19 resultados para digitizer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the performance of a novel procedure for segmenting mammograms and detecting clustered microcalcifications in two types of image sets obtained from digitization of mammograms using either a laser scanner, or a conventional ""optical"" scanner. Specific regions forming the digital mammograms were identified and selected, in which clustered microcalcifications appeared or not. A remarkable increase in image intensity was noticed in the images from the optical scanner compared with the original mammograms. A procedure based on a polynomial correction was developed to compensate the changes in the characteristic curves from the scanners, relative to the curves from the films. The processing scheme was applied to both sets, before and after the polynomial correction. The results indicated clearly the influence of the mammogram digitization on the performance of processing schemes intended to detect microcalcifications. The image processing techniques applied to mammograms digitized by both scanners, without the polynomial intensity correction, resulted in a better sensibility in detecting microcalcifications in the images from the laser scanner. However, when the polynomial correction was applied to the images from the optical scanner, no differences in performance were observed for both types of images. (C) 2008 SPIE and IS&T [DOI: 10.1117/1.3013544]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Universidade Estadual de Campinas. Faculdade de Educação Física

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Early detection of landslide surface deformation with 3D remote sensing techniques, as TLS, has become a great challenge during last decade. To improve our understanding of landslide deformation, a series of analogue simulation have been carried out on non-rigid bodies coupled with 3D digitizer. All these experiments have been carried out under controlled conditions, as water level and slope angle inclination. We were able to follow 3D surface deformation suffered by complex landslide bodies from precursory deformation still larger failures. These experiments were the basis for the development of a new algorithm for the quantification of surface deformation using automatic tracking method on discrete points of the slope surface. To validate the algorithm, comparisons were made between manually obtained results and algorithm surface displacement results. Outputs will help in understanding 3D deformation during pre-failure stages and failure mechanisms, which are fundamental aspects for future implementation of 3D remote sensing techniques in early warning systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work parameters of Mg-doped GaN samples were studied using positron annihilation spectroscopy and analyzed. It is shown that gallium vacancies exist in an unintentionally doped sample. Next, the sample with higher concentration of Mg and low growth temperature contains vacancy clusters. In case of low concentration of Mg the growth temperature does not affect the formation of defects. Analog electronics can be replaced by a modern digital device. While promising a high quantity of benefits, the performance of these digitizers requires thorough adjustment. A 14-bit two channel digitizer has been tested in order to achieve better performance than the one of a traditional analog setup, and the adjustment process is described. It has been shown that the digital device is unable to achieve better energy resolution, but it is quite close to the corresponding attribute of the available analog system, which had been used for measurements in Mg-doped GaN.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, a new methodology for the prediction of scoliosis curve types from non invasive acquisitions of the back surface of the trunk is proposed. One hundred and fifty-nine scoliosis patients had their back surface acquired in 3D using an optical digitizer. Each surface is then characterized by 45 local measurements of the back surface rotation. Using a semi-supervised algorithm, the classifier is trained with only 32 labeled and 58 unlabeled data. Tested on 69 new samples, the classifier succeeded in classifying correctly 87.0% of the data. After reducing the number of labeled training samples to 12, the behavior of the resulting classifier tends to be similar to the reference case where the classifier is trained only with the maximum number of available labeled data. Moreover, the addition of unlabeled data guided the classifier towards more generalizable boundaries between the classes. Those results provide a proof of feasibility for using a semi-supervised learning algorithm to train a classifier for the prediction of a scoliosis curve type, when only a few training data are labeled. This constitutes a promising clinical finding since it will allow the diagnosis and the follow-up of scoliotic deformities without exposing the patient to X-ray radiations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper addresses the problem of tracking line segments corresponding to on-line handwritten obtained through a digitizer tablet. The approach is based on Kalman filtering to model linear portions of on-line handwritten, particularly, handwritten numerals, and to detect abrupt changes in handwritten direction underlying a model change. This approach uses a Kalman filter framework constrained by a normalized line equation, where quadratic terms are linearized through a first-order Taylor expansion. The modeling is then carried out under the assumption that the state is deterministic and time-invariant, while the detection relies on double thresholding mechanism which tests for a violation of this assumption. The first threshold is based on an approach of layout kinetics. The second one takes into account the jump in angle between the past observed direction of layout and its current direction. The method proposed enables real-time processing. To illustrate the methodology proposed, some results obtained from handwritten numerals are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the ever increasing demands for high complexity consumer electronic products, market pressures demand faster product development and lower cost. SoCbased design can provide the required design flexibility and speed by allowing the use of IP cores. However, testing costs in the SoC environment can reach a substantial percent of the total production cost. Analog testing costs may dominate the total test cost, as testing of analog circuits usually require functional verification of the circuit and special testing procedures. For RF analog circuits commonly used in wireless applications, testing is further complicated because of the high frequencies involved. In summary, reducing analog test cost is of major importance in the electronic industry today. BIST techniques for analog circuits, though potentially able to solve the analog test cost problem, have some limitations. Some techniques are circuit dependent, requiring reconfiguration of the circuit being tested, and are generally not usable in RF circuits. In the SoC environment, as processing and memory resources are available, they could be used in the test. However, the overhead for adding additional AD and DA converters may be too costly for most systems, and analog routing of signals may not be feasible and may introduce signal distortion. In this work a simple and low cost digitizer is used instead of an ADC in order to enable analog testing strategies to be implemented in a SoC environment. Thanks to the low analog area overhead of the converter, multiple analog test points can be observed and specific analog test strategies can be enabled. As the digitizer is always connected to the analog test point, it is not necessary to include muxes and switches that would degrade the signal path. For RF analog circuits, this is specially useful, as the circuit impedance is fixed and the influence of the digitizer can be accounted for in the design phase. Thanks to the simplicity of the converter, it is able to reach higher frequencies, and enables the implementation of low cost RF test strategies. The digitizer has been applied successfully in the testing of both low frequency and RF analog circuits. Also, as testing is based on frequency-domain characteristics, nonlinear characteristics like intermodulation products can also be evaluated. Specifically, practical results were obtained for prototyped base band filters and a 100MHz mixer. The application of the converter for noise figure evaluation was also addressed, and experimental results for low frequency amplifiers using conventional opamps were obtained. The proposed method is able to enhance the testability of current mixed-signal designs, being suitable for the SoC environment used in many industrial products nowadays.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Analisar os efeitos da ingestão crônica de álcool sobre o nervo óptico em um modelo murino adulto. MÉTODOS: Doze ratos machos da raça Wistar, de 30 dias de idade, foram divididos por sorteio em 2 grupos experimentais: tratado (TG), com 8 animais, alimentados com ração-padrão para roedores de laboratório e uma mistura de água de torneira e etanol ad libitum; controle (CG), com 4 animais, alimentados com a mesma ração e água de torneira pura ad libitum. Após 40 semanas todos os ratos foram sacrificados, sendo os nervos ópticos de ambos os olhos preparados para microscopia óptica e eletrônica. A área de secção transversal de cada nervo a aumento de 500´, assim como número de fibras axonais dentro de 5 campos aleatoriamente selecionados a aumento de 2000´ foram medidos com auxílio de digitalizador de imagens acoplado ao microscópio óptico. Foram realizadas fotomicrografias de 10 campos aleatoriamente selecionados de cada nervo (5 centrais e 5 periféricos) a aumento de 4200´ em microscópio eletrônico de transmissão. RESULTADOS: A análise morfométrica não mostrou diferenças estatisticamente significativas entre os 2 grupos estudados. em contraste com o CG, o exame ultra-estrutural dos nervos ópticos do TG mostrou um intenso desarranjo das bainhas de mielina, que se tornaram espessadas, com separação de suas lamelas, apresentando, por vezes, degenerações interlamelares elétron-densas, além da presença de muitas organelas degeneradas. CONCLUSÃO: Os achados desse estudo mostram alterações ultra-estruturais no nervo óptico de ratos adultos após ingestão crônica de álcool, sem modificações morfométricas significativas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To evaluate the use of the center of the incisive papilla as a guide for the selection of the proper width of maxillary dentures in 4 racial groups. Method and Materials: One hundred sixty stone casts were obtained from impressions of the maxillary arch of white, black, mixed, and Asian subjects. The occlusal surfaces of the casts were photocopied and the images placed on a digitizer. The most anterior and posterior points of the papilla and cusp tips of the canines were digitized. Dentofacial Planner Plus software was used to calculate the distance from a line passing through the cusp tips of the canines to the center of the papilla, defined as the midpoint of the anterior and posterior points of the papilla. The selection error (in millimeters) due to the clinical application of the method of the incisive papilla was calculated and analyzed. Results: In all studied racial groups, there was no coincidence between the center of the incisive papilla and the canine line. The utilization of the center of the papilla would lead to the selection of wider artificial teeth. In 24.9% of the white, 19.3% of the mixed, 32.9% of the black, and 15.5% of the Asian populations, errors greater than 4 mm would be present with the utilization of the papilla. Conclusion: The method of the center of the incisive papilla is not accurate, but may aid in initial artificial teeth selection for the racial groups studied. (Quintessence Int 2008;39:841-845)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article introduces a new method for 3-dimensional dental cast analysis, by using a mechanical 3-dimensional digitizer, MicroScribe 3DX (Immersion, San Jose, Calif), and TIGARO software (not yet released, but available from the author at hayasaki@dent.kyushu-u.ac.jp). By digitizing points on the model, multiple measurements can be made, including tooth dimensions; arch length, width, and perimeter; curve of Spee; overjet and overbite; and anteroposterior discrepancy. The bias of the system can be evaluated by comparing the distance between 2 points as determined by the new system and as measured with digital calipers. Fifteen pairs of models were measured digitally and manually, and the bias was evaluated by comparing the variances of both methods and checking for the type of error obtained by each method. No systematic errors were found. The results showed that the method is accurate, and it can be applied to both clinical practice and research. Copyright © 2005 by the American Association of Orthodontists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the thesis is presented the measurement of the neutrino velocity with the OPERA experiment in the CNGS beam, a muon neutrino beam produced at CERN. The OPERA detector observes muon neutrinos 730 km away from the source. Previous measurements of the neutrino velocity have been performed by other experiments. Since the OPERA experiment aims the direct observation of muon neutrinos oscillations into tau neutrinos, a higher energy beam is employed. This characteristic together with the higher number of interactions in the detector allows for a measurement with a much smaller statistical uncertainty. Moreover, a much more sophisticated timing system (composed by cesium clocks and GPS receivers operating in “common view mode”), and a Fast Waveform Digitizer (installed at CERN and able to measure the internal time structure of the proton pulses used for the CNGS beam), allows for a new measurement with a smaller systematic error. Theoretical models on Lorentz violating effects can be investigated by neutrino velocity measurements with terrestrial beams. The analysis has been carried out with blind method in order to guarantee the internal consistency and the goodness of each calibration measurement. The performed measurement is the most precise one done with a terrestrial neutrino beam, the statistical accuracy achieved by the OPERA measurement is about 10 ns and the systematic error is about 20 ns.