998 resultados para complete lower denture
Resumo:
Objective: The prevalence of wearing and fracture of complete dentures was evaluated among edentulous patients treated in two dental schools in Brazil. Background: Acceptance and wearing of complete dentures are related to adaptive behaviour of edentulous patients. However, one reason that could interfere with the wearing dentures is their potential to fracture, which is still a common complication in denture rehabilitation practice. Material and methods: Two hundred and twenty-four edentulous patients rehabilitated with complete dentures from 2000 to 2005 in Araçatuba and Araraquara Dental School, University of State of São Paulo, were assessed in 2006 and 2007 to answer a questionnaire about wearing and fracture of their dentures. Statistical analysis were performed using Epi Info software and chi-squared test to compare maxillary and mandibular data (α = 0.05). Results: Almost 26% of the patients did not wear their dentures, and among the remainder, the majority wore the maxillary denture. About 30% of the dentures were fractured, with higher prevalence in the maxillary arch (p = 0.003). Conclusions: Discontinuation of wearing dentures was quite high, especially considering the treatment which was carried out in university clinics. Prevalence of fractures was also high, greater for the maxillary denture, and was one of the main reasons for non-wearing of complete dentures. © 2011 The Gerodontology Society and John Wiley & Sons A/S.
Resumo:
The aim of this study was to assess the electrical activity of the masseter and anterior temporal muscles in patients with severe bone resorption, with complete dentures worn for over ten years, and five months after having new dentures put in place. The RDC questionnaire was applied to twelve asymptomatic patients, before and five months after new dentures were put in place. The electrical activity recordings were made in the mandibular position at rest, and during maximum tooth clenching. The electrical activity of the masseter and anterior temporal muscles in the position at rest presented no statistically significant difference after five months of wearing the new complete dentures. Electrical activity during tooth clenching exhibited a statistically significant reduction only in the right temporal muscle. A period longer than five months of wearing the new complete dentures is required for adaptation and the acquisition of functional capacity.
Resumo:
The signs and symptoms of temporomandibular dysfunction (TMD) may contribute to reduce bite force and muscular activity. The aims of this study were to compare bite force in complete denture wearers with TMD (TMD group) and without TMD (healthy group).The TMD group consisted of 9 individuals, who had worn a maxillary and a mandibular complete removable denture for more than 10 years. The healthy group consisted of 9 participants who wore dentures and had satisfactory interocclusal and maxillomandibular relationship. Helkimo Index was used to analyze the dysfunction level. Maximum bite force was measured using a digital dynamometer with capacity of 100 kgf and adapted to oral conditions.The TMD group presented smaller mean bite force values than the healthy group, though without statistical significance (p>0.05). This outcome suggests that the TMD signs and symptoms and the structural conditions of the dentures did not affect the maximal bite force of complete denture wearers.
Resumo:
The use of denture is known to increase the carriage of Candida in healthy patients, and the proliferation of Candida albicans strains can be associated with denture-induced stomatitis. The aim of this study was to evaluate the use of vinegar as an antimicrobial agent for control of Candida spp. in complete upper denture wearers. Fifty-five patients were submitted to a detailed clinical interview and oral clinical examination, and were instructed to keep their dentures immersed in a 10% vinegar solution ( pH less than 3) overnight for 45 days. Before and after the experimental period, saliva samples were collected for detection of Candida, counting of cfu/mL and identification of species by phenotypical tests ( germ tube formation, chlamidoconidia production, and carbohydrate fermentation and assimilation). The results were analyzed using Spearman's correlation and Student's t-test (p=0.05). Candida yeasts were present in 87.3% of saliva samples before the treatment. A significant reduction was verified in CFU/mL counts of Candida after treatment. A positive correlation between Candida and denture stomatitis was verified, since the decrease of cfu/mL counts was correlated with a reduction in cases of denture stomatitis. Although it was not able to eliminate C. albicans, the immersion of the complete denture in 10% vinegar solution, during the night, reduced the amounts (cfu/mL) of Candida spp. in the saliva and the presence of denture stomatitis in the studied patients.
Resumo:
The technique presented in this article presents a protocol for treatment that reduces the time required for the fabrication and placement of an implant supported prosthesis. It also offers improved patient comfort at a lower cost when compared to conventional technology.
Resumo:
Purpose: The objective of this study was to evaluate the stress on the cortical bone around single body dental implants supporting mandibular complete fixed denture with rigid (Neopronto System-Neodent) or semirigid splinting system (Barra Distal System-Neodent). Methods and Materials: Stress levels on several system components were analyzed through finite element analysis. Focusing on stress concentration at cortical bone around single body dental implants supporting mandibular complete fixed dentures with rigid ( Neopronto System-Neodent) or semirigid splinting system ( Barra Distal System-Neodent), after axial and oblique occlusal loading simulation, applied in the last cantilever element. Results: The results showed that semirigid implant splinting generated lower von Mises stress in the cortical bone under axial loading. Rigid implant splinting generated higher von Mises stress in the cortical bone under oblique loading. Conclusion: It was concluded that the use of a semirigid system for rehabilitation of edentulous mandibles by means of immediate implant-supported fixed complete denture is recommended, because it reduces stress concentration in the cortical bone. As a consequence, bone level is better preserved, and implant survival is improved. Nevertheless, for both situations the cortical bone integrity was protected, because the maximum stress level findings were lower than those pointed in the literature as being harmful. The maximum stress limit for cortical bone (167 MPa) represents the threshold between plastic and elastic state for a given material. Because any force is applied to an object, and there is no deformation, we can conclude that the elastic threshold was not surpassed, keeping its structural integrity. If the force is higher than the plastic threshold, the object will suffer permanent deformation. In cortical bone, this represents the beginning of bone resorption and/or remodeling processes, which, according to our simulated loading, would not occur. ( Implant Dent 2010; 19:39-49)
Resumo:
This article is the first known case report of Fraser syndrome in the dental literature. Its purpose was to present the clinical manifestations, oral findings, and dental treatment of a 14-year, 10-month-old female patient. Fraser syndrome is a rare recessive autosomal genetic disorder characterized by multisystemic malformation, usually comprising cryptophthalmos, syndactyly, and renal defects. The child presented with: (1) hydrocephaly; (2) face asymmetry; (3) low-inserted ears; (4) flat nose bridge; (5) cryptophthalmos; (6) bilateral absence of eyeballs; (7) hypertelorism; (8) syndactyly on the left fingers and toes; (9) skeletal defects; and (10) lower limb asymmetry. The intraoral examination revealed: (1) complete primary denture; (2) malocclusion; (3) tooth crowding; (4) ogival palate; (5) normal labial frena; (6) absence of lingual frenum (not compromising the tongue movements); (7) parched lips; (8) supragingival calculus adhered to all tooth surfaces; and (9) moderate gingivitis. The dental treatment consisted of periodic monitoring of the patient's oral health status and supragingival scaling associated with topical applications of 0.12% chlorhexidine digluconate gel at 2-week intervals to reduce gingivitis.
Resumo:
Purpose: To evaluate the effect of oral rehabilitation with immediately loaded fixed implant-supported mandibular prostheses on chewing and swallowing in elderly individuals. Materials and Methods: Fifteen completely edentulous patients aged more than 60 years (10 women and rive men), wearing removable dentures in both arches, had a mandibular denture replaced by an implant-supported prosthesis. All individuals were evaluated before surgery and again 3, 6, and 18 months later with regard to mastication and swallowing conditions. Examinations entailed an interview, evaluation of tactile sensitivity of the face, and observation of food intake, masticatory type, formations of bolus, and pain during mastication. The swallowing evaluation comprised observation of clinical signs related to the oral and pharyngeal stages of swallowing, as well as the presence of oral residue. The findings of different evaluations before and 3, 6, and 18 months after the surgical-prosthetic procedure were statistically compared by analysis of variance for repeated measurements at a significance level of 5%. Results: The questionnaire revealed a reduction in complaints of masticatory and swallowing disturbances, a decreased need for liquid ingestion, and reduced choking and coughing. Clinical evaluations showed improved oral function and bolus propulsion for both solid and paste-consistency foods; pain during mastication was also resolved. Conclusion: Treatment with mandibular implant-supported dentures had positive effects on the clinical aspects of mastication and swallowing in elderly individuals.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Objective: To evaluate the masticatory efficiency of patients rehabilitated with conventional dentures (CDs) or implant-retained mandibular overdentures. Background: Despite the evident benefits of implants on mastication as assessed by subjective patient-based outcomes, the extent of implant overdenture treatment effect on food comminution is not well established. Materials and methods: A randomised clinical trial was carried out with 29 completely edentulous patients divided into two groups. The first group was rehabilitated with a mandibular overdenture retained by two splinted implants with bar-clip system, while the second group was rehabilitated with a mandibular CD. Both groups also were rehabilitated with maxillary CDs. Masticatory efficiency and patient satisfaction were assessed 3 months after denture insertion. Masticatory efficiency was evaluated through the colorimetric method with the beads as the artificial test-food. Comparisons for masticatory efficiency and patient satisfaction were performed using Student's t-test (alpha = 0.05). Results: No significant statistical difference was found for masticatory efficiency (p = 0.198). Patient overall satisfaction was significantly higher for the mandibular overdenture (p < 0.001). In addition, mandibular overdenture patients were significantly more satisfied with chewing experience (p < 0.05) and retention of the lower denture (p < 0.005). Conclusion: The results of this study suggest that mandibular overdenture significantly improves chewing experience, although limited effect on masticatory efficiency has been observed.
Resumo:
OBJECTIVES This clinical study measured the dimensional changes of existing lower complete dentures due to the integration of a prefabricated implant bar. Additionally, the impact of this dimensional change on patient satisfaction and oral function was analyzed. METHODS Twenty edentulous patients (10 men/10 women; aged 65.9 ± 11.8 years) received two interforaminal implants. Subsequent to surgery, a chair side adapted, prefabricated bar (SFI Bar(®), C+M, Biel, Switzerland) was inserted, and the matrix was polymerized into the existing lower denture. The change of the denture's lingual dimension was recorded by means of a bicolored, silicone denture duplicate that was sectioned in the oro-vestibular direction in the regions of the symphysis (S) and the implants (I-left, I-right). On the sections, the dimensional increase was measured using a light microscope. Six months after bar insertion, patients answered a standardized questionnaire. RESULTS All dentures exhibited increased lingual volume, more extensively at S than at I (P = 0.001). At S, the median diagonal size of the denture was doubled (+4.33 mm), and at I, the median increase was 50% (I-left/-right = +2.66/+2.62 mm). The original denture size influenced the volume increase (P = 0.024): smaller dentures led to a larger increase. The amount of denture increase did not have negative impact on either self-perceived oral function or patient satisfaction. Approximately, 95% of the patients were satisfied with the treatment results. CONCLUSIONS The lingual size of a lower denture was enlarged by the integration of a prefabricated bar without any negative side effects. Thus, this attachment system is suitable to convert an existing full denture into an implant-supported overdenture.
Resumo:
Introduction: The original and modified Wells score are widely used prediction rules for pre-test probability assessment of deep vein thrombosis (DVT). The objective of this study was to compare the predictive performance of both Wells scores in unselected patients with clinical suspicion of DVT.Methods: Consecutive inpatients and outpatients with a clinical suspicion of DVT were prospectively enrolled. Pre-test DVT probability (low/intermediate/high) was determined using both scores. Patients with a non-high probability based on the original Wells score underwent D-dimers measurement. Patients with D-dimers <500 mu g/L did not undergo further testing, and treatment was withheld. All others underwent complete lower limb compression ultrasound, and those diagnosed with DVT were anticoagulated. The primary study outcome was objectively confirmed symptomatic venous thromboembolism within 3 months of enrollment.Results: 298 patients with suspected DVT were included. Of these, 82 (27.5%) had DVT, and 46 of them were proximal. Compared to the modified score, the original Wells score classified a higher proportion of patients as low-risk (53 vs 48%; p<0.01) and a lower proportion as high-risk (17 vs 15%; p=0.02); the prevalence of proximal DVT in each category was similar with both scores (7-8% low, 16-19% intermediate, 36-37% high). The area under the receiver operating characteristic curve regarding proximal DVT detection was similar for both scores, but they both performed poorly in predicting isolated distal DVT and DVT in inpatients.Conclusion: The study demonstrates that both Wells scores perform equally well in proximal DVT pre-test probability prediction. Neither score appears to be particularly useful in hospitalized patients and those with isolated distal DVT. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
It has been suggested that there are no gender effects on esophageal motility. However, in previous studies the subjects did not perform multiple swallows and the quantitative features of esophageal contractions were not evaluated. In order to investigate the gender effects on esophageal motility we studied 40 healthy normal volunteers, 20 men aged 37 ± 15 years (mean ± SD), and 20 women aged 38 ± 14 years. We used the manometric method with an eight-lumen polyvinyl catheter and continuous perfusion. The upper and lower esophageal sphincter pressures were measured by the rapid pull-through method. With the catheter positioned with one lumen opening in the lower esophageal sphincter, and the others at 5, 10 and 15 cm above the sphincter, ten swallows of a 5-ml water bolus alternated with ten dry swallows were performed. Statistical analysis was done by the Student t-test and Mann-Whitney test. Gender differences (P<0.05) were observed for wet swallows in the duration of contractions 5 cm above the lower esophageal sphincter (men: 3.7 ± 0.2 s, women: 4.5 ± 0.3 s, mean ± SEM), and in the velocity of contractions from 15 to 10 cm above the lower esophageal sphincter (men: 4.7 ± 0.3 cm/s, women: 3.5 ± 0.2 cm/s). There was no difference (P>0.05) in sphincter pressure, duration and percentage of complete lower esophageal sphincter relaxation, amplitude of contractions, or in the number of failed, multipeaked and synchronous contractions. We conclude that gender may cause some differences in esophageal motility which, though of no clinical significance, should be taken into consideration when interpreting esophageal motility tests.