988 resultados para boost zcs-fm


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new single-phase interleaved high power factor boost pre-regulator operating in critical conduction mode, where the switches and boost diode performing zero-current commutations during its turn-off, eliminating the disadvantages related to the reverse recovery losses and electromagnetic interference problems of the boost diode, when operating in the continuous conduction mode. The interleaving technique is applied in the power cell, providing a significant input current ripple reduction in comparison to discontinuous mode of operation, due to its input current continuous conduction operation. This paper presents a complete modeling for the converter operating in critical conduction mode, resulting in an improved design procedure for interleaved techniques with high input power factor, a complete design procedure, and main simulation results from a design example with two interleaved cells rated at 1kW, 400V output voltage and 220V rms input voltage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a 2kW single-phase high power factor boost rectifier with four cells in interleave connection, operating in critical conduction mode, and employing a soft-switching technique, controlled by Field Programmable Gate Array (FPGA). The soft-switching technique Is based on zero-current-switching (ZCS) cells, providing ZC (zero-current) turn-on and ZCZV (zero-current-zero-voltage) turn-off for the active switches, and ZV (zero-voltage) turn-on and ZC (zero-current) turn-off for the boost diodes. The disadvantages related 'to reverse recovery effects of boost diodes operated in continuous conduction mode (additional losses, and electromagnetic interference (EMI) problems) are minimized, due to the operation in critical conduction mode. In addition, due to the Interleaving technique, the rectifer's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) In the input current, in compliance with the TEC61000-3-2 standards. The digital controller has been developed using a hardware description language (VHDL) and implemented using a XC2S200E-SpartanII-E/Xilinx FPGA device, performing a true critical conduction operation mode for four interleaved cells, and a closed-loop to provide the output voltage regulation, like as a pre-regulator rectifier. Experimental results are presented for a 2kW implemented prototype with four interleaved cells, 400V nominal output voltage and 220V(rms) nominal input voltage, in order to verify the feasibility and performance of the proposed digital control through the use of a FPGA device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a new pre-regulator boost operating in the boundary area between the continuous and discontinuous conduction modes of the boost inductor current, where the switches and boost diode performing zero-current commutations during its turn-off, eliminating the disadvantages related to the reverse recovery losses and electromagnetic interference problems of the boost diode when operating in the continuous conduction mode. Additionally, the interleaving technique is applied in the power cell, providing a significant input current ripple reduction. It should be noticed that the main objective of this paper is to present a complete modeling for the converter operating in the critical conduction mode, allowing an improved design procedure for interleaved techniques with high input power factor, a complete dynamic analysis of the structure, and the possibility of implementing digital control techniques in closed loop.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a novel single-phase high-power-factor (HPF) pulsewidth-modulated (PWM) boost rectifier featuring soft commutation of the active switches at zero current (ZC), It incorporates the most desirable properties of conventional PWM and soft-switching resonant techniques.The input current shaping is achieved with average current mode control and continuous inductor current mode.This new PWM converter provides ZC turn on and turn off of the active switches, and it is suitable for high-power applications employing insulated gate bipolar transistors (IGBT's),The principle of operation, the theoretical analysis, a design example, and experimental results from a laboratory prototype rated at 1600 W with 400-Vdc output voltage are presented. The measured efficiency and the power factor were 96.2% and 0.99%, respectively, with an input current total harmonic distortion (THD) equal to 3.94%, for an input voltage with THD equal to 3.8%, at rated load.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a multi-cell single-phase high power factor boost rectifier in interleave connection, operating in critical conduction mode, employing a soft-switching technique, and controlled by Field Programmable Gate Array (FPGA). The soft-switching technique is based on zero-current-switching (ZCS) cells, providing ZC (zero-current) turn-on and ZCZV (zero-current-zero-voltage) turn-off for the active switches, and ZV (zero-vohage) turn-on and ZC (zero-current) turn-off for the boost diodes. The disadvantages related to reverse recovery effects of boost diodes operated in continuous conduction mode (additional losses, and electromagnetic interference (EMI) problems) are minimized, due to the operation in critical conduction mode. In addition, due to the interleaving technique, the rectifier's features include the reduction in the input current ripple, the reduction in the output voltage ripple, the use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller has been developed using a hardware description language (VHDL) and implemented using a XC2S200E-SpartanII-E/Xilinx FPGA device, performing a true critical conduction operation mode for all interleaved cells, and a closed-loop to provide the output voltage regulation, like as a preregulator rectifier. Experimental results are presented for a implemented prototype with two and with four interleaved cells, 400V nominal output voltage and 220V(rms) nominal input voltage, in order to verify the feasibility and performance of the proposed digital control through the use of a FPGA device.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a novel single-phase high power factor PWM boost rectifier, featuring soft commutation of the active switches at zero-current (ZCS). It incorporates the most desirable properties of the conventional PWM and the soft-switching resonant techniques. The input current shaping is achieved with average current mode control, and continuous inductor current mode. This new PWM converter provides ZCS turn-on and turn-off of the active switches, and it is suitable for high power applications employing IGBTs. Principle of operation, theoretical analysis, a design example, and experimental results from a laboratory prototype rated at 1600 W with 400 Vdc output voltage are presented. The measured efficiency and power factor were 96.2% and 0.99 respectively, with an input current THD equal to 3.94%, for an input voltage THD equal to 3.8%, at rated load.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new family of direct current (DC) to DC converters based on a zero current switching pulse width modulated (ZCS-PWM) soft commutation cell is presented. This ZCS-PWM cell is consists of two transistors, two diodes, two inductors and one capacitor; and provides zero voltage turn-on to the diodes, a zero-current turn-on and a zero-current zero-voltage turn-off to the transistors. In addition, a new commutation cell in a new ZCS-PWM boost rectifier is developed, obtaining a structure with power factor near the unity, high efficiency at wide load range and low total harmonic distortion in the input current.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A Summary of different topological arrangements concerning a ZCS-PWM cell is presented, based on the analysis of its application in boost rectifying preregulators, controlled by the technique of instantaneous average values of input current, with the purpose of obtaining high-input-power-factor rectifier and high efficiency in single-phase applications in telecommunication systems. The main characteristics of each switching cell are described, providing conditions to establish a qualitative comparison among the structures. In addition, experimental results are presented for a prototype of the latest version of the ZCS-PWM boost rectifier, implemented for processing normal values of 1200 W output power and 400 V output average voltage, at 220 V Input RMS voltage and 50 kHz switching frequency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper introduces novel zero-current-switching (ZCS) pulsewidth-modulated (PWM) preregulators based on a new soft-commutation cell, suitable for insulated gate bipolar transistor applications. The active switches in these proposed rectifiers turn on in zero current and turn off in zero current-zero voltage. In addition, the diodes turn on in zero voltage and their reverse-recovery effects over the active switches are negligible. Moreover, based on the proposed cell, an entire family of de-to-de ZCS-PWM converters can be generated, providing conditions to obtain naturally isolated converters, for example, derived buck-boost, Sepic. and Zeta converters. The novel ac-to-dc ZCS-PWM boost and Zeta preregulators are presented in order to verify the operation of this soft-commutation cell, In order to minimize the harmonic contents of the input current, increasing the ac power factor, the average-current-mode control is used, obtaining preregulators with ac power factor near unity and high efficiency at wide load range. The principle of operation, theoretical analysis, design example, and experimental results from test units for the novel preregulators are presented. The new boost preregulator was designed to nominal values of 1.6 kW output power, 220 V(rms) input voltage, 400 V(dc) output voltage, and operating at 20 kHz. The measured efficiency and power factor of the new ZCS-PWM boost preregulator were 96.7% and 0,99, respectively, with an input current total harmonic distortion (THD) equal to 3.42% for an input voltage with THD equal to 1.61%, at rated load, the new ZCS-PWM Zeta preregulator was designed to voltage step-down operation, and the experimental results were obtained from a laboratory prototype rated at 500 W, 220 V(rm), input voltage, 110 V(dc) output voltage, and operating at 50 kHz. The measured efficiency of the new ZCS-PWM Zeta preregulator is approximately 96.9% and the input power factor is 0.98, with an input current THD equal to 19.07% while the input voltage THD is equal to 1.96%, at rated load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: To evaluate biochemical control and treatment related toxicity of patients with localized adenocarcinoma of the prostate treated with high dose-rate brachytherapy (HDRB) combined with conventional 2D or 3D-conformal external beam irradiation (EBI). Material and methods: Four-hundred and three patients treated between December 2000 and March 2004. HDRB was delivered with three fractions of 5.5-7 Gy with a single implant, followed by 45 Gy delivered with 2D or 3D conformal EBI. Results: The median follow-up was 48.4 months. Biochemical failure (BF) occurred in 9.6% according to both ASTRO and Phoenix consensus criteria. Mean time to relapse was 13 and 26 months, respectively. The 5-year BF free survival using the ASTRO criteria was 94.3%, 86.9% and 86.6% for the low, intermediate and high risk groups, respectively; using Phoenix criteria, 92.4%, 88.0% and 85.3%, respectively. The only predictive factor of BF in the multivariate analysis by both ASTRO and Phoenix criteria was the presence of prostate nodules detected by digital palpation, and patients younger than 60 years presented a higher chance of failure using Phoenix criteria only. Conclusions: Treatment scheme is feasible and safe with good efficacy. (C) 2011 Elsevier Ireland Ltd All rights reserved. Radiotherapy and Oncology 98 (2011) 169-174

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O crescente aumento da consciencialização da importância da fase de operação e manutenção, bem como a amplificação que a metodologia Building Information Modelling (BIM) tem obtido nos últimos anos, sugere uma necessidade de alterar a atual abordagem da gestão das instalações de forma a dotá-la das mais recentes inovações tecnológicas como seja a utilização do BIM. Os Building Information Models apresentam as características ideais para a integração da gestão das instalações, não só pela visualização do edifício, mas sobretudo pela potencialidade que a base de dados oferece, com informação referente a cada um dos componentes presentes e suas relações. O âmbito deste trabalho envolve assim a integração da gestão das instalações com o modelo BIM criado, representativo do edifício em estudo. Este trabalho começa com as definições do âmbito e dos objetivos que são propostos no Capítulo 1. No Capítulo 2, é elaborada uma pesquisa sobre o estado da arte atual de cada uma das metodologias BIM e FM, de forma a tomar conhecimento dos seus conceitos principais. Foi feito também um levantamento no campo do BIM-FM de forma a apurar as atuais soluções tecnológicas existentes, a forma como é feita a sua troca de informação e também alguns casos em que esta metodologia foi aplicada. Com base na informação recolhida sobre as metodologias e também nos casos práticos estudados, é realizado no Capítulo 3, capítulo central deste trabalho, a aplicação prática. A realização desta aplicação é dividida por 3 fases principais. Numa primeira fase é especificada e recolhida a informação necessária de ser obtida para a realização do modelo e a posterior aplicação do FM. A escolha da informação a recolher é feita ponderando todos os fatores existentes, mas de forma a cumprir os requisitos pedidos. Numa segunda fase, assente na compilação de informação recolhida anteriormente, realiza-se o modelo do edifício. A modelação, de forma a seguir o método de trabalho BIM é realizada por especialidades, sendo numa primeira fase realizada a especialidade de arquitetura e posteriormente, utilizando esse modelo como base, é feita a modelação das especialidades de águas, águas residuais, AVAC e eletricidade. Esta escolha foi também estimulada pela organização do software utilizado para a modelação, por módulos. Na última fase da aplicação do caso prático a informação inserida na fase de modelação do edifício é exportada para o software de FM, neste caso em específico, o IBM Maximo. Para a exportação destes dados foi utilizado o formato Construction Operations Building Information Exchange (COBie), de forma a garantir a integridade e conformidade da informação transferida. No Capítulo 4 deste trabalho são abordadas as especificidades relativas à informação existente, à modelação e à troca de dados entre o software de modelação e o software utilizado na gestão do edifício. São também sugeridos alguns temas para futuros desenvolvimentos com o intuito de ampliação dos campos de FM com o uso do modelo. O BIM-FM é um tema emergente na atualidade do BIM, sendo a sua utilização encarada como uma mais-valia ao processo BIM. A compilação da informação durante a fase de projeto e execução, aliada à existência do modelo torna a implementação do FM com o modelo BIM como uma sequência natural.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is about a PV system connected to the electric grid by power electronic converters, using classical PI controller. The modelling for the converters emulates the association of a DC-DC boost with a two-level power inverter (TwLI) or three-level power inverter (ThLI) in order to follow the performance of a testing experimental system. Pulse width modulation (PWMo) by sliding mode control (SMCo) associated with space vector modulation (SVMo) is applied to the boost and the inverter. The PV system is described by the five parameters equivalent circuit. Parameter identification and simulation studies are performed for comparison with the testing experimental system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is about a PV system linked to the electric grid through power converters under cloud scope. The PV system is modeled by the five parameters equivalent circuit and a MPPT procedure is integrated into the modeling. The modeling for the converters models the association of a DC-DC boost with a three-level inverter. PI controllers are used with PWM by sliding mode control associated with space vector modulation controlling the booster and the inverter. A case study addresses a simulation to assess the performance of a PV system linked to the electric grid. Conclusions regarding the integration of the PV system into the electric grid are presented. © IFIP International Federation for Information Processing 2015.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Management from the NOVA – School of Business and Economics