Space requirement of a prefabricated bar on two interforaminal implants: a prospective clinical study


Autoria(s): Albrecht, Dominic; Ramierez, Ami; Kremer Hovinga, Urs; Katsoulis, Joannis; Mericske, Regina; Enkling, Norbert
Data(s)

01/02/2015

Resumo

OBJECTIVES This clinical study measured the dimensional changes of existing lower complete dentures due to the integration of a prefabricated implant bar. Additionally, the impact of this dimensional change on patient satisfaction and oral function was analyzed. METHODS Twenty edentulous patients (10 men/10 women; aged 65.9 ± 11.8 years) received two interforaminal implants. Subsequent to surgery, a chair side adapted, prefabricated bar (SFI Bar(®), C+M, Biel, Switzerland) was inserted, and the matrix was polymerized into the existing lower denture. The change of the denture's lingual dimension was recorded by means of a bicolored, silicone denture duplicate that was sectioned in the oro-vestibular direction in the regions of the symphysis (S) and the implants (I-left, I-right). On the sections, the dimensional increase was measured using a light microscope. Six months after bar insertion, patients answered a standardized questionnaire. RESULTS All dentures exhibited increased lingual volume, more extensively at S than at I (P = 0.001). At S, the median diagonal size of the denture was doubled (+4.33 mm), and at I, the median increase was 50% (I-left/-right = +2.66/+2.62 mm). The original denture size influenced the volume increase (P = 0.024): smaller dentures led to a larger increase. The amount of denture increase did not have negative impact on either self-perceived oral function or patient satisfaction. Approximately, 95% of the patients were satisfied with the treatment results. CONCLUSIONS The lingual size of a lower denture was enlarged by the integration of a prefabricated bar without any negative side effects. Thus, this attachment system is suitable to convert an existing full denture into an implant-supported overdenture.

Formato

application/pdf

Identificador

http://boris.unibe.ch/77369/1/Space%20requirement%20of%20a%20prefabricated.pdf

Albrecht, Dominic; Ramierez, Ami; Kremer Hovinga, Urs; Katsoulis, Joannis; Mericske, Regina; Enkling, Norbert (2015). Space requirement of a prefabricated bar on two interforaminal implants: a prospective clinical study. Clinical oral implants research, 26(2), pp. 143-148. Wiley-Blackwell 10.1111/clr.12304 <http://dx.doi.org/10.1111/clr.12304>

doi:10.7892/boris.77369

info:doi:10.1111/clr.12304

info:pmid:25069867

urn:issn:0905-7161

Idioma(s)

eng

Publicador

Wiley-Blackwell

Relação

http://boris.unibe.ch/77369/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Albrecht, Dominic; Ramierez, Ami; Kremer Hovinga, Urs; Katsoulis, Joannis; Mericske, Regina; Enkling, Norbert (2015). Space requirement of a prefabricated bar on two interforaminal implants: a prospective clinical study. Clinical oral implants research, 26(2), pp. 143-148. Wiley-Blackwell 10.1111/clr.12304 <http://dx.doi.org/10.1111/clr.12304>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed