930 resultados para auditory evoked potential


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Behavioral and electrophysiological auditory evaluations contribute to the understanding of the auditory system and of the process of intervention. OBJECTIVE: To study P300 in subjects with severe or profound sensorineural hearing loss. METHODS: This was a descriptive cross-sectional prospective study. It included 29 individuals of both genders with severe or profound sensorineural hearing loss without other type of disorders, aged 11 to 42 years; all were assessed by behavioral audiological evaluation and auditory evoked potentials. RESULTS: A recording of the P3 wave was obtained in 17 individuals, with a mean latency of 326.97 ms and mean amplitude of 3.76 V. There were significant differences in latency in relation to age and in amplitude according to degree of hearing loss. There was a statistically significant association of the P300 results with the degrees of hearing loss (p = 0.04), with the predominant auditory communication channels (p < 0.0001), and with time of hearing loss. CONCLUSIONS: P300 can be recorded in individuals with severe and profound congenital sensorineural hearing loss; it may contribute to the understanding of cortical development and is a good predictor of the early intervention outcome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Contrast sensitivity (CS) was evaluated in 41 former workers from a lamp manufacturing plant who were on disability retirement due to exposure to mercury and 14 age-matched controls. The CS was measured monocularly using the sweep visual evoked potential (sVEP) paradigm at 6 spatial frequencies (0.2, 0.8, 2.0, 4.0, 15.0, and 30 cpd). Statistical difference (p < 0.05) was found between the controls and the patient right and left eyes for 2.0 and 4.0 cpd. According the results in those spatial frequencies the eyes were classified in best and worst. Statistical differences were found between the controls and the best eyes for 2.0 and 4.0 cpd and for 0.8, 2.0, and 4.0 cpd for their worst eyes. No correlation was found between CS results and the time of exposure (mean 8.9 yr +/- 4.1), time away from the mercury source (mean = 6.0 yr +/- 3.9), urinary mercury level at the time of work (mean = 40.6 mu g/g +/-36.3) or with the mercury level at the CS measurement time (mean = 1.6 mu g/g +/-1.1). We show the first evidence of a permanent impairment in CS measured objectively with the sVEP. Our data complement the previous psychophysical works reporting a diffuse impairment in the CS function showing a CS reduction in the low to middle spatial frequencies. In conclusion, non-reversible CS impairment was found in occupational exposure to mercury vapor. We suggest that CS measurement should be included in studies of the mercury effects of occupational exposure. (C) 2007 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Amazonian gold mining activity results in human exposure to mercury vapor. We evaluated the visual system of two Amazonian gold miners (29 and 37 years old) by recording the transient pattern electroretinogram (tPERG) and transient pattern visual evoked potential (tPVEP). We compared these results with those obtained from a regional group of control subjects. For both tPERG and tPVEP, checkerboards with 0.5 or 2 cycles per degree (cpd) of spatial frequency were presented in a 16 degrees squared area, 100% Michelson contrast, 50cd/m(2) mean luminance, and 1 Hz square-wave pattern-reversal presentation. Two averaged waveforms (n = 240 sweeps, Is each) were monocularly obtained for each subject in each condition. Both eyes were monocularly tested only in gold miners. Normative data were calculated using a final pooled waveforin with 480 sweeps. The first gold miner, LCS, had normal tPERG responses. The second one, RNP, showed low tPERG (P50 component) amplitudes at 0.5cpd for both eyes, outside the normative data, and absence of response at 2 cpd for his right eye. Delayed tPVEP responses (P 100 component) were found at 2 cpd for LCS but the implicit times were inside the normative data. Subject RNP also showed delayed tPVEP responses (all components), but only the implicit time obtained with his right eye was outside the normative data at 2cpd. We conclude that mercury exposure levels found in the Amazon gold miners is high enough to damage the visual system and can be assessed by non-invasive electrophysiological techniques. (C) 2007 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

There are several electrophysiological systems available commercially. Usually, control groups are required to compare their results, due to the differences between display types. Our aim was to examine the differences between CRT and LCD/TFT stimulators used in pattern VEP responses performed according to the ISCEV standards. We also aimed to check different contrast values toward thresholds. In order to obtain more precise results, we intended to measure the intensity and temporal response characteristics of the monitors with photometric methods. To record VEP signals, a Roland RetiPort electrophysiological system was used. The pattern VEP tests were carried out according to ISCEV protocols on a CRT and a TFT monitor consecutively. Achromatic checkerboard pattern was used at three different contrast levels (maximal, 75, 25%) using 1A degrees and 15` check sizes. Both CRT and TFT displays were luminance and contrast matched, according to the gamma functions based on measurements at several DAC values. Monitor-specific luminance parameters were measured by means of spectroradiometric instruments. Temporal differences between the displays` electronic and radiometric signals were measured with a device specifically built for the purpose. We tested six healthy control subjects with visual acuity of at least 20/20. The tests were performed on each subject three times on different days. We found significant temporal differences between the CRT and the LCD monitors at all contrast levels and spatial frequencies. In average, the latency times were 9.0 ms (+/- 3.3 ms) longer with the TFT stimulator. This value is in accordance with the average of the measured TFT input-output temporal difference values (10.1 +/- A 2.2 ms). According to our findings, measuring the temporal parameters of the TFT monitor with an adequately calibrated measurement setup and correcting the VEP data with the resulting values, the VEP signals obtained with different display types can be transformed to be comparable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We used an assembly of electrodes C3 and C4-Cz in order to activate the motor cortical area of the corticobulbar tract to elucidate the motor-evoked potential of the contralateral mentalis muscle. We compared this setup to that of an assembly with electrodes C5 or C6-Cz using a train of electrical pulses and a single electrical pulse. This analysis was made in 23 consecutive patients who underwent several varied surgeries and were prospectively operated on at Santa Paula Hospital between January and June 2011. The results showed that the assembly with C5 or C6-Cz produced a multisynaptic motor-evoked potential in the contralateral mentalis muscle in 86.9 % of the patients, whereas 82.6 % of patients stimulated at points C3 or C4-Cz presented the same response. However, both assemblies showed similar behavior with the use of a single electrical pulse for peripheral contralateral nerve stimulation. We concluded that the C5 or C6-Cz assembly was similar to C3 or C4-Cz in obtaining a multisynaptic response in the contralateral mentalis muscle, although it required less intensive stimulation than the C3 or C4- Cz assembly.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objectives: To establish normative amplitude values for relative difference measurements of the middle latency response (MLR) in normal-hearing pediatrics and to determine if these measurements provided a significant reduction of within-group variability when compared to raw, absolute amplitude measures. A relative amplitude difference is defined in the present paper as the difference in Na-Pa amplitude between two electrodes (e.g. vertical bar Na-Pa at C3 minus Na-Pa at C4 vertical bar, or electrode effects) or between two ears (e.g. vertical bar Na-Pa on left ear stimulation minus Na-Pa on right ear stimulation vertical bar, or ear effects). In contrast, an absolute amplitude is defined as a single Na-Pa measurement made at one electrode for stimulation of one ear (e.g. Na-Pa measured at C3 on left ear stimulation). Design: Cross-sectional study. Study sample: 155 pediatrics with normal peripheral and central hearing, and no history of psychological, neurological, or learning disability issues. Results: Within-group variability was significantly smaller for relative differences when compared to absolute amplitude measures. Electrode effects showed significantly less variability than ear effects. Normative values for ear and electrode effects were reported. Conclusions: Relative differences may provide better utility in the clinical diagnosis of central auditory pathology in pediatrics when compared to absolute amplitude measures because these difference measures show significantly lower variability when examined across subjects.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Increased, decreased or normal excitability to transcranial magnetic stimulation (TMS) has been reported in the motor (M1) and visual cortices of patients with migraine. Light deprivation (LD) has been reported to modulate M1 excitability in control subjects (CS). Still, effects of LD on M1 excitability compared to exposure to environmental light exposure (EL) had not been previously described in patients with migraine (MP). To further our knowledge about differences between CS and MP, regarding M1 excitability and effects of LD on M1 excitability, we opted for a novel approach by extending measurement conditions. We measured motor thresholds (MTs) to TMS, short-interval intracortical inhibition, and ratios between motor-evoked potential amplitudes and supramaximal M responses in MP and CS on two different days, before and after LD or EL. Motor thresholds significantly increased in MP in LD and EL sessions, and remained stable in CS. There were no significant between-group differences in other measures of TMS. Short-term variation of MTs was greater in MP compared to CS. Fluctuation in excitability over hours or days in MP is an issue that, until now, has been relatively neglected. The results presented here will help to reconcile conflicting observations.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The harm upon the central auditory pathways of workers exposed to occupational noise has been scarcely studied. Objective: To assess the central auditory pathways by testing the long latency auditory evoked potentials (P300) of individuals exposed to occupational noise and controls. Method: This prospective study enrolled 25 individuals with normal hearing thresholds. The subjects were divided into two groups: individuals exposed to occupational noise (13 subjects; case group) and individuals not exposed to occupational noise (12 subjects; control group). The P300 test was used with verbal and non-verbal stimuli. Results: No statistically significant differences were found between ears for any of the stimuli or between groups. The groups had no statistically significant difference for verbal or non-verbal stimuli. Case group subjects had longer latencies than controls. In qualitative analysis, a greater number of altered P300 test results for verbal and non-verbal stimuli was seen in the case group, despite the absence of statistically significant differences between case and control subjects. Conclusion: Individuals exposed to high sound pressure levels had longer P300 latencies in verbal and non-verbal stimuli when compared to controls.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUÇÃO: Trata-se de uma semiologia laboratorial objetiva para avaliação do sistema auditivo de crianças com distúrbio de aprendizagem. OBJETIVO: Examinar os componentes do potencial evocado auditivo de média latência em uma amostra de crianças com distúrbio de aprendizagem e determinar suas propriedades. MÉTODO: O estudo realizado é do tipo prospectivo contemporâneo de corte transversal, quantitativo, descritivo e exploratório. 50 crianças de ambos os sexos com 8 a 14 anos de idade dividido em dois grupos iguais, com e sem distúrbio de aprendizagem. Causas orgânicas, ambientais ou genéticas foram excluídas do estudo. RESULTADOS E CONCLUSÃO: As ondas Na, Pa, Nb foram identificadas em todos os integrantes do estudo. Os valores de latência dos componentes foram Na= 19,2 ms, Pa= 32,5 ms, Nb= 46,4 ms (grupo controle) e Na= 19,7 ms, Pa= 35,1 ms, Nb= 49,6 ms (grupo pesquisa). O valor médio de amplitude Na-Pa foi 1,4 mV para ambos os grupos. As análises mostraram diferenças funcionais entre os grupos, foi observado o hemisfério esquerdo Nb latência mais longa de Nb no hemisfério esquerdo do grupo de estudo em relação ao controle. Tal estudo promoveu informações adicionais sobre PEAML e pode ser referência para outros estudos clínicos e experimentais nesta população.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To investigate the occurrence of hearing loss in individuals with HIV/AIDS and their characterization regarding type and degree. RESEARCH STRATEGY: It was conducted a systematic review of the literature found on the electronic databases PubMed, EMBASE, ADOLEC, IBECS, Web of Science, Scopus, Lilacs and SciELO. SELECTION CRITERIA: The search strategy was directed by a specific question: "Is hearing loss part of the framework of HIV/AIDS manifestations?", and the selection criteria of the studies involved coherence with the proposed theme, evidence levels 1, 2 or 3, and language (Portuguese, English and Spanish). DATA ANALYSIS: We found 698 studies. After an analysis of the title and abstract, 91 were selected for full reading. Out of these, 38 met the proposed criteria and were included on the review. RESULTS: The studies reported presence of conductive, sensorineural, and mixed hearing loss, of variable degrees and audiometric configurations, in addition to tinnitus and vestibular disorders. The etiology can be attributed to opportunistic infections, ototoxic drugs or to the action of virus itself. The auditory evoked potentials have been used as markers of neurological alterations, even in patients with normal hearing. CONCLUSION: HIV/AIDS patients may present hearing loss. Thus, programs for prevention and treatment of AIDS must involve actions aimed at auditory health.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Das Glaukom ist eine der führenden Erblindungsursachen weltweit. Trotzdem ist die Pathogenese, die zur Degeneration der retinalen Ganglienzellen führt, bisher nicht verstanden. In den letzten Jahren ergaben sich verschiedene Hinweise auf die Beteiligung einer immunologischen Komponente. Thema dieser Arbeit waren elektrophysiologische Untersuchungen, im Sinne von visuell evozierten Potentialen, am Tiermodell des Experimentellen Autoimmun Glaukoms und die Etablierung dieses Modells. Das Modell basiert auf einer Immunisierung von Lewisratten mit Pertussistoxin, inkompletten Freunds Adjuvant und potentiellen Antigenen, die zu einer Immunreaktion und einem Verlust von retinalen Ganglienzellen führen sollen. Zur Etablierung des Experimentellen Autoimmun Glaukom Modells wurde eine fünfwöchige Studie mit vier Gruppen durchgeführt. Als Antigene wurden Glia fibrilläres saures Protein (n= 10) und Myelin basisches Protein (n=10) verwendet, die beide in Studien zu Serum- und Kammerwasseranalysen bei Glaukompatienten eine Abweichung zur Kontrollgruppe gezeigt hatten. Außerdem wurde eine Gruppe mit selbst hergestelltem Sehnerv-Homogenat (n=12) immunisiert. Eine Gruppe erhielt keine Immunisierung und diente als Kontrolle (n=10). Zur Überprüfung der Effekte des Modells dienten verschiedene Untersuchungsmethoden, wie die Augeninnendruckmessung und die Untersuchung der Fundi. Des Weiteren wurden transiente und stationäre visuell evozierte Potentiale abgeleitet und die Latenzen, Amplituden und die Marker S (Steigung) und TR (Temporale Antworten) verglichen. Außerdem erfolgte nach Tötung der Tiere die Entnahme der Gehirne und Augen. Die Gehirne wurden nach Paraffineinbettung geschnitten, mit Luxol Fast Blue und Kresylviolett gefärbt und hinsichtlich etwaiger Entmarkungsherde oder anderer Pathologien unter dem Mikroskop bewertet. Der Verlauf des intraokulären Drucks zeigte sowohl zwischen den Gruppen als auch zwischen den verschiedenen Zeitpunkten keine signifikanten Unterschiede. Er bewegte sich im physiologischen Bereich mit durchschnittlich circa 12 mmHg. Die Funduskopien lieferten zu keinem Zeitpunkt krankhafte Veränderungen. Auch die visuell evozierten Potentiale lieferten zwischen den Gruppen keine signifikanten Unterschiede, sondern belegten normale visuelle Funktion bei allen Tieren. Die Auswertung der histologischen Untersuchung der Hirnschnitte zeigte keine Entmarkungsherde. Die erzielten Ergebnisse dieser Arbeit legen nahe, dass der retinale Ganglienzellverlust beim Experimentellen Autoimmun Glaukom Modell ohne eine Augeninnendruckerhöhung stattfindet. Die Fundusuntersuchung und die visuell evozierten Potentiale, wie in diesem Versuchsaufbau durchgeführt, scheinen nicht sensibel genug zu sein, diese Verluste nachzuweisen. In weiteren Arbeiten sollten andere Methoden zum Nachweis der retinalen Ganglienzellverluste erprobt werden. Neben elektrophysiologischen Methoden bieten sich für das weitere Vorgehen besonders immunhistologische Methoden an. Außerdem sollten die Mechanismen erforscht werden durch die es nach der Immunisierung zur Apoptose von retinalen Ganglienzellen kommt und welche Antikörper dazuführen können. Des Weiteren ist von Interesse, ob und wie eine zelluläre Komponente an der Pathogenese des Experimentellen Autoimmun Glaukoms beteiligt ist.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Although non-organic hearing losses are relatively rare, it is important to identify suspicious findings early to be able to administer specific tests, such as objective measurements and specific counseling. In this retrospective study, we searched for findings that were specific ti or typical for non-organic hearing losses. Patient records from a 6 year period (2003-2008) from the University ENT Department of Bern, Switzerland, were reviewed. In this period, 40 subjects were diagnosed with a non-organic hearing loss (22 children, ages 7-16, mean 10.6 years; 18 adults, ages 19-57, mean 39.7 years; 25 females and 15 males). Pure tone audiograms in children and adults showed predominantly sensorineural and frequency-independent hearing losses, mostly in the range of 40-60 dB. In all cases, objective measurements (otoacoustic emissions and/or auditory-evoked potentials) indicated normal or substantially better hearing thresholds than those found in pure tone audiometry. In nine subjects (22.5%; 2 children, 7 adults), hearing aids had been fitted before the first presentation at our center. Six children (27%) had a history of middle ear problems with a transient hearing loss and 11 (50%) knew a person with a hearing loss. Two new and hitherto unreported findings emerged from the analysis: it was observed that a small air-bone gap of 5-20 dB was typical for non-organic hearing losses and that speech audiometry might show considerably poorer results than expected from pure tone audiometry.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Microsurgery within eloquent cortex is a controversial approach because of the high risk of permanent neurological deficit. Few data exist showing the relationship between the mapping stimulation intensity required for eliciting a muscle motor evoked potential and the distance to the motor neurons; furthermore, the motor threshold at which no deficit occurs remains to be defined.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Hallucinations are perceptions in the absence of a corresponding external sensory stimulus. However, during auditory verbal hallucinations, activation of the primary auditory cortex has been described. AIMS: The objective of this study was to investigate whether this activation of the auditory cortex contributes essentially to the character of hallucinations and attributes them to alien sources, or whether the auditory activation is a sign of increased general auditory attention to external sounds. METHOD: The responsiveness of the auditory cortex was investigated by auditory evoked potentials (N100) during the simultaneous occurrence of hallucinations and external stimuli. Evoked potentials were computed separately for periods with and without hallucinations; N100 power, topography and brain electrical sources were analysed. RESULTS: Hallucinations lowered the N100 amplitudes and changed the topography, presumably due to a reduced left temporal responsivity. CONCLUSIONS: This finding indicates competition between auditory stimuli and hallucinations for physiological resources in the primary auditory cortex. The abnormal activation of the primary auditory cortex may thus be a constituent of auditory hallucinations.