889 resultados para breathing pattern
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In most reptiles, the ventilatory response to hypercapnia consists of large increases in tidal volume (V-T), whereas the effects on breathing frequency (f(R)) are more variable. The increased V-T seems to arise from direct inhibition of pulmonary stretch receptors. Most reptiles also exhibit a transitory increase in ventilation upon removal of CO2 and this post-hypercapnic hyperpnea may consist of changes in both V-T and f(R). While it is well established that increased body temperature augments the ventilatory response to hypercapnia, the effects of temperature on the post-hypercapnic hyperpnea is less described. In the present study, we characterise the ventilatory response of the agamid lizard Uromastyx aegyptius to hypercapnia and upon the return to air at 25 and 35 degreesC. At both temperatures, hypercapnia caused large increases in V-T and small reductions in f(R), that were most pronounced at the higher temperature. The post-hypercapnic hyperpnea, which mainly consisted of increased fR, was numerically larger at 35 compared to 25 degreesC. However, when expressed as a proportion of the levels of ventilation reached during steady-state hypercapnia, the post-hypercapnic hyperpnea was largest at 25 degreesC. Some individuals exhibited buccal pumping where each expiratory thoracic breath was followed by numerous small forced inhalations caused by contractions of the buccal cavity. This breathing pattern was most pronounced during severe hypercapnia and particularly evident during the post-hypercapnic hyperpnea. (C) 2002 Published by Elsevier B.V.
Resumo:
Anuran amphibians are known to exhibit an intermittent pattern of pulmonary ventilation and to exhibit an increased ventilatory response to hypoxia and hypercarbia. However, only a few species have been studied to date. The aquatic frog Pipa carvalhoi inhabits lakes, ponds and marshes that are rich in nutrients but low in O-2. There are no studies of the respiratory pattern of this species and its ventilation during hypoxia or hypercarbia. Accordingly, the aim of the present study was to characterize the breathing pattern and the ventilatory response to aquatic and aerial hypoxia and hypercarbia in this species. With this purpose, pulmonary ventilation (V-1) was directly measured by the pneumotachograph method during normocapnic normoxia to determine the basal respiratory pattern and during aerial and aquatic hypercarbia (5% CO2) and hypoxia (5% O-2). Our data demonstrate that P. carvalhoi exhibits a periodic breathing pattern composed of single events (single breaths) of pulmonary ventilation separated by periods of apnea. The animals had an enhanced V-1 during aerial hypoxia, but not during aquatic hypoxia. This increase was strictly the result of an increase in the breathing frequency. A pronounced increase in V-1 was observed if the animals were simultaneously exposed to aerial and aquatic hypercarbia, whereas small or no ventilatory responses were observed during separately administered aerial or aquatic hypercarbia. P. carvalhoi primarily inhabits an aquatic environment. Nevertheless, it does not respond to low O-2 levels in water, although it does so in air. The observed ventilatory responses to hypercarbia may indicate that this species is similar to other anurans in possessing central chemoreceptors. (C) 2012 Elsevier Inc. All rights reserved.
Resumo:
The objective of this cross-sectional, descriptive study was to identify the activities of the Nursing Intervention Classification considered as priorities for an Ineffective Breathing Pattern and not performed for elderly inpatients of a teaching hospital in the state of Goias. The study participants were 43 nursing professionals, and data collection was performed in the period spanning October to December 2008, after receiving approval from the Ethics Committee. It was observed that among the 67 activities considered to be priorities for the referred diagnosis, only seven were performed by all of the participants; the other activities, with a varied frequency, were not performed, with the main reason cited being that a professional from a different area completed the activity. It is understood that the fact that the nursing staff does not perform these activities can cause lack of complete coverage in nursing care; therefore there is a need for a legal apparatus to describe the activities that comprise professional practice exclusive to nursing personnel and those activities that have an interdisciplinary nature.
Resumo:
BACKGROUND: Morphological changes in preterm infants with bronchopulmonary dysplasia (BPD) have functional consequences on lung volume, ventilation inhomogeneity and respiratory mechanics. Although some studies have shown lower lung volumes and increased ventilation inhomogeneity in BPD infants, conflicting results exist possibly due to differences in sedation and measurement techniques. METHODOLOGY/PRINCIPAL FINDINGS: We studied 127 infants with BPD, 58 preterm infants without BPD and 239 healthy term-born infants, at a matched post-conceptional age of 44 weeks during quiet natural sleep according to ATS/ERS standards. Lung function parameters measured were functional residual capacity (FRC) and ventilation inhomogeneity by multiple breath washout as well as tidal breathing parameters. Preterm infants with BPD had only marginally lower FRC (21.4 mL/kg) than preterm infants without BPD (23.4 mL/kg) and term-born infants (22.6 mL/kg), though there was no trend with disease severity. They also showed higher respiratory rates and lower ratios of time to peak expiratory flow and expiratory time (t(PTEF)/t(E)) than healthy preterm and term controls. These changes were related to disease severity. No differences were found for ventilation inhomogeneity. CONCLUSIONS: Our results suggest that preterm infants with BPD have a high capacity to maintain functional lung volume during natural sleep. The alterations in breathing pattern with disease severity may reflect presence of adaptive mechanisms to cope with the disease process.
Resumo:
Despite recent advances, the mechanisms of neurorespiratory control in amphibians are far from understood. One of the brainstem structures believed to play a key role in the ventilatory control of anuran amphibians is the nucleus isthmi (NI). This nucleus is a mesencephalic structure located between the roof of the midbrain and the cerebellum, which differentiates during metamorphosis; the period when pulmonary ventilation develops in bullfrogs. It has been recently suggested that the NI acts to inhibit hypoxic and hypercarbic drives in breathing by restricting increases in tidal volume. This data is similar to the influence of two pontine structures of mammals, the locus coeruleus and the nucleus raphe magnus. The putative mediators for this response are glutamate and nitric oxide. Microinjection of kynurenic acid (an ionotropic receptor antagonist of excitatory amino acids) and L-NAME (a non-selective NO synthase inhibitor) elicited increases in the ventilatory response to hypoxia and hypercarbia. This article reviews the available data on the role of the NI in the control of ventilation in amphibians. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Purpose: The purpose of this study was to evaluate mouth-breathing and nasal-breathing children prior to surgical intervention and 28 months postoperatively, comparing the occlusal features obtained pre- and postoperatively through orthodontic study costs. Methods: The mouth-breathing (MB) group consists of 33 MB children who underwent surgery and presented a nasal-breathing (NB) pattern after surgery The control group comprised 22 NB children. The orthodontic examinations were accomplished prior to surgery (77) and an average of 28 months postoperatively (T2). Results: At T1, the MB and NB children presented no statistically significant difference in any analyzed occlusal features and measurements. At T2, the MB presented larger overjet comparing to NB children (P<.05). MB and NB groups presented statistically similar results (P>.05) concerning intercanine and intermolor distances, second primary molar terminal plane and canine relationship, overbite, crossbite, and open bite. From T1 to T2, the MB and NB groups showed a statistically significant difference in the molar terminal plane. Conclusion: Neither the breathing pattern nor the surgery had any effect on occlusal features in 3- to 6-year-olds. (Pediatr Dent 2012;34:10842) Received May 14, 2010 vertical bar Last Revision April 11, 2010 vertical bar Accepted April 12, 2010
Resumo:
OBJETIVOS: Avaliar os efeitos da utilização do biofeedback respiratório (BR) associado ao padrão quiet breathing sobre a perimetria torácica, função pulmonar, força dos músculos respiratórios e os seguintes hábitos de respiradores bucais funcionais (RBF): vigília de boca aberta, boca aberta durante o sono, baba no travesseiro, despertar difícil, ronco e sono inquieto. MÉTODOS: Foram avaliadas 20 crianças RBF, as quais foram submetidas a 15 sessões de BR por meio do biofeedback pletsmovent (MICROHARD® V1.0), o qual proporciona o biofeedback dos movimentos tóraco-abdominais. Perimetria torácica, espirometria e medidas das pressões respiratórias máximas estáticas foram realizadas antes e após a terapia. Questões respondidas pelos responsáveis foram utilizadas para avaliar os hábitos dos RBF. Os dados foram analisados por meio de teste t de Student para dados pareados e testes não paramétricos. RESULTADOS: O uso do BR associado ao padrão quiet breathing não produziu alterações significativas na perimetria torácica e nos valores de volume expiratório forçado no primeiro segundo (VEF1), capacidade vital forçada (CVF), pico de fluxo expiratório (PFE), índice de Tiffeneau (IT) e na pressão expiratória máxima (PEmáx). Entretanto, a pressão inspiratória máxima (PImáx) apresentou diferença estatisticamente significativa (-53,6 ± 2,9 cmH2O vs. -65,0 ± 6,0 cmH2O; p< 0,05) e ocorreram mudanças significativas nos hábitos avaliados. CONCLUSÃO: Os resultados permitem concluir que o BR associado ao padrão quiet breathing melhora a força da musculatura inspiratória e hábitos em RBF, podendo ser, portanto, utilizado como uma das formas de terapia nesses indivíduos.
Resumo:
The primary role of the respiratory system is to ensure adequate tissue oxygenation, eliminate carbon dioxide and help to regulate acid-base status. To maintain this homeostasis, amphibians possess an array of receptors located at peripheral and central chemoreceptive sites that sense respiration-related variables in both internal and external environments. As in mammals, input from these receptors is integrated at central rhythmogenic and pattern-forming elements in the medulla in a manner that meets the demands determined by the environment within the constraints of the behavior and breathing pattern of the animal. Also as in mammals, while outputs from areas in the midbrain may modulate respiration directly, they do not play a significant role in the production of the normal respiratory rhythm. However, despite these similarities, the breathing patterns of the two classes are different: mammals maintain homeostasis of arterial blood gases through rhythmic and continuous breathing, whereas amphibians display an intermittent pattern of aerial respiration. While the latter is also often rhythmic, it allows a degree of fluctuation in key respiratory variables that has led some to suggest that control is not as tight in these animals. In this review we will focus specifically on recent advances in studies of the control of ventilation in anuran amphibians. This is the group of amphibians that has attracted the most recent attention from respiratory physiologists. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Purpose: The purpose of this study was to evaluate mouth-breathing and nasal-breathing children prior to surgical intervention and 28 months postoperatively, comparing the occlusal features obtained pre- and postoperatively through orthodontic study costs. Methods: The mouth-breathing (MB) group consists of 33 MB children who underwent surgery and presented a nasal-breathing (NB) pattern after surgery The control group comprised 22 NB children. The orthodontic examinations were accomplished prior to surgery (77) and an average of 28 months postoperatively (T2). Results: At T1, the MB and NB children presented no statistically significant difference in any analyzed occlusal features and measurements. At T2, the MB presented larger overjet comparing to NB children (P<.05). MB and NB groups presented statistically similar results (P>.05) concerning intercanine and intermolor distances, second primary molar terminal plane and canine relationship, overbite, crossbite, and open bite. From T1 to T2, the MB and NB groups showed a statistically significant difference in the molar terminal plane. Conclusion: Neither the breathing pattern nor the surgery had any effect on occlusal features in 3- to 6-year-olds. (Pediatr Dent 2012;34:10842) Received May 14, 2010 vertical bar Last Revision April 11, 2010 vertical bar Accepted April 12, 2010
Resumo:
INTRODUCTION Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. METHODS Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. RESULTS We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. CONCLUSION FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements.
Resumo:
Research background For almost 80 years the Chuck Taylor (or Chuck T's) All Star basketball shoe has been an iconic item of fashion apparel. The Chuck T's were first designed in 1921 by Converse, an American shoe company and over the decades they became a popular item not purely for sports and athletic purposes but rather evolved into the shoe of choice for many subcultural groups as a fashion item. In some circles the Chuck Taylor is still seen as the "coolest" sneaker of all time - one which will never go out of fashion regardless of changing trends. With over 600 millions pairs sold all over the world since its release, the Converse shoe is representative of not only a fashion culture - but also of a consumption culture - that evolved as the driving force behind the massive growth of the Western economic system during the 20th Century. Artisan Gallery (Brisbane), in conjunction with the exhibition Reboot: Function, Fashion and the Sneaker, a history of the sneaker, selected 20 designers to customise and re-design the classic Converse Chuck Taylor All Stars shoe and in doing so highlighted the diversity of forms possible for creative outcomes. As Artisan Gallery Curator Kirsten Fitzpatrick states “We were expecting people to draw and paint on them. Instead, we had shoes... mounted as trophies.." referring to the presentation of "Converse Consumption". The exhibition ran from 21 June – 16 August 2012: Research question The Chuck T’s is one of many overwhelmingly commercially successful designs of the last century. Nowadays we are faced with the significant problems of overconsumption and the stress this causes on the natural ecosystem; and on people as a result. As an active member of the industrial design fraternity – a discipline that sits at the core of this problem - how can I use this opportunity to comment on the significant issue of consumption? An effective way to do this was to associate consumption of goods with consumption of sugar. There are significant similarities between our ceaseless desires to consume products and our fervent need to consume indulgent sweet foods. Artisan Statement Delicious, scrumptious, delectable... your pupils dilate, your blood pressure spikes, your liver goes into overdrive. Immediately, your brain cuts off the adenosine receptors, preventing drowsiness. Your body increases dopamine production, in-turn stimulating the pleasure receptors in your brain. Your body absorbs all the sweetness and turns it into fat – while all the nutrients that you actually require are starting to be destroyed, about to be expelled. And this is only after one bite! After some time though, your body comes crashing back to earth. You become irritable and begin to feel sluggish. Your eyelids seem heavy while your breathing pattern changes. Your body has consumed all the energy and destroyed all available nutrients. You literally begin to shut down. These are the physiological effects of sugar consumption. A perfect analogy for our modern day consumer driven world. Enjoy your dessert! Research contribution “Converse Consumption” contributes to the conversation regarding over-consumption by compelling people to reflect on their consumption behaviour through the reconceptualising of the deconstructed Chuck T’s in an attractive edible form. By doing so the viewer has to deal with the desire to consume the indulgent looking dessert with the contradictory fact that it is comprised of a pair of shoes. The fact that the shoes are Chuck T’s make the effect even more powerful due to their iconic status. These clashing motivations are what make “Converse Consumption” a bizarre yet memorable experience. Significance The exhibition was viewed by an excess of 1000 people and generated exceptional media coverage and public exposure/impact. As Artisan Gallery Curator Kirsten Fitzpatrick states “20 of Brisbane's best designers were given the opportunity to customise their own Converse Sneakers, with The Converse Blank Canvas Project.” And to be selected in this category demonstrates the calibre of importance for design prominence.
Resumo:
Opioids are most commonly used for treatment of severe pain. However, the fear of respiratory depression has restricted the use of opioids. Depending on the monitoring system used, different modes of opioid respiratory effects have been noted in previous studies. All opioids also cause alterations in hemodynamics at least to some extent. The main goal of this series of investigations was to elucidate the native ventilatory and hemodynamic effects of different opioids. Studies I-IV each involved 8 healthy male volunteers. Study V involved 13 patients with lower or upper extremity traumas. The opioids studied were morphine, oxycodone, pethidine, fentanyl, alfentanil, tramadol and ketamine. The respiratory parameters used in this study were breathing pattern measured with respiratory inductive plethysmography, gas exchange measured with indirect calorimetry, blood gas analysis and pulse oximetry. Hemodynamics was measured with arterial blood pressure, heart rate and oxygen consumption. Plasma catecholamine and histamine concentrations were also determined. All opioids studied caused an alteration in respiratory function. Respiratory rate, alveolar ventilation and minute ventilation decreased, while tidal volume increased in most situations. Breathing pattern was also significantly affected after opioid administration. The respiratory depression caused by oxycodone was deeper than the one caused by same dose of morphine. An equianalgesic dose of tramadol caused markedly smaller respiratory depression compared to pethidine. The potency ratio for respiratory depression of fentanyl and alfentanil is similar to analgesic potency ratio studied elsewhere. Racemic ketamine attenuated the respiratory depression caused by fentanyl, if measured with minute ventilation. However, this effect was counteracted by increased oxygen consumption. Supplemental oxygen did not offer any benefits, nor did it cause any atelectasis when given to opioid treated trauma patients. Morphine caused a transient hemodynamic stimulation, which was accompanied by an increase in oxygen consumption. Oxycodone, alfentanil, fentanyl, tramadol and pethidine infusions had minimal effects on hemodynamics. Plasma catecholamine concentrations were increased after high dose opioid administration. Plasma histamine concentrations were not elevated after morphine nor oxycodone administration. Respiratory depression is a side effect noted with all opioids. The profile of this phenomenon is quite similar with different opioid-receptor agonists. The hemodynamic effects of opioids may vary depending on the opioid used, morphine causing a slight hemodynamic stimulation. However, all opioids studied could be considered hemodynamically stable.
Resumo:
In this paper, the design and development of a novel low-cost, non-invasive type sensor suitable for human breath sensing is reported. It can be used to detect respiratory disorders like bronchial asthma by analyzing the recorded breathing pattern. Though there are devices like spirometer to diagnose asthma, they are very inconvenient for patient's use because patients are made to exhale air through mouth forcefully. Presently developed sensor will overcome this limitation and is helpful in the diagnosis of respiratory related abnormalities. Polyvinylidene fluoride (PVDF) film in cantilever configuration is used as a sensing element to form the breath sensor. Two identical sensors are mounted on a spectacle frame, such that the tidal flow of inhaled and exhale air will impinge on sensor, for sensing the breathing patterns. These patterns are recorded, filtered, analyzed and displayed using CRO. Further the sensor is calibrated using a U-tube water manometer. The added advantage of piezoelectric type sensing element is that it is self powered without the need of any external power source.
Resumo:
Rattlesnakes use their facial pit organs to sense external thermal fluctuations. A temperature decrease in the heat-sensing membrane of the pit organ has the potential to enhance heat flux between their endothermic prey and the thermal sensors, affect the optimal functioning of thermal sensors in the pit membrane and reduce the formation of thermal ‘‘afterimages’’, improving thermal detection. We examined the potential for respiratory cooling to improve strike behaviour, capture, and consumption of endothermic prey in the South American rattlesnake, as behavioural indicators of thermal detection. Snakes with a higher degree of rostral cooling were more accurate during the strike, attacking warmer regions of their prey, and relocated and consumed their prey faster. These findings reveal that by cooling their pit organs, rattlesnakes increase their ability to detect endothermic prey; disabling the pit organs caused these differences to disappear. Rattlesnakes also modify the degree of rostral cooling by altering their breathing pattern in response to biologically relevant stimuli, such as a mouse odour. Our findings reveal that low humidity increases their ability to detect endothermic prey, suggesting that habitat and ambush sites election in the wild may be influenced by external humidity levels as well as temperature.