962 resultados para closely spaced antennas
Resumo:
A tunable decoupling and matching network (DMN) for a closely spaced two-element antenna array is presented. The DMN achieves perfect matching for the eigenmodes of the array and thus simultaneously isolates and matches the system ports while keeping the circuit small. Arrays of closely spaced wire and microstrip monopole pairs are used to demonstrate the proposed DMN. It is found that monopoles with different lengths can be used for the design frequency by using this DMN, which increases the design flexibility. This property also enables frequency tuning using the DMN only without having to change the length of the antennas. The proposed DMN uses only one varactor to achieve a tuning range of 18.8% with both return loss and isolation better than 10-dB when the spacing between the antenna is 0.05λ. When the spacing increases to 0.1λ, the simulated tuning range is more than 60%.
Resumo:
A practical method for the design of dual-band decoupling and matching networks (DMN) for two closely spaced antennas using discrete components is presented. The DMN reduces the port-to-port coupling and enhances the diversity of the antennas. By applying the DMN, the radiation efficiency can also be improved when one port is fed and the other port is match terminated. The proposed DMN works at two frequencies simultaneously without the need for any switch. As a proof of concept, a dual-band DMN for a pair of monopoles spaced 0.05λ apart is designed. The measured return loss and port isolation exceed 10 dB from 1.71 GHz to 1.76 GHz and from 2.27 GHz to 2.32 GHz.
Resumo:
A method for prediction of the radiation pattern of N strongly coupled antennas with mismatched sources is presented. The method facilitates fast and accurate design of compact arrays. The prediction is based on the measured N-port S parameters of the coupled antennas and the N active element patterns measured in a 50 ω environment. By introducing equivalent power sources, the radiation pattern with excitation by sources with arbitrary impedances and various decoupling and matching networks (DMN) can be accurately predicted without the need for additional measurements. Two experiments were carried out for verification: pattern prediction for parasitic antennas with different loads and for antennas with DMN. The difference between measured and predicted patterns was within 1 to 2 dB.
Resumo:
When crest-fixed thin trapezoidal steel cladding with closely spaced ribs is subjected to wind uplift/suction forces, local dimpling or pull-through failures occur prematurely at their screw connections because of the large stress concentrations in the cladding under the screw heads. Currently, the design of crest-fixed profiled steel cladding is mainly based on time consuming and expensive laboratory tests due to the lack of adequate design rules. In this research, a shell finite element model of crest-fixed trapezoidal steel cladding with closely spaced ribs was developed and validated using experimental results. The finite element model included a recently developed splitting criterion and other advanced features including geometric imperfections, buckling effects, contact modelling and hyperelastic behaviour of neoprene washers, and was used in a detailed parametric study to develop suitable design formulae for local failures. This paper presents the details of the finite element analyses, large scale experiments and their results including the new wind uplift design strength formulae for trapezoidal steel cladding with closely spaced ribs. The new design formulae can be used to achieve both safe and optimised solutions.
Resumo:
By using small scale model tests, the interference effect on the ultimate bearing capacity of two closely spaced strip footings, placed on the surface of dry sand, was investigated. At any time, the footings were assumed to (1) carry exactly the same magnitude of load; and (2) settle to the same extent. No tilt of the footing was allowed. The effect of clear spacing (s) between two footings was explicitly studied. An interference of footings leads to a significant increase in their bearing capacity; the interference effect becomes even more substantial with an increase in the relative density of sand. The bearing capacity attains a peak magnitude at a certain (critical) spacing between two footings. The experimental observations presented in this technical note were similar to those given by different available theories. However, in a quantitative sense, the difference between the experiments and theories was seen to be still significant and it emphasizes the need of doing a further rigorous analysis in which the effect of stress level on the shear strength parameters of soil mass can be incorporated properly.
Resumo:
A filter cloth with 182 holes per 10−4 m2 has been used to generate air bubbles both in pure water and in aqueous solutions of electrolytes and non-electrolytes at various air flow rates. Potassium bromide and ammonium perchlorate were the electrolytes used, while the non-electrolytes were isopropanol, urea and glycerol. Bubble diameters and their size distribution were measured from photographs. The role of solutes in affecting bubble sizes and their distribution compared to that of pure water is discussed in the light of a hypothesis. This hypothesis assumes that if the final bubble diameter is less than the inter-orifice distance, then bubbles do not coalesce; on the other hand, if it is greater, then coalescence occurs when tf greater-or-equal, slantedti+ts, but does not occur when t
Resumo:
The vertical uplift resistance of two closely spaced horizontal strip plate anchors has been investigated by using lower and upper bound theorems of the limit analysis in combination with finite elements and linear optimization. The interference effect on uplift resistance of the two anchors is evaluated in terms of a nondimensional efficiency factor (eta(c)). The variation of eta(c) with changes in the clear spacing (S) between the two anchors has been established for different combinations of embedment ratio (H/B) and angle of internal friction of the soil (phi). An interference of the anchors leads to a continuous reduction in uplift resistance with a decrease in spacing between the anchors. The uplift resistance becomes a minimum when the two anchors are placed next to each other without any gap. The critical spacing (S-cr) between the two anchors required to eliminate the interference effect increases with an increase in the values of both H/B and phi. The value of S-cr was found to lie approximately in the range 0.65B-1.5B with H/B = 1 and 11B-14B with H/B = 7 for phi varying from 0 degrees to 30 degrees.
Resumo:
Effects of some factors on the performance of our Kalman filter in discrimination of closely spaced overlapping signals were investigated. The resolution power of the filter for overlapping lines can be strengthened by reduction of the step size in scans. The minimum peak separation of two lines which the Kalman filter can effectively handle generally equals two to three times the step size in scans. Significant difference between the profiles of the analysis and interfering lines and multiple lines from matrix in the spectral window of the analysis line are very helpful for the Kalman filter to discern closely spaced analysis and interfering signals correctly, which allow the filter well to resolve the line pair with very small peak distance or even the entirely coincident lines.
Resumo:
"Contract AF33(616)-3220 Project No. 6(7-4600) Task 40572 Wright Air Development Center"
Resumo:
"February 1973."
Resumo:
Mode of access: Internet.
Resumo:
L’attività di ricerca contenuta in questa tesi si è concentrata nello sviluppo e nell’implementazione di tecniche per la co-simulazione e il co-progetto non lineare/elettromagnetico di sistemi wireless non convenzionali. Questo lavoro presenta un metodo rigoroso per considerare le interazioni tra due sistemi posti sia in condizioni di campo vicino che in condizioni di campo lontano. In sostanza, gli effetti del sistema trasmittente sono rappresentati da un generatore equivalente di Norton posto in parallelo all’antenna del sistema ricevente, calcolato per mezzo del teorema di reciprocità e del teorema di equivalenza. La correttezza del metodo è stata verificata per mezzo di simulazioni e misure, concordi tra loro. La stessa teoria, ampliata con l’introduzione degli effetti di scattering, è stata usata per valutare una condizione analoga, dove l’elemento trasmittente coincide con quello ricevente (DIE) contenuto all’interno di una struttura metallica (package). I risultati sono stati confrontati con i medesimi ottenibili tramite tecniche FEM e FDTD/FIT, che richiedono tempi di simulazione maggiori di un ordine di grandezza. Grazie ai metodi di co-simulazione non lineari/EM sopra esposti, è stato progettato e verificato un sistema di localizzazione e identificazione di oggetti taggati posti in ambiente indoor. Questo è stato ottenuto dotando il sistema di lettura, denominato RID (Remotely Identify and Detect), di funzioni di scansione angolare e della tecnica di RADAR mono-pulse. Il sistema sperimentale, creato con dispositivi low cost, opera a 2.5 GHz ed ha le dimensioni paragonabili ad un normale PDA. E’ stato sperimentata la capacità del RID di localizzare, in scenari indoor, oggetti statici e in movimento.