997 resultados para bispectral index


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To establish the correlation between the bispectral index (BIS) and different rates of infusion of propofol in dogs.Study design Prospective experimental trial.Animals Eight adult dogs weighing 6-20 kg.Methods Eight animals underwent three treatments at intervals of 20 days. Propofol was used for induction of anesthesia (10 mg kg(-1) IV), followed by a continuous rate infusion (CRI) at 0.2 mg kg(-1) minute(-1) (P2), 0.4 mg kg(-1) minute(-1) (P4) or 0.8 mg kg(-1) minute(-1) (P8) for 55 minutes. The BIS values were measured at 10, 20, 30, 40, and 50 minutes (T10, T20, T30, T40, and T50, respectively) after the CRI of propofol was started. Numeric data were submitted to analysis of variance followed by Tukey test (p < 0.05).Results The BIS differed significantly among groups at T40, when P8 was lower than P2 and P4. At T50, P8 was lower than P2. The electromyographic activity (EMG) in P2 and P4 was higher than P8 at T40 and T50.Conclusion An increase in propofol infusion rates decreases the BIS values and EMG.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective-To evaluate the correlation between the bispectral index (BIS) and end-tidal isoflurane (ETISO) concentration and compare the use of 3 BIS sensor positions in dogs.Animals-6 adult dogs.Procedures-Mechanically ventilated dogs received pancuronium, and depth of anesthesia was altered by increasing ETISO concentration from 1.5% to 2.3% and 3.0%. The BIS, suppression ratio (relative percentage of isoelectric electroencephalographic waveforms), and signal quality index (SQI) were recorded at each ET, so concentration for each of 3 BIS sensor positions (frontal-occipital, bifrontal, and frontal-temporal positions).Results-The BIS and ETISO concentration were poorly correlated-, regardless of sensor positioning, mean BIS values did not change significantly as ETISO was increased. At 3% isoflurane, regardless of sensor positioning, there was an increase in suppression ratio coincident with BIS < 40 in some dogs, whereas paradoxic increases in BIS (> 60) were recorded in others. Furthermore, at 3.0% isoflurane, the SQI was significantly lower for the bifrontal sensor position (compared with values for the other positions), but low SQI values prevented recording of BIS values from the frontal-occipital sensor position in 2 dogs. Overall, BIS values derived from the 3 sensor positions did not differ.Conclusions and Clinical Relevance-In dogs, BIS values may not reflect changes in depth of isoflurane anesthesia in the absence of noxious stimulation. of the 3 sensor positions, frontal-temporal positioning provided better correlation with changes in depth of anesthesia induced via changes in isoflurane concentrations. However, the sensor placements yielded similar results at SQI values > 50.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hypnotic depth during anesthesia affects electroencephalography waveforms and electroencephalogram-derived indices, such as the bispectral index (BIS). Titrating anesthetic administration against the BIS assumes reliable relationships between BIS values, electroencephalogram waveforms, and effect site concentration, beyond loss of responsiveness. Associations among BIS, end-tidal anesthetic concentrations (ETAC), and patient characteristics were examined during anesthetic maintenance, using B-Unaware trial data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Sedative and analgesic drugs are frequently used in critically ill patients. Their overuse may prolong mechanical ventilation and length of stay in the intensive care unit. Guidelines recommend use of sedation protocols that include sedation scores and trials of sedation cessation to minimize drug use. We evaluated processed electroencephalography (response and state entropy and bispectral index) as an adjunct to monitoring effects of commonly used sedative and analgesic drugs and intratracheal suctioning. METHODS: Electrodes for monitoring bispectral index and entropy were placed on the foreheads of 44 critically ill patients requiring mechanical ventilation and who previously had no brain dysfunction. Sedation was targeted individually using the Ramsay Sedation Scale, recorded every 2 hours or more frequently. Use of and indications for sedative and analgesic drugs and intratracheal suctioning were recorded manually and using a camera. At the end of the study, processed electroencephalographical and haemodynamic variables collected before and after each drug application and tracheal suctioning were analyzed. Ramsay score was used for comparison with processed electroencephalography when assessed within 15 minutes of an intervention. RESULTS: The indications for boli of sedative drugs exhibited statistically significant, albeit clinically irrelevant, differences in terms of their association with processed electroencephalographical parameters. Electroencephalographical variables decreased significantly after bolus, but a specific pattern in electroencephalographical variables before drug administration was not identified. The same was true for opiate administration. At both 30 minutes and 2 minutes before intratracheal suctioning, there was no difference in electroencephalographical or clinical signs in patients who had or had not received drugs 10 minutes before suctioning. Among patients who received drugs, electroencephalographical parameters returned to baseline more rapidly. In those cases in which Ramsay score was assessed before the event, processed electroencephalography exhibited high variation. CONCLUSIONS: Unpleasant or painful stimuli and sedative and analgesic drugs are associated with significant changes in processed electroencephalographical parameters. However, clinical indications for drug administration were not reflected by these electroencephalographical parameters, and barely by sedation level before drug administration or tracheal suction. This precludes incorporation of entropy and bispectral index as target variables for sedation and analgesia protocols in critically ill patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Sedation protocols, including the use of sedation scales and regular sedation stops, help to reduce the length of mechanical ventilation and intensive care unit stay. Because clinical assessment of depth of sedation is labor-intensive, performed only intermittently, and interferes with sedation and sleep, processed electrophysiological signals from the brain have gained interest as surrogates. We hypothesized that auditory event-related potentials (ERPs), Bispectral Index (BIS), and Entropy can discriminate among clinically relevant sedation levels. METHODS: We studied 10 patients after elective thoracic or abdominal surgery with general anesthesia. Electroencephalogram, BIS, state entropy (SE), response entropy (RE), and ERPs were recorded immediately after surgery in the intensive care unit at Richmond Agitation-Sedation Scale (RASS) scores of -5 (very deep sedation), -4 (deep sedation), -3 to -1 (moderate sedation), and 0 (awake) during decreasing target-controlled sedation with propofol and remifentanil. Reference measurements for baseline levels were performed before or several days after the operation. RESULTS: At baseline, RASS -5, RASS -4, RASS -3 to -1, and RASS 0, BIS was 94 [4] (median, IQR), 47 [15], 68 [9], 75 [10], and 88 [6]; SE was 87 [3], 46 [10], 60 [22], 74 [21], and 87 [5]; and RE was 97 [4], 48 [9], 71 [25], 81 [18], and 96 [3], respectively (all P < 0.05, Friedman Test). Both BIS and Entropy had high variabilities. When ERP N100 amplitudes were considered alone, ERPs did not differ significantly among sedation levels. Nevertheless, discriminant ERP analysis including two parameters of principal component analysis revealed a prediction probability PK value of 0.89 for differentiating deep sedation, moderate sedation, and awake state. The corresponding PK for RE, SE, and BIS was 0.88, 0.89, and 0.85, respectively. CONCLUSIONS: Neither ERPs nor BIS or Entropy can replace clinical sedation assessment with standard scoring systems. Discrimination among very deep, deep to moderate, and no sedation after general anesthesia can be provided by ERPs and processed electroencephalograms, with similar P(K)s. The high inter- and intraindividual variability of Entropy and BIS precludes defining a target range of values to predict the sedation level in critically ill patients using these parameters. The variability of ERPs is unknown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Critically ill and injured patients require pain relief and sedation to reduce the body's stress response and to facilitate painful diagnostic and therapeutic procedures. Presently, the level of sedation and analgesia is guided by the use of clinical scores which can be unreliable. There is therefore, a need for an objective measure of sedation and analgesia. The Bispectral Index (BIS) and Patient State Index (PSI) were recently introduced into clinical practice as objective measures of the depth of analgesia and sedation. ^ Aim. To compare the different measures of sedation and analgesia (BIS and PSI) to the standard and commonly used modified Ramsay Score (MRS) and determine if the monitors can be used interchangeably. ^ Methods. MRS, BIS and PSI values were obtained in 50 postoperative cardiac surgery patients requiring analgesia and sedation from June to December 2004. The MRS, BIS and PSI values were assessed hourly for up to 6-h by a single observer. ^ The relationship between BIS and PSI values were explored using scatter plots and correlation between MRS, BIS and PSI was determined using Spearman's correlation coefficient. Intra-class correlation (ICC) was used to determine the inter-rater reliability of MRS, BIS and PSI. Kappa statistics was used to further evaluate the agreement between BIS and PSI at light, moderate and deep levels of sedation. ^ Results. There was a positive correlation between BIS and PSI values (Rho = 0.731, p<0.001). Intra-class correlation between BIS and PSI was 0.58, MRS and BIS 0.43 and MRS and PSI 0.27. Using Kappa statistics, agreement between MRS and BIS was 0.35 (95% CI: 0.27–0.43) and for MRS and PSI was 0.21 (95% CI: 0.15–0.28). The kappa statistic for BIS and PSI was 0.45 (95% CI: 0.37–0.52). Receiver operating characteristics (ROC) curves constructed to detect undersedation indicated an area under the curve (AUC) of 0.91 (95% CI = 0.87 to 0.94) for the BIS and 0.84 (95% CI = 0.79 to 0.88) for the PSI. For detection of oversedation, AUC for the BIS was 0.89 (95% CI = 0.84 to 0.92) and 0.80 (95% CI = 0.75 to 0.85) for the PSI. ^ Conclusions. There is a statistically significant positive correlation between the BIS and PSI but poor correlation and poor test agreement between the MRS and BIS as well as MRS and PSI. Both the BIS and PSI demonstrated a high level of prediction for undersedation and oversedation; however, the BIS and PSI can not be considered interchangeable monitors of sedation. ^

Relevância:

70.00% 70.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: A monitorização da profundidade da hipnose e da anestesia é um ato complexo. A maioria das propostas para monitorizar os níveis adequados da hipnose, durante a anestesia, envolve o EEG usando as ondas do EEG, ou mais recentemente, usando a forma processada. A análise bispectral é o método que permite analisar o EEG nas diferentes fases de freqüências. CONTEÚDO: O EEG processado é iniciado com a conversão do sinal de EEG para a forma digital. O EEG digitalizado pode ser matematicamente transformado pelo processo conhecido como análise de Fourier, que separa o complexo sinal do EEG em vários componentes da onda, ou seja, em cada porção de diferente amplitude, mas cuja soma corresponde à forma original da onda. Com o emprego deste método surgem vários parâmetros. O Índice Bispectral, ou simplesmente BIS (100 - acordado até 0 - isoelétrico), é derivado dos melhores parâmetros (p.ex.: freqüência da borda spectral, freqüência mediana e o burst supression ou surto de supressão) que foram avaliados através de análise estatística. CONCLUSÕES: A experiência clínica tem mostrado que o BIS pode predizer uma resposta à incisão da pele durante a anestesia. Entretanto, o BIS não é independente da técnica anestésica usada. Há diferentes respostas, a depender do hipnótico e analgésico empregado.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The study's objective was to realize comparisons among different acepromazine, chlorpromazine and methotrimeprazine doses, evaluate parametric changes, test analgesia using press and term algimetry, and evaluate bispectral condition. 90 mongrel dogs were used, male and female, adult, weighting 10 to 15 Kg as a rule, distributed in 9 groups with 10 animals each. At first, second and third groups acepromazine was used at 0,1; 0,05 e 0,025 mg/Kg, respectively. At forth, fifth and sixth groups, chlorpromazine was used at 1,0; 0,5 and 0,25 mg/Kg, respectively. At seventh, eighth and ninth groups, methotrimeprazine at 1,0; 0,5 and 0,25 mg/Kg was used, respectively. All drugs were administered intravenously. objects of study: heart rate (HR), non invasive blood pressure (SAP, MAP, DAP), respiratory rate (f), capnography (ETCO(2)), pulse oxymetry (SatO(2)), mouth and rectal temperature, bispectral index (BIS), electromyography (EMG%), press and term algimetry. Somatic analgesia was evaluated by animal's response to nociceptives stimulus. We concluded that chlorpromazine had more bypotension. Dogs showed higher hypnosis level at: chlorpromazine group, with evident myorelaxation. All groups showed analgesia to thermic and mechanic stimulus. Acepromazine group showed high duration to both pain stimuli. Bispectral index was shorten at chlorpromazine group at 1,0 mg/kg doses, showing higher hypnosis index, and acepromazine was the less depressing considering the bispectral index.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Verificar o efeito sedativo da clonidina, um a2-agonista, e do midazolam, um benzodiazepínico, quando utilizados na medicação pré-anestésica, empregando-se avaliação clínica e eletroencefalográfica bispectral. MÉTODO: Após aprovação institucional e consentimento escrito fornecido, 45 pacientes de 18 a 65 anos, estado físico ASA I, foram aleatoriamente distribuídos nos grupos placebo (P), clonidina (C) ou midazolam (M), em que receberam, respectivamente placebo, 150 µg de clonidina ou 15 mg de midazolam por via oral, 60 minutos antes da indução da anestesia (n = 15 por grupo). A monitorização constituiu-se de eletrocardiograma (D II), pressão arterial não invasiva, freqüência cardíaca, saturação de pulso de oxigênio, freqüência respiratória, temperatura axilar e da sala de cirurgia e eletroencefalograma bispectral para determinação do índice bispectral (BIS). Esses atributos e a escala de sedações (1 - ansioso, 2 - calmo, 3 - sonolento, 4 - dormindo com reflexo, 5 - dormindo sem reflexo) foram obtidos aos 0 (M0), 15 (M15), 30 (M30), 40 (M40), 50 (M50) e 60 (M60) minutos após a medicação. RESULTADOS: Nos grupos não houve alteração significante dos parâmetros respiratórios, hemodinâmicos e de temperatura. Houve diferença significante entre os grupos na ES (M60: M=C>P) e no BIS (M50 e M60: M=C>P). CONCLUSÕES: Nas condições utilizadas, a clonidina e o midazolam determinaram níveis de sedação adequados e semelhantes na medicação pré-anestésica de pacientes estado físico ASA I, quando avaliados pela escala de sedação e pelo índice bispectral, sem determinarem alterações hemodinâmicas e respiratórias.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background and Objectives - Sevoflurane is an inhalational anesthetic drug with low blood/gas solubility providing fast anesthesia induction and emergence. Its ability to maintain cardiovascular stability makes it ideal for pediatric anesthesia. The aim of this study was to evaluate hemodynamic stability, consumption of inhalational anesthetics and emergence time in children with and without premedication (midazolam or clonidine) anesthetized with sevoflurane titrated according to BIS monitoring. Methods - Participated in this study 30 patients aged 2 to 12 years, physical status ASA I, undergoing elective surgeries who were divided into 3 groups: G1 - without premedication, G2 - 0.5 mg.kg-1 oral midazolam, G3 - 4 μg.kg-1 oral clonidine 60 minutes before surgery. All patients received 30 μg.kg-1 alfentanil, 3 mg.kg-1 propofol, 0.5 mg.kg-1 atracurium, sevoflurane in different concentrations monitored by BIS (values close to 60) and N2O in a non rebreathing system. Systolic and diastolic blood pressure, heart rate, expired sevoflurane concentration (EC), sevoflurane consumption (ml.min-1) and emergence time were evaluated. Emergence time was defined as time elapsed between the end of anesthesia and patients' spontaneous movements trying to extubate themselves, crying and opening eyes and mouth. Results - There were no differences among groups as to systolic and diastolic blood pressure, EC, sevoflurane consumption and emergence time. Heart rate was lower in G3 group. Conclusions - Sevoflurane has provided hemodynamic stability. Premedication with clonidine and midazolam did not influence emergence time, inhaled anesthetic consumption or maintenance of anesthesia with sevoflurane. Anesthesia duration has also not influenced emergence time. Hypnosis monitoring was important for balancing anesthetic levels and this might have been responsible for the similarity of emergence times for all studied groups.