1000 resultados para determinação por FAAS


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work proposes an analytical procedure for direct determination of calcium, magnesium, manganese and zinc in buffalo milk by flame atomic absorption spectrometry (FAAS). Samples were diluted with a solution containing 10% (v/v) of water-soluble tertiary amines (CFA-C) at pH 8. For comparison, buffalo milk samples were digested with HNO3 and H2O2. According to a paired t-test, the results obtained in the determination of Ca, Mg, Mn and Zn in digested samples and in 10% (v/v) CFA-C medium were in agreement at a 95% confidence level. The developed procedure is simple, rapid, decrease the possibility of contamination and can be applied for the routine determination of Ca, Mg, Mn and Zn in buffalo milk samples without any difficulty caused by matrix constituents, such as fat content, and particle size distribution in the milk emulsion.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work proposed a procedure to examine ashes produced in burning lubricating oils used in public transportation, in Teresina PI. Sulphanilic acid was added to the oil samples, which were burned at 550 °C for three hours and 650 °C for two hours. The ash solutions were analyzed by FAAS and there were significant differences in the metal contents of the waste oil produced from normal car service. The quantification limits in μg g-1 were 5.9 (Fe), 4.4 (Pb), 1.7 (Ni), 2.1 (Cu), and 1.2 (Zn). The results showed positive accuracy and precision with recoveries between 88 and 108%, and RSD lower than 10%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper describes the evaluation of a new method of sample preparation using a cold finger system with continuous water flow for rice analysis by flame atomic absorption spectrometry. The limits of detection for Cu, Fe, Mn and Zn for the proposed method were 0.36, 1.84, 2.12 and 0.16 mg kg-1, respectively. The RSDs were lower than 6.0% for all elements and the CRM analyzed showed values with 95% agreement. The proposed method is simple and safe for the proposed objective and does not require the use of mixtures of acid or special equipment for sample preparation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Simple and sensitive procedures for the extraction/preconcentration of molybdenum based on vortex-assisted solidified floating organic drop microextraction (VA-SFODME) and cloud point combined with flame absorption atomic spectrometry (FAAS) and discrete nebulization were developed. The influence of the discrete nebulization on the sensitivity of the molybdenum preconcentration processes was studied. An injection volume of 200 µL resulted in a lower relative standard deviation with both preconcentration procedures. Enrichment factors of 31 and 67 and limits of detection of 25 and 5 µg L-1 were obtained for cloud point and VA-SFODME, respectively. The developed procedures were applied to the determination of Mo in mineral water and multivitamin samples.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este trabalho descreve a síntese e caracterização da sílica gel modificada com grupos 2-aminotiazol (SiAT), os resultados de um estudo de adsorção e de pré-concentração (em batelada, e em fluxo utilizando-se a técnica de coluna) de íons Cd(II) em meio aquoso. A capacidade máxima de adsorção de íons Cd(II) determinada para SiAT foi de 1,12 mmol g-1 . Os resultados obtidos nos experimentos em fluxo, mostraram uma recuperação de 98% dos íons Cd(II) adsorvidos em coluna empacotada com 1 g de SiAT, utilizando-se 5 mL de HCl 1 mol L-1 como eluente. A metodologia proposta mostrou-se linear na faixa de concentração de 10 - 100 mg L-1, com limite de detecção de 0,80 mg L-1 e desvio padrão relativo de 3%. O fator de enriquecimento determinado foi de 29 vezes (considerando-se a percolação de 150 mL de solução 25 mg L-1 de Cd(II), 5 mL de eluato). A sorção-desorção quantitativa dos íons Cd(II), permitiram a aplicação do método na pré-concentração e posterior quantificação de traços de Cd(II) em amostras de águas naturais por espectrometria de absorção atômica com chama.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Este trabalho propõe o desenvolvimento de um procedimento analítico para a determinação em linha de estanho em soluções analíticas empregando a técnica de espectrometria de absorção atômica com nebulização térmica em tubo metálico aquecido na chama (TS-FF-AAS) como alternativa ao uso da chama de óxido nitroso-acetileno em espectrometria de absorção atômica, cujo comburente apresenta um custo elevado frente ao ar comprimido. Foram avaliados parâmetros para a otimização do sistema, tais como: vazão do carregador (ar), volume de amostra injetada e concentração do ácido (HCl). Foi construída curva analítica linear [A= -0,00163 + 0,00319 [Sn], (r= 0,9998)] no intervalo de 10 a 80 mg Sn L-1. O limite de detecção, o desvio padrão relativo (n=12) e a freqüência analítica foram: 1,7 mg L-1 Sn, £ 2,7% and 120 h-1 respectivamente. O sistema TS-FF-AAS é uma alternativa para a determinação de Sn.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

ABSTRACT: This work proposes an analytical procedure for direct determination of calcium, magnesium, manganese and zinc in buffalo milk by flame atomic absorption spectrometry (FAAS). Samples were diluted with a solution containing 10% (v/v) of water-soluble tertiary amines (CFA-C) at pH 8. For comparison, buffalo milk samples were digested with HNO3 and H2O2. According to a paired t-test, the results obtained in the determination of Ca, Mg, Mn and Zn in digested samples and in 10% (v/v) CFA-C medium were in agreement at a 95% confidence level. The developed procedure is simple, rapid, decrease the possibility of contamination and can be applied for the routine determination of Ca, Mg, Mn and Zn in buffalo milk samples without any difficulty caused by matrix constituents, such as fat content, and particle size distribution in the milk emulsion

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the present work four different analytical methodologies were studied for the determination of iron and titanium in Portland cement. The cement samples were dissolved with hot HCl and HF, being compared Fe and Ti concentrations through four analytical methods: molecular absorption spectrophotometry using the reagents 1,2-hydroxybenzene-3,5-disulfonic acid (Tiron) and the 5-chloro-salicylic acid (CSA), inductively coupled plasma atomic emission spectrometry (ICP-AES) and flame atomic absorption spectrophotometry (FAAS). In the spectrophotometric determinations were studied pH conditions, reagents addition order, interferences, amount of reagents, linear range and stability of the system. In the techniques of ICP-AES and FAAS were studied the best lines, interferences, sensibility and linear range. The obtained results were compared and the agreement was evaluated among the methods for the determination of the metals of interest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a sequential injection analysis (SIA) set-up coupled to a flame atomic absorption spectrometer (FAAS) to accomplish the determination of low concentrations of copper in drinking waters. Copper is first retained under neutral media in an on-line 29x1.6 mm column filled with poly(ethylenimine) immobilised on silica gel. The retained analyte is then eluted by flowing through the column 250 mL of a nitric acid solution. The selection of 3.85 ml of sample enabled to obtain a detection limit of 0.27 mug/L and a sampling rate of about 24 samples/h. There was a good agrement between the results of 12 samples furnished by the proposed procedure and by electrothermal atomic absorption spectrometry. Repeatability assessment gave a relative standard deviation of 1.3 % after ten replicate analysis of a sample containing about 70 mug/L in copper..

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to demonstrate the feasibility of slurry sampling for environmental studies, different methodologies were developed for Cu and Zn in antarctic limpets and Ni in river sediment with FAAS detection. Studies focusing particle size, acid concentration, slurry stability, selectivity, among others were carried out in order to define the better conditions for slurry analysis. A study related to the depth profile for Ni in the Atibaia River sediment was made after optimization conditions for this element. For accuracy check, certified reference material was used as well as decomposition with microwave oven.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for determination of lead and cadmium in aqueous samples using solvent microextraction and dithizone as complexing agent with FAAS was developed. Solvent microextraction parameters were optimized. The effect of foreign ions on the extraction yields was studied. The extraction was carried out until the aqueous to organic phase ratio achieved a 250 fold preconcentration of metals. For preconcentration times of 4 min the 3sigma detection limits, relative standard deviations (n=7) and linear calibration ranges were 1.6 mug L-1, 5.8% and 10.0 -- 80.0 mug L-1 for lead and 11.1 ng L-1, 5.9% and 0.3 -- 3.0 mug L-1 for cadmium, respectively. The solvent microextraction procedure presented here was applied to the determination of lead and cadmium in natural waters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O presente trabalho reporta um método para a determinação de cromo (VI) por espectrometria de absorção atômica com chama (FAAS) após a extração e pré-concentração no ponto nuvem. O cromo (VI) é complexado com 1,5-difenilcarbazida (DFC) em meio ácido (pH 2,0) e é extraído para um volume de fase rica de 25 µL, com o uso do surfactante Triton X-114. As variáveis que afetam a formação do ponto nuvem, tais como a concentração de surfactante (0,1-1,0% m/v) e de complexante (0,01-0,80% m/v), o tempo de complexação (0-60 min) e o efeito da adição do eletrólito NaCl (0-20% m/v), são avaliadas. Sob condições otimizadas, são utilizados o Triton X-114 a 0,3% m/v, a DFC a 0,05% m/v e o NaCl a 10% m/v para a extração do cromo (VI). Esse método fornece limites de detecção e quantificação de 0,4 µg L-1 e 1,5 µg L-1, respectivamente, e uma faixa linear de calibração de 5 a 500 µg L-1. O fator de pré-concentração obtido é igual a 27 e a eficiência de extração varia de 87 a 99,3%.