884 resultados para enantiomer separation


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of electrophoretic computer models and their use for simulation of electrophoretic processes has increased significantly during the last few years. Recently, GENTRANS and SIMUL5 were extended with algorithms that describe chemical equilibria between solutes and a buffer additive in a fast 1:1 interaction process, an approach that enables simulation of the electrophoretic separation of enantiomers. For acidic cationic systems with sodium and H3 0(+) as leading and terminating components, respectively, acetic acid as counter component, charged weak bases as samples, and a neutral CD as chiral selector, the new codes were used to investigate the dynamics of isotachophoretic adjustment of enantiomers, enantiomer separation, boundaries between enantiomers and between an enantiomer and a buffer constituent of like charge, and zone stability. The impact of leader pH, selector concentration, free mobility of the weak base, mobilities of the formed complexes and complexation constants could thereby be elucidated. For selected examples with methadone enantiomers as analytes and (2-hydroxypropyl)-β-CD as selector, simulated zone patterns were found to compare well with those monitored experimentally in capillary setups with two conductivity detectors or an absorbance and a conductivity detector. Simulation represents an elegant way to provide insight into the formation of isotachophoretic boundaries and zone stability in presence of complexation equilibria in a hitherto inaccessible way.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A simple method for the measurement of pindolol enantiomers by HPLC is presented. Alkalinized serum or urine is extracted with ethyl acetate and the residue remaining after evaporation of the organic layer is then derivatised with (S)-(-)-alpha-methylbenzyl isocyanate. The diastereoisomers of derivatised pindolol and metoprolol (internal standard) are separated by high-performance liquid chromatography (HPLC) using a C-18 silica column and detected using fluorescence (excitation lambda: 215 nm, emission lambda: 320 nm). The assay displays reproducible linearity for pindolol enantiomers with a correlation coefficient of r(2) greater than or equal to 0.998 over the concentration range 8-100 ng ml(-1) for plasma and 0.1-2.5 mu g ml(-1) for urine. The coefficient of variation for accuracy and precision of the quality control samples for both plasma and urine are consistently

Relevância:

60.00% 60.00%

Publicador:

Resumo:

La separació d’enantiòmers (isòmers òptics) és molt important en molts diversos camps, com les síntesis quirals, biologia, i en el camp de la farmacologia especialment. És per això, que es fa necessari de disposar de tècniques i mètodes analítics ràpids, fiables i sensibles per a la separació d’enantiòmers. La present tesi s’emmarca en el camp de la separació d’enantiòmers, concretament en la preparació de fases estacionàries quirals per al seu ús en cromatografia liquida. En aquest sentit, s’ha desenvolupat la síntesi i caracterització de molècules polimèriques quirals derivades de l’aminoàcid L-prolina que incorporades en matrius de gel de sílice poden constituïr columnes quirals per a la separació d’enantiòmers per cromatografia liquida. S’han estudiat les característiques enantioselectives d’aquests nous materials en la separació de molècules quirals, trobant-se ésser satisfactòriament enantioselectius. L’interès que suscita l’obtenció d’enantiòmers a gran escala fa que la recerca s’orienti a la recerca de materials amb elevada capacitat de càrrega, és a dir, que puguin donar lloc a la separació d’elevades quantitats d’enantiòmers. Amb aquesta finalitat s’han dut a terme assaigs de capacitat de càrrega, que han posat de manifest la possible aplicació d’aquests materials a la separació preparativa d’enantiòmers. També s’ha parat especial atenció a l’estudi de les característiques de la matriu de gel de sílice, assajant-se altres materials de sílice més porosos i que permeten així treballar amb fluxos més elevats tot reduint-ne el temps d’anàlisi i els costos associats a la separació preparativa d’enantiòmers. L'estudi conformacional d'aquests nous selectors també ha estat contemplat per tal d'explicar l'enantioselectivitat específica que s'observa en certs dissolvents orgànics en els qual es duu a terme la separació dels enantiòmers.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Enantiomeerit ovat yhdisteitä, jotka ovat toistensa peilikuvamuotoja. Enantiomeerien erotusmenetelmiä ovat neste-nesteuutto, kalvotekniikka, kiteytys, kromatografia ja kapillaarielektroforeesi. Nestekromatografinen erotus perustuu joko suoraan erotukseen tai epäsuoraan erotukseen. Kiraaliset stationaarifaasit erottavat yhdisteet kolonnissa suoralla erotuksella. Derivoimattomia aminohappojen enantiomeerejä on erotettu käyttäen ligandinvaihto-, kruunueetteri-, antibiootti- ja polysakkaridistationaarifaaseja. Epäsuora erotus vaatii erotettavan enantiomeeriparin esikäsittelyn ennen kolonnia. Markkinoilta löytyy niukasti preparatiiviseen mittakaavaan soveltuvia enantiomeerien erotusmateriaaleja. Työn kokeellisessa osassa enantiomeerien erotuksia tehtiin sekä analyyttisessä mittakaavassa että preparatiivisessa mittakaavassa. Tutkittavina pääkomponentteina aminohapoista olivat metioniinin, proliinin ja seriinin enantiomeeriparit. Analyyttisessä mittakaavassa kuparimuotoisella ligandinvaihtokolonnilla tehty erotus onnistui erittäin hyvin. Piikkien resoluutioiden arvot vaihtelivat tyypillisesti välillä 2,0-35 ja erotustekijöiden arvot välillä 1,5-30. Parhaiten onnistuttiin erottamaan metioniinin enantiomeerit toisistaan. Prepatatiivisen mittakaavan erotusmateriaalin tutkimus keskittyi materiaalin kokeiluun ja kehitykseen aminohappojen enantiomeerien erotukseen soveltuvaksi. Erotusmateriaalilla onnistuttiin erottamaan aminohappoja toisistaan, mutta aminohappojen enantiomeerien erottumista ei onnistuttu selkeästi havaitsemaan. Erotusmateriaali toimi parhaiten muunnettuna alkaalisissa olosuhteissa kuparimuotoiseksi. Kuparin pysymättömyys erotusmateriaalissa aiheutti kuitenkin ongelmia kokeiden toistettavuuteen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this work the separation of the chiral anesthetic compounds ketamine and bupivacaine was development using two chiral stationary phases (CSP). Ketamine enantiomers were well separate in the polysaccharide-based CSP (microcrystalline cellulose triacetate - MCTA) while bupivacaine in the tartardiamide-based CSP (Kromasil CHI-TBB). In both cases, the effect of temperature was investigated under analytical conditions. An improvement in the separation performance with temperature was observed. Thermodynamic parameters were evaluated by the van't Hoff plot. We concluded that enthalpic effects controlled the retention in these chiral columns. The enantiomers of ketamine and bupivacaine were separated under overloaded conditions with a good performance.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Suuri osa käytössä olevista lääkeaineista on kiraalisia yhdisteitä. Lääkevalmisteet sisältävät yhdisteen enantiomeerien ominaisuuksista riippuen joko yksittäistä enantiomeeria tai näiden seosta. Antitromboottisiin eli veren hyytymistä estäviin lääkeaineisiin kuuluvat varfariini ja rivaroksabaani ovat kiraalisia yhdisteitä, joiden enantiomeerien ominaisuudet poikkeavat antitromboottisen vaikutuksen voimakkuuden suhteen. Varfariinia käytetään kliinisesti enantiomeeriensa raseemisena seoksena, kun taas rivaroksabaani on käytössä lääkevalmisteena puhtaana S-enantiomeerinaan. Lääkeaineen enantiomeerien erottaminen toisistaan on tärkeää esimerkiksi enantiomeerien puhdistamiseksi, lääkevalmisteen oikean koostumuksen varmistamiseksi tai yksittäisten enantiomeerien käyttäytymisen arvioimiseksi elimistössä. Tässä kirjallisuustyössä käsiteltiin nestekromatografian käyttöä antitromboottisiin lääkeaineisiin kuuluvien antikoagulanttien enantiomeerien fraktioinnissa. Kirjallisuudesta saadun tiedon perusteella arvioitiin, millä erotusmateriaaleilla ja millaisissa koeolosuhteissa varfariinin sekä rivaroksabaanin enantiomeerit tulisi erottaa toisistaan. Varfariinin enantiomeerien erotukseen parhaiten sopivaksi erotusmateriaaliksi todettiin kirjallisuuden perusteella kiraalinen vankomysiinipohjainen stationaarifaasi (Chirobiotic V) metanolin, etikkahapon ja veden seoksen toimiessa eluenttina. Eluentin virtausnopeudella 0,3 mL/min ja pienellä injektiotilavuudella varfariinin enantiomeerit saatiin erottumaan täydellisesti ja nopeasti toisistaan. Kirjallisuuden perusteella rivaroksabaanin enantiomeerien erotuksessa erotusmateriaalina toimii parhaiten kiraalinen selluloosapohjainen stationaarifaasi (Chiralcel OD-RH), kun eluenttina käytetään n-heksaanin ja isopropanolin seosta virtausnopeudella 1 mL/min. Varfariinin ja rivaroksabaanin enantiomeerien fraktiointiin parhaiten sopivia menetelmiä voidaan käyttää eri tilanteissa, kuten lääkevalmisteiden laadunvarmistuksessa tai enantiomeerien erotuksessa niiden synteesin jälkeen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The enantiomers of sulfoxide proton pump inhibitors - omeprazole, lansoprazole, rabeprazole and Ro 18-5364 - were enantiomerically separated by liquid chromatography at multimilligram scale on a poly saccharide-based chiral stationary phase using normal and polar organic conditions as mobile phase. The values of the recovery and production rate were significant for each enantiomer; better results were achieved using a solid-phase injection system. However, this system was applied just for the enantionteric separation of omeprazole to demonstrate the applicability of this injection mode at milligram scale. The chiroptical characterization of the compounds was performed using a polarimeter and a circular dichroism detector. The higher enantiomeric purity obtained for the isolated enantiomers suggests that the methods here described should be considered as a simple and rapid way to obtain enantiomeric pure standards for analytical purpose. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In this thesis we will disclose the results obtained from the diastereoisomeric salt formation (n salt, p salt and p1,n1 salt) between non-racemic trans-chrysanthemic acid (trans-ChA) and pure enantiomers of threo-2-dimethylamino-1-phenyl-1,3-propanediol (DMPP). The occurrence of p1,n1 salt formation can have profound effects on enantiomer separation of scalemic (non-racemic) mixtures. This phenomenon when accompanied by substrate self-association impedes the complete recovery of the major enantiomer through formation of an inescapable racemate cage. A synthetic sequence for the asymmetric synthesis of bicyclo[3.2.0]heptanones and bicyclo[3.2.0]hept-3-en-6-ones through a cycloaddition strategy is reported. The fundamental step is a [2+2]-cycloaddition of an enantiopure amide derived from the reaction between a set of acids and an oxazolidinone as the chiral auxiliary. The inter- and intramolecular cycloaddition of in situ-generated keteniminium salts gives bicycles with a good enantioselection. A key intermediate of Iloprost, a chemically stable and biologically active mimic of prostacyclin PGI2 is synthesized following a ‘green approach’. An example of simple optical resolution of this racemic intermediate involving the diastereoisomeric salt formation is described.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One-dimensional dynamic computer simulation was employed to investigate the separation and migration order change of ketoconazole enantiomers at low pH in presence of increasing amounts of (2-hydroxypropyl)-β-cyclodextrin (OHP-β-CD). The 1:1 interaction of ketoconazole with the neutral cyclodextrin was simulated under real experimental conditions and by varying input parameters for complex mobilities and complexation constants. Simulation results obtained with experimentally determined apparent ionic mobilities, complex mobilities, and complexation constants were found to compare well with the calculated separation selectivity and experimental data. Simulation data revealed that the migration order of the ketoconazole enantiomers at low (OHP-β-CD) concentrations (i.e. below migration order inversion) is essentially determined by the difference in complexation constants and at high (OHP-β-CD) concentrations (i.e. above migration order inversion) by the difference in complex mobilities. Furthermore, simulations with complex mobilities set to zero provided data that mimic migration order and separation with the chiral selector being immobilized. For the studied CEC configuration, no migration order inversion is predicted and separations are shown to be quicker and electrophoretic transport reduced in comparison to migration in free solution. The presented data illustrate that dynamic computer simulation is a valuable tool to study electrokinetic migration and separations of enantiomers in presence of a complexing agent.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A computer simulation study describing the electrophoretic separation and migration of methadone enantiomers in presence of free and immobilized (2-hydroxypropyl)-β-CD is presented. The 1:1 interaction of methadone with the neutral CD was simulated by using experimentally determined mobilities and complexation constants for the complexes in a low-pH BGE comprising phosphoric acid and KOH. The use of complex mobilities represents free solution conditions with the chiral selector being a buffer additive, whereas complex mobilities set to zero provide data that mimic migration and separation with the chiral selector being immobilized, that is CEC conditions in absence of unspecific interaction between analytes and the chiral stationary phase. Simulation data reveal that separations are quicker, electrophoretic displacement rates are reduced, and sensitivity is enhanced in CEC with on-column detection in comparison to free solution conditions. Simulation is used to study electrophoretic analyte behavior at the interface between sample and the CEC column with the chiral selector (analyte stacking) and at the rear end when analytes leave the environment with complexation (analyte destacking). The latter aspect is relevant for off-column analyte detection in CEC and is described here for the first time via the dynamics of migrating analyte zones. Simulation provides insight into means to counteract analyte dilution at the column end via use of a BGE with higher conductivity. Furthermore, the impact of EOF on analyte migration, separation, and detection for configurations with the selector zone being displaced or remaining immobilized under buffer flow is simulated. In all cases, the data reveal that detection should occur within or immediately after the selector zone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Biotecnologia

Relevância:

30.00% 30.00%

Publicador:

Resumo:

GENTRANS, a comprehensive one-dimensional dynamic simulator for electrophoretic separations and transport, was extended for handling electrokinetic chiral separations with a neutral ligand. The code can be employed to study the 1:1 interaction of monovalent weak and strong acids and bases with a single monovalent weak or strong acid or base additive, including a neutral cyclodextrin, under real experimental conditions. It is a tool to investigate the dynamics of chiral separations and to provide insight into the buffer systems used in chiral capillary zone electrophoresis (CZE) and chiral isotachophoresis. Analyte stacking across conductivity and buffer additive gradients, changes of additive concentration, buffer component concentration, pH, and conductivity across migrating sample zones and peaks, and the formation and migration of system peaks can thereby be investigated in a hitherto inaccessible way. For model systems with charged weak bases and neutral modified β-cyclodextrins at acidic pH, for which complexation constants, ionic mobilities, and mobilities of selector-analyte complexes have been determined by CZE, simulated and experimentally determined electropherograms and isotachopherograms are shown to be in good agreement. Simulation data reveal that CZE separations of cationic enantiomers performed in phosphate buffers at low pH occur behind a fast cationic migrating system peak that has a small impact on the buffer composition under which enantiomeric separation takes place.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Brazil, the consumption of extra-virgin olive oil (EVOO) is increasing annually, but there are no experimental studies concerning the phenolic compound contents of commercial EVOO. The aim of this work was to optimise the separation of 17 phenolic compounds already detected in EVOO. A Doehlert matrix experimental design was used, evaluating the effects of pH and electrolyte concentration. Resolution, runtime and migration time relative standard deviation values were evaluated. Derringer's desirability function was used to simultaneously optimise all 37 responses. The 17 peaks were separated in 19min using a fused-silica capillary (50μm internal diameter, 72cm of effective length) with an extended light path and 101.3mmolL(-1) of boric acid electrolyte (pH 9.15, 30kV). The method was validated and applied to 15 EVOO samples found in Brazilian supermarkets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Local parity-odd domains are theorized to form inside a quark-gluon plasma which has been produced in high-energy heavy-ion collisions. The local parity-odd domains manifest themselves as charge separation along the magnetic field axis via the chiral magnetic effect. The experimental observation of charge separation has previously been reported for heavy-ion collisions at the top RHIC energies. In this Letter, we present the results of the beam-energy dependence of the charge correlations in Au+Au collisions at midrapidity for center-of-mass energies of 7.7, 11.5, 19.6, 27, 39, and 62.4 GeV from the STAR experiment. After background subtraction, the signal gradually reduces with decreased beam energy and tends to vanish by 7.7 GeV. This implies the dominance of hadronic interactions over partonic ones at lower collision energies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traveling wave ion mobility mass spectrometry (TWIM-MS) is shown to be able to separate and characterize several isomeric forms of diterpene glycosides stevioside (Stv) and rebaudioside A (RebA) that are cationized by Na(+) and K(+) at different sites. Determination and characterization of these coexisting isomeric species, herein termed catiomers, arising from cationization at different and highly competitive coordinating sites, is particularly challenging for glycosides. To achieve this goal, the advantage of using CO2 as a more massive and polarizable drift gas, over N2 , was demonstrated. Post-TWIM-MS/MS experiments were used to confirm the separation. Optimization of the possible geometries and cross-sectional calculations for mobility peak assignments were also performed. Copyright © 2015 John Wiley & Sons, Ltd.