974 resultados para effective atomic number


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The method of extracting effective atomic orbitals and effective minimal basis sets from molecular wave function characterizing the state of an atom in a molecule is developed in the framework of the "fuzzy" atoms. In all cases studied, there were as many effective orbitals that have considerable occupation numbers as orbitals in the classical minimal basis. That is considered to be of high conceptual importance

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The method of extracting effective atomic orbitals and effective minimal basis sets from molecular wave function characterizing the state of an atom in a molecule is developed in the framework of the "fuzzy" atoms. In all cases studied, there were as many effective orbitals that have considerable occupation numbers as orbitals in the classical minimal basis. That is considered to be of high conceptual importance

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pour analyser les images en tomodensitométrie, une méthode stœchiométrique est gé- néralement utilisée. Une courbe relie les unités Hounsfield d’une image à la densité électronique du milieu. La tomodensitométrie à double énergie permet d’obtenir des informations supplémentaires sur ces images. Une méthode stœchiométrique a été dé- veloppée pour permettre de déterminer les valeurs de densité électronique et de numéro atomique effectif à partir d’une paire d’images d’un tomodensitomètre à double énergie. Le but de cette recherche est de développer une nouvelle méthode d’identification de tissus en utilisant ces paramètres extraits en tomodensitométrie à double énergie. Cette nouvelle méthode est comparée avec la méthode standard de tomodensitométrie à simple énergie. Par ailleurs, l’impact dosimétrique de bien identifier un tissu est déterminé. Des simulations Monte Carlo permettent d’utiliser des fantômes numériques dont tous les paramètres sont connus. Les différents fantômes utilisés permettent d’étalonner les méthodes stœchiométriques, de comparer la polyvalence et la robustesse des méthodes d’identification de tissus double énergie et simple énergie, ainsi que de comparer les distributions de dose dans des fantômes uniformes de mêmes densités, mais de compo- sitions différentes. La méthode utilisant la tomodensitométrie à double énergie fournit des valeurs de densi- tés électroniques plus exactes, quelles que soient les conditions étudiées. Cette méthode s’avère également plus robuste aux variations de densité des tissus. L’impact dosimé- trique d’une bonne identification de tissus devient important pour des traitements aux énergies plus faibles, donc aux énergies d’imagerie et de curiethérapie.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work is to impart radiopacity in various natural polymers like chitosan, natural rubber and derivatives of chitosan and to characterize it. This thesis collated the radiopaque properties of these radiopaque polymers and various technological applications in the medical field. The applications of radiopaque polymers leads to an exploitation of radiopaque properties like X-ray visibility, optical density, effective atomic number, attenuation coefficient of biopolymers like chitosan, chitosan formate, chitosan acetate, carboxy methyl chitosan and natural rubber. The radiopaqe properties of these materials highly depend upon the size, shape, amount of radiopacifier and crystallinity of the radiopaque material. Radiopaque chitosan microspheres were prepared by cross linking with glutaraldehyde followed by the encapsulation of barium sulpahte. The effect of different emulsion systems on the morphology of chitosan microspheres were studied. The study concentrates radiopaque natural rubber for shielding applications. It reveals that to improve the particle size, morphology and crystalline phase of the zinc oxide particles, a novel method for the preparation of zinc oxide is adopted. A detailed radiopacity study was done in natural rubber containing 100phr precipitated zinc oxide prepared from different zinc salts. One of the significant findings of this investigation is that NR vulcanizates containing precipitated zinc oxide (from zinc acetate) shows higher attenuation coefficient. These interesting findings reveal the applications of these natural radiopaque systems in various fields like surgical tools, medical tubings, catheters, radiation shielding,etc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we measured X-ray scatter spectra from normal and neoplastic breast tissues using photon energy of 17.44 key and a scattering angle of 90 degrees, in order to study the shape (FWHM) of the Compton peaks. The obtained results for FWHM were discussed in terms of composition and histological characteristics of each tissue type. The statistical analysis shows that the distribution of FWHM of normal adipose breast tissue clearly differs from all other investigated tissues. Comparison between experimental values of FWHM and effective atomic number revealed a strong correlation between them, showing that the FWHM values can be used to provide information about elemental composition of the tissues. (C) 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new multi-energy CT for small animals is being developed at the Physics Department of the University of Bologna, Italy. The system makes use of a set of quasi-monochromatic X-ray beams, with energy tunable in a range from 26 KeV to 72 KeV. These beams are produced by Bragg diffraction on a Highly Oriented Pyrolytic Graphite crystal. With quasi-monochromatic sources it is possible to perform multi-energy investigation in a more effective way, as compared with conventional X-ray tubes. Multi-energy techniques allow extracting physical information from the materials, such as effective atomic number, mass-thickness, density, that can be used to distinguish and quantitatively characterize the irradiated tissues. The aim of the system is the investigation and the development of new pre-clinic methods for the early detection of the tumors in small animals. An innovative technique, the Triple-Energy Radiography with Contrast Medium (TER), has been successfully implemented on our system. TER consist in combining a set of three quasi-monochromatic images of an object, in order to obtain a corresponding set of three single-tissue images, which are the mass-thickness map of three reference materials. TER can be applied to the quantitative mass-thickness-map reconstruction of a contrast medium, because it is able to remove completely the signal due to other tissues (i.e. the structural background noise). The technique is very sensitive to the contrast medium and is insensitive to the superposition of different materials. The method is a good candidate to the early detection of the tumor angiogenesis in mice. In this work we describe the tomographic system, with a particular focus on the quasi-monochromatic source. Moreover the TER method is presented with some preliminary results about small animal imaging.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proton radiation therapy is gaining popularity because of the unique characteristics of its dose distribution, e.g., high dose-gradient at the distal end of the percentage-depth-dose curve (known as the Bragg peak). The high dose-gradient offers the possibility of delivering high dose to the target while still sparing critical organs distal to the target. However, the high dose-gradient is a double-edged sword: a small shift of the highly conformal high-dose area can cause the target to be substantially under-dosed or the critical organs to be substantially over-dosed. Because of that, large margins are required in treatment planning to ensure adequate dose coverage of the target, which prevents us from realizing the full potential of proton beams. Therefore, it is critical to reduce uncertainties in the proton radiation therapy. One major uncertainty in a proton treatment is the range uncertainty related to the estimation of proton stopping power ratio (SPR) distribution inside a patient. The SPR distribution inside a patient is required to account for tissue heterogeneities when calculating dose distribution inside the patient. In current clinical practice, the SPR distribution inside a patient is estimated from the patient’s treatment planning computed tomography (CT) images based on the CT number-to-SPR calibration curve. The SPR derived from a single CT number carries large uncertainties in the presence of human tissue composition variations, which is the major drawback of the current SPR estimation method. We propose to solve this problem by using dual energy CT (DECT) and hypothesize that the range uncertainty can be reduced by a factor of two from currently used value of 3.5%. A MATLAB program was developed to calculate the electron density ratio (EDR) and effective atomic number (EAN) from two CT measurements of the same object. An empirical relationship was discovered between mean excitation energies and EANs existing in human body tissues. With the MATLAB program and the empirical relationship, a DECT-based method was successfully developed to derive SPRs for human body tissues (the DECT method). The DECT method is more robust against the uncertainties in human tissues compositions than the current single-CT-based method, because the DECT method incorporated both density and elemental composition information in the SPR estimation. Furthermore, we studied practical limitations of the DECT method. We found that the accuracy of the DECT method using conventional kV-kV x-ray pair is susceptible to CT number variations, which compromises the theoretical advantage of the DECT method. Our solution to this problem is to use a different x-ray pair for the DECT. The accuracy of the DECT method using different combinations of x-ray energies, i.e., the kV-kV, kV-MV and MV-MV pair, was compared using the measured imaging uncertainties for each case. The kV-MV DECT was found to be the most robust against CT number variations. In addition, we studied how uncertainties propagate through the DECT calculation, and found general principles of selecting x-ray pairs for the DECT method to minimize its sensitivity to CT number variations. The uncertainties in SPRs estimated using the kV-MV DECT were analyzed further and compared to those using the stoichiometric method. The uncertainties in SPR estimation can be divided into five categories according to their origins: the inherent uncertainty, the DECT modeling uncertainty, the CT imaging uncertainty, the uncertainty in the mean excitation energy, and SPR variation with proton energy. Additionally, human body tissues were divided into three tissue groups – low density (lung) tissues, soft tissues and bone tissues. The uncertainties were estimated separately because their uncertainties were different under each condition. An estimate of the composite range uncertainty (2s) was determined for three tumor sites – prostate, lung, and head-and-neck, by combining the uncertainty estimates of all three tissue groups, weighted by their proportions along typical beam path for each treatment site. In conclusion, the DECT method holds theoretical advantages in estimating SPRs for human tissues over the current single-CT-based method. Using existing imaging techniques, the kV-MV DECT approach was capable of reducing the range uncertainty from the currently used value of 3.5% to 1.9%-2.3%, but it is short to reach our original goal of reducing the range uncertainty by a factor of two. The dominant source of uncertainties in the kV-MV DECT was the uncertainties in CT imaging, especially in MV CT imaging. Further reduction in beam hardening effect, the impact of scatter, out-of-field object etc. would reduce the Hounsfeld Unit variations in CT imaging. The kV-MV DECT still has the potential to reduce the range uncertainty further.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans la pratique actuelle de la curiethérapie à bas débit, l'évaluation de la dose dans la prostate est régie par le protocole défini dans le groupe de travail 43 (TG-43) de l'American Association of Physicists in Medicine. Ce groupe de travail suppose un patient homogène à base d'eau de même densité et néglige les changements dans l'atténuation des photons par les sources de curiethérapie. En considérant ces simplifications, les calculs de dose se font facilement à l'aide d'une équation, indiquée dans le protocole. Bien que ce groupe de travail ait contribué à l'uniformisation des traitements en curiethérapie entre les hôpitaux, il ne décrit pas adéquatement la distribution réelle de la dose dans le patient. La publication actuelle du TG-186 donne des recommandations pour étudier des distributions de dose plus réalistes. Le but de ce mémoire est d'appliquer ces recommandations à partir du TG-186 pour obtenir une description plus réaliste de la dose dans la prostate. Pour ce faire, deux ensembles d'images du patient sont acquis simultanément avec un tomodensitomètre à double énergie (DECT). Les artéfacts métalliques présents dans ces images, causés par les sources d’iode, sont corrigés à l'aide d’un algorithme de réduction d'artefacts métalliques pour DECT qui a été développé dans ce travail. Ensuite, une étude Monte Carlo peut être effectuée correctement lorsque l'image est segmentée selon les différents tissus humains. Cette segmentation est effectuée en évaluant le numéro atomique effectif et la densité électronique de chaque voxel, par étalonnage stoechiométrique propre au DECT, et en y associant le tissu ayant des paramètres physiques similaires. Les résultats montrent des différences dans la distribution de la dose lorsqu'on compare la dose du protocole TG-43 avec celle retrouvée avec les recommandations du TG-186.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dans la pratique actuelle de la curiethérapie à bas débit, l'évaluation de la dose dans la prostate est régie par le protocole défini dans le groupe de travail 43 (TG-43) de l'American Association of Physicists in Medicine. Ce groupe de travail suppose un patient homogène à base d'eau de même densité et néglige les changements dans l'atténuation des photons par les sources de curiethérapie. En considérant ces simplifications, les calculs de dose se font facilement à l'aide d'une équation, indiquée dans le protocole. Bien que ce groupe de travail ait contribué à l'uniformisation des traitements en curiethérapie entre les hôpitaux, il ne décrit pas adéquatement la distribution réelle de la dose dans le patient. La publication actuelle du TG-186 donne des recommandations pour étudier des distributions de dose plus réalistes. Le but de ce mémoire est d'appliquer ces recommandations à partir du TG-186 pour obtenir une description plus réaliste de la dose dans la prostate. Pour ce faire, deux ensembles d'images du patient sont acquis simultanément avec un tomodensitomètre à double énergie (DECT). Les artéfacts métalliques présents dans ces images, causés par les sources d’iode, sont corrigés à l'aide d’un algorithme de réduction d'artefacts métalliques pour DECT qui a été développé dans ce travail. Ensuite, une étude Monte Carlo peut être effectuée correctement lorsque l'image est segmentée selon les différents tissus humains. Cette segmentation est effectuée en évaluant le numéro atomique effectif et la densité électronique de chaque voxel, par étalonnage stoechiométrique propre au DECT, et en y associant le tissu ayant des paramètres physiques similaires. Les résultats montrent des différences dans la distribution de la dose lorsqu'on compare la dose du protocole TG-43 avec celle retrouvée avec les recommandations du TG-186.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The knowledge of the atomic structure of clusters composed by few atoms is a basic prerequisite to obtain insights into the mechanisms that determine their chemical and physical properties as a function of diameter, shape, surface termination, as well as to understand the mechanism of bulk formation. Due to the wide use of metal systems in our modern life, the accurate determination of the properties of 3d, 4d, and 5d metal clusters poses a huge problem for nanoscience. In this work, we report a density functional theory study of the atomic structure, binding energies, effective coordination numbers, average bond lengths, and magnetic properties of the 3d, 4d, and 5d metal (30 elements) clusters containing 13 atoms, M(13). First, a set of lowest-energy local minimum structures (as supported by vibrational analysis) were obtained by combining high-temperature first- principles molecular-dynamics simulation, structure crossover, and the selection of five well-known M(13) structures. Several new lower energy configurations were identified, e. g., Pd(13), W(13), Pt(13), etc., and previous known structures were confirmed by our calculations. Furthermore, the following trends were identified: (i) compact icosahedral-like forms at the beginning of each metal series, more opened structures such as hexagonal bilayerlike and double simple-cubic layers at the middle of each metal series, and structures with an increasing effective coordination number occur for large d states occupation. (ii) For Au(13), we found that spin-orbit coupling favors the three-dimensional (3D) structures, i.e., a 3D structure is about 0.10 eV lower in energy than the lowest energy known two-dimensional configuration. (iii) The magnetic exchange interactions play an important role for particular systems such as Fe, Cr, and Mn. (iv) The analysis of the binding energy and average bond lengths show a paraboliclike shape as a function of the occupation of the d states and hence, most of the properties can be explained by the chemistry picture of occupation of the bonding and antibonding states.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this work, we employed the effective coordination concept to study the local environments of the Ge, Sb, and Te atoms in the Ge(m)Sb(2n)Te(m+3n) compounds. From our calculations and analysis, we found an average effective coordination number (ECN) reduction of 1.59, 1.42, and 1.37, for the Ge, Sb, Te atoms in the phase transition from crystalline, ECN=5.55 (Ge), 5.73 (Sb), 4.37 (Te), to the amorphous phase, ECN=3.96 (Ge), 4.31 (Sb), 3.09 (Te), for the Ge(2)Sb(2)Te(5) composition. Similar changes are observed for other compositions. Thus, our results indicate that the coordination changes from the crystalline to amorphous phase are not large as previously assumed in the literature, i.e., from sixfold to fourfold for Ge, which can contribute to obtain a better understanding of the crystalline to amorphous phase transition. (C) 2011 American Institute of Physics. [doi:10.1063/1.3533422]

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Despite the quantum nature of the process, collective scattering by dense cold samples of two-level atoms can be interpreted classically describing the sample as a macroscopic object with a complex refractive index. We demonstrate that resonances in Mie theory can be easily observable in the cooperative scattering by tuning the frequency of the incident laser field or the atomic number. The solution of the scattering problem is obtained for spherical atomic clouds who have the parabolic density characteristic of BECs, and the cooperative radiation pressure force calculated exhibits resonances in the cloud displacement for dense clouds. At odds with uniform clouds which show a complex structure including narrow peaks, these densities show resonances, yet only under the form of quite regular and contrasted oscillations. Copyright (C) EPLA, 2012

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Graphene has received great attention due to its exceptional properties, which include corners with zero effective mass, extremely large mobilities, this could render it the new template for the next generation of electronic devices. Furthermore it has weak spin orbit interaction because of the low atomic number of carbon atom in turn results in long spin coherence lengths. Therefore, graphene is also a promising material for future applications in spintronic devices - the use of electronic spin degrees of freedom instead of the electron charge. Graphene can be engineered to form a number of different structures. In particular, by appropriately cutting it one can obtain 1-D system -with only a few nanometers in width - known as graphene nanoribbon, which strongly owe their properties to the width of the ribbons and to the atomic structure along the edges. Those GNR-based systems have been shown to have great potential applications specially as connectors for integrated circuits. Impurities and defects might play an important role to the coherence of these systems. In particular, the presence of transition metal atoms can lead to significant spin-flip processes of conduction electrons. Understanding this effect is of utmost importance for spintronics applied design. In this work, we focus on electronic transport properties of armchair graphene nanoribbons with adsorbed transition metal atoms as impurities and taking into account the spin-orbit effect. Our calculations were performed using a combination of density functional theory and non-equilibrium Greens functions. Also, employing a recursive method we consider a large number of impurities randomly distributed along the nanoribbon in order to infer, for different concentrations of defects, the spin-coherence length.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The 2014 Ebola virus (EBOV) outbreak in West Africa is the largest outbreak of the genus Ebolavirus to date. To better understand the spread of infection in the affected countries, it is crucial to know the number of secondary cases generated by an infected index case in the absence and presence of control measures, i.e., the basic and effective reproduction number. In this study, I describe the EBOV epidemic using an SEIR (susceptible-exposed-infectious-recovered) model and fit the model to the most recent reported data of infected cases and deaths in Guinea, Sierra Leone and Liberia. The maximum likelihood estimates of the basic reproduction number are 1.51 (95% confidence interval [CI]: 1.50-1.52) for Guinea, 2.53 (95% CI: 2.41-2.67) for Sierra Leone and 1.59 (95% CI: 1.57-1.60) for Liberia. The model indicates that in Guinea and Sierra Leone the effective reproduction number might have dropped to around unity by the end of May and July 2014, respectively. In Liberia, however, the model estimates no decline in the effective reproduction number by end-August 2014. This suggests that control efforts in Liberia need to be improved substantially in order to stop the current outbreak.