Modeling of pre-regulator boost ZCS interleaved operating in critical conduction mode and with high power factor


Autoria(s): Canesin, Carlos A.; Gonçalves, Flávio A. S.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

27/05/2014

27/05/2014

01/12/2002

Resumo

This paper presents a new pre-regulator boost operating in the boundary area between the continuous and discontinuous conduction modes of the boost inductor current, where the switches and boost diode performing zero-current commutations during its turn-off, eliminating the disadvantages related to the reverse recovery losses and electromagnetic interference problems of the boost diode when operating in the continuous conduction mode. Additionally, the interleaving technique is applied in the power cell, providing a significant input current ripple reduction. It should be noticed that the main objective of this paper is to present a complete modeling for the converter operating in the critical conduction mode, allowing an improved design procedure for interleaved techniques with high input power factor, a complete dynamic analysis of the structure, and the possibility of implementing digital control techniques in closed loop.

Formato

305-310

Identificador

http://dx.doi.org/10.1109/IECON.2002.1187526

IECON Proceedings (Industrial Electronics Conference), v. 1, p. 305-310.

1553-572X

http://hdl.handle.net/11449/67054

10.1109/IECON.2002.1187526

WOS:000181518100055

2-s2.0-0036954757

Idioma(s)

eng

Relação

IECON Proceedings (Industrial Electronics Conference)

Direitos

closedAccess

Palavras-Chave #Critical conduction mode #High power factor #Pre-regulator boost zero current switching #Zero-current commutation #Closed loop control systems #Computer simulation #Digital control systems #Diodes #Electric batteries #Electric commutation #Electric losses #Electric power factor #Switching networks #Electric inductors
Tipo

info:eu-repo/semantics/conferencePaper