984 resultados para chromium(VI)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The batch removal of hexavalent chromium (Cr(Vl)) from wastewater under different experimental conditions using economic adsorbents was investigated in this study. These adsorbents were produced from the pyrolysis and activation of the waste tyres (TAC) and from the pyrolysis of sawdust (SPC). The performance of these adsorbents against commercial activated carbon F400 (CAC) has also been carried out. The removal was favoured at low pH, with maximum removal at pH = 2 for all types of carbon. The effects of concentration, temperature and particle size have been reported. All sorbents were found to efficiently remove Cr(VI) from solution. The batch sorption kinetics have been tested for a first-order reversible reaction, a first-order and second-order reaction. The rate constants of adsorption for all these kinetic models have been calculated. The applicability of the Langmuir isotherm for the present system has been tested at different temperatures. The thermodynamic parameters (AGO, K,) obtained indicate the endothermic nature of Cr(Vl) adsorption on TAC, SPC and CAC. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Zero valent iron (ZVI) has been extensively used as a reactive medium for the reduction of Cr(VI) to Cr(III) in reactive permeable barriers. The kinetic rate depends strongly on the superficial oxidation of the iron particles used and the preliminary washing of ZVI increases the rate. The reaction has been primarily modelled using a pseudo-first-order kinetics which is inappropriate for a heterogeneous reaction. We assumed a shrinking particle type model where the kinetic rate is proportional to the available iron surface area, to the initial volume of solution and to the chromium concentration raised to a power ˛ which is the order of the chemical reaction occurring at surface. We assumed α= 2/3 based on the likeness to the shrinking particle models with spherical symmetry. Kinetics studies were performed in order to evaluate the suitability of this approach. The influence of the following parameters was experimentally studied: initial available surface area, chromium concentration, temperature and pH. The assumed order for the reaction was confirmed. In addition, the rate constant was calculated from data obtained in different operating conditions. Digital pictures of iron balls were periodically taken and the image treatment allowed for establishing the time evolution of their size distribution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A comparative systematic study of the CrO2F2 compound has been performed using different conventional ab initio methodologies and density functional procedures. Two points have been analyzed: first, the accuracy of results yielded by each method under study, and second, the computational cost required to reach such results. Weighing up both aspects, density functional theory has been found to be more appropriate than the Hartree-Fock (HF) and the analyzed post-HF methods. Hence, the structural characterization and spectroscopic elucidation of the full CrO2X2 series (X=F,Cl,Br,I) has been done at this level of theory. Emphasis has been given to the unknown CrO2I2 species, and specially to the UV/visible spectra of all four compounds. Furthermore, a topological analysis in terms of charge density distributions has revealed why the valence shell electron pair repulsion model fails in predicting the molecular shape of such CrO2X2 complexes

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chromium (VI) removal and its reduction to chromium (III) from aqueous solution by untreated and heat-treated Quercus cerris and heat-treated Quercus suber black agglomerate cork granules was investigated. Initial screening studies revealed that among the sorbents tested, untreated Q. cerris and Q. suber black agglomerate are the most efficient in the removal of Cr(VI) ions and were selected for adsorption essays. Heat treatment adversely affected chromium adsorption and chromium (VI) reduction in Q. cerris cork. The highest metal uptake was found at pH 3.0 for Q. cerris and pH 2.0 for black agglomerate. The experimental data fitted the Langmuir model and the calculated qmax was 22.98 mg/g in black agglomerate and 21.69 mg/g in untreated Q. cerris cork. The FTIR results indicated that while in black agglomerate, lignin is the sole component responsible for Cr(VI) sorption, and in untreated Q. cerris cork, suberin and polysaccharides also play a significant role on the sorption. The SEM-EDX results imply that chromium has a homogenous distribution within both cork granules. Also, phloemic residues in Q. cerris granules showed higher chromium concentration. The results obtained in this study show that untreated Q. cerris and black agglomerate cork granules can be an effective and economical alternative to more costly materials for the treatment of liquid wastes containing chromium

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cancer du poumon associé à l’exposition au nickel, au chrome VI et au cadmium dans le milieu de travail utilisant deux études populationnelles cas-témoins à Montréal. Au début des années 1990, le nickel, le chrome VI et le cadmium ont été classés en tant qu’agents cancérigènes de classe 1 par le CIRC (Centre International de Recherche sur le Cancer). Cependant, les résultats des études ayant permis la classification de ces métaux n’ont pas toujours été reproduits, et d’importantes questions demeurent quant aux effets de ces métaux à de faibles niveaux d’exposition. Un plus grand nombre de recherches empiriques est donc nécessaire afin de réaffirmer la cancérogénicité de ces agents, et d’identifier les circonstances dans lesquelles ils peuvent être néfastes. L'objectif de cette étude était d'explorer la relation entre l’exposition à un des métaux (soit le nickel, le chrome VI, ou le cadmium) et les risques subséquents de développer un cancer du poumon chez des travailleurs provenant de différents milieux de travail qui sont exposés à ces métaux à de différents degrés. Deux études cas-témoins de base populationnelle menées à Montréal ont fourni les données nécessaires pour examiner la cancérogénicité de ces métaux. La première étude était menée entre 1979 et 1986 chez des hommes âgés de 35 à 70 ans ayant un cancer dans l’un de 19 sites anatomiques de cancer sélectionnés. La seconde étude était menée entre 1996 et 2001 chez des hommes et des femmes âgés de 35 à 75 ans, avec un diagnostic de tumeur maligne au poumon. Dans ces deux études, les cas ont été recensés dans tous les hôpitaux de l'île de Montréal, tandis que les contrôles populationnels appariés par âge et stratifiés par sexe, ont été sélectionnés des listes électorales. Une entrevue avec chaque sujet a permis d'obtenir un historique d'emploi détaillé ainsi que des informations précises sur les facteurs de risques socio-économiques et personnels. Les descriptions de poste ont été évaluées par une équipe d'experts chimistes et hygiénistes afin de déterminer si le sujet a été exposé à chaque agent, et pour mesurer à la fois la concentration et la durée de chaque exposition, ainsi que l’exposition cumulative tout au long de la vie de chaque participant. Pour déterminer si une exposition à l’un des trois métaux en cause était associée à une augmentation de l'incidence du cancer du poumon, des données ont été analysées par régression logistique : des ajustements ont été effectués pour des facteurs de confusion pertinents incluant un historique détaillé du tabagisme. Des mesures catégoriques d'exposition cumulée ont été également analysées, ainsi que la modification des effets par le tabagisme. Les deux études ont été analysées séparément, puis par la suite combinées afin d'augmenter la puissance statistique. Les niveaux d'exposition mesurés dans cette population ne semblaient pas poser un excès de risque de cancer du poumon pour les travailleurs exposés au chrome VI. Cependant, ceux qui ont été exposés au nickel ont subi une augmentation significative du risque, et ce, quel que soit leur niveau d'exposition. Le risque de développer un cancer du poumon suite à une exposition au cadmium était élevé, mais pas de manière significative. Pour chacun des trois métaux, le risque de cancer du poumon était très élevé parmi les non-fumeurs, mais pas parmi les fumeurs. L’effet combiné du tabagisme et de l’exposition aux métaux était compatible avec un excès de risque additif. Cependant, les intervalles de confiance dans cette étude tendaient à être larges, et une faiblesse de puissance statistique peut limiter l’interprétation de certains résultats. Cette étude est unique dans la mesure où elle a fourni des preuves empiriques sur les risques de développer le cancer du poumon liés aux faibles niveaux d’exposition au nickel, au chrome VI, ou au cadmium provenant de divers contextes de travail. Dans la plupart des autres études, la majorité des expositions pertinentes n’ont pas été bien contrôlées. À l'inverse, cette étude a bénéficié de la collecte et de la disponibilité d'information détaillée concernant le tabagisme et d’autres facteurs de risque. Les résultats de cette étude ont d'importantes conséquences pour la santé publique, tant au niveau de la détermination des risques pour les travailleurs actuellement exposés à ces métaux, qu'au niveau de l’évaluation des risques pour la population en général, elle-même exposée à ces métaux par le biais de la pollution et de la fumée de cigarette. Cette analyse contribuera fort probablement à une réévaluation par le CIRC de la cancérogénicité de ces métaux. L'exploration de la relation entre les risques de cancer du poumon et l'exposition au nickel, au chrome VI et au cadmium est donc opportune et pertinente.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A comparative systematic study of the CrO2F2 compound has been performed using different conventional ab initio methodologies and density functional procedures. Two points have been analyzed: first, the accuracy of results yielded by each method under study, and second, the computational cost required to reach such results. Weighing up both aspects, density functional theory has been found to be more appropriate than the Hartree-Fock (HF) and the analyzed post-HF methods. Hence, the structural characterization and spectroscopic elucidation of the full CrO2X2 series (X=F,Cl,Br,I) has been done at this level of theory. Emphasis has been given to the unknown CrO2I2 species, and specially to the UV/visible spectra of all four compounds. Furthermore, a topological analysis in terms of charge density distributions has revealed why the valence shell electron pair repulsion model fails in predicting the molecular shape of such CrO2X2 complexes

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A strain of Staphylococcus isolated by Dr. Fekete at the Sandia National Laboratory toxic metal dumping site in Sandia, New Mexico. has been found to reduce toxic Cr(VI) to the less toxic Cr(IlI) state. We have ascertained the environmental parameters for optimal bacterial growth and Cr(VI) reduction. This knowledge may be employed in a comprehensive bioremediation scheme designed to accelerate natural reparation of that Sandia ecosystem. In addition we have investigated the genetic and enzymatic basis for this Cr(VI) reducing ability. This information may allow us to create more effective bioremediation schemes based on the comprehensive knowledge of enzyme and gene function. Preliminary investigations have been carried out toward this end which may serve as the basis for a more thorough investigation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Titanium(IV) oxide, coated on the surface of silica gel (surface area, 308 m2 g-1; amount of Ti(IV) per gram of modified silica gel, 1.8 x 10(-3) mol), was used to adsorb CrO4(2-) ions from acidic solutions. The exchange capacity increased at lower pH values and was affected to some extent by the acid used. The material was used to preconcentrate Cr(VI) from 0.5 ppm solutions of chromate very efficiently and virtually 100% recovery was achieved in every instance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Screen-printed carbon electrode (SPCE) modified with poly-L-histidine film can be successfully applied for chromium(VI) determination based on its pre-concentration. Optimum adherence and stability of the POIY-L-histidine film was obtained by direct addition of PH solution 1% (w/v) on the electrode surface, followed by heating at 80 degrees C during 5 min. Linear response range, sensitivity and limit of detection were 0. 1-150 [mu mol L-1, 4. 13 LA mu mol L` and 0.046 mu mol L-1. The repeatability of the proposed sensor, evaluated in terms of relative standard deviation, was measured as 3.2% for 10 experiments in 40 mu mol L-1 using the same electrode and 4.0% using screen-printed electrode as disposable sensor, respectively. The voltammetric sensor was applied to determination of Cr(VI) and indirect determination of Cr(III) in wastewater samples previously treated by a leather dyeing industry and the average recovery for these samples was around 97%. (C) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow injection analysis (FIA) procedure for the speciation of Cr(III) and Cr(VI) using the 1,5-diphenylcarbazide (DPC) method is presented. As Cr(III) does not interfere in the Cr(VI) - DPC reaction, both Cr(VI) and total chromium [after the on-line oxidation of Cr(III) by Ce(IV)] are sequentially determined. Cr(III) is obtained by difference. Under the experimental conditions described, the calibration graphs are linear up to 2 μg mh1 of Cr(VI) and 4 μg ml-1 of Cr(III). The detection limits found were 18 ng ml -1 for Cr(VI) and 55 ng ml-1 for Cr(III), at a signal to noise ratio of 3. The common interfering elements in the Cr(VI) - DPC reaction were investigated under dynamic FIA conditions. The FIA method was also compared with the conventional spectrophotometric procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work reports the use of a screen-printed carbon electrode (SPCE) modified by poly-L-histidine film to determine chromium (VI). Stable films can be formed by direct addition of PH solution 1 % (w/v) on the electrode surface, followed by heating at 80°C during 5 min. Calibration curves can be constructed for Cr(VI) from 1.0 × 10-5 mol L-1 to 7.0 × 10-5 mol L-1 Cr (VI) in acetate buffer pH 4 using a preconcentration step of 60s at open circuit potential. A relative standard deviation of 3.2% was for five determination of 4.0 × 10 -5 mol L-1 Cr (VI). The method was successful applied to determination of Cr(VI) in wastewater samples from a leather dyeing industry. copyright The Electrochemical Society.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A type of ZrO(2)center dot nH(2)O Was synthesized and its Cr(VI) removal potential was investigated in this study. The kinetic study, adsorption isotherm, pH effect, thermodynamic study and desorption were examined in batch experiments. The kinetic process was described by a pseudo-second-order rate model very well. The Cr(VI) adsorption tended to increase with a decrease of pH. The adsorption data fitted well to the Langmuir model. The adsorption capacity increased from 61 to 66 mg g(-1) when the temperature was increased from 298 to 338 K. The positive values of both Delta H degrees and Delta S degrees suggest an endothermic reaction and increase in randomness at the solid-liquid interface during the adsorption. Delta G degrees values obtained were negative indicating a spontaneous adsorption process. The effective desorption of Cr(VI) on ZrO(2)center dot nH(2)O could be achieved using distilled water at pH 12. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A presente tese teve por base a identificação e resolução de um problema existente no tratamento de efluentes provenientes dos processos de tratamento de superfícies por galvanoplastia, na OGMA – Indústria Aeronáutica de Portugal S.A.. Observou-se a ocorrência, esporádica, de crómio hexavalente, (Cr (VI)), em valor superior ao valor limite de emissão (VLE). Os resultados foram monitorizados e os dados recolhidos no decorrer da actividade de tratamento de efluentes, durante o período de, aproximadamente, 5 anos (2006 a 2011). A recolha de resultados decorreu no âmbito da actividade profissional da mestranda, que, para além da responsabilidade técnica dos processos de galvanoplastia na empresa, é também responsável pelo suporte técnico ao processo de tratamento de efluentes resultantes da actividade de tratamento de superficies por processos de galvanoplastia. A empresa OGMA – Indústria Aeronáutica de Portugal S.A., é uma empresa de actividade aeronáutica dedicada à Fabricação e Manutenção de aeronaves, nomeadamente a prestação de serviços de Manutenção, Revisão e Modernização de, Aeronaves, Motores e Componentes, bem como Fabricação e Montagem de Aeroestruturas. Integrada na OGMA, S.A. encontra-se a área de tratamentos electroquímicos, onde são realizados processos de tratamento de materiais metálicos por electrodeposição, deposição química e conversão química. Desta actividade resulta uma quantidade considerável de efluentes líquidos que necessitam de tratamento adequado previamente à sua descarga em cursos de água. Devido ao tipo de contaminantes que estes efluentes possuem, o tratamento dos mesmos é realizado em várias etapas, passando pela oxidação de cianetos, a redução de cromatos e a neutralização. Posteriormente segue-se uma sedimentação e a remoção de lamas. De modo a garantir um controlo dos parâmetros de descarga dos efluentes tratados, de acordo com a legislação ambiental em vigor, o efluente obtido é analisado periodicamente em laboratório acreditado. Na perspectiva de solucionar o problema em questão, procedeu-se à realização de ensaios experimentais utilizando os efluentes provenientes dos tanques de reacção da redução de cromatos e da oxidação de cianetos da linha com cádmio, com especial incidência na variação dos intervalos de pH recomendados para cada uma das fases do tratamento de efluentes, e observação do comportamento das misturas em termos de presença de Cr (VI), quando sujeitos a variações de pH. Após análise dos dados disponíveis e realização de todos os ensaios, conclui-se que, o processo de oxidação de cianeto da linha com cádmio e o processo de redução de cromatos na mesma linha estão a funcionar adequadamente. Concluiu-se que o reaparecimento de Cr (VI) ocorre devido à existência de hipoclorito de sódio, em excesso, no tanque de oxidação de cianeto que, quando passa para o tanque de neutralização e entra em contacto com o efluente proveniente do tanque de redução de cromatos, oxida parte do crómio trivalente, (Cr (III)), existente, a Cr (VI). Para impedir a ocorrência deste fenómeno separou-se todo o efluente contendo crómio que passou a ser tratado na linha de tratamento de efluentes isenta de cádmio, não entrando assim em contacto com o efluente que contém hipoclorito não reagido, evitando a oxidação do Cr (III) a Cr (VI).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The sample under investigation in this project is an experimental chromium enriched yeast used as a possible additive in animal foodstuff, which was produced by growing yeast in the presence of chromium (III) chloride. Chromium on its own in not biologically active but chromium in the form of chromium enriched yeast is biologically active. The objective of this project was to show the complete absence of chromium(VI) from the sample. A literature survey describing previous work carried out on the speciation of Cr(VI) has been carried out. The principal methods of detection of Cr(VI) used in this project are Polarography, G.F.A.A. Spectroscopy, U.V. Spectroscopy and H.P.L.C. For each of the above methods a calibration curve was obtained and each method was applied to the yeast extract. The H.P.L.C. and U.V. spectroscopic method are specific for Cr(VI) but polarography and G.F.A.A. spectroscopy measure total chromium. Tris-NaOH buffer has been investigated for the extraction of chromium(VT). Problems associated with air oxidation of Cr(III) in alkaline solution have identified and procedures described for the suppression of air oxidation. Procedures are described for the application of the extraction procedure to the yeast extract and for the determination of Cr(VI) in the extract. Procedures are also described for the preconcentration of Cr(VI) on a HPLC column and for the application to the yeast extract. The rate of reduction of Cr(VI) by ascorbic acid is investigated and found to be first order with respect to ascorbic acid concentration. The reduction capacity of the yeast is also investigated and it was found that in acid solution the yeast will reduce Cr(VI) but in neutral or basic solution the reduction capacity is diminished. Conclusions regarding the objectives of the project are drawn and suggestions for further work are given.