Assessment of cone beam CT registration for prostate radiation therapy : fiducial marker and soft tissue methods


Autoria(s): Deegan, Timothy; Owen, Rebecca; Holt, Tanya; Fielding, Andrew; Biggs, Jennifer; Parfitt, Matthew; Coates, Alicia; Roberts, Lisa; ,
Data(s)

22/06/2014

Resumo

Introduction This investigation aimed to assess the consistency and accuracy of radiation therapists (RTs) performing cone beam computed tomography (CBCT) alignment to fiducial markers (FMs) (CBCTFM) and the soft tissue prostate (CBCTST). Methods Six patients receiving prostate radiation therapy underwent daily CBCTs. Manual alignment of CBCTFM and CBCTST was performed by three RTs. Inter-observer agreement was assessed using a modified Bland–Altman analysis for each alignment method. Clinically acceptable 95% limits of agreement with the mean (LoAmean) were defined as ±2.0 mm for CBCTFM and ±3.0 mm for CBCTST. Differences between CBCTST alignment and the observer-averaged CBCTFM (AvCBCTFM) alignment were analysed. Clinically acceptable 95% LoA were defined as ±3.0 mm for the comparison of CBCTST and AvCBCTFM. Results CBCTFM and CBCTST alignments were performed for 185 images. The CBCTFM 95% LoAmean were within ±2.0 mm in all planes. CBCTST 95% LoAmean were within ±3.0 mm in all planes. Comparison of CBCTST with AvCBCTFM resulted in 95% LoA of −4.9 to 2.6, −1.6 to 2.5 and −4.7 to 1.9 mm in the superior–inferior, left–right and anterior–posterior planes, respectively. Conclusions Significant differences were found between soft tissue alignment and the predicted FM position. FMs are useful in reducing inter-observer variability compared with soft tissue alignment. Consideration needs to be given to margin design when using soft tissue matching due to increased inter-observer variability. This study highlights some of the complexities of soft tissue guidance for prostate radiation therapy.

Identificador

http://eprints.qut.edu.au/75146/

Publicador

John Wiley & Sons Inc

Relação

DOI:10.1111/1754-9485.12197

Deegan, Timothy, Owen, Rebecca, Holt, Tanya, Fielding, Andrew, Biggs, Jennifer, Parfitt, Matthew, Coates, Alicia, Roberts, Lisa, & , (2014) Assessment of cone beam CT registration for prostate radiation therapy : fiducial marker and soft tissue methods. Journal of Medical Imaging and Radiation Oncology.

Direitos

Copyright 2014 The Royal Australian and New Zealand College of Radiologists

Fonte

School of Chemistry, Physics & Mechanical Engineering; Institute of Health and Biomedical Innovation; Science & Engineering Faculty

Palavras-Chave #029903 Medical Physics #111208 Radiation Therapy #Cone Beam CT #Image Guided Radiotherapy #Prostate #Fiducial Markers #Image Registration
Tipo

Journal Article