997 resultados para dosage rapide


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Depuis quelques années, la spectrométrie de masse en tandem (MS/MS) ne cesse de gagner du terrain comme méthode d'analyse en toxicologie forensique, notamment pour le dosage des cannabinoïdes. Couplée à la chromatographie liquide (LC) ou gazeuse (GC), elle permet l'identification fiable et le dosage rapide du THC, de son précurseur acide, et de ses principaux métabolites, y compris les glucuronides. Au cours de ces dix dernières années, un nombre significatif de publications sont parues sur ce sujet. L'objectif de cet article est de passer en revue les analyses par spectrométrie de masse en tandem des cannabinoïdes dans diverses matrices biologiques. In recent years, tandem mass spectrometry (MS/MS) is gaining ground as a reference method of analysis in clinical and forensic toxicology, especially for the determination of cannabinoids. Coupled to liquid chromatography (LC) or gas chromatography (GC), it allows the definitive identification and rapid determination of THC, its acid precursor, and its major metabolites, including the glucuronides. During the past decade, several methods of analysis of cannabinoids in different matrices have appeared on this subject. The aim of this paper is to review the analysis of cannabinoids by tandem mass spectrometry methods in various biological matrices

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An HPLC-PAD method using a gold working electrode and a triple-potential waveform was developed for the simultaneous determination of streptomycin and dihydrostreptomycin in veterinary drugs. Glucose was used as the internal standard, and the triple-potential waveform was optimized using a factorial and a central composite design. The optimum potentials were as follows: amperometric detection, E1=-0.15V; cleaning potential, E2=+0.85V; and reactivation of the electrode surface, E3=-0.65V. For the separation of the aminoglycosides and the internal standard of glucose, a CarboPac™ PA1 anion exchange column was used together with a mobile phase consisting of a 0.070 mol L(-1) sodium hydroxide solution in the isocratic elution mode with a flow rate of 0.8 mL min(-1). The method was validated and applied to the determination of streptomycin and dihydrostreptomycin in veterinary formulations (injection, suspension and ointment) without any previous sample pretreatment, except for the ointments, for which a liquid-liquid extraction was required before HPLC-PAD analysis. The method showed adequate selectivity, with an accuracy of 98-107% and a precision of less than 3.9%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The controlled disposal of tannery sludge in agricultural soils is a viable alternative for recycling such waste; however, the impact of this practice on the arbuscular mycorrhizal fungi (AMF) communities is not well understood. We studied the effects of low-chromium tannery sludge amendment in soils on AMF spore density, species richness and diversity, and root colonization levels. Sludge was applied at four doses to an agricultural field in Rolandia, Parana state, Brazil. The sludge was left undisturbed on the soil surface and then the area was harrowed and planted with corn. The soil was sampled at four intervals and corn roots once within a year (2007/2008). AMF spore density was low (1 to 49 spores per 50 cm(3) of soil) and decreased as doses of tannery sludge increased. AMF root colonization was high (64%) and unaffected by tannery sludge. Eighteen AMF species belonging to six genera (Acaulospora, Glomus, Gigaspora, Scutellospora, Paraglomus, and Ambispora) were recorded. At the sludge doses of 9.0 and 22.6 Mg ha(-1), we observed a decrease in AMF species richness and diversity, and changes in their relative frequencies. Hierarchical grouping analysis showed that adding tannery waste to the soil altered AMF spore community in relation to the control, modifying the mycorrhizal status of soil and selectively favoring the sporulation of certain species.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared an enzyme-linked immunosorbent assay (ELISA) to a liquid chromatography-tandem mass spectrometry (LC/MS/MS) technique for measurement of tacrolimus concentrations in adult kidney and liver transplant recipients, and investigated how assay choice influenced pharmacokinetic parameter estimates and drug dosage decisions. Tacrolimus concentrations measured by both ELISA and LC/MS/MS from 29 kidney (n = 98 samples) and 27 liver (n = 97 samples) transplant recipients were used to evaluate the performance of these methods in the clinical setting. Tacrolimus concentrations measured by the two techniques were compared via regression analysis. Population pharmacokinetic models were developed independently using ELISA and LC/MS/MS data from 76 kidney recipients. Derived kinetic parameters were used to formulate typical dosing regimens for concentration targeting. Dosage recommendations for the two assays were compared. The relation between LC/MS/MS and ELISA measurements was best described by the regression equation ELISA = 1.02 . (LC/MS/MS) + 0.14 in kidney recipients, and ELISA = 1.12 . (LC/MS/MS) - 0.87 in liver recipients. ELISA displayed less accuracy than LC/MS/MS at lower tacrolimus concentrations. Population pharmacokinetic models based on ELISA and LC/MS/MS data were similar with residual random errors of 4.1 ng/mL and 3.7 ng/mL, respectively. Assay choice gave rise to dosage prediction differences ranging from 0% to 30%. ELISA measurements of tacrolimus are not automatically interchangeable with LC/MS/MS values. Assay differences were greatest in adult liver recipients, probably reflecting periods of liver dysfunction and impaired biliary secretion of metabolites. While the majority of data collected in this study suggested assay differences in adult kidney recipients were minimal, findings of ELISA dosage underpredictions of up to 25% in the long term must be investigated further.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A square-wave voltammetric (SWV) method and a flow injection analysis system with amperometric detection were developed for the determination of tramadol hydrochloride. The SWV method enables the determination of tramadol over the concentration range of 15-75 µM with a detection limit of 2.2 µM. Tramadol could be determined in concentrations between 9 and 50 µM at a sampling rate of 90 h-1, with a detection limit of 1.7 µM using the flow injection system. The electrochemical methods developed were successfully applied to the determination of tramadol in pharmaceutical dosage forms, without any pre-treatment of the samples. Recovery trials were performed to assess the accuracy of the results; the values were between 97 and 102% for both methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The reduction of luvastatin (FLV) at a hanging mercury-drop electrode (HMDE) was studied by square-wave adsorptive-stripping voltammetry (SWAdSV). FLV can be accumulated and reduced at the electrode, with a maximum peak current intensity at a potential of approximately 1.26V vs. AgCl=Ag, in an aqueous electrolyte solution of pH 5.25. The method shows linearity between peak current intensity and FLV concentration between 1.0 10 8 and 2.7 10 6 mol L 1. Limits of detection (LOD) and quantification (LOQ) were found to be 9.9 10 9 mol L 1 and 3.3 10 8 mol L 1, respectively. Furthermore, FLV oxidation at a glassy carbon electrode surface was used for its hydrodynamic monitoring by amperometric detection in a flow-injection system. The amperometric signal was linear with FLV concentration over the range 1.0 10 6 to 1.0 10 5 mol L 1, with an LOD of 2.4 10 7 mol L 1 and an LOQ of 8.0 10 7 mol L 1. A sample rate of 50 injections per hour was achieved. Both methods were validated and showed to be precise and accurate, being satisfactorily applied to the determination of FLV in a commercial pharmaceutical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although past reviews uniformly criticized the efficacy and effectiveness of sexual abstinence in adolescents, new studies dispute the earlier findings. Studies that unpackage intervention programs provide one means of understanding why they succeed in some settings and not in others. This study examined 3183 students spread over 35 schools on the number of hours that they received in sexual abstinence education, in a context of health behaviors promotion. A multi-level analysis (HLM) was performed. The number of hours did not appear to make any difference in the outcome scores. Reasons for this finding are presented and their implications are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Retrospective analyses suggest that personalized PK-based dosage might be useful for imatinib, as treatment response correlates with trough concentrations (Cmin) in cancer patients. Our objectives were to improve the interpretation of randomly measured concentrations and to confirm its efficiency before evaluating the clinical usefulness of systematic PK-based dosage in chronic myeloid leukemia patients. Methods and Results: A Bayesian method was validated for the prediction of individual Cmin on the basis of a single random observation, and was applied in a prospective multicenter randomized controlled clinical trial. 28 out of 56 patients were enrolled in the systematic dosage individualization arm and had 44 follow-up visits (their clinical follow-up is ongoing). PK-dose-adjustments were proposed in 39% having predicted Cmin significantly away from the target (1000 ng/ml). Recommendations were taken up by physicians in 57%, patients were considered non-compliant in 27%. Median Cmin at study inclusion was 754 ng/ml and differed significantly from the target (p=0.02, Wilcoxon test). On follow-up, Cmin was 984 ng/ml (p=0.82) in the compliant group. CV decreased from 46% to 27% (p=0.02, F-test). Conclusion: PK-based (Bayesian) dosage adjustment is able to bring individual drug exposure closer to a given therapeutic target. Its influence on therapeutic response remains to be evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Although the maximal quetiapine doses in the published studies were restricted to 800 mg/day, higher quetiapine doses are not unusual in clinical practice. The aim of the present study was to evaluate the effectiveness, tolerability and clinical reasons associated to the use of high dosage of quetiapine (>800 mg), when used under routine clinical conditions, in a sample of bipolar disorder and schizoaffective bipolar inpatients. METHODS: Charts of all bipolar and schizoaffective adult inpatients, who had received quetiapine for a mood episode between 1999 and 2005 were retrospectively reviewed. These charts also included the assessment of manic and depressive symptoms on admission and at discharge using the Beck-Rafaelsen Mania Scale (MAS) and the Montgomery Asberg depression rating scale (MADRS), respectively. RESULTS: Data of 50 patients were analyzed. The overall F in repeated measures ANOVA revealed a significant MAS scores reduction between admission and discharge. MAS scores reduction did not differ between the high and low quetiapine groups. Similarly, a significant MADRS reduction was found. Again, no differences between the high and the low dose group were found. Logistic regression analysis of the 50 patients revealed only mixed episodes predicted high quetiapine dosage. CONCLUSIONS: The present study confirms quetiapine efficiency and tolerability in the treatment of bipolar episodes, even in doses > to 800 mg and found a link between quetiapine doses and mixed episodes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: It is suggested that a low dose of valganciclovir can be equally effective than a standard dose for cytomegalovirus (CMV) prophylaxis after kidney transplantation. The aim of our study was to determine the ganciclovir exposure observed under a routine daily dosage of 450 mg valganciclovir in kidney transplant recipients with a wide range of renal function. Methods: In this prospective study, kidney transplant recipients with a GFR MDRD above 25 mL/min at risk for CMV (donor or recipient seropositive for CMV) received a dose of valganciclovir (450 mg daily) prophylaxis for 3 months. Ganciclovir levels at trough (Ctrough) and at peak (C3h) were measured monthly. Ganciclovir exposure (AUC0-24) was estimated using Bayesian non-linear mixed-effect modelling (NONMEM) and compared between 3 groups of patients according to their kidney function: GFRMDRD 26-39 mL/min (Group 1), GFRMDRD 40-59 mL/min (Group 2) and GFRMDRD 60-90 mL/min (Group 3). CMV DNAemia was assessed during and after prophylaxis using PCR. Results: Thirty-six patients received 450 mg daily of valganciclovir for 3 months. Median ganciclovir C3h was 3.9 mg/L (range: 1.3-7.1) and Ctrough was 0.4 mg/L (range 0.1-2.7). Median (range) AUC0-24 of ganciclovir was 59.3 mg.h/L (39.0-85.3) in Group 1 patients, 35.8 mg.h/L (24.9-55.8) in Group 2 patients and 29.6 mg.h/L (22.0- 43.2) in Group 3 patients (p<0.001). Anemia was more common in Group 1 patients compared to patients on the other groups (p=0.01). No differences in other adverse events according to ganciclovir exposure were observed. CMV DNAemia was not detected during prophylaxis. After discontinuing prophylaxis, CMV DNAemia was seen in 8/34 patients (23.5%) and 4/36 patients (11%) developed CMV disease. Conclusion: A routine dosage of valganciclovir achieved plasma levels of ganciclovir in patients with GFR>60 mL/min similar to those previously reported using oral ganciclovir. A daily dose of 450 mg valganciclovir appears to be acceptable for CMV prophylaxis in most kidney transplant recipients.