378 resultados para eletrodo
Resumo:
Copper electrode can be used for determination of complexing compounds through complexation reactions between Cu(II) and the analites. In this work some studies with three compounds were performed: glycine (precursor of glyphosate synthesis), herbicide glyphosate and aminomethylphosphonic acid (main metabolite of glyphosate). These compounds are complexing agents for Cu electrodes. Through simple experiments (cyclic voltammetry and corrosion studies) the applicability of the copper electrode as electrochemical sensor for complexing compounds in flow systems was presented.
Resumo:
A composite electrode prepared by mixing a commercial epoxy resin Araldite® and graphite powder is proposed to be used in didactic experiments. The electrode is prepared by the students and applied in simple experiments to demonstrate the effect of the composite composition on the conductivity and the voltammetric response of the resulting electrode, as well as the response in relation to the scan rate dependence on mass transport. The possibility of using the composite electrode in quantitative analysis is also demonstrated.
Resumo:
The results of an exercise on electrochemistry for General Chemistry students are presented. The difficulty encountered by students in predicting the shift in the potential of the hydrogen electrode under non-standard conditions prompted a search in textbooks on how the subject is developed. Besides several instances of inconsistencies in defining the standard state, such as including the temperature in the definition, a number of incorrect depictions of the hydrogen electrode were discovered. Of the 28 General Chemistry books, 16 Physical Chemistry books and 24 Internet pages, 30, 20 and 46%, respectively, showed devices that would not work in practice.
Resumo:
OBJETIVOS: Trabalho prospectivo, randomizado para comparar a eficácia e a segurança do cateter irrigado em relação ao cateter com eletrodo distal de 8 mm para ablação com radiofreqüência (RF) do flutter atrial. MÉTODOS: Em 52 pacientes consecutivos referidos para tratamento do flutter atrial tÃpico, a ablação do istmo cavotricuspÃdeo (Ist-CT) foi realizada com cateter de irrigação fechada (n=26) ou com cateter de eletrodo distal de 8 mm (n=26). Os pulsos de RF foram aplicados ponto a ponto por 60 segundos com potência limitada a 50 w com o cateter irrigado e por controle de temperatura (60ºC, 70 w) com cateter de 8 mm. O critério de fim do procedimento foi a obtenção de bloqueio bidirecional do Ist-CT. RESULTADOS: O bloqueio Ist-CT foi obtido em 98,1% dos pacientes. O "crossover" ocorreu em quatro pacientes do grupo com cateter irrigado. Não se encontrou diferença estatÃstica significante em relação aos parâmetros da ablação, tais como tempo total de aplicação de RF (591,1±309,0s vs 486,2±250,8s), duração do procedimento (86,4 ± 23,6 vs 78,1±22,5min) e tempo de fluoroscopia (17,0±6,7 vs 15,4±4,6min) entre os dois grupos. Durante seguimento médio de 10,6 meses, um paciente do grupo irrigado apresentou recorrência do flutter atrial tÃpico. CONCLUSÃO: A ablação do Ist-CT resultou ser efetiva e segura para o controle do flutter atrial com ambas as técnicas empregadas (cateter com eletrodo distal de 8 mm e cateter irrigado). A complexidade técnica do cateter irrigado proporciona menor competitividade.
Resumo:
Apresentamos o caso de um paciente portador da forma cardÃaca da doença de Chagas com disfunção ventricular esquerda e bloqueio atrioventricular de 2º grau Mobitz II, associados a vários episódios de sÃncope. Foi submetido a implante de marcapasso artificial definitivo dupla câmara. Após um ano do implante foi diagnosticado deslocamento de eletrodo atrial, sendo submetido a reimplante de eletrodo atrial. Após dois anos do primeiro procedimento cirúrgico, apresentava dispneia aos grandes esforços. Durante a avaliação, foi solicitado ecocardiograma, que detectou a presença de corpo estranho de caracterÃsticas metálicas em câmaras cardÃacas esquerdas, consistente com eletrodo de marcapasso ectópico.
Resumo:
Relatamos caso de implantação anômala de eletrodo de marca-passo VVI no ventrÃculo esquerdo (VE), diagnosticada durante avaliação de rotina, dois anos pós-implante. Trata-se de mulher de 65 anos e soropositiva para doença de Chagas. O eletrocardiograma (ECG) apresentava padrão de bloqueio do ramo direito. A radiografia de tórax em perfil mostrou trajeto com curvatura posterior do eletrodo. No ecocardiograma transtorácico, o diagnóstico final mostrou cateter que penetrava o átrio direito, atravessava o septo interatrial e descia pelo átrio esquerdo e orifÃcio valvar mitral para se implantar na parede lateral do VE. Abordam-se os seguintes aspectos relacionados: possÃveis trajetos de implantação, quadro clÃnico, radiológico, eletrocardiográfico, ecocardiográfico, complicações e opções terapêuticas.
Resumo:
A avaliação do limiar de desfibrilação (DFT) durante o implante do cardioversor-desfibrilador (CDI) é uma etapa relevante do procedimento, uma vez que, em até 16% dos pacientes, podemos encontrar elevados DFT. Relatamos o caso de um paciente portador de cardiomiopatia dilatada (CMPD) idiopática submetido a implante de CDI biventricular. Durante o procedimento, apresentou elevado DFT e se mostrou resistente às modalidades terapêuticas usuais. Optamos pelo implante de eletrodo de desfibrilação em veia ázigos, com resolução do quadro.
Resumo:
In this paper is presented electrochemical evidences of the influence of the light on the electrochemical behavior of nickel electrode in diluted sulfuric acid. The current densities related with the electrooxidation of the metal decreases when the electrode is under illumination. The corrosion potential, Ecorr , shift to a more positive value in this condition. This effect was observed with polychromatic light and with different wavelength glass filters such as 700 nm and 520 nm. It was observed that increasing the temperature of the solution, the current densities related with cathodic and anodic processes, increases instead of decreases. The activation energy related with the electrooxidation of the electrode was higher under illumination than in the dark. It is suggested that this behavior may be related or with a photo-inhibition effect either with dessorption of adsorbed water involved in the electrooxidation mechanism.
Resumo:
The construction of a tubular hydrogen ion-selective potentiometric electrode without inner reference solution, based on the tridodecylamine (TDDA) ionophore, and its evaluation in a flow system are described. TDDA was dissolved in 2-nitrophenyl octyl ether, dispersed in a PVC membrane and applied directly to a conducting support which consisted of an epoxy resin and graphite mixture. The electrode was designed with a tubular geometry to effort facilities to be coupled as part of a flow injection network. The main working characteristics such as response time, linear pH range, selectivity and life time were evaluated and compared with those obtained which a conventionally shaped electrode based on the same sensor. The electrode showed a slope of 51-52 mV dec-1 within a linear pH range from 4.0 up to 12.0.
Resumo:
The alizarin red S (ARS) has been used as a spectrophotometric reagent of several metals for a long time. Now this alizarin has been used as modifier agent of electrodes, for voltammetric analyses. In this work cyclic voltammetry experiments was accomplished on closed circuit, with the objective of studying the voltammetric behavior of alizarin red S adsorbed and of its copper complex, on the surface of the pyrolytic graphite electrode. These studies showed that ARS strongly adsorbs on the surface of this electrode. This adsorption was used to immobilize ions copper(II) from the solution.
Resumo:
This study presents an automated system for potentiometric determination of free and total cyanide which employs a homogeneous membrane tubular ion-selective electrode. After the electrode is assembled, it is connected to a system composed of 3 three-way solenoid valves, sample line, carrier line, acid stream, and gas diffusion chamber. A Turbo Pascal® computer program, developed specifically for this task, automatically performs all the steps involved in data acquisition and processing. The proposed analytical procedure offers operational simplicity, since detection is performed by a tubular electrode, whose assembly is fast and easy. The system has shown reproducibility (r.s.d. < 0.5%, n=6) and high speed (30 readings/hour); it is efficient for determination of free and total cyanide in waste waters of starch processing plants. The detection limit was 1.2x10-5 and 1.5x10-5 mol L-1, for determination of free and total cyanide, respectively. The linear response range was between 1.2x10-5 and 1.0x10-2 mol L-1 for free cyanide and between 1.5x10-5 and 1.0x10-2 for total cyanide.
Resumo:
This paper presents some results on the employ of recycled graphite electrode obtained from used common 1.5 V batteries in the preparation of modified electrode and the electrocatalytical hydrogenation of benzaldehyde and of n-valeraldehyde. This inexpensive and easy to obtain electrode was prepared by coating it with a 1:1 mixed film of poly-(allylfenil ether): poly-[allyl p-(2-ethylammonium) benzene ether] and introduction of dispersed platinum particles by ion exchange and reduction of PtCl4-2. Electroreduction of H+ from aqueous H2SO4 using the proposed electrode hydrogenated the substrates in a way comparable with that of vitreous carbon electrode.
Resumo:
UNS S31254 SS electrodes have been built to substitute platinum in conductimetric titrations. The electrodes were tested in both acid-basic titration (chloridric acid and sodium hydroxide) and precipitation titration (sodium chloride and argentum nitrate as titrant). The practical application was exemplified from conductimetric tritations of HF <FONT FACE=Symbol>¾</FONT> HNO3 mixtures used in metalurgical industry to passivate stainless steels. The results were compared with those obtained using commercial platinum electrodes. The equivalent volumes obtained were comparable within 3% experimental error. Its application depends on the nature of electrolyte. These results have shown that stainless steel, less expensive than platinum (about three order of magnitude), can substitute platinum electrodes in routine analyses and didactic laboratories.
Resumo:
The anodic voltammetric behavior of 4-chlorophenol (4-CF) in aqueous solution has been studied on a Boron-doped diamond electrode using square wave voltammetry (SWV). After optimization of the experimental conditions, 4-CF was analyzed in pure and natural waters using a Britton-Robinson buffer with pH = 6.0 as the supporting electrolyte. Oxidation occurs at 0.80 V vs Ag/AgCl in a two-electron process controlled by adsorption of the species. The detection limits obtained were 6.4 µg L-1 in pure water and 21.5 µg L-1 for polluted water taken from a local creek, respectively. The combination of square wave voltammetry and diamond electrodes is an interesting and desirable alternative for analytical determinations.