In this paper results of tests on 32 concrete-filled steel tubular columns under axial load are reported. The test parameters were the concrete compressive strength, the column slenderness (L/D) and the wall thickness (t). The test results were compared with predictions from the codes NBR 8800:2008 and EN 1994-1-1:2004 (EC4). The columns were 3, 5, 7 and 10 length to diameter ratios (L/D) and were tested with 30MPa, 60MPa, 80MPa and 100MPa concrete compressive strengths. The results of ultimate strength predicted by codes showed good agreement with experimental results. The results of NBR 8800 code were the most conservative and the EC4 showed the best results, in mean, but it was not conservative for usual concrete-filled short columns.

Identificador

Rem: Revista Escola de Minas, v.62, n.1, p.73-85, 2009

0370-4467

http://producao.usp.br/handle/BDPI/17883

http://apps.isiknowledge.com/InboundService.do?Func=Frame&product=WOS&action=retrieve&SrcApp=EndNote&UT=000265856700018&Init=Yes&SrcAuth=ResearchSoft&mode=FullRecord

Idioma(s)

por

Publicador

ESCOLA DE MINAS

Relação

Rem: Revista Escola de Minas

Direitos

closedAccess

Copyright ESCOLA DE MINAS

Palavras-Chave #Concrete-filled columns #circular section #test results #axial load #axial strength #OF-THE-ART #EXPERIMENTAL BEHAVIOR #TUBE COLUMNS #CAPACITY #STRENGTH #Engineering, Civil #Metallurgy & Metallurgical Engineering #Mining & Mineral Processing
Tipo

article

original article

publishedVersion