21 resultados para cycloplegia
Resumo:
Objective: To determine whether bifocal and prismatic bifocal spectacles could control myopia in children with high rates of myopic progression. ---------- Methods: This was a randomized controlled clinical trial. One hundred thirty-five (73 girls and 62 boys) myopic Chinese Canadian children (myopia of 1.00 diopters [D]) with myopic progression of at least 0.50 D in the preceding year were randomly assigned to 1 of 3 treatments: (1) single-vision lenses (n = 41), (2) +1.50-D executive bifocals (n = 48), or (3) +1.50-D executive bifocals with a 3–prism diopters base-in prism in the near segment of each lens (n = 46). ---------- Main Outcome Measures: Myopic progression measured by an automated refractor under cycloplegia and increase in axial length (secondary) measured by ultrasonography at 6-month intervals for 24 months. Only the data of the right eye were used. ---------- Results: Of the 135 children (mean age, 10.29 years [SE, 0.15 years]; mean visual acuity, –3.08 D [SE, 0.10 D]), 131 (97%) completed the trial after 24 months. Myopic progression averaged –1.55 D (SE, 0.12 D) for those who wore single-vision lenses, –0.96 D (SE, 0.09 D) for those who wore bifocals, and –0.70 D (SE, 0.10 D) for those who wore prismatic bifocals. Axial length increased an average of 0.62 mm (SE, 0.04 mm), 0.41 mm (SE, 0.04 mm), and 0.41 mm (SE, 0.05 mm), respectively. The treatment effect of bifocals (0.59 D) and prismatic bifocals (0.85 D) was significant (P < .001) and both bifocal groups had less axial elongation (0.21 mm) than the single-vision lens group (P < .001). ---------- Conclusions: Bifocal lenses can moderately slow myopic progression in children with high rates of progression after 24 months.
Resumo:
Purpose: We compared subjective blur limits for defocus and the higher-order aberrations of coma, trefoil, and spherical aberration. ---------- Methods: Spherical aberration was presented in both Zernike and Seidel forms. Black letter targets (0.1, 0.35, and 0.6 logMAR) on white backgrounds were blurred using an adaptive optics system for six subjects under cycloplegia with 5 mm artificial pupils. Three blur criteria of just noticeable, just troublesome, and just objectionable were used.---------- Results: When expressed as wave aberration coefficients, the just noticeable blur limits for coma and trefoil were similar to those for defocus, whereas the just noticeable limits for Zernike spherical aberration and Seidel spherical aberration (the latter given as an “rms equivalent”) were considerably smaller and larger, respectively, than defocus limits.---------- Conclusions: Blur limits increased more quickly for the higher order aberrations than for defocus as the criterion changed from just noticeable to just troublesome and then to just objectionable.
Resumo:
Abstract—The role of cardiopulmonary signals in the dynamics of wavefront aberrations in the eye has been examined. Synchronous measurement of the eye’s wavefront aberrations, cardiac function, blood pulse, and respiration signals were taken for a group of young, healthy subjects. Two focusing stimuli, three breathing patterns, as well as natural and cycloplegic eye conditions were examined. A set of tools, including time–frequency coherence and its metrics, has been proposed to acquire a detailed picture of the interactions of the cardiopulmonary system with the eye’s wavefront aberrations. The results showed that the coherence of the blood pulse and its harmonics with the eye’s aberrations was, on average, weak (0.4 ± 0.15), while the coherence of the respiration signal with eye’s aberrations was, on average, moderate (0.53 ± 0.14). It was also revealed that there were significant intervals during which high coherence occurred. On average, the coherence was high (>0.75) during 16% of the recorded time, for the blood pulse, and 34% of the time for the respiration signal. A statistically significant decrease in average coherence was noted for the eye’s aberrations with respiration in the case of fast controlled breathing (0.5 Hz). The coherence between the blood pulse and the defocus was significantly larger for the far target than for the near target condition. After cycloplegia, the coherence of defocus with the blood pulse significantly decreased, while this was not the case for the other aberrations. There was also a noticeable, but not statistically significant, increase in the coherence of the comatic term and respiration in that case. By using nonstationary measures of signal coherence, a more detailed picture of interactions between the cardiopulmonary signals and eye’s wavefront aberrations has emerged.
Resumo:
The depth of focus (DOF) can be defined as the variation in image distance of a lens or an optical system which can be tolerated without incurring an objectionable lack of sharpness of focus. The DOF of the human eye serves a mechanism of blur tolerance. As long as the target image remains within the depth of focus in the image space, the eye will still perceive the image as being clear. A large DOF is especially important for presbyopic patients with partial or complete loss of accommodation (presbyopia), since this helps them to obtain an acceptable retinal image when viewing a target moving through a range of near to intermediate distances. The aim of this research was to investigate the DOF of the human eye and its association with the natural wavefront aberrations, and how higher order aberrations (HOAs) can be used to expand the DOF, in particular by inducing spherical aberrations ( 0 4 Z and 0 6 Z ). The depth of focus of the human eye can be measured using a variety of subjective and objective methods. Subjective measurements based on a Badal optical system have been widely adopted, through which the retinal image size can be kept constant. In such measurements, the subject.s tested eye is normally cyclopleged. Objective methods without the need of cycloplegia are also used, where the eye.s accommodative response is continuously monitored. Generally, the DOF measured by subjective methods are slightly larger than those measured objectively. In recent years, methods have also been developed to estimate DOF from retinal image quality metrics (IQMs) derived from the ocular wavefront aberrations. In such methods, the DOF is defined as the range of defocus error that degrades the retinal image quality calculated from the IQMs to a certain level of the possible maximum value. In this study, the effect of different amounts of HOAs on the DOF was theoretically evaluated by modelling and comparing the DOF of subjects from four different clinical groups, including young emmetropes (20 subjects), young myopes (19 subjects), presbyopes (32 subjects) and keratoconics (35 subjects). A novel IQM-based through-focus algorithm was developed to theoretically predict the DOF of subjects with their natural HOAs. Additional primary spherical aberration ( 0 4 Z ) was also induced in the wavefronts of myopes and presbyopes to simulate the effect of myopic refractive correction (e.g. LASIK) and presbyopic correction (e.g. progressive power IOL) on the subject.s DOF. Larger amounts of HOAs were found to lead to greater values of predicted DOF. The introduction of primary spherical aberration was found to provide moderate increase of DOF while slightly deteriorating the image quality at the same time. The predicted DOF was also affected by the IQMs and the threshold level adopted. We then investigated the influence of the chosen threshold level of the IQMs on the predicted DOF, and how it relates to the subjectively measured DOF. The subjective DOF was measured in a group of 17 normal subjects, and we used through-focus visual Strehl ratio based on optical transfer function (VSOTF) derived from their wavefront aberrations as the IQM to estimate the DOF. The results allowed comparison of the subjective DOF with the estimated DOF and determination of a threshold level for DOF estimation. Significant correlation was found between the subject.s estimated threshold level for the estimated DOF and HOA RMS (Pearson.s r=0.88, p<0.001). The linear correlation can be used to estimate the threshold level for each individual subject, subsequently leading to a method for estimating individual.s DOF from a single measurement of their wavefront aberrations. A subsequent study was conducted to investigate the DOF of keratoconic subjects. Significant increases of the level of HOAs, including spherical aberration, coma and trefoil, can be observed in keratoconic eyes. This population of subjects provides an opportunity to study the influence of these HOAs on DOF. It was also expected that the asymmetric aberrations (coma and trefoil) in the keratoconic eye could interact with defocus to cause regional blur of the target. A dual-Badal-channel optical system with a star-pattern target was used to measure the subjective DOF in 10 keratoconic eyes and compared to those from a group of 10 normal subjects. The DOF measured in keratoconic eyes was significantly larger than that in normal eyes. However there was not a strong correlation between the large amount of HOA RMS and DOF in keratoconic eyes. Among all HOA terms, spherical aberration was found to be the only HOA that helped to significantly increase the DOF in the studied keratoconic subjects. Through the first three studies, a comprehensive understanding of DOF and its association to the HOAs in the human eye had been achieved. An adaptive optics system was then designed and constructed. The system was capable of measuring and altering the wavefront aberrations in the subject.s eye and measuring the resulting DOF under the influence of different combination of HOAs. Using the AO system, we investigated the concept of extending the DOF through optimized combinations of 0 4 Z and 0 6 Z . Systematic introduction of a targeted amount of both 0 4 Z and 0 6 Z was found to significantly improve the DOF of healthy subjects. The use of wavefront combinations of 0 4 Z and 0 6 Z with opposite signs can further expand the DOF, rather than using 0 4 Z or 0 6 Z alone. The optimal wavefront combinations to expand the DOF were estimated using the ratio of increase in DOF and loss of retinal image quality defined by VSOTF. In the experiment, the optimal combinations of 0 4 Z and 0 6 Z were found to provide a better balance of DOF expansion and relatively smaller decreases in VA. Therefore, the optimal combinations of 0 4 Z and 0 6 Z provides a more efficient method to expand the DOF rather than 0 4 Z or 0 6 Z alone. This PhD research has shown that there is a positive correlation between the DOF and the eye.s wavefront aberrations. More aberrated eyes generally have a larger DOF. The association of DOF and the natural HOAs in normal subjects can be quantified, which allows the estimation of DOF directly from the ocular wavefront aberration. Among the Zernike HOA terms, spherical aberrations ( 0 4 Z and 0 6 Z ) were found to improve the DOF. Certain combinations of 0 4 Z and 0 6 Z provide a more effective method to expand DOF than using 0 4 Z or 0 6 Z alone, and this could be useful in the optimal design of presbyopic optical corrections such as multifocal contact lenses, intraocular lenses and laser corneal surgeries.
Resumo:
Purpose: We investigated the interaction between adapting field size and luminance on pupil diameter when cones alone (photopic) or rods and cones (mesopic) were active. Method: Circular achromatic targets (1o to 24o diameter) were presented to eight young participants on a rectangular projector screen. The accommodative influence on pupil diameter was minimized using cycloplegia in the fixing right eye and the consensual pupil reflex was measured in the left eye. Target luminance was adjusted for each stimulus such that corneal flux density (product of field area and luminance) was constant at 3600 cd.deg2m-2 (photopic condition) and 1.49 cd.deg2m-2 (mesopic condition). Results: There were no statistically significant effects of adaptive field size on pupil diameter for either condition. Conclusion: If corneal flux density is kept constant, there will be no change in pupil diameter as the size of the stimulus field increases at either mesopic or photopic lighting levels up to at least 24°.
Resumo:
Purpose: The prevalence of refractive errors in children has been extensively researched. Comparisons between studies can, however, be compromised because of differences between accommodation control methods and techniques used for measuring refractive error. The aim of this study was to compare spherical refractive error results obtained at baseline and using two different accommodation control methods – extended optical fogging and cycloplegia, for two measurement techniques – autorefraction and retinoscopy. Methods: Participants comprised twenty-five school children aged between 6 and 13 years (mean age: 9.52 ± 2.06 years). The refractive error of one eye was measured at baseline and again under two different accommodation control conditions: extended optical fogging (+2.00DS for 20 minutes) and cycloplegia (1% cyclopentolate). Autorefraction and retinoscopy were both used to measure most plus spherical power for each condition. Results: A significant interaction was demonstrated between measurement technique and accommodation control method (p = 0.036), with significant differences in spherical power evident between accommodation control methods for each of the measurement techniques (p < 0.005). For retinoscopy, refractive errors were significantly more positive for cycloplegia compared to optical fogging, which were in turn significantly more positive than baseline, while for autorefraction, there were significant differences between cycloplegia and extended optical fogging and between cycloplegia and baseline only. Conclusions: Determination of refractive error under cycloplegia elicits more plus than using extended optical fogging as a method to relax accommodation. These findings support the use of cycloplegic refraction compared with extended optical fogging as a means of controlling accommodation for population based refractive error studies in children.
Resumo:
Purpose to evaluate the effects of the wearer’s pupil size and spherical aberration on visual performance with centre-near, aspheric multifocal contact lenses (MFCLs). The advantage of binocular over monocular vision was also investigated. Methods Twelve young volunteers, with an average age of 27±5 years, participated in the study. LogMAR Visual Acuity (VA) was measured under cycloplegia for a range of defocus levels (from +3.0 to -3.0D, in 0.5D steps) with no correction and with three aspheric MFCLs (Air Optix Aqua Multifocal, Ciba Vision, Duluth, GA, US) with a centre-near design, providing correction for “Low”, “Med” and “High” near demands. Measurements were performed for all combinations of the following conditions: i) artificial pupils of 6mm and 3mm diameter, ii) binocular and monocular (dominant eye) vision. Depth-of-focus (DOF) was calculated from the VA vs. defocus curves. Ocular aberrations under cycloplegia were measured using iTrace. Results VA at -3.0D defocus (simulating near performance) was statistically higher for the 3mm than for the 6mm pupil (p=0.006), and for binocular rather than for monocular vision (p<0.001). Similarly, DOF was better for the 3mm pupil (p=0.002) and for binocular viewing conditions (p<0.001, ANOVA). Both VA at –3.0D defocus and DOF increased as the “addition” of the MFCL correction increased. Finally, with the centre-near MFCLs a linear correlation was found between VA at –3.0D defocus and the wearer’s ocular spherical aberration (R2=0.20 p<0.001 for 6mm data), with the eyes exhibiting the higher positive spherical aberration experiencing lower VAs. By contrast, no correlation was found between VA and spherical aberration at 0.00D defocus (distance vision). Conclusions Both near VA and depth-of-focus improve with these MFCLs, with the effects being more pronounced for small pupils and binocular than for monocular vision. Coupling of the wearer’s ocular spherical aberration with the aberration profiles provided by MFCLs affects their functionality.
Resumo:
Importance Myopia is a significant public health problem, making it important to determine whether a bifocal spectacle treatment involving near prism slows myopia progression in children. Objective To determine whether bifocal and prismatic bifocal spectacles control myopia in children with high rates of myopia progression and to assess whether the treatment effect is dependent on the lag of accommodation and/or near phoria status. Design, Setting, and Participants This 3-year randomized clinical trial was conducted in a private practice. A total of 135 (73 female and 62 male) Chinese-Canadian children (aged 8-13 years; mean [SE] age, 10.29 [0.15] years; mean [SE] myopia, −3.08 [0.10] D) with myopia progression of at least 0.50 D in the preceding year were randomly assigned to 1 of 3 treatments. A total of 128 (94.8%) completed the trial. Interventions Single-vision lenses (control, n = 41), +1.50-D executive bifocals (n = 48), and +1.50-D executive bifocals with 3-Δ base-in prism in the near segment of each lens (n = 46). Main Outcomes and Measures Myopia progression (primary) measured using an automated refractor following cycloplegia and increase in axial length (secondary) measured using ultrasonography at intervals of 6 months for 36 months. Results Myopia progression over 3 years was an average (SE) of −2.06 (0.13) D for the single-vision lens group, −1.25 (0.10) D for the bifocal group, and −1.01 (0.13) D for the prismatic bifocal group. Axial length increased an average (SE) of 0.82 (0.05) mm, 0.57 (0.07) mm, and 0.54 (0.06) mm, respectively. The treatment effect of bifocals (0.81 D) and prismatic bifocals (1.05 D) was significant (P < .001). Both bifocal groups had less axial elongation (0.25 mm and 0.28 mm, respectively) than the single-vision lens group (P < .001). For children with high lags of accommodation (≥1.01 D), the treatment effect of both bifocals and prismatic bifocals was similar (1.1 D) (P < .001). For children with low lags (<1.01 D), the treatment effect of prismatic bifocals (0.99 D) was greater than of bifocals (0.50 D) (P = .03). The treatment effect of both bifocals and prismatic bifocals was independent of the near phoria status. Conclusions and Relevance Bifocal spectacles can slow myopia progression in children with an annual progression rate of at least 0.50 D after 3 years. These results suggest that prismatic bifocals are more effective for myopic children with low lags of accommodation.
Resumo:
Purpose To test the hypothesis that relative peripheral hyperopia predicts development and progression of myopia. Methods Refraction along the horizontal visual field was measured under cycloplegia at visual field angles of 0°, ±15°, and ±30° at baseline, 1 and 2 years in over 1700 initially 7-year-old Chinese children, and at baseline and 1 year in over 1000 initially 14-year olds. One refraction classification for central refraction was “nonmyopia, myopia” (nM, M), consisting of nM greater than −0.50 diopters (D; spherical equivalent) and M less than or equal to −0.50 D. A second classification was “hyperopia, emmetropia, low myopia, and moderate/high myopia” (H, E, LM, MM) with H greater than or equal to +1.00 D, E, −0.49 to +0.99 D, LM, −2.99 to −0.50 D, and MM less than or equal to −3.00 D. Subclassifications were made on the basis of development and progression of myopia over the 2 years. Changes in central refraction over time were determined for different groups, and relative peripheral refraction over time was compared between different subgroups. Results Simple linear regression of central refraction as a function of relative peripheral refraction did not predict myopia progression as relative peripheral refraction became more hyperopic: relative peripheral hyperopia and relative peripheral myopia predicted significant myopia progression for 0% and 35% of group/visual field angle combinations, respectively. Subgroups who developed myopia did not have more initial relative peripheral hyperopia than subgroups who did not develop myopia. Conclusions Relative peripheral hyperopia does not predict development nor progression of myopia in children. This calls into question the efficacy of treatments that aim to slow progression of myopia in children by “treating” relative peripheral hyperopia.
Resumo:
Purpose. We assessed the prevalence and predictors of inaccurate refractive error among rural refractionists in western China. Methods. A subset of primary school children with visual acuity (VA) ≤6/12 in ≥1 eye, undergoing subjective refinement by local refractionists after cycloplegic autorefraction in an ongoing population-based study, received repeat refraction by university optometrists for quality control. Results. Among 502 children (mean age 10.5 years, 53.2% girls), independent predictors of poor (inaccurate by ≥1.0 diopter [D]) refraction by 21 rural practitioners (66.7% with high school or lower education) included hyperopia (odds ratio [OR], 4.2; 95% confidence interval [CI], 2.4-7.3, P < 0.001), astigmatism (OR = 3.8; 95% CI, 2.5-5.6; P < 0.001) and VA uncorrectable to >6/12 by the rural refractionist (OR = 4.7; 95% CI, 3.1-7.3; P = < 0.001). Among 201 children whose vision was uncorrectable in ≥1 eye by the rural refractionists, vision could be improved to >6/12 by the university optometrist in 110 (54.7%). We estimate vision could be so improved in 9.1% of all children refracted by these rural refractionists. A reason for inaccuracy in this setting is the erroneous tendency of rural refractionists to adjust instrument values for accommodation, even under cycloplegia. Conclusions. Rural refractionists in western China have little formal training and frequently fail to optimize VA among children, even when autorefractors are used. Training is needed emphasizing better use of automated refraction, particularly in children with astigmatism and hyperopia. © 2014 The Association for Research in Vision and Ophthalmology, Inc.
Resumo:
OBJECTIVE: To compare visual and refractive outcomes between self-refracting spectacles (Adaptive Eyecare, Ltd, Oxford, UK), noncycloplegic autorefraction, and cycloplegic subjective refraction. DESIGN: Cross-sectional study. PARTICIPANTS: Chinese school-children aged 12 to 17 years. METHODS: Children with uncorrected visual acuity ≤ 6/12 in either eye underwent measurement of the logarithm of the minimum angle of resolution visual acuity, habitual correction, self-refraction without cycloplegia, autorefraction with and without cycloplegia, and subjective refraction with cycloplegia. MAIN OUTCOME MEASURES: Proportion of children achieving corrected visual acuity ≥ 6/7.5 with each modality; difference in spherical equivalent refractive error between each of the modalities and cycloplegic subjective refractive error. RESULTS: Among 556 eligible children of consenting parents, 554 (99.6%) completed self-refraction (mean age, 13.8 years; 59.7% girls; 54.0% currently wearing glasses). The proportion of children with visual acuity ≥ 6/7.5 in the better eye with habitual correction, self-refraction, noncycloplegic autorefraction, and cycloplegic subjective refraction were 34.8%, 92.4%, 99.5% and 99.8%, respectively (self-refraction versus cycloplegic subjective refraction, P<0.001). The mean difference between cycloplegic subjective refraction and noncycloplegic autorefraction (which was more myopic) was significant (-0.328 diopter [D]; Wilcoxon signed-rank test P<0.001), whereas cycloplegic subjective refraction and self-refraction did not differ significantly (-0.009 D; Wilcoxon signed-rank test P = 0.33). Spherical equivalent differed by ≥ 1.0 D in either direction from cycloplegic subjective refraction more frequently among right eyes for self-refraction (11.2%) than noncycloplegic autorefraction (6.0%; P = 0.002). Self-refraction power that differed by ≥ 1.0 D from cycloplegic subjective refractive error (11.2%) was significantly associated with presenting without spectacles (P = 0.011) and with greater absolute power of both spherical (P = 0.025) and cylindrical (P = 0.022) refractive error. CONCLUSIONS: Self-refraction seems to be less prone to accommodative inaccuracy than noncycloplegic autorefraction, another modality appropriate for use in areas where access to eye care providers is limited. Visual results seem to be comparable. Greater cylindrical power is associated with less accurate results; the adjustable glasses used in this study cannot correct astigmatism. Further studies of the practical applications of this modality are warranted. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found after the references.
Resumo:
OBJECTIVE: To compare outcomes between adjustable spectacles and conventional methods for refraction in young people. DESIGN: Cross sectional study. SETTING: Rural southern China. PARTICIPANTS: 648 young people aged 12-18 (mean 14.9 (SD 0.98)), with uncorrected visual acuity ≤ 6/12 in either eye. INTERVENTIONS: All participants underwent self refraction without cycloplegia (paralysis of near focusing ability with topical eye drops), automated refraction without cycloplegia, and subjective refraction by an ophthalmologist with cycloplegia. MAIN OUTCOME MEASURES: Uncorrected and corrected vision, improvement of vision (lines on a chart), and refractive error. RESULTS: Among the participants, 59% (384) were girls, 44% (288) wore spectacles, and 61% (393/648) had 2.00 dioptres or more of myopia in the right eye. All completed self refraction. The proportion with visual acuity ≥ 6/7.5 in the better eye was 5.2% (95% confidence interval 3.6% to 6.9%) for uncorrected vision, 30.2% (25.7% to 34.8%) for currently worn spectacles, 96.9% (95.5% to 98.3%) for self refraction, 98.4% (97.4% to 99.5%) for automated refraction, and 99.1% (98.3% to 99.9%) for subjective refraction (P = 0.033 for self refraction v automated refraction, P = 0.001 for self refraction v subjective refraction). Improvements over uncorrected vision in the better eye with self refraction and subjective refraction were within one line on the eye chart in 98% of participants. In logistic regression models, failure to achieve maximum recorded visual acuity of 6/7.5 in right eyes with self refraction was associated with greater absolute value of myopia/hyperopia (P<0.001), greater astigmatism (P = 0.001), and not having previously worn spectacles (P = 0.002), but not age or sex. Significant inaccuracies in power (≥ 1.00 dioptre) were less common in right eyes with self refraction than with automated refraction (5% v 11%, P<0.001). CONCLUSIONS: Though visual acuity was slightly worse with self refraction than automated or subjective refraction, acuity was excellent in nearly all these young people with inadequately corrected refractive error at baseline. Inaccurate power was less common with self refraction than automated refraction. Self refraction could decrease the requirement for scarce trained personnel, expensive devices, and cycloplegia in children's vision programmes in rural China.
Resumo:
The objective of this study is to estimate the prevalence of Ocular Toxocariasis, Diffuse Unilateral Subacute Neuroretinitis (DUSN), Toxoplasma gondii infection and Ocular Toxoplasmosis in a student population in Natal-RN/Brazil and relate it to demographic, epidemiologic and socio-economic risk factors. The incidence of DUSN was observed in patients at the Federal University of Rio Grande do Norte Ophthalmology Service and the Prontoclinica de Olhos Ophthalmology clinic in Natal. In cases where a worm was found in the subretinal space, the result of treatment with photocoagulation using Green Laser (Eye Light ALCON) was evaluated in relation to final visual result. The sample was randomly selected among the schools of the four districts of Natal, according to the type of institution (public or private), its level (elementary or secondary), and study period (morning, afternoon or evening). The school population was studied from March to May, 2001. Initially, the students answered a questionnaire to evaluate demographic, epidemiologic and socio-economic risk factors. Afterwards, the following procedures were carried out: blood samples were taken for Toxoplasmosis (IgG, IgM) serology, hemogram, ophthalmological examination, consisting of clinical history, measurement of visual acuity, refraction under cycloplegia, biomicroscopy of the anterior segment and annexa, funduscopy and examination of extrinsic motility. The prevalence of Toxocariasis was 0.2% or 2 per one thousand students. The sample was insufficient to estimate the prevalence of DUSN. Seventy patients with DUSN diagnosis were examined from January, 2001 to January, 2003. A live worm was found in the subretinal space of all four patients in the acute phase, and these were treated with laser photocoagulation. After follow-up (average = 11.5 months), visual acuity improved in three eyes and remained unaltered in one eye. Worms were found in 22 of the 66 patients in the chronic phase, and these also were treated with laser photocoagulation. After a follow-up period of 13.1 months, on average, visual acuity improved in two of the patients, remained unchanged in 19 and worsened in one. The comparison of visual result before and after treatment was not statistically significant (p = 0.302). The diagnosis of DUSN in the acute phase, followed by prompt localization and destruction of the worm by photocoagulation, can improve the patient s vision. However, destruction of the worm by laser photocoagulation in eyes with DUSN in the chronic phase does not improve visual acuity. Seroprevalence for IgG was 46% (Confidence Interval CI 95%-42.9-49.2%) and for IgM it was 1.4% (CI 95% = 0.8-2.4%). The prevalence of ocular lesion was 1.15% (CI 95% = 0.6 - 2.0%). Socio-economic conditions were determinants in the prevalence of Systemic and Ocular Toxoplasmosis in the bivaried analysis and confirmed in the multivaried analysis (mother s scholarity illiterate/ OR = 2.9 and p < 0.001). The T. gondii infection prevalence, although high, was less than that found in studies performed in the South and Southeast of Brazil and that of Ocular Toxoplasmosis was completely discrepant, varying from 5 to 17 times less. Although important epidemiological variables such as owning a cat, drinking unfiltered water, and coming into contact with rivers or lakes showed an association in the preliminary analysis, they lost their influence when included in the logistic model. Future studies are scheduled to begin in March, 2004, in collaboration with other Brazilian and American universities in an attempt to discover the reason for these findings, as well as identifying the different strains of Toxoplasma gondii, and studying the sources of water utilized by the population of Natal Brazil
Resumo:
OBJETIVO: O objetivo geral foi detectar fatores ambliopigênicos em uma população de pré-escolares, utilizando exames refratométricos e o PhotoScreenerTM (PS) e o objetivo específico foi verificar se a avaliação feita com o PS é útil como método de triagem em campanhas de prevenção de ambliopia em crianças. MÉTODOS: Foi realizado um estudo observacional, prospectivo, de janeiro a dezembro de 2007, avaliando-se 227 crianças pré-escolares, com o intuito de detectar, através da aplicação de um questionário, exames refratométricos e fotografias utilizando o PS, a presença de fatores causadores de ambliopia na população de estudo. Todas as crianças foram avaliadas pelo PS. em seguida, todas as crianças foram submetidas à cicloplegia , sendo avaliadas usando refrator automático Shin Nippon®. As crianças detectadas como portadoras de problemas oculares receberam prescrição óptica, segundo os critérios: hipermetropia maior que +1,50 D, miopia maior que -1,00 D e astigmatismo maior que 1,00 D. Analisaram-se os dados através do teste de concordância de Goodman, estatística descritiva e estudo da especificidade e sensibilidade ao emprego do PS, comparando os resultados com ele obtidos, com os resultados dos outros métodos de avaliação oftalmológica. RESULTADOS: A distribuição entre os sexos foi semelhante, sendo que a maioria das crianças apresentava quatro ou cinco anos de idade. A sensibilidade (S) do PS, comparando-se o resultado obtido neste aparelho com o autorrefrator sob cicloplegia, foi de 50,9%. Já a especificidade foi de 78,9%; valor preditivo positivo 70%; valor preditivo negativo 62,5% e acurácia 65,1%. CONCLUSÕES: Das 101 crianças cujas fotografias tiradas através do PS puderam ser analisadas satisfatoriamente, trinta e seis apresentavam erro refrativo que necessitou de correção. O PS, quando comparado com equivalente esférico do autorrefrator sob cicloplegia, é um método razoável de triagem, embora a sensibilidade não seja boa. Um ponto positivo a ser ressaltado é o considerável valor de especificidade.
Resumo:
Purpose: To show the importance of the cicloplegic method in the refraction evaluation comparing the automated refraction (subjective and objective) and the subjective static refraction. Method: One-hundred patients (200 eyes) between 5 and 40 years were prospectivelly evaluated according the static and dynamic automated refraction and the subjective static refraction, using an automated refractor Nidek ARK - 900. The data were submitted to statical evaluation. Results: The concordance indices were better after cycloplegia mainly in relation of the spheric degree and cílindric axes. Conclusion: Cycloplegia is very important to have accurace in the automated refraction in patients before 40 year-old.