998 resultados para attachment system
Resumo:
The aim of this article is to describe a successful clinical protocol for prosthodontic rehabilitation of a patient with a skeletal Class III malocclusion using a fixed-detachable maxillary prosthesis supported by 6 implants and the MK1 attachment system. The patient was followed up for 8 years. A 46-year-old edentulous woman with a skeletal Class III malocclusion expressed dissatisfaction with her old existing maxillary denture from an esthetic point of view and frustration regarding its function. A fixed-detachable maxillary prosthesis using the MK1 attachment system was made. The patient was followed up clinically and radiographically for 8 years. No bone loss, fracture of prosthetic components, or fracture of the prosthesis was detected in that period. A fixed detachable maxillary prosthesis using the MK1 attachment system is a treatment option for patients with Class III malocclusions who opt not to undergo orthognathic surgery.
Resumo:
Thesis (Master's)--University of Washington, 2016-08
Resumo:
Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.
Resumo:
There are many factors contributing to individual variations in the response to stressful experiences. The present study evaluated the patterns of stress responses according to attachment representations in 28 adults from a community sample, plus 46 subjects expected to be particularly sensitive to stress, having been exposed during childhood and/or adolescence to traumatizing events such as abuse or potentially lethal illnesses. Subjects were given the Adult Attachment Interview, which provides attachment classifications, and the Trier Social Stress Test (TSST), involving an experimental psychosocial challenge. Subjective responses to the TSST, as well as saliva samples (assayed for cortisol) and blood plasma samples (assayed for ACTH and oxytocin) were collected before, during and after the stress procedure. The stress responses presented specific patterns according to attachment classifications. Subjects with an autonomous attachment classification reported relatively low subjective stress, they presented a moderate response of the hypothalamic-pituitary-adrenal (HPA) axis (ACTH and cortisol), and a high level of oxytocin. Subjects with a dismissing classification reported a moderate subjective stress, they presented an elevated response of the HPA axis, and moderate levels of oxytocin. Subjects with a preoccupied classification presented moderate levels of subjective stress, and of HPA response, and a relatively low level of oxytocin. Finally, subjects with an unresolved classification reported elevated subjective stress; they presented a suppressed HPA response, and moderate levels of oxytocin. These data support the notion that attachment representations may affect stress responses, and suggest a specific role of oxytocin in both the attachment system and the stress system.
Resumo:
This finite element analysis compared stress distribution on complete dentures and implant-retained overdentures with different attachment systems. Four models of edentulous mandible were constructed: group A (control), complete denture; group B, overdenture retained by 2 splinted implants with bar-clip system; group C, overdenture retained by 2 unsplinted implants with o'ring system; and group D, overdenture retained by 2 splinted implants with bar-clip and 2 distally placed o'ring system. Evaluation was performed on Ansys software, with 100-N vertical load applied on central incisive teeth. The lowest maximum general stress value (in megapascal) was observed in group A (64.305) followed by groups C (119.006), D (258.650), and B (349.873). The same trend occurred it) supporting tissues with the highest stress value for cortical bone. Unsplinted implants associated with the o'ring attachment system showed the lowest maximum stress values among all overdenture groups. Furthermore, o'ring system also improved stress distribution when associated with bar-clip system.
Resumo:
Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.
Resumo:
Objective: Surgical reconstruction and prosthetic obturation are alternatives for the treatment of cleft in the soft palate.Design: The present case reports the rehabilitation of a patient presenting cleft palate with obturator prosthesis associated with implant-supported retention system.Conclusions: The use of ball attachment system improved speech, masticatory efficiency, swallowing, and social behavior of the patient.
Resumo:
Complete and partial loss of maxillary bone may jeopardize oral physiology and generate complications as oral-sinus-nasal communication. Palatal obturator prostheses are a treatment alternative for rehabilitation of these patients. The aim of this study was to assess stress distribution, through photoelasticity, on palatal obturator prostheses associated with different attachment systems (o'ring, bar clip, and o'ring/bar clip) of implants and submitted to relining. Two photoelastic models were fabricated according to an experimental maxillary model with oral-sinus-nasal communication. One model did not present implants, whereas the other included 2 implants with 13.0 mm in length in the left ridge. Four colorless maxillary obturator prostheses were fabricated and relined with soft silicone. One of these prostheses presented no attachment system, whereas the remaining prostheses included attachment systems adapted to the implants. The assembly (model/attachment system/prosthesis) was positioned in a circular polariscope during loading with 100 N at 10 mm/s. The results were based on observation during the experiment and photographic records of stress on the photoelastic model. The bar clip system exhibited the highest stress concentration followed by o'ring/bar clip and o'ring systems. The attachment systems presented different stress distribution with greater concentration surrounding the implants and homogenous stress distribution on the photoelastic model without implants. The highest concentration of fringes occurred, in ascending order, with o'ring, o'ring/bar clip, and bar clip systems.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
P>This study assessed the effect of simulated mastication on the retention of two stud attachment systems for 2-implants overdentures. Sixteen specimens, each simulating an edentulous ridge with implants and an overdenture were divided into two groups, according to the attachment system: Group I (Nobel Biocare ball-socket attachments) and Group II (Locator attachments). Retention forces were measured before and after 400 000 simulated masticatory loads in a customised device. Data were compared by two-way anova followed by Bonferroni test (alpha = 0 center dot 05). Group I presented significantly lower retention forces (Newtons) than Group II at baseline (10 center dot 6 +/- 3 center dot 6 and 66 center dot 4 +/- 16 center dot 0, respectively). However, differences were not significant after 400 000 loads (7 center dot 9 +/- 4 center dot 3 and 21 center dot 6 +/- 17 center dot 0). The number of cycles did not influence the measurements in Group I, whereas a non-linear descending curve was found for Group II. It was concluded that simulated mastication resulted in minor changes for the ball attachment tested. Nevertheless, it reduced the retention of Locator attachments to 40% of the baseline values, what suggests that mastication is a major factor associated with maintenance needs for this system.
Resumo:
Some authors argue that both substance dependence and eating disorders should be considered as dependent behaviours. Similarities and differences between these disorders, however, remain unclear. This study compares processes of emotion regulation in adolescents and young adults (15 to 25 years old) with substance dependence (SD) or eating disorders (ED). One hundred and thirteen SD, 50 ED and 86 non-clinical subjects (NC), recruited in four French and Swiss locations, completed a self-report questionnaire of emotion regulation strategies. This questionnaire addresses the subjects' relationships, concerning past and present family, and refers to Main's (1990) concept of primary strategy (balanced activation and deactivation of attachment behaviours), and of secondary strategies (hyperactivation or excessive deactivation of the attachment system). Participants were also questioned in structured interviews, about life events and DSM-IV classification criteria. SD reported more adverse events than ED and NC. SD and ED reported using fewer primary strategies than NC, and SD had secondary strategies that were different from those of ED. Patients with eating disorders reported more hyperactivation, and SD reported more deactivation of the attachment system. It is hypothesized that while subjects with SD and ED have in common poorly regulated strategies, they differ in the way they process emotion or relationship-related information.
Resumo:
Developing a strong relationship is essential for optimal child development and it is possible for fathers to fully participate in developing this close bond. Men often develop this relationship through interactive play which usually occurs later in their child's development. As a result, fathers often feel dissatisfied with their ability to form a close attachment in the early post-partum period, which in turn may increase their stress level. However, men can be prepared for the transition to fatherhood if they develop the knowledge and skill necessary to create positive relationships with their infants. Infant massage appears to be a viable option for teaching fathers care-giving sensitivity. To build on the notion of teaching fathers attachment system behaviour in early infancy, a quasi-experimental, mixed methods study was employed. Twenty-four infant-father dyads were recruited for the study. The fathers were asked to fill out the Parent Stress Index and a facial cues rating scale at two times, one month apart. The experimental group also participated in an infant massage intervention taught by a Certified Infant Massage Instructor of the International Association of Infant Massage. A repeated measures MANOVA revealed infant massage decreased paternal stress. Qualitatively, the fathers provided rich descriptions of their experience in the baby massage class which provided useful insight into the efficacy of the intervention. Overall, the fathers enjoyed the experience but did not necessarily see the direct benefit of the intervention on their relationship. Recommendations for pre and postnatal education for fathers are made.
Resumo:
This study aimed to compare the influence of single-standing or connected implants on stress distribution in bone of mandibular overdentures by means of two-dimensional finite element analysis. Two finite element models were designed using software (ANSYS) for 2 situations: bar-clip (BC) group-model of an edentulous mandible supporting an overdenture over 2 connected implants with BC system, and o'ring (OR) group-model of an edentulous mandible supporting an overdenture over 2 single-standing implants with OR abutments. Axial loads (100 N) were applied on either central (L1) or lateral (L2) regions of the models. Stress distribution was concentrated mostly in the cortical bone surrounding the implants. When comparing the groups, BC (L1, 52.0 MPa and L2, 74.2 MPa) showed lower first principal stress values on supporting tissue than OR (L1, 78.4 MPa and L2, 76.7 MPa). Connected implants with BC attachment were more favorable on stress distribution over peri-implant-supporting tissue for both loading conditions.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)