1000 resultados para circular section
Resumo:
A proposed adequation of NBR 6118, Item 7.4, related to shear strength of reinforced concrete beams is presented with aims to application on circular cross-section. The actual expressions are most suitable to rectangular cross-section and some misleading occurs when applied to circular sections at determination of VRd2, Vc and Vsw, as consequence of bw (beam width) and d (effective depth) definitions as well as the real effectiveness of circular stirrups. The proposed adequation is based on extensive bibliographic review and practical experience with a great number of infrastructure elements, such as anchored retaining pile walls, where the use of circular reinforced concrete members is frequent.
Resumo:
Pós-graduação em Engenharia Civil - FEIS
Resumo:
In this paper results of tests on 32 concrete-filled steel tubular columns under axial load are reported. The test parameters were the concrete compressive strength, the column slenderness (L/D) and the wall thickness (t). The test results were compared with predictions from the codes NBR 8800:2008 and EN 1994-1-1:2004 (EC4). The columns were 3, 5, 7 and 10 length to diameter ratios (L/D) and were tested with 30MPa, 60MPa, 80MPa and 100MPa concrete compressive strengths. The results of ultimate strength predicted by codes showed good agreement with experimental results. The results of NBR 8800 code were the most conservative and the EC4 showed the best results, in mean, but it was not conservative for usual concrete-filled short columns.
Resumo:
Foi realizado um estudo sobre o efeito do tipo de fluidos na transferência de calor. Pretende-se determinar a influência da concentração da solução de Goma de Xantano, do número de Reynolds, do número de Weissenberg, da temperatura e do tempo de escoamento no coeficiente de transferência de calor, jH. O estudo da transferência de calor foi feito num permutador de tubos duplos concêntricos. Já o estudo da reologia foi realizado num reómetro. Na caracterização reológica das soluções de XG, a viscosidade aumenta com a concentração das soluções, diminui para taxas de deformação crescentes e com o aumento da temperatura para ambas as soluções. Os dados mostram um aumento da intensidade da pseudoplasticidade com a concentração do polímero, sendo os valores representados pelo modelo de Sisco. A degradação da solução de 0,20% de goma de xantano a 25 ºC, com o escoamento, é muito acelerada. Os resultados dos ensaios apresentam uma diminuição da viscosidade de 9,4% a 22,9%, para tempos de escoamento de 12 a 47 horas, respectivamente. Num escoamento turbulento em conduta de secção circular constante os resultados mostram uma redução de arrasto total de 18 para 33%. Para a solução de 0,10 % de XG, verifica-se um aumento do calor transferido de 115% e de 130%, quando a temperatura aumenta de 25 ºC para 36 ºC, respectivamente. A água apresenta valores de calor transferido superiores, cerca de 170%, aos da solução de 0,1 %XG. O factor de correlação empírico de Colbourn (jH), utilizado neste trabalho apresenta valores de acordo com a relação de Cho and Hartnett (1985): jH<2/f. Quando o caudal do fluido quente aumenta verifica-se uma diminuição do factor jH. Em relação ao tempo de escoamento verifica-se uma diminuição de cerca de 70% do coeficiente de transferência de calor ao fim de 47 horas. Finalmente verificamos uma diminuição do factor de transferência de calor com o aumento da temperatura do fluido quente, para ambas as concentrações de goma de xantano. Para as soluções de 0,10 e 0,20% de XG essa diminuição variou entre 38 e 15% e entre 34 e 3%, respectivamente.
Resumo:
Dissertação de mestrado integrado em Engenharia Mecânica
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This paper presents a computational fluid dynamics (CFD) application about the axial fan design used in an agricultural spraying system with a theoretical and experimental analysis of comparative results between the characteristic curves of a fan for several rotations and numerical results for the influence of blade attack angle variation and optimization of the spraying system, both for a same rotation. Flow was considered three-dimensional, turbulent, isothermal, viscous and non-compressible in a steady state, disregarding any influence of the gravity field. The average turbulent field was obtained from the application of time average where the turbulence model required for closing the set of equations was the k-E model. Resolution of all connected phenomena was achieved with the help of a fluid dynamics computer, CFX, which uses the finite volumes technique as a numerical method. In order to validate the theoretical analysis, an experiment was conducted in a circular section of a horizontal wind tunnel, using a Pitot tube for pressure readings. The main results demonstrate that the methodology used, based on CFD techniques, is able to reproduce the phenomenological behavior of an axial fan in a spraying system because results were very reliable and similar to experimentally measured ones.
Resumo:
Fracture mechanics plays an important role in the material science, structure design and industrial production due to the failure of materials and structures are paid high attention in human activities. This dissertation, concentrates on some of the fractural aspects of shaft and composite which have being increasingly used in modern structures, consists four chapters within two parts. Chapters 1 to 4 are included in part 1. In the first chapter, the basic knowledge about the stress and displacement fields in the vicinity of a crack tip is introduced. A review involves the general methods of calculating stress intensity factors are presented. In Chapter 2, two simple engineering methods for a fast and close approximation of stress intensity factors of cracked or notched beams under tension, bending moment, shear force, as well as torque are presented. New formulae for calculating the stress intensity factors are proposed. One of the methods named Section Method is improved and applied to the three dimensional analysis of cracked circular section for calculating stress intensity factors. The comparisons between the present results and the solutions calculated by ABAQUS for single mode and mixed mode are studied. In chapter 3, fracture criteria for a crack subjected to mixed mode loading of two-dimension and three-dimension are reviewed. The crack extension angle for single mode and mixed mode, and the critical loading domain obtained by SEDF and MTS are compared. The effects of the crack depth and the applied force ratio on the crack propagation angle and the critical loading are investigated. Three different methods calculating the crack initiation angle for three-dimension analysis of various crack depth and crack position are compared. It should be noted that the stress intensity factors used in the criteria are calculated in section 2.1.
Resumo:
Las transiciones en guía de onda son las estructuras utilizadas en microondas para transferir y adaptar la señal que viaja en un determinado sistema de transmisión (por ejemplo, un cable coaxial) a otro sistema de transmisión o a un sistema radiante (por ejemplo, una antena de bocina). Los dos sistemas de transmisión entre los que la transición adapta la señal pueden ser distintos o del mismo tipo pero con alguna de sus dimensiones diferente. Existen diferentes transiciones de guía de onda que dependiendo de su utilidad son diseñadas y construidas con diferentes secciones: circular, rectangular, elíptica o incluso combinaciones de éstas. No es necesario que la sección de la guía presente una forma geométrica conocida pero los estándares que se van a seguir hacen referencia en concreto a secciones rectangulares y circulares. En el trabajo que aquí se desarrolla se pretende optimizar por medio de simulaciones paramétricas una transición entre cable coaxial con conector tipo K y una guía de onda de sección circular que sigue el estándar presentado por Flann, Millitech y Antarfs para la banda WR34. La transición que va a ser objeto de este estudio se denomina transición tapered o transición conformada. Este tipo de transiciones se caracterizan por variar una de sus dimensiones progresivamente hasta llegar al tamaño definido en el estándar correspondiente. La manera de realizar la optimización de la transición se basará en el estudio del parámetro S11 que presente la estructura a lo largo de la banda de trabajo. Ya que se sigue el estándar WR34 la banda de trabajo que éste comprende va de 21,7 a 33 GHz. Se pretende conseguir que la respuesta del parámetro S11 se encuentre por debajo de -20 dB en la banda de WR34 como resultado del diseño para poder contar de esta manera con una buena adaptación. Finalmente se propondrá un criterio a seguir para optimizar este tipo de transiciones siguiendo el objetivo de mejor adaptación teniendo en cuenta el impacto de cada tramo sobre el rango de frecuencias en el que influye y se presentarán las características finales que presenta la transición bajo estudio. En este documento se introduce de manera breve la utilidad de los transformadores de impedancias lambda cuartos en líneas de transmisión, el estado del arte de las diferentes técnicas para su diseño, y la propuesta de diseño y caracterización objeto del presente trabajo. Posteriormente, se presenta el caso de estudio para el diseño de la transición para ser integrada a una bocina de choke. Luego, se introduce el marco teórico del trabajo presentando algunos ejemplos ilustrativos de tramos de guía de onda rectangular y guía de onda circular, introduciendo adaptadores de λ/4 en simulaciones. A continuación, se explica la implementación del modelo bajo estudio en CST (Computer Simulation Technology) Studio Suite. Finalmente se presenta la discusión de los resultados obtenidos, las conclusiones y líneas futuras de trabajo. ABSTRACT. Waveguide transitions are structures used in microwave in order to transfer and adapt the signal that travels from a certain transmission system (e.g. coaxial cable) to other transmission system or to a radiant system (e.g. horn antenna). Both transmission systems between which the transition adapts the signal can be different or from the same type, but with differences in some of their dimensions. There are different waveguide transitions that, depending on their utility, are designed and constructed in different sections: circular, rectangular, elliptic or combinations of the former. The section of the guide does not have to have a known geometric shape, although the standards to be followed in this thesis apply to rectangular and circular sections. In the work here presented, we aim to optimize by means of parametric simulations, a transition between a coaxial cable with a K-type connector and a waveguide with circular section following the standard presented by Flann, Millitech y Antarfs for the band WR34. The transition studied is called tapered transition, which is characterized by the progressive variation of its dimensions, until reaching the defined size of the corresponding standard. The way of optimizing the transition will be based in the study of the parameter S11 presented by the structure along the bandwidth. Since the standard used is the WR34, the bandwidth can be defined from 21.7 up to 33 GHz. It is aimed that the response of the S11 parameter be lower equal than -20dB in the frequency band under study according to the design in order to be well matched. Finally, a criterion to follow is proposed in order to optimize these transitions type, following the better-match objective. That will be done taking into account the impact of each section on the frequency range in which influences and the final characteristics of the studied transition will be presented. In this document, it is briefly introduced the utility of quarter-wave impedance transformers in transmission lines, the state-of-art of the different techniques for their design, and the proposal of design and characterization aimed with this work. Afterwards, the study case for the design of the transition to be integrated with a choke horn antenna will be presented. Later, the theoretical frame work is introduced, giving some illustrative examples of rectangular and circular waveguide sections, and also introducing λ/4 adaptors in the simulations. Subsequently, the implementation of the model under study in CST (Computer Simulation Technology) Studio Suite will be explained. Finally, the discussion of the results, conclusion and future lines of the work are presented.
Resumo:
In this paper a previously developed theoretical model of the measurement process performed by a transit-time ultrasonic anemometer is applied to a fluid flowing through a circular section pipe. This model considers the influence of the shift of the acoustic pulse trajectory from straight propagation due to the flow on the measured speed. The aim of this work is to estimate the errors induced in the measured velocity by the shift of the acoustic pulse trajectory. Using different duct’s flow models, laminar and turbulent regimes have been analyzed. The results show that neglecting the effect of shift of the acoustic pulse trajectory leads to flow rate measurement underestimation.
Resumo:
The thesis presents an experimentally validated modelling study of the flow of combustion air in an industrial radiant tube burner (RTB). The RTB is used typically in industrial heat treating furnaces. The work has been initiated because of the need for improvements in burner lifetime and performance which are related to the fluid mechanics of the com busting flow, and a fundamental understanding of this is therefore necessary. To achieve this, a detailed three-dimensional Computational Fluid Dynamics (CFD) model has been used, validated with experimental air flow, temperature and flue gas measurements. Initially, the work programme is presented and the theory behind RTB design and operation in addition to the theory behind swirling flows and methane combustion. NOx reduction techniques are discussed and numerical modelling of combusting flows is detailed in this section. The importance of turbulence, radiation and combustion modelling is highlighted, as well as the numerical schemes that incorporate discretization, finite volume theory and convergence. The study first focuses on the combustion air flow and its delivery to the combustion zone. An isothermal computational model was developed to allow the examination of the flow characteristics as it enters the burner and progresses through the various sections prior to the discharge face in the combustion area. Important features identified include the air recuperator swirler coil, the step ring, the primary/secondary air splitting flame tube and the fuel nozzle. It was revealed that the effectiveness of the air recuperator swirler is significantly compromised by the need for a generous assembly tolerance. Also, there is a substantial circumferential flow maldistribution introduced by the swirier, but that this is effectively removed by the positioning of a ring constriction in the downstream passage. Computations using the k-ε turbulence model show good agreement with experimentally measured velocity profiles in the combustion zone and proved the use of the modelling strategy prior to the combustion study. Reasonable mesh independence was obtained with 200,000 nodes. Agreement was poorer with the RNG k-ε and Reynolds Stress models. The study continues to address the combustion process itself and the heat transfer process internal to the RTB. A series of combustion and radiation model configurations were developed and the optimum combination of the Eddy Dissipation (ED) combustion model and the Discrete Transfer (DT) radiation model was used successfully to validate a burner experimental test. The previously cold flow validated k-ε turbulence model was used and reasonable mesh independence was obtained with 300,000 nodes. The combination showed good agreement with temperature measurements in the inner and outer walls of the burner, as well as with flue gas composition measured at the exhaust. The inner tube wall temperature predictions validated the experimental measurements in the largest portion of the thermocouple locations, highlighting a small flame bias to one side, although the model slightly over predicts the temperatures towards the downstream end of the inner tube. NOx emissions were initially over predicted, however, the use of a combustion flame temperature limiting subroutine allowed convergence to the experimental value of 451 ppmv. With the validated model, the effectiveness of certain RTB features identified previously is analysed, and an analysis of the energy transfers throughout the burner is presented, to identify the dominant mechanisms in each region. The optimum turbulence-combustion-radiation model selection was then the baseline for further model development. One of these models, an eccentrically positioned flame tube model highlights the failure mode of the RTB during long term operation. Other models were developed to address NOx reduction and improvement of the flame profile in the burner combustion zone. These included a modified fuel nozzle design, with 12 circular section fuel ports, which demonstrates a longer and more symmetric flame, although with limited success in NOx reduction. In addition, a zero bypass swirler coil model was developed that highlights the effect of the stronger swirling combustion flow. A reduced diameter and a 20 mm forward displaced flame tube model shows limited success in NOx reduction; although the latter demonstrated improvements in the discharge face heat distribution and improvements in the flame symmetry. Finally, Flue Gas Recirculation (FGR) modelling attempts indicate the difficulty of the application of this NOx reduction technique in the Wellman RTB. Recommendations for further work are made that include design mitigations for the fuel nozzle and further burner modelling is suggested to improve computational validation. The introduction of fuel staging is proposed, as well as a modification in the inner tube to enhance the effect of FGR.
Resumo:
We extend application of our lowest-order perturbative approach (in electron-electron correlation) for analysis of photo-double-ionization (PDI) of He [A.Y. Istomin et al., J. Phys. B 35, L543 (2002)] to excess energies up to 450 eV and to analysis of circular dichroism. We find that account of electron correlation in the final state to first order provides predictions for the triply differential cross section and circular dichroism that are in reasonable agreement with absolute data for excess energies up to 80 eV. For an excess energy of 450 eV, account of electron correlation in both initial and final states is necessary and the predicted triply differential cross sections are in agreement with absolute data only for large mutual ejection angles. We find that at excess energies of a few tens of eV, the PDI is dominated by the "virtual" knock-out mechanism, while the "direct" (on-shell) knock-out process gives only small contributions for large mutual ejection angles. As a result, we conclude that the circular dichroism effect at these energies originates from the nonzero electron Coulomb phase shifts.
Resumo:
The object of this thesis is to develop a method for calculating the losses developed in steel conductors of circular cross-section and at temperatures below 100oC, by the direct passage of a sinusoidally alternating current. Three cases are considered. 1. Isolated solid or tubular conductor. 2. Concentric arrangement of tube and solid return conductor. 3. Concentric arrangement of two tubes. These cases find applications in process temperature maintenance of pipelines, resistance heating of bars and design of bus-bars. The problems associated with the non-linearity of steel are examined. Resistance heating of bars and methods of surface heating of pipelines are briefly described. Magnetic-linear solutions based on Maxwell's equations are critically examined and conditions under which various formulae apply investigated. The conditions under which a tube is electrically equivalent to a solid conductor and to a semi-infinite plate are derived. Existing solutions for the calculation of losses in isolated steel conductors of circular cross-section are reviewed, evaluated and compared. Two methods of solution are developed for the three cases considered. The first is based on the magnetic-linear solutions and offers an alternative to the available methods which are not universal. The second solution extends the existing B/H step-function approximation method to small diameter conductors and to tubes in isolation or in a concentric arrangement. A comprehensive experimental investigation is presented for cases 1 and 2 above which confirms the validity of the proposed methods of solution. These are further supported by experimental results reported in the literature. Good agreement is obtained between measured and calculated loss values for surface field strengths beyond the linear part of the d.c. magnetisation characteristic. It is also shown that there is a difference in the electrical behaviour of a small diameter conductor or thin tube under resistance or induction heating conditions.
Resumo:
The dynamic plastic response of a simply supported circular plate is analysed. Emphasis is given to the plate behaviour after it has broken free from the supports due to a local material failure. The theoretical rigid plastic analysis predicts various features of the response such as the time to failure, residual kinetic energy and the critical velocity at failure. The residual kinetic energy of the plate could be significant enough to cause secondary impact damage. It is shown that the shape of the plate changes after breaking free from the supports, which is important for forensic investigations. The solution for various cases were proven to be exact in the context of the upper and lower bounds theorems of the theory of plasticity. (C) 2009 Elsevier Ltd. All rights reserved.