860 resultados para automated external defibrillators


Relevância:

100.00% 100.00%

Publicador:

Resumo:

[ES]La fibrilación ventricular (VF) es el primer ritmo registrado en el 40\,\% de las muertes súbitas por paro cardiorrespiratorio extrahospitalario (PCRE). El único tratamiento eficaz para la FV es la desfibrilación mediante una descarga eléctrica. Fuera del hospital, la descarga se administra mediante un desfibrilador externo automático (DEA), que previamente analiza el electrocardiograma (ECG) del paciente y comprueba si presenta un ritmo desfibrilable. La supervivencia en un caso de PCRE depende fundamentalmente de dos factores: la desfibrilación temprana y la resucitación cardiopulmonar (RCP) temprana, que prolonga la FV y por lo tanto la oportunidad de desfibrilación. Para un correcto análisis del ritmo cardiaco es necesario interrumpir la RCP, ya que, debido a las compresiones torácicas, la RCP introduce artefactos en el ECG. Desafortunadamente, la interrupción de la RCP afecta negativamente al éxito en la desfibrilación. En 2003 se aprobó el uso del DEA en pacientes entre 1 y 8 años. Los DEA, que originalmente se diseñaron para pacientes adultos, deben discriminar de forma precisa las arritmias pediátricas para que su uso en niños sea seguro. Varios DEAs se han adaptado para uso pediátrico, bien demostrando la precisión de los algoritmos para adultos con arritmias pediátricas, o bien mediante algoritmos específicos para arritmias pediátricas. Esta tesis presenta un nuevo algoritmo DEA diseñado conjuntamente para pacientes adultos y pediátricos. El algoritmo se ha probado exhaustivamente en bases de datos acordes a los requisitos de la American Heart Association (AHA), y en registros de resucitación con y sin artefacto RCP. El trabajo comenzó con una larga fase experimental en la que se recopilaron y clasificaron retrospectivamente un total de 1090 ritmos pediátricos. Además, se revisó una base de arritmias de adultos y se añadieron 928 nuevos ritmos de adultos. La base de datos final contiene 2782 registros, 1270 se usaron para diseñar el algoritmo y 1512 para validarlo. A continuación, se diseñó un nuevo algoritmo DEA compuesto de cuatro subalgoritmos. Estos subalgoritmos están basados en un conjunto de nuevos parámetros para la detección de arritmias, calculados en diversos dominios de la señal, como el tiempo, la frecuencia, la pendiente o la función de autocorrelación. El algoritmo cumple las exigencias de la AHA para la detección de ritmos desfibrilables y no-desfibrilables tanto en pacientes adultos como en pediátricos. El trabajo concluyó con el análisis del comportamiento del algoritmo con episodios reales de resucitación. En los ritmos que no contenían artefacto RCP se cumplieron las exigencias de la AHA. Posteriormente, se estudió la precisión del algoritmo durante las compresiones torácicas, antes y después de filtrar el artefacto RCP. Para suprimir el artefacto se utilizó un nuevo método desarrollado a lo largo de la tesis. Los ritmos desfibrilables se detectaron de forma precisa tras el filtrado, los no-desfibrilables sin embargo no.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To assess the impedance cardiogram recorded by an automated external defibrillator during cardiac arrest to facilitate emergency care by lay persons. Lay persons are poor at emergency pulse checks (sensitivity 84%, specificity 36%); guidelines recommend they should not be performed. The impedance cardiogram (dZ/dt) is used to indicate stroke volume. Can an impedance cardiogram algorithm in a defibrillator determine rapidly circulatory arrest and facilitate prompt initiation of external cardiac massage?

DESIGN: Clinical study.

SETTING: University hospital.

PATIENTS: Phase 1 patients attended for myocardial perfusion imaging. Phase 2 patients were recruited during cardiac arrest. This group included nonarrest controls.

INTERVENTIONS: The impedance cardiogram was recorded through defibrillator/electrocardiographic pads oriented in the standard cardiac arrest position.

MEASUREMENTS AND MAIN RESULTS: Phase 1: Stroke volumes from gated myocardial perfusion imaging scans were correlated with parameters from the impedance cardiogram system (dZ/dt(max) and the peak amplitude of the Fast Fourier Transform of dZ/dt between 1.5 Hz and 4.5 Hz). Multivariate analysis was performed to fit stroke volumes from gated myocardial perfusion imaging scans with linear and quadratic terms for dZ/dt(max) and the Fast Fourier Transform to identify significant parameters for incorporation into a cardiac arrest diagnostic algorithm. The square of the peak amplitude of the Fast Fourier Transform of dZ/dt was the best predictor of reduction in stroke volumes from gated myocardial perfusion imaging scans (range = 33-85 mL; p = .016). Having established that the two pad impedance cardiogram system could detect differences in stroke volumes from gated myocardial perfusion imaging scans, we assessed its performance in diagnosing cardiac arrest. Phase 2: The impedance cardiogram was recorded in 132 "cardiac arrest" patients (53 training, 79 validation) and 97 controls (47 training, 50 validation): the diagnostic algorithm indicated cardiac arrest with sensitivities and specificities (+/- exact 95% confidence intervals) of 89.1% (85.4-92.1) and 99.6% (99.4-99.7; training) and 81.1% (77.6-84.3) and 97% (96.7-97.4; validation).

CONCLUSIONS: The impedance cardiogram algorithm is a significant marker of circulatory collapse. Automated defibrillators with an integrated impedance cardiogram could improve emergency care by lay persons, enabling rapid and appropriate initiation of external cardiac massage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Survival from out-of-hospital cardiac arrest depends largely on two factors: early cardiopulmonary resuscitation (CPR) and early defibrillation. CPR must be interrupted for a reliable automated rhythm analysis because chest compressions induce artifacts in the ECG. Unfortunately, interrupting CPR adversely affects survival. In the last twenty years, research has been focused on designing methods for analysis of ECG during chest compressions. Most approaches are based either on adaptive filters to remove the CPR artifact or on robust algorithms which directly diagnose the corrupted ECG. In general, all the methods report low specificity values when tested on short ECG segments, but how to evaluate the real impact on CPR delivery of continuous rhythm analysis during CPR is still unknown. Recently, researchers have proposed a new methodology to measure this impact. Moreover, new strategies for fast rhythm analysis during ventilation pauses or high-specificity algorithms have been reported. Our objective is to present a thorough review of the field as the starting point for these late developments and to underline the open questions and future lines of research to be explored in the following years.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

nterruptions in cardiopulmonary resuscitation (CPR) compromise defibrillation success. However, CPR must be interrupted to analyze the rhythm because although current methods for rhythm analysis during CPR have high sensitivity for shockable rhythms, the specificity for nonshockable rhythms is still too low. This paper introduces a new approach to rhythm analysis during CPR that combines two strategies: a state-of-the-art CPR artifact suppression filter and a shock advice algorithm (SAA) designed to optimally classify the filtered signal. Emphasis is on designing an algorithm with high specificity. The SAA includes a detector for low electrical activity rhythms to increase the specificity, and a shock/no-shock decision algorithm based on a support vector machine classifier using slope and frequency features. For this study, 1185 shockable and 6482 nonshockable 9-s segments corrupted by CPR artifacts were obtained from 247 patients suffering out-of-hospital cardiac arrest. The segments were split into a training and a test set. For the test set, the sensitivity and specificity for rhythm analysis during CPR were 91.0% and 96.6%, respectively. This new approach shows an important increase in specificity without compromising the sensitivity when compared to previous studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Correctly performed basic life support (BLS) and early defibrillation are the most effective measures to treat sudden cardiac arrest. Audiovisual feedback improves BLS. Automated external defibrillators (AED) with feedback technology may play an important role in improving CPR quality. The aim of this simulation study was to investigate if an AED with audiovisual feedback improves CPR parameters during standard BLS performed by trained laypersons.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: The national resuscitation guidelines were published in Finland in 2002 and are based on international guidelines published in 2000. The main goal of the national guidelines, available on the Internet free of charge, is early defibrillation by nurses in an institutional setting. Aim: To study possible changes in cardiopulmonary resuscitation (CPR) practices, especially concerning early defibrillation, nurses and students attitudes of guideline implementation and nurses and students ability to implement the guideline recommendations in clinical practices after publication of the Current Care (CC) guidelines for CPR 2002. Material and methods: CPR practices in Finnish health centres; especially concerning rapid defibrillation programmes, as well as the implementation of CC guidelines for CPR was studied in a mail survey to chief physicians of every health centre in Finland (Study I). The CPR skills using an automated external defibrillator (AED) were compared in a study including Objective stuctured clinical examination (OSCE) of resuscitation skills of nurses and nursing students in Finnish and Swedish hospital and institution (Studies II, III). Attitudes towards CPR-D and CPR guidelines among medical and nursing students and secondary hospital nurses were studied in surveys (Studies IV, V). The nurses receiving different CPR training were compared in a randomized trial including OSCE of CPR skills of nurses in Finnish Hospital (Study VI). Results: Two years after the publication, 40.7% of Finnish health centres used national resuscitation guidelines. The proportion of health centres having at least one AED (66%) and principle of nurse-performed defibrillation without the presence of a physician (42%) had increased. The CPR-D training was estimated to be insufficient regarding basic life support and advanced life support in the majority of health centres (Study I). CPR-D skills of nurses and nursing students in two specific Swedish and Finnish hospitals and institutions (Study II and III) were generally inadequate. The nurses performed better than the students and the Swedish nurses surpassed the Finnish ones. Geriatric nurses receiving traditional CPR-D training performed better than those receiving an Internet-based course but both groups failed to defibrillate within 60 s. Thus, the performance was not satisfactory even two weeks after traditional training (Study VI). Unlike the medical students, the nursing students did not feel competent to perform procedures recommended in the cardiopulmonary resuscitation guidelines including the defibrillation. However, the majority of nursing students felt confident about their ability to perform basic life support. The perceived ability to defibrillate correlated significantly with a positive attitude towards nurse-performed defibrillation and negatively with fear of damaging the patient s heart by defibrillation (Study IV). After the educational intervention, the nurses found their level of CPR-D capability more sufficient than before and felt more confident about their ability to perform defibrillation themselves. A negative attitude toward defibrillation correlated with perceived negative organisational attitudes toward cardiopulmonary resuscitation guidelines. After CPR-D education in the hospital, the majority (64%) of nurses hesitated to perform defibrillation because of anxiety and 27 % hesitated because of fear of injuring the patient. Also a negative personal attitude towards guidelines increased markedly after education (Study V). Conclusions: Although a significant change had occurred in resuscitation practices in primary health care after publication of national cardiopulmonary resuscitation guidelines the participants CPR-D skills were not adequate according to the CPR guidelines. The current way of teaching is unlikely to result in participants being able to perform adequate and rapid CPR-D. More information and more frequent training are needed to diminish anxiety concerning defibrillation. Negative beliefs and attitudes toward defibrillation affect the nursing students and nurses attitudes toward cardiopulmonary resuscitation guidelines. CPR-D education increased the participants self-confidence concerning CPR-D skills but it did not reduce their anxiety. AEDs have replaced the manual defibrillators in most institutions, but in spite of the modern devices the anxiety still exists. Basic education does not provide nursing students with adequate CPR-D skills. Thus, frequent training in the workplace has vital importance. This multi-professional program supported by the administration might provide better CPR-D skills. Distance learning alone cannot substitute for traditional small-group learning, tutored hands-on training is needed to learn practical CPR-D skills. Standardized testing would probably help controlling the quality of learning. Training of group-working skills might improve CPR performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sudden cardiac arrest (CA) is one of the leading causes of death in Europe. It has been estimated that about 40 % of CA victims have ventricular fibrillation (VF) at the time of the first heart rhythm analysis. The treatment for VF is immediate cardiopulmonary resuscitation (CPR) and rapid defibrillation. The automated external defibrillator (AED) and the concept of public access defibrillation (PAD) may be a key to shortening defibrillation delays. Recent studies have shown that PAD programs are associated with high survival rates from VF when devices have been placed in certain risk sites and used by trained laypersons. Today many public places are equipped with AEDs. The purpose of this study was to find new ways of utilizing layperson defibrillation and promote the concept of public access defibrillation (PAD). The study explored the use of AEDs by non-medical first responders in Finland and cabin crew on board a commercial aircraft. A simulated study was performed to explore the role of dispatcher assistance in layperson CPR and defibrillation. A 15-year follow-up study of 59 one-year survivors after successful out-of-hospital resuscitation was performed to evaluate the long-term quality of life of the CA patients. Although there are many AEDs in use by non-medical first responders in Finland, the results of the study showed that there are large variations between individual first response units. This is considered to be caused by the lack of national standards and regulations that would define a full integration of first-responder programmes into the Emergency Medical Services system. The goal of rapid defibrillation in five minutes after the onset of CA is difficult to achieve in Finland due to sparse population and long distances. Local PAD programs may shorten the defibrillation delays. Dispatcher assistance in defibrillation by a layperson not trained to use an AED seems feasible and does not compromise the performance of CPR. In a simulated study, the quality of mouth-to-mouth ventilation performed by laypersons was found to be better after CPR training compared with performance with dispatcher assistance before training. Training was not found to have an influence on the quality of compressions or defibrillation compared with dispatcher assistance of untrained laypersons. The target groups for CPR and defibrillation training need further evaluation. The placements of the AEDs in public areas should be known by the emergency response center and the location should be marked with an international sign. The finding that once a good neurological outcome after CA is achieved, it can be maintained for more than 10 years, encourages further efforts to improve the survival of CA patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A desfibrilação precoce na ressuscitação cardiopulmonar (RCP) recebe crescente destaque quanto à prioridade e rapidez. Este é um relato de experiência da implantação de um programa de capacitação em RCP, utilizando o desfibrilador em uma universidade privada. O programa em manobras básicas de RCP foi baseado nas diretrizes mundiais, envolvendo um curso teórico com demonstração prática das manobras de RCP com desfibrilador, treinamento prático individual, avaliação teórica e prática. Quanto ao desempenho dos alunos na avaliação prática, a média das pontuações obtidas pelos alunos na 1ª Etapa foi de 26,4 pontos e na 2ª Etapa a média aumentou para 252,8 pontos, já na Avaliação teórica na 1ª Etapa foi de 3,06 pontos e na 2ª Etapa a média aumentou para 9,0 pontos. A implantação desse tipo de programas contribui para a aquisição efetiva de conhecimento (teórico) e da habilidade (prática) nos atendimentos a vítimas de PCR.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aims The effects of a system based on minimally trained first responders (FR) dispatched simultaneously with the emergency medical services (EMS) of the local hospital in a mixed urban and rural area in Northwestern Switzerland were examined. Methods and results In this prospective study 500 voluntary fire fighters received a 4-h training in basic-life-support using automated-external-defibrillation (AED). FR and EMS were simultaneously dispatched in a two-tier rescue system. During the years 2001–2008, response times, resuscitation interventions and outcomes were monitored. 1334 emergencies were included. The FR reached the patients (mean age 60.4 ± 19 years; 65% male) within 6 ± 3 min after emergency calls compared to 12 ± 5 min by the EMS (p < 0.0001). Seventy-six percent of the 297 OHCAs occurred at home. Only 3 emergencies with resuscitation attempts occurred at the main railway station equipped with an on-site AED. FR were on the scene before arrival of the EMS in 1166 (87.4%) cases. Of these, the FR used AED in 611 patients for monitoring or defibrillation. CPR was initiated by the FR in 164 (68.9% of 238 resuscitated patients). 124 patients were defibrillated, of whom 93 (75.0%) were defibrillated first by the FR. Eighteen patients (of whom 13 were defibrillated by the FR) were discharged from hospital in good neurological condition. Conclusions Minimally trained fire fighters integrated in an EMS as FR contributed substantially to an increase of the survival rate of OHCAs in a mixed urban and rural area.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We describe a case of ventricular fibrillation occurring in a patient with multi-vessel coronary spasm after the initiation of an oral beta-blocker. A 56-year-old man began to experience chest discomfort and his computed tomography revealed intermediate coronary stenoses. He was administered medications including an oral beta-blocker but suddenly collapsed while walking 4 days later. An automated external defibrillator detected ventricular fibrillation and delivered successful electrical cardioversion. An acetylcholine provocation test after stabilization of the status revealed triple-vessel coronary spasm. Beta-blockers may provoke exacerbation of coronary spasm and result in lethal arrhythmia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: Nurses and nursing students are often first responders to in-hospital cardiac arrest events; thus they are expected to perform Basic Life Support (BLS) and use an automated external defibrillator (AED) without delay. The aim of this study was to explore the relationship between nursing students’ self-efficacy and performance before and after receiving a particular training intervention in BLS/AED. Materials and methods: Explanatory correlational study. 177 nursing students received a 4-h training session in BLS/AED after being randomized to either a self-directed (SDG) or an instructor-directed teaching group (IDG).1 A validated self-efficacy scale, the Cardiff Test and Laerdal SkillReporter® software were used to assess students’ self-efficacy and performance in BLS/AED at pre-test, post-test and 3-month retention-test. Independent t-test analysis was performed to compare the differences between groups at pre-test. Pearson coefficient (r) was used to calculate the strength of the relationship between self-efficacy and performance in both groups at pre-test, post-test and retention-test. Results: Independent t-tests analysis showed that there were non-significant differences (p-values > 0.05) between groups for any of the variables measured. At pre-test, results showed that correlation between self-efficacy and performance was moderate for the IDG (r = 0.53; p < 0.05) and the SDG (r = 0.49; p < 0.05). At post-test, correlation between self-efficacy and performance was much higher for the SDG (r = 0.81; p < 0.05) than for the IDG (r = 0.32; p < 0.05), which in fact was weaker than at pre-test. Finally, it was found that whereas the correlation between self-efficacy and performance increased from the post-test to the retention-test to almost reach baseline levels for the ILG (r = 0.52; p < 0.05), it slightly decreased in this phase for the SDG (r = 0.77; p < 0.05). Conclusion: Student-directed strategies may be more effective than instructor-directed strategies at promoting self-assessment and, therefore, may help to improve and maintain the relationship between nursing student self-efficacy and actual ability to perform BLS/AED.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The focus of this paper is on the practical aspects of design, prototyping, and testing of a compact, compliant external pipe-crawling robot that can inspect a closely spaced bundle of pipes in hazardous environments and areas that are inaccessible to humans. The robot consists of two radially deployable compliant ring actuators that are attached to each other along the longitudinal axis of the pipe by a bidirectional linear actuator. The robot imitates the motion of an inchworm. The novel aspect of the compliant ring actuator is a spring-steel compliant mechanism that converts circumferential motion to radial motion of its multiple gripping pads. Circumferential motion to ring actuators is provided by two shape memory alloy (SMA) wires that are guided by insulating rollers. The design of the compliant mechanism is derived from a radially deployable mechanism. A unique feature of the design is that the compliant mechanism provides the necessary kinematic function within the limited annular space around the pipe and serves as the bias spring for the SMA wires. The robot has a control circuit that sequentially activates the SMA wires and the linear actuator; it also controls the crawling speed. The robot has been fabricated, tested, and automated. Its crawling speed is about 45 mm/min, and the weight is about 150 g. It fits within an annular space of a radial span of 15 mm to crawl on a pipe of 60-mm outer diameter.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes the development and evaluation of a sequential injection method to automate the determination of methyl parathion by square wave adsorptive cathodic stripping voltammetry exploiting the concept of monosegmented flow analysis to perform in-line sample conditioning and standard addition. Accumulation and stripping steps are made in the sample medium conditioned with 40 mmol L-1 Britton-Robinson buffer (pH 10) in 0.25 mol L-1 NaNO3. The homogenized mixture is injected at a flow rate of 10 mu Ls(-1) toward the flow cell, which is adapted to the capillary of a hanging drop mercury electrode. After a suitable deposition time, the flow is stopped and the potential is scanned from -0.3 to -1.0 V versus Ag/AgCl at frequency of 250 Hz and pulse height of 25 mV The linear dynamic range is observed for methyl parathion concentrations between 0.010 and 0.50 mgL(-1), with detection and quantification limits of 2 and 7 mu gL(-1), respectively. The sampling throughput is 25 h(-1) if the in line standard addition and sample conditioning protocols are followed, but this frequency can be increased up to 61 h(-1) if the sample is conditioned off-line and quantified using an external calibration curve. The method was applied for determination of methyl parathion in spiked water samples and the accuracy was evaluated either by comparison to high performance liquid chromatography with UV detection, or by the recovery percentages. Although no evidences of statistically significant differences were observed between the expected and obtained concentrations, because of the susceptibility of the method to interference by other pesticides (e.g., parathion, dichlorvos) and natural organic matter (e.g., fulvic and humic acids), isolation of the analyte may be required when more complex sample matrices are encountered. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECT: Preliminary experience with the C-Port Flex-A Anastomosis System (Cardica, Inc.) to enable rapid automated anastomosis has been reported in coronary artery bypass surgery. The goal of the current study was to define the feasibility and safety of this method for high-flow extracranial-intracranial (EC-IC) bypass surgery in a clinical series. METHODS: In a prospective study design, patients with symptomatic carotid artery (CA) occlusion were selected for C-Port-assisted high-flow EC-IC bypass surgery if they met the following criteria: 1) transient or moderate permanent symptoms of focal ischemia; 2) CA occlusion; 3) hemodynamic instability; and 4) had provided informed consent. Bypasses were done using a radial artery graft that was proximally anastomosed to the superficial temporal artery trunk, the cervical external, or common CA. All distal cerebral anastomoses were performed on M2 branches using the C-Port Flex-A system. RESULTS: Within 6 months, 10 patients were enrolled in the study. The distal automated anastomosis could be accomplished in all patients; the median temporary occlusion time was 16.6+/-3.4 minutes. Intraoperative digital subtraction angiography (DSA) confirmed good bypass function in 9 patients, and in 1 the anastomosis was classified as fair. There was 1 major perioperative complication that consisted of the creation of a pseudoaneurysm due to a hardware problem. In all but 1 case the bypass was shown to be patent on DSA after 7 days; furthermore, in 1 patient a late occlusion developed due to vasospasm after a sylvian hemorrhage. One-week follow-up DSA revealed transient asymptomatic extracranial spasm of the donor artery and the radial artery graft in 1 case. Two patients developed a limited zone of infarction on CT scanning during the follow-up course. CONCLUSIONS: In patients with symptomatic CA occlusion, C-Port Flex-A-assisted high-flow EC-IC bypass surgery is a technically feasible procedure. The system needs further modification to achieve a faster and safer anastomosis to enable a conclusive comparison with standard and laser-assisted methods for high-flow bypass surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aneurysm diameter measurement is quick and easy, but suffers from the pitfalls of being "too rough and ready". When semi-automated segmentation took 7-10 minutes to estimate volume, it was not a practical tool for busy, routine clinical practice. Today, the availability of automatic segmentation in seconds is bound to make volume measurement, along with 3D ultrasonography, the tools of the future. There can be no debate.