897 resultados para doping profiles


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Includes bibliographical references.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This Master’s Thesis is dedicated to the simulation of new p-type pixel strip detector with enhanced multiplication effect. It is done for high-energy physics experiments upgrade such as Super Large Hadron Collider especially for Compact Muon Solenoid particle track silicon detectors. These detectors are used in very harsh radiation environment and should have good radiation hardness. The device engineering technology for developing more radiation hard particle detectors is used for minimizing the radiation degradation. New detector structure with enhanced multiplication effect is proposed in this work. There are studies of electric field and electric charge distribution of conventional and new p-type detector under reverse voltage bias and irradiation. Finally, the dependence of the anode current from the applied cathode reverse voltage bias under irradiation is obtained in this Thesis. For simulation Silvaco Technology Computer Aided Design software was used. Athena was used for creation of doping profiles and device structures and Atlas was used for getting electrical characteristics of the studied devices. The program codes for this software are represented in Appendixes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An analysis of the active pixel sensor (APS), considering the doping profiles of the photodiode in an APS fabricated in a 0.18 μm standard CMOS technology, is presented. A simple and accurate model for the junction capacitance of the photodiode is proposed. An analytic expression for the output voltage of the APS obtained with this capacitance model is in good agreement with measurements and is more accurate than the models used previously. A different mode of operation for the APS based on the dc level of the output is suggested. This new mode has better low-light-level sensitivity than the conventional APS operating mode, and it has a slower temporal response to the change of the incident light power. At 1μW/cm2 and lower levels of light, the measured signal-to-noise ratio (SNR) of this new mode is more than 10 dB higher than the SNR of previously reported APS circuits. Also, with an output SNR of about 10 dB, the proposed dc level is capable of detecting light powers as low as 20 nW/cm2, which is about 30 times lower than the light power detected in recent reports by other groups. © 2007 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Due to their performance enhancing properties, use of anabolic steroids (e.g. testosterone, nandrolone, etc.) is banned in elite sports. Therefore, doping control laboratories accredited by the World Anti-Doping Agency (WADA) screen among others for these prohibited substances in urine. It is particularly challenging to detect misuse with naturally occurring anabolic steroids such as testosterone (T), which is a popular ergogenic agent in sports and society. To screen for misuse with these compounds, drug testing laboratories monitor the urinary concentrations of endogenous steroid metabolites and their ratios, which constitute the steroid profile and compare them with reference ranges to detect unnaturally high values. However, the interpretation of the steroid profile is difficult due to large inter-individual variances, various confounding factors and different endogenous steroids marketed that influence the steroid profile in various ways. A support vector machine (SVM) algorithm was developed to statistically evaluate urinary steroid profiles composed of an extended range of steroid profile metabolites. This model makes the interpretation of the analytical data in the quest for deviating steroid profiles feasible and shows its versatility towards different kinds of misused endogenous steroids. The SVM model outperforms the current biomarkers with respect to detection sensitivity and accuracy, particularly when it is coupled to individual data as stored in the Athlete Biological Passport.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Résumé : Erythropoietin (EPO) is a glycoprotein hormone endogenously produced by the kidney, whose main physiological role is the stimulation of erythropoiesis. Since the beginning of the nineties, recombinant human EPO (rhEPO), a potent anti-anaemia treatment drug, has been manufactured by pharmaceutical industries. However, the erythropoiesis stimulating power of rhEPO was rapidly misused by unscrupulous athletes in order to improve their performances in endurance sports. Endogenous EPO has the same amino-acid backbone as most of recombinant forms; the molecules however differ through their respective glycosylation patterns. This difference constitutes the basis of the usual EPO screening test (IEF) developed in 2000 and still currently used in all anti-doping laboratories of the world. Nowadays, 3 EPO generations have been commercialized. The fight against EPO abuse is a continuous challenge for anti-doping laboratories. The diversity of recombinant EPO forms and the continuous development of new ones considerably confuse the identification of EPO doping. Several facets of this fight were investigated in this work. One of the limiting aspects of doping agents screening is the availability of positive samples. Therefore, 2nd and 3rd generation EPOS, namely NESP and C.E.R.A., were injected to healthy subjects in the frame of pilot clinical studies. These latter allowed to review the current EPO identification criteria defined by the World Anti-Doping Agency (WADA) in the case of NESP and to validate and implement a new assay targeting C.E.R.A. in human serum. Both studies resulted in the determination of the respective detection windows of NESP and C.E.R.A. in biological fluids. Following that, Dynepo, a 1st generation EPO presenting similarities with the endogenous form, was also in the centre of a similar clinical study. Our work aimed to overcome the actual identification criteria, which are not adapted to Dynpeo, and to propose an alternative pattern classification method based on the discriminant analysis of IEF EPO profiles. This method might be validated for other EPO forms in the future. The detection window of this molecule was also determined. Under particular conditions, confounding effects can complicate the identification of EPO in biological matrices. For example, athletes having performed a strenuous physical effort can excrete modified isoforms of endogenous EPO, making it very similar to some recombinant forms. Such phenomena, called effort urines, were reproduced under controlled conditions and, after characterization of effort EPO, an urinary biochemical marker was proposed to unequivocally identify effort urines. It also happens that EPO analyses fail to detect endogenous levels of EPO. Such profiles were thoroughly investigated and potential causes identified. Natural reasons relying on urine properties and test specificity were underlined, but the possible addition of adulterant agents in urine samples was also considered. Therefore, a simple biochemical assay targeting the suspected substances was set up. Our work was based on the characterization of atypical EPO profiles from different origins. Therefore, 3 EPO molecules representing the 3 generations of the drug and 2 confounding effects confusing the results interpretation were studied. These studies resulted in tangible applications for the laboratory, the best example of which being the C.E.R.A. assay, but also in scientific findings allowing to improve our comprehension of EPO doping in sport.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE AND METHOD: To outline the direct and indirect approaches in the fight against blood doping in sports, the different strategies that have been used and are currently being used to fight efficiently against blood doping are presented and discussed. RESULTS AND CONCLUSIONS: The paper outlines the different approaches and diagnostic tools that some federations have to identify and target sports people demonstrating abnormal blood profiles. Originally blood tests were introduced for medical reasons and for limiting misuse of recombinant human erythropoietin (rHuEPO). In this way it became possible to prevent athletes with haematocrit levels well above normal, and potentially dangerous for their health, competing in sport. Today, with nearly a decade of blood testing experience, sports authorities should be familiar with some of the limitations and specially the ability of blood tests performed prior to competitions to fight efficiently against the misuse of rHuEPO, blood transfusion, and artificial haemoglobin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Since 2004, cannabis has been prohibited by the World Anti-Doping Agency for all sports competitions. In the years since then, about half of all positive doping cases in Switzerland have been related to cannabis consumption. In doping urine analysis, the target analyte is 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THC-COOH), the cutoff being 15 ng/mL. However, the wide urinary detection window of the long-term metabolite of Delta(9)-tetrahydrocannabinol (THC) does not allow a conclusion to be drawn regarding the time of consumption or the impact on the physical performance. The purpose of the present study on light cannabis smokers was to evaluate target analytes with shorter urinary excretion times. Twelve male volunteers smoked a cannabis cigarette standardized to 70 mg THC per cigarette. Plasma and urine were collected up to 8 h and 11 days, respectively. Total THC, 11-hydroxy-Delta(9)-tetrahydrocannabinol (THC-OH), and THC-COOH were determined after hydrolysis followed by solid-phase extraction and gas chromatography/mass spectrometry. The limits of quantitation were 0.1-1.0 ng/mL. Eight puffs delivered a mean THC dose of 45 mg. Plasma levels of total THC, THC-OH, and THC-COOH were measured in the ranges 0.2-59.1, 0.1-3.9, and 0.4-16.4 ng/mL, respectively. Peak concentrations were observed at 5, 5-20, and 20-180 min. Urine levels were measured in the ranges 0.1-1.3, 0.1-14.4, and 0.5-38.2 ng/mL, peaking at 2, 2, and 6-24 h, respectively. The times of the last detectable levels were 2-8, 6-96, and 48-120 h. Besides high to very high THC-COOH levels (245 +/- 1,111 ng/mL), THC (3 +/- 8 ng/mL) and THC-OH (51 +/- 246 ng/mL) were found in 65 and 98% of cannabis-positive athletes' urine samples, respectively. In conclusion, in addition to THC-COOH, the pharmacologically active THC and THC-OH should be used as target analytes for doping urine analysis. In the case of light cannabis use, this may allow the estimation of more recent consumption, probably influencing performance during competitions. However, it is not possible to discriminate the intention of cannabis use, i.e., for recreational or doping purposes. Additionally, pharmacokinetic data of female volunteers are needed to interpret cannabis-positive doping cases of female athletes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Urinary steroid profiling is used in doping controls to detect testosterone abuse. A testosterone over epitestosterone (T/E) ratio exceeding 4.0 is considered as suspicious of testosterone administration, irrespectively of individual heterogeneous factors such as the athlete's ethnicity. A deletion polymorphism in the UGT2B17 gene was demonstrated to account for a significant part of the interindividual variability in the T/E between Caucasians and Asians. Here, the variability of urinary steroid profiles was examined in a widely heterogeneous cohort of professional soccer players. Method: The steroid profile of 57 Africans, 32 Asians, 50 Caucasians and 32 Hispanics was determined by gas chromatography-mass spectrometry. RESULTS: Significant differences have been observed between all ethnic groups. After estimation of the prevalence of the UGT2B17 deletion/deletion genotype (African: 22%; Asian: 81%; Caucasian: 10%; Hispanic: 7%), ethnic-specific thresholds were developed for a specificity of 99% for the T/E (African: 5.6; Asian: 3.8; Caucasian: 5.7; Hispanic: 5.8). Finally, another polymorphism could be hypothesised in Asians based on specific concentration ratio of 5alpha-/5beta-androstane-3alpha,17beta-diol in urine. CONCLUSION: These results demonstrate that a unique and non-specific threshold to evidence testosterone misuse is not fit for purpose. An athlete's endocrinological passport consisting of a longitudinal follow-up together with the ethnicity and/or the genotype would strongly enhance the detection of testosterone abuse. Finally, additional genotyping studies should be undertaken to determine whether the remaining unexplained disparities have an environmental or a genetic origin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Blood doping (BD) is the use of Erythropoietic Stimulating Agents (ESAs) and/or transfusion to increase aerobic performance in athletes. Direct toxicologic techniques are insufficient to unmask sophisticated doping protocols. The Hematological module of the ABP (World Anti-Doping Agency), associates decision support technology and expert assessment to indirectly detect BD hematological effects. Methods: The ABP module is based on blood parameters, under strict pre-analytical and analytical rules for collection, storage and transport at 2-12°C, internal and external QC. Accuracy, reproducibility and interlaboratory harmonization fulfill forensic standard. Blood samples are collected in competition and out-ofcompetition. Primary parameters for longitudinal monitoring are: - hemoglobin (HGB); - reticulocyte percentage (RET); - OFF score, indicator of suppressed erythropoiesis, calculated as [HGB(g/L) * 60-√RET%]. Statistical calculation predicts individual expected limits by probabilistic inference. Secondary parameters are RBC, HCT, MCHC-MCH-MCV-RDW-IFR. ABP profiles flagged as atypical are review by experts in hematology, pharmacology, sports medicine or physiology, and classified as: - normal - suspect (to target) - likely due to BD - likely due to pathology. Results: Thousands of athletes worldwide are currently monitored. Since 2010, at least 35 athletes have been sanctioned and others are prosecuted on the sole basis of abnormal ABP, with a 240% increase of positivity to direct tests for ESA, thanks to improved targeting of suspicious athletes (WADA data). Specific doping scenarios have been identified by the Experts (Table and Figure). Figure. Typical HGB and RET profiles in two highly suspicious athletes. A. Sample 2: simultaneous increases in HGB and RET (likely ESA stimulation) in a male. B. Samples 3, 6 and 7: "OFF" picture, with high HGB and low RET in a female. Sample 10: normal HGB and increased RET (ESA or blood withdrawal). Conclusions: ABP is a powerful tool for indirect doping detection, based on the recognition of specific, unphysiological changes triggered by blood doping. The effect of factors of heterogeneity, such as sex and altitude, must also be considered. Schumacher YO, et al. Drug Test Anal 2012, 4:846-853. Sottas PE, et al. Clin Chem 2011, 57:969-976.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fight against doping is mainly focused on direct detection, using analytical methods for the detection of doping agents in biological samples. However, the World Anti-Doping Code also defines doping as possession, administration or attempted administration of prohibited substances or methods, trafficking or attempted trafficking in any prohibited substance or methods. As these issues correspond to criminal investigation, a forensic approach can help assessing potential violation of these rules.In the context of a rowing competition, genetic analyses were conducted on biological samples collected in infusion apparatus, bags and tubing in order to obtain DNA profiles. As no database of athletes' DNA profiles was available, the use of information from the location detection as well as contextual information were key to determine a population of suspected athletes and to obtain reference DNA profiles for comparison.Analysis of samples from infusion systems provided 8 different DNA profiles. The comparison between these profiles and 8 reference profiles from suspected athletes could not be distinguished.This case-study is one of the first where a forensic approach was applied for anti-doping purposes. Based on this investigation, the International Rowing Federation authorities decided to ban not only the incriminated athletes, but also the coaches and officials for 2 years.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The fight against doping is mainly focused on direct detection, using analytical methods for the detection of doping agents in biological samples. However, the World Anti-Doping Code also defines doping as possession, administration or attempted administration of prohibited substances or methods, trafficking or attempted trafficking in any prohibited substance or methods. As these issues correspond to criminal investigation, a forensic approach can help assessing potential violation of these rules. In the context of a rowing competition, genetic analyses were conducted on biological samples collected in infusion apparatus, bags and tubing in order to obtain DNA profiles. As no database of athletes' DNA profiles was available, the use of information from the location detection as well as contextual information were key to determine a population of suspected athletes and to obtain reference DNA profiles for comparison. Analysis of samples from infusion systems provided 8 different DNA profiles. The comparison between these profiles and 8 reference profiles from suspected athletes could not be distinguished. This case-study is one of the first where a forensic approach was applied for anti-doping purposes. Based on this investigation, the International Rowing Federation authorities decided to ban not only the incriminated athletes, but also the coaches and officials for 2 years.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Anabolic steroids are synthetic derivatives of testosterone, modified to enhance its anabolic actions (promotion of protein synthesis and muscle growth). They have numerous side effects, and are on the International Olympic Committee's list of banned substances. Gas chromatography-mass spectrometry allows identification and characterisation of steroids and their metabolites in the urine but may not distinguish between pharmaceutical and natural testosterone. Indirect methods to detect doping include determination of the testosterone/epitestosterone glucuronide ratio with suitable cut-off values. Direct evidence may be obtained with a method based on the determination of the carbon isotope ratio of the urinary steroids. This paper aims to give an overview of the use of anabolic-androgenic steroids in sport and methods used in anti-doping laboratories for their detection in urine, with special emphasis on doping with testosterone. METHODS: Review of the recent literature of anabolic steroid testing, athletic use, and adverse effects of anabolic-androgenic steroids. RESULTS: Procedures used for detection of doping with endogenous steroids are outlined. The World Anti-Doping Agency provided a guide in August 2004 to ensure that laboratories can report, in a uniform way, the presence of abnormal profiles of urinary steroids resulting from the administration of testosterone or its precursors, androstenediol, androstenedione, dehydroepiandrosterone or a testosterone metabolite, dihydrotestosterone, or a masking agent, epitestosterone. CONCLUSIONS: Technology developed for detection of testosterone in urine samples appears suitable when the substance has been administered intramuscularly. Oral administration leads to rapid pharmacokinetics, so urine samples need to be collected in the initial hours after intake. Thus there is a need to find specific biomarkers in urine or plasma to enable detection of long term oral administration of testosterone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MicroRNAs (miRNAs) are small non-coding RNAs that regulate a variety of biological processes. Cell-free miRNAs detected in blood plasma are used as specific and sensitive markers of physiological processes and some diseases. Circulating miRNAs are highly stable in body fluids, for example plasma. Therefore, profiles of circulating miRNAs have been investigated for potential use as novel, non-invasive anti-doping biomarkers. This review describes the biological mechanisms underlying the variation of circulating miRNAs, revealing that they have great potential as a new class of biomarker for detection of doping substances. The latest developments in extraction and profiling technology, and the technical design of experiments useful for anti-doping, are also discussed. Longitudinal measurements of circulating miRNAs in the context of the athlete biological passport are proposed as an efficient strategy for the use of these new markers. The review also emphasizes potential challenges for the translation of circulating miRNAs from research into practical anti-doping applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Urine is still the matrix of choice to fight against doping, because it can be collected non-invasively during anti-doping tests. Most of the World Anti-Doping Agency's accredited laboratories have more than 20 years experience in analyzing this biological fluid and the majority of the compounds listed in the 2010 Prohibited List - International Standard are eliminated through the urinary apparatus. Storing and transporting urine samples for doping analyses does not include a specific protocol to prevent microbial and thermal degradation. The use of a rapid and reliable screening method could enable determine reference intervals for urine specimens in doping control samples and evaluate notably the prevalence of microbial contamination known to be responsible for the degradation of chemical substances in urine.Methods: The Sysmex(R) UF-500i is a recent urine flow cytometer analyzer capable of quantifying BACT and other urinary particles such as RBC, WBC, EC, DEBRIS, CAST, PATH. CAST, YLC, SRC as well as measuring urine conductivity. To determine urine anti-doping reference intervals, 501 samples received in our laboratory over a period of two months were submitted to an immediate examination. All samples were collected and then transported at room temperature. Analysis of variance was performed to test the effects of factors such as gender, test type [in-competition, out-of-competition] and delivery time.Results: The data obtained showed that most of the urine samples were highly contaminated with bacteria. The other urine particles were also very different according to the factors.Conclusions: The Sysmex(R) UF-500i was capable of providing a snapshot of urine particles present in the samples at the time of the delivery to the laboratory. These particles, BACT in particular, gave a good idea of the possible microbial degradation which had and/or could have occurred in the sample. This information could be used as the first quality control set up in WADA (World Anti-Doping Agency) accredited laboratories to determine if steroid profiles, endogenous and prohibited substances have possibly been altered. (C) 2011 Elsevier Ireland Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

microRNAs (miRNAs) are small non-coding RNAs that regulate various biological processes. Cell-free miRNAs have been proposed as biomarkers of disease, including diagnosis, prognosis, and monitoring of treatment responses. These circulating miRNAs are highly stable in several body fluids, including plasma and serum; hence, in view of their potential use as novel, non-invasive biomarkers, the profiles of circulating miRNAs have been explored in the field of anti-doping. This chapter describes the enormous potential of circulating miRNAs as a new class of biomarkers for the detection of doping substances, and highlights the advantages of measuring these stable species over other methods that have already been implemented in anti-doping regimes. Incorporating longitudinal measurements of circulating miRNAs into the Athlete Biological Passport is proposed as an efficient strategy for the implementation of these new biomarkers. Furthermore, potential challenges related to the transition of measurements of circulating miRNAs from research settings to practical anti-doping applications are presented.