment plant by increasing its concentration and, as a consequence, minimizing the volume of sludge to be managed. It consists of a pre-dewatering sludge process, which is used as a preliminary step or alternative to the thickening. It is made up of two discontinuous sequential stages: the first is resettling and the second, filtration through a porous medium. The process is strictly physical, without any chemical additives or electromechanical equipment intervening. The experiment was carried out in a pilot-scale system, consisting of a column of sedimentation that incorporates a filter medium. Different sludge heights were tested over the filter to verify the influence of hydrostatic pressure on the various final concentrations of each stage. The results show that the initial sludge concentration may increase by more than 570% by the end of the process with the final volume of sludge being reduced in similar proportions and hydrostatic pressure having a limited effect on this final concentration. Moreover, the value of the hydrostatic pressure at which critical specific cake resistance is reached is established.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

活性污泥法是目前世界上普遍应用的污水生物处理工艺,其在运行过程中产生大量的剩余污泥。由于剩余污泥处理费用巨大及污泥最终处置对环境具有潜在危害问题,污泥的处理和处置已经成为水处理领域关注的焦点。本文利用实验室筛选的溶胞菌群,在好氧消化的同时对污泥进行前处理,促进剩余污泥的破解与溶胞,再通过两相厌氧处理对污泥进行进一步消化,以研究投加溶胞菌对剩余污泥消化的影响。 本研究中溶胞菌污泥减量化技术分为两个部分,第一,污泥在溶胞菌作用下的好氧消化与污泥传统好氧消化的对比研究,利用取自成都三瓦窑污水处理厂剩余污泥,向好氧污泥消化反应器中投加溶胞菌,检测各项污泥指标,并通过同传统好氧污泥消化对比,以研究溶胞菌对污泥好氧消化的影响。第二, 经过溶胞菌处理后好氧消化的剩余污泥进行两相厌氧处理研究。通过建立好氧溶胞联合两相厌氧消化系统的来处理剩余污泥,并与相同条件运行的两相厌氧消化系统做对比,检测运行过程中系统中物质成分变化,研究了其处理能力和运行稳定性,探索了两相厌氧消化系统中的发酵类型差别,验证了好氧溶胞对剩余污泥的破解效果。 研究结果表明:污泥在溶胞菌作用下的好氧消化效果和消化效率均优于传统好氧消化。在溶胞菌群存在的情况下,剩余污泥的TSS和VSS去除率达到40%和53%,远高于传统好氧消化的12%和20%。污泥经过溶胞及好氧消化后,TCOD去除率达到54.4%。经过溶胞菌处理后的剩余污泥再进入两相厌氧处理系统,进入厌氧处理系统的剩余污泥的VSS/TSS比值约为0.62。在两相厌氧处理水力停留时间(HRT)为8d时,溶胞处理污泥厌氧消化后VSS去除率达到55.17%,对照组两相厌氧系统的VSS去除率平均值为18.53%。经过溶胞处理的两相厌氧系统的污泥减量了能力远高于对照组。两相厌氧系统的pH值和碱度说明系统运行较为稳定。产酸相的有机酸中乙酸含量高于丙酸和丁酸,说明发酵末端产物以乙酸为主。在20天的试验周期内,污泥溶胞处理后、两相厌氧系统产甲烷相产气量累积产气量为1.2L,对照组只有375ml。气体中甲烷含量都在55%左右。该研究结果表明,好氧溶胞对污泥有破解能力,溶胞处理对两相厌氧中产酸相水解污泥细胞有明显的促进作用,提高了产酸相的水解酸化能力和效率。该研究对于利用生物溶胞途径提高污泥消化效率具有重要意义。 The actived sludge process has been used more and more extensively, but the procedure will lead to a large quantity of excess sludge. The treatment of Excess activated sludge has becomes a focuses not only for it is a seriously negative effect on environment but also for the costly disposal comes subsequently. The cell lysing bacterium was keeped in our lab to joined in the digestion of the excess activated sludge which was carrying at the same time with pre-processing of sludge to investigated the influence of cell lysing bacterium on excess sludge. There are two part in the method of cell lysing bacterium digesting sludge technology, the first, comparison of excess sludge digestion between anaerobic Cell-lysing Pretreatment and Conventional Aerobic Process. The sludge which was collected from San Wanyao disposal plant in Chengdu was thrown into the aerobic process system with cell-lysing bacterium, then, the indexes were detected to compare the difference between the cell-lysing bacterium in aerobic process and the traditional method to determine the influence of cell-lysing bacterium on aerobic process ; The second, the research on the sludge which was pro-treated with cell-lysing and aerobic digestion in the diphase of anaerobic digestion system. The system of cell-lysing combined with diphase of anaerobic digesting was created to compare to the diphase of anaerobic digested system, the changes of mass constituent was detected to study the ability and steady of disposal. Moreover, the research explored the difference among the types of fermentation. The efficacious of aerobic process was been proved. The result shows that the digesting rate of aerobic process with cell-lysing bacterium was higher than the traditional process. The ratio of sludge is reach to 40%~53%, which was far more effectively than the traditional process rate of 12%~20%. The TCOD of sludge which was treated with cell lysing bacterium and Aerobic Process is reach to 54.4%. Then, the sludge was thrown into the diphase of anaerobic digesting system. VSS/TSS of sludge is 0.62, HRT is 6d, the reduction of VSS is reach to 40.8%. The pH and alkalinity indicate the steady running of the diphase anaerobic digest system. In the acerbity phasing, the content of acetic acid was more than butanoic acid and propanoic acid in organic acid, it is demonstrated that the main composition of final production of fermentation was Acetic Acid. During the 20d of experiment, methylhydride phasing of diphase anaerobic digest system produced 1.2L methylhydride, however, there is only 375ml in CK, the content of methylhydride in all gas phase was around the rate of 55%. The average ratio of VSS was 18.53% in CK diphase anaerobic digest system which was far more unavailable than the mass sludge rate of 55.17%. Results demonstrated that aerobic cell-lysing digested the sludge, the treat of cell-lysing could obviously promoted the hydrolyzeing of sludge cell in the acerbity phasing, which improved the ability and rate of hydrolization and acidification. This study is significant in inhenceing the rate of sludge digestion in the method of cell-lysing bacterium.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La tecnica di ozonolisi viene applicata ai fanghi biologici derivanti da impianti di depurazione acque reflue urbane, e consiste nell'ottenere, grazie all'ozono, una minor massa fangosa da smaltire e una miglior trattabilità del fango residue. In questo elaborato si prendono in esame le sperimentazioni effettuate a Marina di Ravenna e si estraggono le prime conclusioni gestionali, economiche e ambientali sull'applicabilità del metodo a questo tipo di fango.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experimental work was performed to delineate the system of digested sludge particles and associated trace metals and also to measure the interactions of sludge with seawater. Particle-size and particle number distributions were measured with a Coulter Counter. Number counts in excess of 1012 particles per liter were found in both the City of Los Angeles Hyperion mesophilic digested sludge and the Los Angeles County Sanitation Districts (LACSD) digested primary sludge. More than 90 percent of the particles had diameters less than 10 microns.

Total and dissolved trace metals (Ag, Cd, Cr, Cu, Fe, Mn, Ni, Pb, and Zn) were measured in LACSD sludge. Manganese was the only metal whose dissolved fraction exceeded one percent of the total metal. Sedimentation experiments for several dilutions of LACSD sludge in seawater showed that the sedimentation velocities of the sludge particles decreased as the dilution factor increased. A tenfold increase in dilution shifted the sedimentation velocity distribution by an order of magnitude. Chromium, Cu, Fe, Ni, Pb, and Zn were also followed during sedimentation. To a first approximation these metals behaved like the particles.

Solids and selected trace metals (Cr, Cu, Fe, Ni, Pb, and Zn) were monitored in oxic mixtures of both Hyperion and LACSD sludges for periods of 10 to 28 days. Less than 10 percent of the filterable solids dissolved or were oxidized. Only Ni was mobilized away from the particles. The majority of the mobilization was complete in less than one day.

The experimental data of this work were combined with oceanographic, biological, and geochemical information to propose and model the discharge of digested sludge to the San Pedro and Santa Monica Basins. A hydraulic computer simulation for a round buoyant jet in a density stratified medium showed that discharges of sludge effluent mixture at depths of 730 m would rise no more than 120 m. Initial jet mixing provided dilution estimates of 450 to 2600. Sedimentation analyses indicated that the solids would reach the sediments within 10 km of the point discharge.

Mass balances on the oxidizable chemical constituents in sludge indicated that the nearly anoxic waters of the basins would become wholly anoxic as a result of proposed discharges. From chemical-equilibrium computer modeling of the sludge digester and dilutions of sludge in anoxic seawater, it was predicted that the chemistry of all trace metals except Cr and Mn will be controlled by the precipitation of metal sulfide solids. This metal speciation held for dilutions up to 3000.

The net environmental impacts of this scheme should be salutary. The trace metals in the sludge should be immobilized in the anaerobic bottom sediments of the basins. Apparently no lifeforms higher than bacteria are there to be disrupted. The proposed deep-water discharges would remove the need for potentially expensive and energy-intensive land disposal alternatives and would end the discharge to the highly productive water near the ocean surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The sludge generated by sewage treatment which meets regulatory standards can be used in agriculture. With this understanding, the focus of this study is the evaluation of the agricultural characteristics and inorganic substances in excess activated sludge, which was subjected to drying in a greenhouse. The variables (factor) evaluated during the drying process were: type of sludge (digested or not digested), addition of lime to the sludge, and the physical layout and rotation of sludge in the greenhouse. The parameters monitored for this assessment were moisture, volatile solids and pH. The greenhouse cover and sides were made of translucent plastic to allow the penetration of solar radiation and prevent water from entering. A impermeable floor was used. The sludge was generated in sewage treatment plants located in the metropolitan region of Grande Vitoria, Espirito Santo, Brazil. The solar drying of wastewater sludge in a greenhouse presented satisfactory results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper examines whether there was an excess of deaths and the relative role of temperature and ozone in a heatwave during 7–26 February 2004 in Brisbane, Australia, a subtropical city accustomed to warm weather. The data on daily counts of deaths from cardiovascular disease and non-external causes, meteorological conditions, and air pollution in Brisbane from 1 January 2001 to 31 October 2004 were supplied by the Australian Bureau of Statistics, Australian Bureau of Meteorology, and Queensland Environmental Protection Agency, respectively. The relationship between temperature and mortality was analysed using a Poisson time series regression model with smoothing splines to control for nonlinear effects of confounding factors. The highest temperature recorded in the 2004 heatwave was 42°C compared with the highest recorded temperature of 34°C during the same periods of 2001–2003. There was a significant relationship between exposure to heat and excess deaths in the 2004 heatwave estimated increase in non-external deaths: 75 [(95% confidence interval, CI: 11–138; cardiovascular deaths: 41 (95% CI: −2 to 84)]. There was no apparent evidence of substantial short-term mortality displacement. The excess deaths were mainly attributed to temperature but exposure to ozone also contributed to these deaths.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite recent developments in fixed-film combined biological nutrients removal (BNR) technology; fixed-film systems (i.e., biofilters), are still at the early stages of development and their application has been limited to a few laboratory-scale experiments. Achieving enhanced biological phosphorus removal in fixed-film systems requires exposing the micro-organisms and the waste stream to alternating anaerobic/aerobic or anaerobic/anoxic conditions in cycles. The concept of cycle duration (CD) as a process control parameter is unique to fixed-film BNR systems, has not been previously investigated, and can be used to optimise the performance of such systems. The CD refers to the elapsed time before the biomass is re-exposed to the same environmental conditions in cycles. Fixed-film systems offer many advantages over suspended growth systems such as reduced operating costs, simplicity of operation, absence of sludge recycling problems, and compactness. The control of nutrient discharges to water bodies, improves water quality, fish production, and allow water reuse. The main objective of this study was to develop a fundamental understanding of the effect of CD on the transformations of nutrients in fixed-film biofilter systems subjected to alternating aeration I no-aeration cycles A fixed-film biofilter system consisting of three up-flow biofilters connected in series was developed and tested. The first and third biofilters were operated in a cyclic mode in which the biomass was subjected to aeration/no-aeration cycles. The influent wastewater was simulated aquaculture whose composition was based on actual water quality parameters of aquacuture wastewater from a prawn grow-out facility. The influent contained 8.5 - 9:3 mg!L a111monia-N, 8.5- 8.7 mg/L phosphate-P, and 45- 50 mg!L acetate. Two independent studies were conducted at two biofiltration rates to evaluate and confirm the effect of CD on nutrient transformations in the biofilter system for application in aquaculture: A third study was conducted to enhance denitrification in the system using an external carbon- source at a rate varying from 0-24 ml/min. The CD was varied in the range of0.25- 120 hours for the first two studies and fixed at 12 hours for the third study. This study identified the CD as an important process control parameter that can be used to optimise the performance of full-scale fixed-film systems for BNR which represents a novel contribution in this field of research. The CD resulted in environmental conditions that inhibited or enhanced nutrient transformations. The effect of CD on BNR in fixed-film systems in terms of phosphorus biomass saturation and depletion has been established. Short CDs did not permit the establishment of anaerobic activity in the un-aerated biofilter and, thus, inhibited phosphorus release. Long CDs resulted in extended anaerobic activity and, thus, resulted in active phosphorus release. Long CDs, however, resulted in depleting the biomass phosphorus reservoir in the releasing biofilter and saturating the biomass phosphorus reservoir in the up-taking biofilter in the cycle. This phosphorus biomass saturation/depletion phenomenon imposes a practical limit on how short or long the CD can be. The length of the CD should be somewhere just before saturation or depletion occur and for the system tested, the optimal CD was 12 hours for the biofiltration rates tested. The system achieved limited net phosphorus removal due to the limited sludge wasting and lack of external carbon supply during phosphorus uptake. The phosphorus saturation and depletion reflected the need to extract phosphorus from the phosphorus-rich micro-organisms, for example, through back-washing. The major challenges of achieving phosphorus removal in the system included: (I) overcoming the deterioration in the performance of the system during the transition period following the start of each new cycle; and (2) wasting excess phosphorus-saturated biomass following the aeration cycle. Denitrification occurred in poorly aerated sections of the third biofilter and generally declined as the CD increased and as the time progressed in the individual cycle. Denitrification and phosphorus uptake were supplied by an internal organic carbon source, and the addition of an external carbon source (acetate) to the third biofilter resulted in improved denitrification efficiency in the system from 18.4 without supplemental carbon to 88.7% when the carbon dose reached 24 mL/min The removal of TOC and nitrification improved as the CD increased, as a result of the reduction in the frequency of transition periods between the cycles. A conceptual design of an effective fixed-film BNR biofilter system for the treatment of the influent simulated aquaculture wastewater was proposed based on the findings of the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective.To estimate the excess length of stay in an intensive care unit (ICU) due to a central line–associated bloodstream infection (CLABSI), using a multistate model that accounts for the timing of infection. Design.A cohort of 3,560 patients followed up for 36,806 days in ICUs. Setting.Eleven ICUs in 3 Latin American countries: Argentina, Brazil, and Mexico. Patients.All patients admitted to the ICU during a defined time period with a central line in place for more than 24 hours. Results.The average excess length of stay due to a CLABSI increased in 10 of 11 ICUs and varied from −1.23 days to 4.69 days. A reduction in length of stay in Mexico was probably caused by an increased risk of death due to CLABSI, leading to shorter times to death. Adjusting for patient age and Average Severity of Illness Score tended to increase the estimated excess length of stays due to CLABSI. Conclusions.CLABSIs are associated with an excess length of ICU stay. The average excess length of stay varies between ICUs, most likely because of the case‐mix of admissions and differences in the ways that hospitals deal with infections.