998 resultados para beam auto-alignment


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A laser beam automatic alignment system is applied in a multipass amplifier of the SG-III prototype laser. Considering the requirements of the SG-III prototype facility, by combining the general techniques of the laser beam automatic alignment system, according to the image relayed of the pinholes in the spatial filter, and utilizing the optical position and the spatial distribution of the four pinholes of the main spatial filter in the multipass amplifier of the SG-III prototype, a reasonable and optimized scheme for automatic aligning multipass beam paths is presented. It is demonstrated on the multipass amplifier experimental system. (C) 2004 Society of Photo-Optical Instrumentation Engineers.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Estimation of the far-field centre is carried out in beam auto-alignment. In this paper, the features of the far-field of a square beam are presented. Based on these features, a phase-only matched filter is designed, and the algorithm of centre estimation is developed. Using the simulated images with different kinds of noise and the 40 test images that are taken in sequence, the accuracy of this algorithm is estimated. Results show that the error is no more than one pixel for simulated noise images with a 99% probability, and the stability is restricted within one pixel for test images. Using the improved algorithm, the consumed time is reduced to 0.049 s.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

针对高功率激光装置四程放大系统的特点,利用矩阵光学原理,建立了四程放大准直系统的数学模型;基于此模型,设计了四程放大系统的准直调整方案;得出了近、远场偏移量与调整量关系的解析解.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

光路自动准直系统应用于惯性约束聚变的高功率激光装置中的光束自动调整。图像处理是光路自动准直的关键技术之一。针对神光Ⅲ原型装置,结合阈值化、重心法、中值滤波和圆拟合等多种不同的图像处理方法设计了一套合理的准直方案,并且在模拟实验平台上进行了实验验证。实验结果表明,光路自动准直系统能够在15min之内顺利完成光路的自动调整,光束近场调整精度优于近场光斑的±0.5%,光束远场调整精度≤±0.3″,满足了原型装置的总体要求。

Relevância:

80.00% 80.00%

Publicador:

Resumo:

利用高功率激光装置空间滤波器小孔成像和取样光栅的衍射,设计出一套新型光路远场监测方案,并且在实验平台上进行了实验验证.实验结果表明:相对传统的远场监测方法,该远场监测系统通过侧面离轴光栅取样灵活利用空间,其调整平均误差为空间滤波器小孔直径0.9%,能够满足准直系统远场调整精度(<小孔直径5%)的要求.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Calibration of a camera system is a necessary step in any stereo metric process. It correlates all cameras to a common coordinate system by measuring the intrinsic and extrinsic parameters of each camera. Currently, manual calibration of a camera system is the only way to achieve calibration in civil engineering operations that require stereo metric processes (photogrammetry, videogrammetry, vision based asset tracking, etc). This type of calibration however is time-consuming and labor-intensive. Furthermore, in civil engineering operations, camera systems are exposed to open, busy sites. In these conditions, the position of presumably stationary cameras can easily be changed due to external factors such as wind, vibrations or due to an unintentional push/touch from personnel on site. In such cases manual calibration must be repeated. In order to address this issue, several self-calibration algorithms have been proposed. These algorithms use Projective Geometry, Absolute Conic and Kruppa Equations and variations of these to produce processes that achieve calibration. However, most of these methods do not consider all constraints of a camera system such as camera intrinsic constraints, scene constraints, camera motion or varying camera intrinsic properties. This paper presents a novel method that takes all constraints into consideration to auto-calibrate cameras using an image alignment algorithm originally meant for vision based tracking. In this method, image frames are taken from cameras. These frames are used to calculate the fundamental matrix that gives epipolar constraints. Intrinsic and extrinsic properties of cameras are acquired from this calculation. Test results are presented in this paper with recommendations for further improvement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

微束辐照装置是将辐照样品的束斑缩小到μm量级,能够对辐照粒子进行准确定位和精确计数的实验平台,是开展辐照材料学、辐照生物学、辐照生物医学和微加工的有力工具。μm量级的束流对设备的准直安装也提出了极高的要求,对于HIRFL系统微束线上的二极磁铁,由于其所在位置的空间相当狭小,使得设计就位时磁铁的位置及角度与地面做基准时的不同,这给安装准直工作带来了挑战。通过引入变化的基准坐标值的办法,有效解决了这一难题,使全部磁铁安装误差都控制在了要求的公差范围之内。

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Significant reduction of inherent large divergence of the laser driven MeV proton beams is achieved by strong (of the order of 10^9 V/m ) electrostatic focussing field generated in the confined region of a suitably shaped structure attached to the proton generating foil. The scheme exploits the positively charging of the target following an intense laser interaction. Reduction in the proton beam divergence, and commensurate increase in proton flux is observed while preserving the beam laminarity. The underlying mechanism has been established by the help of particle tracing simulations. Dynamic focussing power of the lens, mainly due to the target discharging, can also be exploited in order to bring up the desired chromaticity of the lens for the proton beams of broad energy range.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction This investigation aimed to assess the consistency and accuracy of radiation therapists (RTs) performing cone beam computed tomography (CBCT) alignment to fiducial markers (FMs) (CBCTFM) and the soft tissue prostate (CBCTST). Methods Six patients receiving prostate radiation therapy underwent daily CBCTs. Manual alignment of CBCTFM and CBCTST was performed by three RTs. Inter-observer agreement was assessed using a modified Bland–Altman analysis for each alignment method. Clinically acceptable 95% limits of agreement with the mean (LoAmean) were defined as ±2.0 mm for CBCTFM and ±3.0 mm for CBCTST. Differences between CBCTST alignment and the observer-averaged CBCTFM (AvCBCTFM) alignment were analysed. Clinically acceptable 95% LoA were defined as ±3.0 mm for the comparison of CBCTST and AvCBCTFM. Results CBCTFM and CBCTST alignments were performed for 185 images. The CBCTFM 95% LoAmean were within ±2.0 mm in all planes. CBCTST 95% LoAmean were within ±3.0 mm in all planes. Comparison of CBCTST with AvCBCTFM resulted in 95% LoA of −4.9 to 2.6, −1.6 to 2.5 and −4.7 to 1.9 mm in the superior–inferior, left–right and anterior–posterior planes, respectively. Conclusions Significant differences were found between soft tissue alignment and the predicted FM position. FMs are useful in reducing inter-observer variability compared with soft tissue alignment. Consideration needs to be given to margin design when using soft tissue matching due to increased inter-observer variability. This study highlights some of the complexities of soft tissue guidance for prostate radiation therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the design and development of a novel optical vehicle classifier system, which is based on interruption of laser beams, that is suitable for use in places with poor transportation infrastructure. The system can estimate the speed, axle count, wheelbase, tire diameter, and the lane of motion of a vehicle. The design of the system eliminates the need for careful optical alignment, whereas the proposed estimation strategies render the estimates insensitive to angular mounting errors and to unevenness of the road. Strategies to estimate vehicular parameters are described along with the optimization of the geometry of the system to minimize estimation errors due to quantization. The system is subsequently fabricated, and the proposed features of the system are experimentally demonstrated. The relative errors in the estimation of velocity and tire diameter are shown to be within 0.5% and to change by less than 17% for angular mounting errors up to 30 degrees. In the field, the classifier demonstrates accuracy better than 97.5% and 94%, respectively, in the estimation of the wheelbase and lane of motion and can classify vehicles with an average accuracy of over 89.5%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A deformable mirror (DM) is an important component of an adaptive optics system. It is known that an on-axis spherical/parabolic optical component, placed at an angle to the incident beam introduces defocus as well as astigmatism in the image plane. Although the former can be compensated by changing the focal plane position, the latter cannot be removed by mere optical realignment. Since the DM is to be used to compensate a turbulence-induced curvature term in addition to other aberrations, it is necessary to determine the aberrations induced by such (curved DM surface) an optical element when placed at an angle (other than 0 deg) of incidence in the optical path. To this effect, we estimate to a first order the aberrations introduced by a DM as a function of the incidence angle and deformation of the DM surface. We record images using a simple setup in which the incident beam is reflected by a 37 channel micro-machined membrane deformable mirror for various angles of incidence. It is observed that astigmatism is a dominant aberration, which was determined by measuring the difference between the tangential and sagittal focal planes. We justify our results on the basis of theoretical simulations and discuss the feasibility of using such a system for adaptive optics considering a trade-off between wavefront correction and astigmatism due to deformation. (C) 2015 Optical Society of America