770 resultados para dispersive liquid-liquid microextraction
Resumo:
Solid-phase extraction (SPE) in tandem with dispersive liquid-liquid microextraction (DLLME) has been developed for the determination of mononitrotoluenes (MNTs) in several aquatic samples using gas chromatography-flame ionization (GC-FID) detection system. In the hyphenated SPE-DLLME, initially MNTs were extracted from a large volume of aqueous samples (100 mL) into a 500-mg octadecyl silane (C(18) ) sorbent. After the elution of analytes from the sorbent with acetonitrile, the obtained solution was put under the DLLME procedure, so that the extra preconcentration factors could be achieved. The parameters influencing the extraction efficiency such as breakthrough volume, type and volume of the elution solvent (disperser solvent) and extracting solvent, as well as the salt addition, were studied and optimized. The calibration curves were linear in the range of 0.5-500 μg/L and the limit of detection for all analytes was found to be 0.2 μg/L. The relative standard deviations (for 0.75 μg/L of MNTs) without internal standard varied from 2.0 to 6.4% (n=5). The relative recoveries of the well, river and sea water samples, spiked at the concentration level of 0.75 μg/L of the analytes, were in the range of 85-118%.
Resumo:
A simple ion pair-dispersive liquid-liquid microextraction method was proposed for preconcentration trace amounts of rhodium. An ion association complex of RhCl4- and tetradecyldimetylbenzylamonium was extracted into cholorobenzene. The volume and the type of extractive and dispersive solvents, the extraction time and the pH of the aqueous solutions were optimized. The calibration curve was linear in the range of 0.6-500 ng mL-1 of rhodium. The limit of detection was 0.10 ng mL-1 in initial solution and preconcentration factor was 40. The proposed method was successfully applied to the extraction and determination of rhodium in road dust and water samples.
Resumo:
In the proposed method, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, such as extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, linearity was maintained between 1.0 ng mL-1 to 1.5 mg mL-1 for zinc and 1.0 ng mL-1 to 0.4 mg mL-1 for cadmium. The proposed method has been applied for determination of trace amount of zinc and cadmium in standard and water samples with satisfactory results.
Resumo:
A dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous extraction of trace amounts of nickel, cobalt and copper followed by their determination with electrothermal atomic absorption spectrometry was developed. 300 µL of acetone and 1-undecanol was injected into an aqueous sample containing diethyldithiocarbamate complexes of metal ions. For a sample volume of 10 mL, enrichment factors of 277, 270 and 300 and detection limits of 1.2, 1.1 and 1 ng L-1 for nickel, cobalt and copper were obtained, respectively. The method was applied to the extraction and determination of these metals in different water samples.
Resumo:
A dispersive liquid-liquid microextraction procedure coupled to spectrophotometry is described for the determination of the trace levels of Sudan Blue II. Analytical parameters, such as pH, volume of extraction solvent (carbon tetrachloride), volume of dispersant (ethanol), volume of sample, and extraction time, were optimized. Matrix effects were also investigated. Preconcentration factor was found to be 200. Detection limit and relative standard deviation (RSD) were 0.55 µg L-1 and 3.9%, respectively. The procedure was successfully used for the determination of trace levels of Sudan Blue II in food, ink, antifreeze, and industrial waste-water samples.
Resumo:
In this study, dispersive liquid-liquid microextraction based on the solidification of floating organic droplets was used for the preconcentration and determination of thorium in the water samples. In this method, acetone and 1-undecanol were used as disperser and extraction solvents, respectively, and the ligand 1-(2-thenoyl)-3,3,3-trifluoracetone reagent (TTA) and Aliquat 336 was used as a chelating agent and an ion-paring reagent, for the extraction of thorium, respectively. Inductively coupled plasma-optical emission spectrometry was applied for the quantitation of the analyte after preconcentration. The effect of various factors, such as the extraction and disperser solvent, sample pH, concentration of TTA and concentration of aliquat336 were investigated. Under the optimum conditions, the calibration graph was linear within the thorium content range of 1.0-250 µg L-1 with a detection limit of 0.2 µg L-1. The method was also successfully applied for the determination of thorium in the different water samples.
Resumo:
A novel, simple, rapid and eco-friendly method based on dispersive liquid-liquid microextraction using a bromosolvent was developed to determine six estrogenic mycotoxins (zearalenone, zearalanone, alpha-zearalanol, beta-zearalanol, alpha-zearalenol and beta-zearalenol) in water samples by liquid chromatography-electrospray ionization tandem mass spectrometry in the negative mode (LC-ESI-MS/MS). The optimal conditions for this method include the use of 100 mu L bromocyclohexane as an extraction solvent (using a non-dispersion solvent), 10 mL of aqueous sample (adjusted to pH 4), a vortex extraction time of 2 min, centrifugation for 10 min at 3500 rpm and no ionic strength adjustment. The calibration function was linear and was verified by applying the Mandel fitting test with a 95% confidence level. No matrix effect was observed. According to the relative standard deviations (RSDs), the precision was better than 13% for the repeatability and intermediate precision. The average recoveries of the spiked compounds ranged from 81 to 118%. The method limits of detection (LOD) and quantification (LOQ) considering a 125-fold pre-concentration step were 4-20 and 8-40 ng L-1, respectively. Next, the method was applied to the analysis of the environmental aqueous samples, demonstrating the presence of beta-zearalanol and zearalanone in the river water samples. (C) 2015 Elsevier B.V. All rights reserved.
Resumo:
A fast, simple and environmentally friendly ultrasound-assisted dispersive liquid-liquid microextraction (USA-DLLME) procedure has been developed to preconcentrate eight cyclic and linear siloxanes from wastewater samples prior to quantification by gas chromatography-mass spectrometry (GC-MS). A two-stage multivariate optimization approach has been developed employing a Plackett-Burman design for screening and selecting the significant factors involved in the USA-DLLME procedure, which was later optimized by means of a circumscribed central composite design. The optimum conditions were: extractant solvent volume, 13 µL; solvent type, chlorobenzene; sample volume, 13 mL; centrifugation speed, 2300 rpm; centrifugation time, 5 min; and sonication time, 2 min. Under the optimized experimental conditions the method gave levels of repeatability with coefficients of variation between 10 and 24% (n=7). Limits of detection were between 0.002 and 1.4 µg L−1. Calculated calibration curves gave high levels of linearity with correlation coefficient values between 0.991 and 0.9997. Finally, the proposed method was applied for the analysis of wastewater samples. Relative recovery values ranged between 71–116% showing that the matrix had a negligible effect upon extraction. To our knowledge, this is the first time that combines LLME and GC-MS for the analysis of methylsiloxanes in wastewater samples.
Resumo:
Liquid-liquid microextraction without phase segmentation was implemented in a multicommuted flow system for determination of the anti-hypertensive diltiazem. The procedure was based on ion pair formation between the drug and the dye bromothymol blue at pH 3.5. The detection was performed without phase separation in a glass tube coupled to a fiber-optics spectrophotometer. The total volume of chloroform was reduced to 50 mu L in comparison with 10 mL consumed in batch. A linear response was observed between 9 and 120 mu mol L(-1), with a detection limit of 0.9 mu mol L(-1) (99.7% confidence level). The coefficient of variation (n = 10), sampling rate and extraction efficiency were estimated as 0.6%, 78 determinations per hour and 61%, respectively. About 30 mu g of bromothymol blue was consumed and the waste volume was 380 mu L per determination. The results for pharmaceutical samples agreed with those obtained by the reference procedure at the 95% confidence level. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
A method for the determination of trace amounts of palladium was developed using homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA) followed by graphite furnace atomic absorption spectrometry (GFAAS). Ammonium pyrrolidine dithiocarbamate (APDC) was used as a complexing agent. This was applied to determine palladium in three types of water samples. In this study, a special extraction cell was designed to facilitate collection of the low-density solvent extraction. No centrifugation was required in this procedure. The water sample solution was added to the extraction cell which contained an appropriate mixture of extraction and homogeneous solvents. By using air flotation, the organic solvent was collected at the conical part of the designed cell. Parameters affecting extraction efficiency were investigated and optimized. Under the optimum conditions, the calibration graph was linear in the range of 1.0-200 µg L-1 with a limit of detection of 0.3 µg L-1. The performance of the method was evaluated for the extraction and determination of palladium in water samples and satisfactory results were obtained. In order to verify the accuracy of the approach, the standard addition method was applied for the determination of palladium in spiked synthetic samples and satisfactory results were obtained.
Resumo:
A novel method is reported, whereby screen-printed electrodes (SPELs) are combined with dispersive liquid–liquid microextraction. In-situ ionic liquid (IL) formation was used as an extractant phase in the microextraction technique and proved to be a simple, fast and inexpensive analytical method. This approach uses miniaturized systems both in sample preparation and in the detection stage, helping to develop environmentally friendly analytical methods and portable devices to enable rapid and onsite measurement. The microextraction method is based on a simple metathesis reaction, in which a water-immiscible IL (1-hexyl-3-methylimidazolium bis[(trifluoromethyl)sulfonyl]imide, [Hmim][NTf2]) is formed from a water-miscible IL (1-hexyl-3-methylimidazolium chloride, [Hmim][Cl]) and an ion-exchange reagent (lithium bis[(trifluoromethyl)sulfonyl]imide, LiNTf2) in sample solutions. The explosive 2,4,6-trinitrotoluene (TNT) was used as a model analyte to develop the method. The electrochemical behavior of TNT in [Hmim][NTf2] has been studied in SPELs. The extraction method was first optimized by use of a two-step multivariate optimization strategy, using Plackett–Burman and central composite designs. The method was then evaluated under optimum conditions and a good level of linearity was obtained, with a correlation coefficient of 0.9990. Limits of detection and quantification were 7 μg L−1 and 9 μg L−1, respectively. The repeatability of the proposed method was evaluated at two different spiking levels (20 and 50 μg L−1), and coefficients of variation of 7 % and 5 % (n = 5) were obtained. Tap water and industrial wastewater were selected as real-world water samples to assess the applicability of the method.
Resumo:
The determination of pesticide residues in water samples by Liquid Chromatography require sample preparation for extraction and enrichment of the analytes with the minimization of interferences to achieve adequate detection limits. The Solid Phase Extraction (SPE), Solid Phase Microextraction (SPME), Stir Bar Sorptive Extraction (SBSE) and Dispersive Liquid-Liquid Microextraction (DLLME) techniques have been widely used for extraction of pesticides in water. In this review, the principles of these sample preparation techniques associated with the analysis by Liquid Chromatography with Diode Array Detection (LC-DAD) or Mass Spectrometry (LC-MS) are described and an overview of several applications were presented and discussed.
Resumo:
A new approach for the determination of free and total valproic acid in small samples of 140 μL human plasma based on capillary electrophoresis with contactless conductivity detection is proposed. A dispersive liquid-liquid microextraction technique was employed in order to remove biological matrices prior to instrumental analysis. The free valproic acid was determined by isolating free valproic acid from protein-bound valproic acid by ultrafiltration under centrifugation of 100 μL sample. The filtrate was acidified to turn valproic acid into its protonated neutral form and then extracted. The determination of total valproic acid was carried out by acidifying 40 μL untreated plasma to release the protein-bound valproic acid prior to extraction. A solution consisting of 10 mM histidine, 10 mM 3-(N-morpholino)propanesulfonic acid and 10 μM hexadecyltrimethylammonium bromide of pH 6.5 was used as background electrolyte for the electrophoretic separation. The method showed good linearity in the range of 0.4-300 μg/mL with a correlation coefficient of 0.9996. The limit of detection was 0.08 μg/mL, and the reproducibility of the peak area was excellent (RSD=0.7-3.5%, n=3, for the concentration range from 1 to 150 μg/mL). The results for the free and total valproic acid concentration in human plasma were found to be comparable to those obtained with a standard immunoassay. The corresponding correlation coefficients were 0.9847 for free and 0.9521 for total valproic acid.
Resumo:
A lamotrigina (LTG) é um fármaco pertencente à classe das feniltriazinas utilizado no tratamento de crises epilépticas generalizadas e focais e no tratamento adjunto da epilepsia refratária. Devido à alta variabilidade interindividual, às interações medicamentosas e aos efeitos adversos apresentados durante a administração da LTG, a monitorização terapêutica nos pacientes que fazem uso deste fármaco é necessária para ajuste de dose individual e evitar os efeitos adversos. Assim, o objetivo deste trabalho foi a avaliação de duas técnicas de microextração: a microextração em fase líquida com fibras ocas (HF-LPME) e a microextração líquido-líquido dispersiva (DLLME) para análise da lamotrigina em amostras de plasma de pacientes epilépticos. Primeiramente foram definidas as condições eletroforéticas: foi utilizado um capilar de sílica fundida de 75 ?m de diâmetro interno e 50 cm de comprimento efetivo. O eletrólito de corrida (BGE) foi composto por ácido 2-morfolinoetanosulfônico (MES), na concentração de 130 mmol L-1 e pH 5,0. As análises foram realizadas à temperatura de 20°C e tensão de 15 kV. A amostra foi injetada hidrodinamicamente (0,5 psi por 10 s) e a detecção foi feita em 214 nm. Nestas condições a LTG e o padrão interno (PI), lidocaína, puderam ser analisados em menos de 7 minutos. A HF-LPME foi avaliada no modo de 3 fases, usando 500 ?L de plasma e 3,5 mL de solução fosfato de sódio 50 mmol L-1 pH 9,0 como fase doadora. O solvente utilizado para impregnar a fibra foi o 1-octanol. Como fase aceptora foram utilizados 60 ?L de solução de ácido clorídrico pH 4,0. Para avaliação da DLLME, foi necessária uma etapa de pré-tratamento da amostra (500 ?L de plasma) com 1 mL de acetonitrila. Após isto, 1,3 mL do sobrenadante foram adicionados a 4 mL de solução fosfato de sódio 50 mmol L-1 pH 9,0 e 120 ?L de clorofórmio (solvente extrator) foram injetados nesta amostra aquosa e 165 ?L de fase sedimentada foram recuperados. As características de desempenho analítico para ambos os métodos foram avaliadas, sendo obtida linearidade na faixa de concentração plasmática de 1-20 ?g/mL e limite inferior de quantificação (LIQ) de 1 ?g mL-1. Os ensaios de precisão e exatidão apresentaram valores de acordo com os guias oficiais. Além disso, os métodos foram seletivos, não apresentaram efeito residual e as amostras foram estáveis. Os valores de recuperação foram de 54,3 e 23% para HF-LPME e DLLME, respectivamente. Os métodos validados foram aplicados com sucesso em amostras de plasma de pacientes epilépticos em tratamento com a LTG. Além disso, as duas técnicas foram comparadas e a HF-LPME apresentou vantagens em relação à DLLME, mostrando ser uma técnica promissora para análise de matrizes complexas, com reduzido consumo de solvente orgânico e possibilidade de automação.
Resumo:
Olive (Olea europaea L.), one of the main crops in the Mediterranean basin, is mainly propagated by cuttings, a classical propagation method that relies on the ability of the cuttings to form adventitious roots. While some cultivars are easily propagated by this technique, some of the most interesting olive cultivars are considered difficult-to-root which poses a challenge for their preservation and commercialization. Therefore, increasing the current knowledge on adventitious root formation is extremely important for species like olive. This research focuses on evaluating the role of free auxins and oxidative enzymes on adventitious root formation of two olive cultivars with different rooting ability - ‘Galega vulgar’ (difficult-to-root) and ‘Cobrançosa’ (easy-to-root). In this context, free auxin levels and enzyme activities were determined in in vitro-cultured ‘Galega vulgar’ microshoots and in semi-hardwood cuttings of cvs. ‘Galega vulgar’ and ‘Cobrançosa’. To attain this goal, an analytical method for the quantification of free indole-3-acetic acid (IAA) and indole-3-butyric acid (IBA) was developed, which is based on dispersive liquid-liquid microextraction followed by microwave derivatization (DLLME-MAD) and gas chromatography-mass spectrometry (GC/MS) analysis. The developed method was validated in terms of linearity, recovery, limit of detection (LOD) and limit of quantification (LOQ) and proved to be useful in the analysis of two very different types of plant tissues. The results from auxin quantification in olive samples point at a relationship between free auxin levels and rooting ability of both microshoots and semihardwood cuttings. A defective IBA-IAA conversion, resulting in a peak of free IAA during initiation phase, seems to be associated with low rooting ability. Likewise, differences in the activity of oxidative enzymes also appear to be related with rooting ability. Higher polyphenol oxidases (PPO) activity is likely related with an easyto- root behavior, while the opposite is true for peroxidases (POX) (including IAA oxidase (IAAox)) activity. A possible hypothesis for adventitious root formation in olive microcuttings is presented herein for the first time. Free auxins, oxidative enzymes, alternative oxidase (AOX) and reactive oxygen species (ROS) are some of the factors that may be involved in this highly complex physiological process. Interestingly, while temporal changes in auxin levels were similar between microshoots and semihardwood cuttings, the conclusions obtained from enzyme activity results in microshoots didn’t translate to semi-hardwood tissues, showing the emerging need for adaptation of classical agronomical research studies to modern techniques; Resumo: Procurando compreender o papel das auxinas e enzimas oxidativas na formação de raízes adventícias em cultivares de oliveira (Olea europaea L.) A oliveira (Olea europaea L.) é uma das principais culturas da bacia Mediterrânica e é propagada maioritariamente por estacaria, um processo altamente dependente da capacidade das estacas para formar raízes adventícias. Enquanto algumas cultivares são fáceis de propagar desta forma, algumas das cultivares de oliveira mais interessantes são consideradas difíceis de enraizar, o que dificulta a sua preservação e comercialização e torna extremamente importante aprofundar o conhecimento sobre o enraizamento adventício desta espécie. Este trabalho foca-se na avaliação do papel das auxinas livres e das enzimas oxidativas na formação de raízes adventícias em duas cultivares de oliveira com diferente capacidade de enraizamento - ‘Galega vulgar’ (difícil de enraizar) e ‘Cobrançosa’ (fácil de enraizar). Neste contexto, determinaram-se os níveis de auxinas livres e as actividades de enzimas oxidativas em microestacas de ‘Galega vulgar’ cultivadas in vitro bem como em estacas semi-lenhosas das cvs. ‘Galega vulgar’ e ‘Cobrançosa’. Para tal foi necessário desenvolver uma metodologia analítica para a quantificação de ácido indol-3-acético (IAA) e ácido indol-3-butírico (IBA), baseada em microextracção dispersiva líquido-líquido (DLLME) seguida de derivatização em microondas (MAD) e análise por cromatografia gasosa acoplada a espectrometria de massa (GC/MS). O método desenvolvido foi validado em termos de linearidade, recuperação, limite de detecção (LOD) e limite de quantificação (LOQ), e mostrou-se eficaz na análise de dois tipos de tecidos vegetais bastante diferentes. Os resultados da análise de auxinas em amostras de oliveira apontam para uma possível relação entre os níveis de auxinas livres e a capacidade de enraizamento, tanto em microestacas como em estacas semi-lenhosas. Uma conversão IBA-IAA deficiente, que resulta num pico de IAA durante a fase de iniciação, parece estar associada à baixa capacidade de enraizamento. Por outro lado, a capacidade de enraizamento também parece estar relacionada com diferenças na actividade de enzimas oxidativas. Comportamentos fáceis de enraizar estão associados a actividade mais elevada das polifenoloxidases (PPO), enquanto o oposto é verdade para a actividade das peroxidases (POX) (incluindo a IAA oxidase (IAAox)). Neste trabalho propõe-se pela primeira vez uma possível explicação para o enraizamento adventício em microestacas de oliveira. Auxinas livres, enzimas oxidativas, oxidase alternativa (AOX) e espécies reactivas de oxigénio (ROS) são alguns dos factores envolvidos neste processo fisiológico altamente complexo. Curiosamente, enquanto as alterações temporais nos níveis de auxinas foram semelhantes entre microestacas e estacas semi-lenhosas, o mesmo não se observou relativamente à actividade enzimática, o que mostra a necessidade de adaptação dos estudos agronómicos tradicionais às técnicas correntes.