900 resultados para blood pressure measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM To investigate the number of hypertensive patients, the optometrist is able to identify by routinely taking blood pressure (BP) measurements for patients in "at -risk" groups, and to sample patients' opinions regarding in -office BP measurement. Many of the optometrists in Saudi Arabia practice in optical stores. These stores are wide spread, easily accessible and seldom need appointments. The expanding role of the optometrist as a primary health care provider (PHCP) and the increasing global prevalence of hypertension, highlight the need for an integrated approach towards detecting and monitoring hypertension. METHODS Automated BP measurements were made twice (during the same session) at five selected optometry practices using a validated BP monitor (Omron M6) to assess the number of patients with high BP (HBP) - in at -risk groups -visiting the eye clinic routinely. Prior to data collection, practitioners underwent a two-day training workshop by a cardiologist on hypertension and how to obtain accurate BP readings. A protocol for BP measurement was distributed and retained in all participating clinics. The general attitude towards cardiovascular health of 480 patients aged 37.2 (依12.4)y and their opinion towards in-office BP measurement was assessed using a self -administered questionnaire. RESULTS A response rate of 83.6% was obtained for the survey. Ninety -three of the 443 patients (21.0% ) tested for BP in this study had HBP. Of these, (62 subjects) 67.7% were unaware of their HBP status. Thirty of the 105 subjects (28.6%) who had previously been diagnosed with HBP, still had HBP at the time of this study, and only 22 (73.3%) of these patients were on medication. Also, only 25% of the diagnosed hypertensive patients owned a BP monitor. CONCLUSION Taking BP measurements in optometry practices, we were able to identify one previously undiagnosed patient with HBP for every 8 adults tested. We also identified 30 of 105 previously diagnosed patients whose BP was poorly controlled, twenty-two of whom were on medication. The patients who participated in this study were positively disposed toward the routine measurement of BP by optometrists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The traditional basis for assessing the effect of antihypertensive therapy is the blood pressure reading taken by a physician. However, several recent trials have been designed to evaluate the blood pressure lowering effect of various therapeutic agents during the patients' normal daytime activities, using a portable, semi-automatic blood pressure recorder. The results have shown that in a given patient, blood pressure measured at the physician's office often differs greatly from that prevailing during the rest of the day. This is true both in treated and untreated hypertensive patients. The difference between office and ambulatory recorded pressures cannot be predicted from blood pressure levels measured by the physician. Therefore, a prospective study was carried out in patients with diastolic blood pressures that were uncontrolled at the physician's office despite antihypertensive therapy. The purpose was to evaluate the response of recorded ambulatory blood pressure to treatment adjustments aimed at reducing office blood pressure below a pre-set target level. Only patients with high ambulatory blood pressures at the outset appeared to benefit from further changes in therapy. Thus, ambulatory blood pressure monitoring can be used to identify those patients who remain hypertensive only when facing the physician, despite antihypertensive therapy. Ambulatory monitoring could thus help to evaluate the efficacy of antihypertensive therapy and allow individual treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study analyzed the accuracy/agreement of the Omron MX3 monitor on 165 adolescents. Blood pressure was measured by the automatic monitor connected in Y with the mercury column (three consecutive and simultaneous measures). The independent measures were analyzed, and the mean differences between systolic and diastolic measures for both methods were calculated and compared with British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) criteria. The automatic monitor received the highest degree of BHS recommendations for systolic and diastolic blood pressures according to the BHS. The median (25th and 75th) difference between the observer and the monitor measurements was -2 (-6 and 1) mmHg for systolic and 0 (-3 and1) mmHg for diastolic pressures. The monitor also satisfies the AAMI standard for the studied population. In conclusion, the Omron MX3 Plus monitor can be considered reliable and valid for clinical practice and is in accordance with BHS and AAMI criteria.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To evaluate high-definition and conventional oscillometry in comparison with direct blood pressure measurements in anaesthetised dogs. METHODS: Eight simultaneous readings for systolic, diastolic and mean pressure were obtained directly and with each of two devices in nine anaesthetised dogs. Measurement procedure and validation were based on the 2007 ACVIM guidelines. RESULTS: Sixty-three simultaneous readings were evaluated for each device and direct measurements. The mean differences (bias) to direct values were within 10 mmHg for both devices although bias for systolic and diastolic blood pressures was higher for Memodiagnostic. The standard deviations of differences (precision) were within 15 mmHg for Dinamap but exceeded for Memodiagnostic. Correlation coefficients were higher for Dinamap than Memodiagnostic but both failed to reach a correlation of 0.9. Over 50% of values lay within 10 mmHg of direct measures for both devices, but this percentage was greater for Dinamap than Memodiagnostic. Over 80% of values lay within 20 mmHg of direct measures for Dinamap but not for Memodiagnostic. CLINICAL SIGNIFICANCE: Both devices failed to meet ACVIM guideline validation. However, Dinamap only failed with regards to correlation. Memodiagnostic failed on several requirements, and based on poor correlation, accuracy and precision, this device cannot be currently recommended for dogs under anaesthesia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the agreement of blood pressure measurements and hypertension scores obtained by use of 3 indirect arterial blood pressure measurement devices in hospitalized dogs. Design-Diagnostic test evaluation. ANIMALS: 29 client-owned dogs. PROCEDURES: 5 to 7 consecutive blood pressure readings were obtained from each dog on each of 3 occasions with a Doppler ultrasonic flow detector, a standard oscillometric device (STO), and a high-definition oscillometric device (HDO). RESULTS: When the individual sets of 5 to 7 readings were evaluated, the coefficient of variation for systolic arterial blood pressure (SAP) exceeded 20% for 0% (Doppler), 11 % (STO), and 28% (HDO) of the sets of readings. After readings that exceeded a 20% coefficient of variation were discarded, repeatability was within 25 (Doppler), 37 (STO), and 39 (HDO) mm Hg for SAP. Correlation of mean values among the devices was between 0.47 and 0.63. Compared with Doppler readings, STO underestimated and HDO overestimated SAP. Limits of agreement between mean readings of any 2 devices were wide. With the hypertension scale used to score SAP, the intraclass correlation of scores was 0.48. Linear-weighted inter-rater reliability between scores was 0.40 (Doppler vs STO), 0.38 (Doppler vs HDO), and 0.29 (STO vs HDO). CONCLUSIONS AND CLINICAL RELEVANCE: Results of this study suggested that no meaningful clinical comparison can be made between blood pressure readings obtained from the same dog with different indirect blood pressure measurement devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose - The UK Prospective Diabetic Study has confirmed the importance of blood pressure (BP) as a major risk factor for diabetic retinopathy (DR). We wanted to investigate whether measuring the BP in the diabetic eye clinic could identify new hypertensive patients and monitor control in existing ones. Patients and methods - We compared BP in patients attending the diabetic eye clinic with home blood pressure measurement (HBPM) and ambulatory BP measurement (ABPM). In all, 106 patients attending a diabetic eye clinic were selected at random from clinic attendees. BP measurement (on an Omron 705 CP) was performed in the eye clinic and also compared to HBPM three times per day with an Omron 705 CP machine, and was compared to diabetic clinic measurements. In addition, 11 randomly chosen patients had 24 h ABPM to validate the above techniques. Results - In all, 106 patients (70 male and 36 female) were recruited for the study, of which 71 were known to be hypertensive on antihypertensive medication. Of the total, 75 patients (70.8%) had BP>140/85 in the eye clinic, of which 51 (68%) were known to be hypertensive on treatment and this was confirmed in 46 (90%) on HBPM. A total of, 24 patients (22.6%) were newly diagnosed as hypertensive in the eye clinic, which was confirmed by HBPM in 22 patients (92%). The mean BP of the measurements performed in the eye clinic was significantly higher than that carried out in the diabetic clinic (P<0.01). Tropicamide 1% and phenylephrine 2.5% eye drop instillation had no effect on BP. In 11 randomly chosen patients, 24 h ABPM validated both diabetic eye clinic and home BP measurements. Conclusion - Attendance at the diabetic eye clinic is an important chance to detect both new patients with systemic hypertension and those with inadequate BP control. Ophthalmologists should be encouraged to measure BP in their diabetic patients attending diabetic eye clinics, as it is an important risk factor for DR. On the basis of our findings, good BP control is a goal yet to be achieved in diabetic patients with retinopathy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Glucocorticoid hormones are critical to respond and adapt to stress. Genetic variations in the glucocorticoid receptor (GR) gene alter hypothalamic-pituitary-adrenal (HPA) axis activity and associate with hypertension and susceptibility to metabolic disease. Here we test the hypothesis that reduced GR density alters blood pressure and glucose and lipid homeostasis and limits adaption to obesogenic diet. Heterozygous GR βgeo/+ mice were generated from embryonic stem (ES) cells with a gene trap integration of a β-galactosidase-neomycin phosphotransferase (βgeo) cassette into the GR gene creating a transcriptionally inactive GR fusion protein. Although GRβgeo/+ mice have 50% less functional GR, they have normal lipid and glucose homeostasis due to compensatory HPA axis activation but are hypertensive due to activation of the renin-angiotensin- aldosterone system (RAAS). When challenged with a high-fat diet, weight gain, adiposity, and glucose intolerance were similarly increased in control and GRβgeo/+ mice, suggesting preserved control of intermediary metabolism and energy balance. However, whereas a high-fat diet caused HPA activation and increased blood pressure in control mice, these adaptions were attenuated or abolished in GRβgeo/+ mice. Thus, reduced GR density balanced by HPA activation leaves glucocorticoid functions unaffected but mineralocorticoid functions increased, causing hypertension. Importantly, reduced GR limits HPA and blood pressure adaptions to obesogenic diet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the present study was to evaluate the effects of Lactobacillus helveticus fermented milk (peptide milk) containing the casein-derived tripeptides Isoleucyl-prolyl-proline (Ile-Pro-Pro) and Valyl-prolyl-proline (Val-Pro-Pro) on blood pressure and vascular function in hypertensive subjects. The peptide milk lowered systolic and diastolic blood pressure in long-term use in hypertensive subjects when blood pressure was measured by using 24-hour ambulatory blood pressure measurement (ABPM). The blood pressure lowering effect was seen with the dose of 50 mg of tripeptides, and a tendency for lowering blood pressure was also observed when the dose was 5 mg. No adverse effects compared to the placebo group were reported or detected in laboratory analysis. The effect of the peptide milk on arterial stiffness was shown using two different methods, the ambulatory arterial stiffness index (AASI) and pulse wave analysis (PWA). According to the AASI, arterial stiffness was significantly reduced in the peptide milk group compared to the baseline level, but the difference was not significant compared to the placebo group. PWA showed that the peptide milk reduced arterial stiffness significantly compared to the placebo group. Endothelium-independent relaxation (nitroglycerin) and endothelium-dependent relaxation (salbutamol) did not differ between the groups. The blood pressure lowering mechanisms of the tripeptides and the kinetics of Ile-Pro-Pro were investigated using spontaneously hypertensive rats (SHR) and Sprague-Dawley rats. Previous studies have suggested that the blood pressure lowering effect of the tripeptides Ile-Pro-Pro and Val-Pro-Pro is based on angiotensin-converting enzyme inhibition, but the present findings did not agree with these previous studies. It was shown in SHR that calcium, potassium and magnesium may also have an important role in attenuating the development of hypertension as part of the peptide milk effect. In addition, the present study suggests indirectly that improved endothelial nitric oxide release capacity is not the mechanism by which peptide milk mediates its favourable circulatory effects. The kinetics of Ile-Pro-Pro were studied using adult Sprague-Dawley rats. The results showed that orally administered Ile-Pro-Pro is absorbed at least partly intact from the gastrointestinal tract. Radiolabelled Ile-Pro-Pro was distributed in different tissues and considerable radioactivity levels were found in tissues related to the renin-angiotensin system (RAS), adrenals, aorta and kidneys. Ile-Pro-Pro does not bind to plasma proteins, and therefore it is possible that its blood pressure lowering effect is mediated by free Ile-Pro-Pro. In conclusion, consumption of the peptide milk lowers blood pressure and reduces arterial stiffness in hypertensive subjects. Ile-Pro-Pro can be absorbed partly intact from the gastrointestinal tract and might accumulate in tissues related to the RAS. The precise blood pressure lowering mechanism of peptide milk remains to be studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article outlines the process of taking a manual blood pressure measurement. The author suggests that it is a skill that nursing students should be using in clinical practice rather than relying on automated monitors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hypertension is thought to exist in up to five percent of children. A select number of studies have investigated the role elevated blood pressure plays in pediatric atherosclerotic progression. However these studies contain significant methodological flaws and fail to recognize important confounding factors. Therefore, the influence of elevated blood pressure on arterial health in children remains to be clearly understood. The purpose of this study was to investigate the association between blood pressure (BP) and arterial thickness and stiffuess in children. Common carotid artery (CCA) intima-media thickness (IMT) and distensibility (Dist), as well as systemic pulse wave velocity (PWV) were measured in 21 elevated blood pressure (EBP; BP ~ 95th percentile) and 83 normal blood pressure (NBP; BP < 90th percentile) children 11-14 years of age. Both EBP and NBP groups demonstrated BP within the normal clinical range, but EBP showed significantly elevated BP as compared to the NBP group. Independent t-tests failed to show significant differences between the EBP and NBP groups for CCA IMT (0.43 ± 0.05 mm and 0.42 ± 0.06 mm, respectively) and Dist (0.0058 ± 0.0024 mmHg-1 and 0.0064 ± 0.0019 mmHil respectively). In contrast, a significantly elevated PWV (p

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Microalbuminuria may reflect diffuse endothelial damage. Considering that diabetes and hypertension cause vasculopathy, we investigated associations of albumin-to-creatinine ratio (ACR) with plasma glucose and blood pressure levels in high-risk subjects for metabolic syndrome. Methods: A sample of 519 (246 men) Japanese-Brazilians (aged 60 ± 11 years), who participated in a population-based study, had their ACR determined in a morning urine specimen. Backward models of multiple linear regression were created for each gender including log-transformed values of ACR as dependent variable; an interaction term between diabetes and hypertension was included. Results: Macroalbuminuria was found in 18 subjects. ACR mean values for subjects with normal glucose tolerance, impaired fasting glycemia, impaired glucose tolerance and diabetes were 9.9 ± 6.0, 19.0 ± 35.4, 20.7 ± 35.4, and 33.9 ± 55.0 mg/g, respectively. Diabetic subjects showed higher ACR than the others (p < 0.05). An increase in the proportion of albuminuric subjects was observed as glucose metabolism deteriorated (4.9, 17.0, 23.0 and 36.0%). Stratifying into 4 groups according to postchallenge glycemia (< 7.8 mmol/l, n = 9 1; ≥ 7.8 mmol/l, n = 4 10) and hypertension, hypertensive and glucose-intolerant subgroups showed higher ACR values. ACR was associated with gender, waist circumference, blood pressure, plasma glucose and triglyceride (p < 0.05); albuminuric subjects had significantly higher levels of such variables than the normoalbuminuric ones. In the final models of linear regression, systolic blood pressure and 2-hour glycemia were shown to be independent predictors of ACR for both genders (p < 0.05). In men, also waist was independently associated with ACR. No interaction was detected between diabetes and hypertension. Conclusions: These findings suggest that both glucose intolerance and hypertension could have independent but not synergistic effects on endothelial function - reflected by albumin loss in urine. Such hypothesis needs to be confirmed in prospective studies. © 2004 Dustri-Verlag Dr. K. Feistle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Study design: Association study Objective: To analyze the association between different biological/behavioral risk factors and blood pressure in a sample of type 2 diabetes mellitus patients with poor glycemic control. Methods: A sample of 121 type 2 diabetic patients was selected in the Public Healthcare System in a middle size Brazilian city. Blood pressure was measured using an aneroid device, previously calibrated. Six determinants of blood pressure were taken into count: age, hypoglycemic agents, general obesity, abdominal obesity, eating behaviors and physical activity level. Results: The type 2 diabetic patients presented mean age of 60.1±8.9 years-old and, at least, one risk factor. Eating behaviors (OR adj= 0.31 [0.12-0.75]) and sports practice (OR adj= 0.12 [0.02-0.75]) constituted protective factors associated with lower systolic blood pressure. On the other hand, age was positively associated with high systolic blood pressure (OR adj= 3.81 [1.39-10.38]). Patients with 5-6 risk factors, presented higher values of systolic and (F= 3.857; p= 0.011 [post hoc with p= 0.039]), diastolic blood pressure (F= 4.158; p= 0.008 [post hoc with p= 0.036]) and increased occurrence of hypertension (p= 0.010). Conclusion: Our findings indicate that, behavioral variables were important determinants of blood pressure in type 2 diabetic patients with poor glycemic control and clustering of behavioral and biological risk factors increase the hypertension occurrence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To examine the independent and combined association of physical activity (PA) and sedentary behavior (SB) on both systolic (SBP) and diastolic blood pressure (DBP) in adolescents from two observational studies. Methods: Participants from two cross-sectional studies, one conducted in Europe (n = 3,308; HELENA study) and the other in Brazil (n = 991; BRACAH study), were selected by complex sampling. Systolic and diastolic blood pressure (outcomes), PA and SB, both independently and combined, and potential confounders were analyzed. Associations were examined by multilevel linear regression. Results: Performing the recommended amount of PA (≥60 min/d) attenuated the effect of SB on DBP in BRACAH study girls and in boys from both studies. In contrast, PA did not attenuate the effects of SB on the SBP of girls in the HELENA study. The combination of less than recommended levels of PA with 2-4 h/d of sedentary behavior was found to be associated with increased SBP in boys from both studies. Conclusions: Meeting current PA recommendations could mediate the association between SB and DBP in both sexes. In boys, the joint effect of low levels of PA and excessive sedentary activity increases SBP levels. Longitudinal studies are required to confirm these findings. © 2013 de Moraes et al.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO:Revisar a literatura sobre estudos que estimaram a prevalência de pressão arterial elevada (PAE) ou hipertensão arterial sistêmica (HAS) em adolescentes brasileiros, considerando os procedimentos metodológicos empregados.MÉTODOS:Pesquisa bibliográfica de estudos de prevalência de PAE/HAS em adolescentes de 1995 a 2010. A busca foi realizada nas bases de dados eletrônicos PubMed/Medline, Lilacs, SciELO, Isi e Adolec. Foram utilizados os descritores: hipertensão, pressão arterial, adolescente, estudantes, estudos transversais, prevalência e Brasil, nas línguas portuguesa e inglesa. Além disso, foi elaborado um escore, baseado nas Recommendations for Blood Pressure Measurement in Humans and Experimental Animals e nas VI Diretrizes Brasileiras de Hipertensão, para a análise dos procedimentos utilizados para medida da PA nos estudos variando de 0 a 18.RESULTADOS:Foram identificados 21 artigos, a maioria publicada nos últimos 10 anos, sendo 90,5% realizados em base escolar e nas regiões sudeste, nordeste e sul do país. As prevalências de PAE/HAS variaram de 2,5 a 30,9%. A pontuação dos estudos variou de 0 a 16. Foi observada uma correlação negativa significante (rho = -0,504; p = 0,020) entre a prevalência de PAE/HAS e o escore da qualidade da medida da PA.CONCLUSÃO:A grande variabilidade das estimativas da PAE/HAS parece ser influenciada pelos procedimentos metodológicos utilizados nos estudos.