967 resultados para activity measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The amount of crystalline fraction present in monohydrate glucose crystal-solution mixture up to 110% crystal in relation to solution (crystal:solution=110:100) was determined by water activity measurement. It was found that the water activity had a strong linear correlation (R-2=0.994) with the amount of glucose present above saturation. Difference in the water activities of the crystal-solution mixture (a(w1)) and the supersaturated solution (a(w2)) by re-dissolving the crystalline fraction allowed calculation of the amount of crystalline phase present (DeltaG) in the mixture by an equation DeltaG=846.97(a(w1)-a(w2)). Other methods such as Raoult's, Norrish and Money-Born equations were also tested for the prediction of water activity of supersaturated glucose solution. (C) 2003 Swiss Society of Food Science and Technology. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the importance of physical activity is recognised in health promotion, the task of measuring it becomes a central research and practice challenge. Measurement of physical activity is important to policy makers interested in population surveillance, as well as to practitioners interested in programme evaluation and research. This review outlines 'best practice' in physical activity measurement, and provides an inventory of established physical activity and related measures for use in health promotion programme evaluation, research and surveillance at the national and local level. [PUBLICATION ABSTRACT]

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To evaluate the validity of a uniaxial accelerometer (MTI Actigraph) for measuring physical activity in people with acquired brain injury (ABI) using portable indirect calorimetry (Cosmed K4b(2)) as a criterion measure. Methods: Fourteen people with ABI and related gait pattern impairment (age 32 +/- 8 yr) wore an MTI Actigraph that measured activity (counts(.)min-(1)) and a Cosmed K4b(2) that measured oxygen consumption (mL(.)kg(-1.)min(-1)) during four activities: quiet sitting (QS) and comfortable paced (CP), brisk paced (BP), and fast paced (FP) walking. MET levels were predicted from Actigraph counts using a published equation and compared with Cosmed measures. Predicted METs for each of the 56 activity bouts (14 participants X 4 bouts) were classified (light, moderate, vigorous, or very vigorous intensity) and compared with Cosmed-based classifications. Results: Repeated-measures ANOVA indicated that walking condition intensities were significantly different (P < 0.05) and the Actigraph detected the differences. Overall correlation between measured and predicted METs was positive, moderate, and significant (r = 0.74). Mean predicted METs were not significantly different from measured for CP and BP, but for FP walking, predicted METs were significantly less than measured (P < 0.05). The Actigraph correctly classified intensity for 76.8% of all activity bouts and 91.5% of light- and moderate-intensity bouts. Conclusions: Actigraph counts provide a valid index of activity across the intensities investigated in this study. For light to moderate activity, Actigraph-based estimates of METs are acceptable for group-level analysis and are a valid means of classifying activity intensity. The Actigraph significantly underestimated higher intensity activity, although, in practice, this limitation will have minimal impact on activity measurement of most community-dwelling people with ABI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The effective evaluation of physical activity interventions for older adults requires measurement instruments with acceptable psychometric properties that are sufficiently sensitive to detect changes in this population. Aim: To assess the measurement properties (reliability and validity) of the Community Healthy Activities Model Program for Seniors (CHAMPS) questionnaire in a sample of older Australians. Methods: CHAMPS data were collected from 167 older adults (mean age 79.1 S.D. 6.3 years) and validated with tests of physical ability and the SF-12 measures of physical and mental health. Responses from a sub-sample of 43 older adults were used to assess 1-week test-retest reliability. Results: Approximately 25% of participants needed assistance to complete the CHAMPS questionnaire. There were low but significant correlations between the CHAMPS scores and the physical performance measures (rho=0.14-0.32) and the physical health scale of the SF-12 (rho=0.12-0.24). Reliability coefficients were highest for moderate-intensity (ICC=0.81-0.88) and lowest for vigorous-intensity physical activity (ICC=0.34-0.45). Agreement between test-retest estimates of sufficient physical activity for health benefits (>= 150 min and >= 5 sessions per week) was high (percent agreement = 88% and Cohen's kappa = 0.68). Conclusion: These findings suggest that the CHAMPS questionnaire has acceptable measurement properties, and is therefore suitable for use among older Australian adults, as long as adequate assistance is provided during administration. (c) 2006 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Appropriate measures of physical activity are essential for determining the population prevalence of physical activity, for tracking trends over time, and for guiding intervention efforts. Physical activity measurement is characterised by the synthesis of information on the type, frequency, intensity, and duration of activity over a specified period. To date, emphasis in physical activity assessment has been on the measurement of leisure time physical activities. However, some domestic and transport related activities entail energy expenditures equivalent to moderate intensity of 3.0–6.0 METS1 considered to be of sufficient intensity to achieve a health benefit are yet to be included in routine population level physical activity surveillance. This leads to population estimates based only on measures of leisure time physical activities.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Poly(methyl methacrylate) (PMMA) based polymer optical fiber Bragg gratings have been used for measuring water activity of aviation fuel. Jet A-1 samples with water content ranging from 100% ERH (wet fuel) to 10 ppm (dried fuel), have been conditioned and calibrated for measurement. The PMMA based optical fiber grating exhibits consistent response and a good sensitivity of 59±3pm/ppm (water content in mass). This water activity measurement allows PMMA based optical fiber gratings to detect very tiny amounts of water in fuels that have a low water saturation point, potentially giving early warning of unsafe operation of a fuel system. © 2014 SPIE.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background Physical activity in children with intellectual disabilities is a neglected area of study, which is most apparent in relation to physical activity measurement research. Although objective measures, specifically accelerometers, are widely used in research involving children with intellectual disabilities, existing research is based on measurement methods and data interpretation techniques generalised from typically developing children. However, due to physiological and biomechanical differences between these populations, questions have been raised in the existing literature on the validity of generalising data interpretation techniques from typically developing children to children with intellectual disabilities. Therefore, there is a need to conduct population-specific measurement research for children with intellectual disabilities and develop valid methods to interpret accelerometer data, which will increase our understanding of physical activity in this population. Methods Study 1: A systematic review was initially conducted to increase the knowledge base on how accelerometers were used within existing physical activity research involving children with intellectual disabilities and to identify important areas for future research. A systematic search strategy was used to identify relevant articles which used accelerometry-based monitors to quantify activity levels in ambulatory children with intellectual disabilities. Based on best practice guidelines, a novel form was developed to extract data based on 17 research components of accelerometer use. Accelerometer use in relation to best practice guidelines was calculated using percentage scores on a study-by-study and component-by-component basis. Study 2: To investigate the effect of data interpretation methods on the estimation of physical activity intensity in children with intellectual disabilities, a secondary data analysis was conducted. Nine existing sets of child-specific ActiGraph intensity cut points were applied to accelerometer data collected from 10 children with intellectual disabilities during an activity session. Four one-way repeated measures ANOVAs were used to examine differences in estimated time spent in sedentary, moderate, vigorous, and moderate to vigorous intensity activity. Post-hoc pairwise comparisons with Bonferroni adjustments were additionally used to identify where significant differences occurred. Study 3: The feasibility on a laboratory-based calibration protocol developed for typically developing children was investigated in children with intellectual disabilities. Specifically, the feasibility of activities, measurements, and recruitment was investigated. Five children with intellectual disabilities and five typically developing children participated in 14 treadmill-based and free-living activities. In addition, resting energy expenditure was measured and a treadmill-based graded exercise test was used to assess cardiorespiratory fitness. Breath-by-breath respiratory gas exchange and accelerometry were continually measured during all activities. Feasibility was assessed using observations, activity completion rates, and respiratory data. Study 4: Thirty-six children with intellectual disabilities participated in a semi-structured school-based physical activity session to calibrate accelerometry for the estimation of physical activity intensity. Participants wore a hip-mounted ActiGraph wGT3X+ accelerometer, with direct observation (SOFIT) used as the criterion measure. Receiver operating characteristic curve analyses were conducted to determine the optimal accelerometer cut points for sedentary, moderate, and vigorous intensity physical activity. Study 5: To cross-validate the calibrated cut points and compare classification accuracy with existing cut points developed in typically developing children, a sub-sample of 14 children with intellectual disabilities who participated in the school-based sessions, as described in Study 4, were included in this study. To examine the validity, classification agreement was investigated between the criterion measure of SOFIT and each set of cut points using sensitivity, specificity, total agreement, and Cohen’s kappa scores. Results Study 1: Ten full text articles were included in this review. The percentage of review criteria met ranged from 12%−47%. Various methods of accelerometer use were reported, with most use decisions not based on population-specific research. A lack of measurement research, specifically the calibration/validation of accelerometers for children with intellectual disabilities, is limiting the ability of researchers to make appropriate and valid accelerometer use decisions. Study 2: The choice of cut points had significant and clinically meaningful effects on the estimation of physical activity intensity and sedentary behaviour. For the 71-minute session, estimations for time spent in each intensity between cut points ranged from: sedentary = 9.50 (± 4.97) to 31.90 (± 6.77) minutes; moderate = 8.10 (± 4.07) to 40.40 (± 5.74) minutes; vigorous = 0.00 (± .00) to 17.40 (± 6.54) minutes; and moderate to vigorous = 8.80 (± 4.64) to 46.50 (± 6.02) minutes. Study 3: All typically developing participants and one participant with intellectual disabilities completed the protocol. No participant met the maximal criteria for the graded exercise test or attained a steady state during the resting measurements. Limitations were identified with the usability of respiratory gas exchange equipment and the validity of measurements. The school-based recruitment strategy was not effective, with a participation rate of 6%. Therefore, a laboratory-based calibration protocol was not feasible for children with intellectual disabilities. Study 4: The optimal vertical axis cut points (cpm) were ≤ 507 (sedentary), 1008−2300 (moderate), and ≥ 2301 (vigorous). Sensitivity scores ranged from 81−88%, specificity 81−85%, and AUC .87−.94. The optimal vector magnitude cut points (cpm) were ≤ 1863 (sedentary), ≥ 2610 (moderate) and ≥ 4215 (vigorous). Sensitivity scores ranged from 80−86%, specificity 77−82%, and AUC .86−.92. Therefore, the vertical axis cut points provide a higher level of accuracy in comparison to the vector magnitude cut points. Study 5: Substantial to excellent classification agreement was found for the calibrated cut points. The calibrated sedentary cut point (ĸ =.66) provided comparable classification agreement with existing cut points (ĸ =.55−.67). However, the existing moderate and vigorous cut points demonstrated low sensitivity (0.33−33.33% and 1.33−53.00%, respectively) and disproportionately high specificity (75.44−.98.12% and 94.61−100.00%, respectively), indicating that cut points developed in typically developing children are too high to accurately classify physical activity intensity in children with intellectual disabilities. Conclusions The studies reported in this thesis are the first to calibrate and validate accelerometry for the estimation of physical activity intensity in children with intellectual disabilities. In comparison with typically developing children, children with intellectual disabilities require lower cut points for the classification of moderate and vigorous intensity activity. Therefore, generalising existing cut points to children with intellectual disabilities will underestimate physical activity and introduce systematic measurement error, which could be a contributing factor to the low levels of physical activity reported for children with intellectual disabilities in previous research.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim: Biokinetics and dosimetry of 111In-DOTA-NOC-ATE (NOCATE) and 111In-DTPA-octreotide (Octreoscan?, OCTREO) were comparatively studied in the same patients. Patients and Methods: Seventeen patients (10 males, 7 females), mean age 60 years referred for an Octreoscan? because of carcinoid (N=9), unspecified neurodendocrine tumors (N=6), thymoma (N=1) or medullary thyroid carcinoma (N=1) accepted a second study with NOCATE. Four patients had no detectable tumor at the time of scanning. Whole-body (WB) anterior-posterior scans were recorded 0.5 (100% reference scan), 4, 24 and 48 hrs (N=17) and 120 hrs (N=6) after injection. OCTREO (178±15 MBq) preceded NOCATE (108±14 MBq) imaging with 16±5 days in 16 patients while 1 patient had first NOCATE followed 14 days later by OCTREO. Blood samples were taken 5, 15, 30, 60, 240 and 1440 min after injection. Background corrected geometric mean counts of WB, lung, kidney, liver, spleen and blood counts expressed in % of the initial composite WB and blood counts, respectively were fitted to bi- or single exponential curves and dosimetry was performed for male and female patients using MIRDOSE3.1 and OLINDA/EXM. Results: Initially, WB, lung and kidney activity was similar but retention was significantly higher for NOCATE compared with OCTREO. Liver and spleen uptake of NOCATE was higher from beginning (p<0.001) and remained so over time. Activity in rest of body showed similar α and β half-lives, but the β half-life fraction of NOCATE was much higher than OCTREO (49% vs. 19%, respectively). Blood T1/2β was longer for NOCATE compared with OCTREO (19 vs. 6h). Residence times were similar in male and female patients while they were in both genders higher for NOCATE than OCTREO. Consequently, effective dose (ED) for NOCATE (ED 114 and 134 μSv/MBq for man and women, respectively) exceeded that of OCTREO (ED = 61 and 71 μSv/MBq), the latter results being close to the ICRP-published radiation dose of OCTREO (ED = 54 and 71 µSv/MBq, respectively). Differential activity measurement in blood cells and plasma showed that only a minor fraction of NOCATE and OCTREO (<5 % in the mean) was bound to globular blood components. Conclusions: NOCATE showed higher retention in normal organs and delivered roughly twice the radiation dose of OCTREO. The ED of OCTREO in these patients was similar to ICRP80 report when adopting a bladder voiding interval of 2 hours.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: The biokinetics and dosimetry of (111)In-DOTA-NOC-ATE (NOCATE), a high-affinity ligand of SSTR-2 and SSTR-5, and (111)In-DTPA-octreotide (Octreoscan?, OCTREO) were compared in the same patients. METHODS: Seventeen patients (10 men, 7 women; mean age 60 years), referred for an OCTREO scan for imaging of a neuroendocrine tumour (15), thymoma (1) or medullary thyroid carcinoma (1), agreed to undergo a second study with NOCATE. Whole-body anterior-posterior scans were recorded 0.5 (100 % reference scan), 4, 24 and 48 h (17 patients) and 120 h (5 patients) after injection. In 16 patients the OCTREO scan (178 ± 15 MBq) was performed 16 ± 5 days before the NOCATE scan (108 ± 14 MBq) with identical timing; 1 patient had the NOCATE scan before the OCTREO scan. Blood samples were obtained from 14 patients 5 min to 48 h after injection. Activities expressed as percent of the initial (reference) activity in the whole body, lung, kidney, liver, spleen and blood were fitted to biexponential or single exponential functions. Dosimetry was performed using OLINDA/EXM. RESULTS: Initial whole-body, lung and kidney activities were similar, but retention of NOCATE was higher than that of OCTREO. Liver and spleen uptakes of NOCATE were higher from the start (p < 0.001) and remained so over time. Whole-body activity showed similar α and β half-lives, but the β fraction of NOCATE was double that of OCTREO. Blood T (1/2)β for NOCATE was longer (19 vs. 6 h). As a result, the effective dose of NOCATE (105 μSv/MBq) exceeded that of OCTREO (52 μSv/MBq), and the latter result was similar to the ICRP 106 value of 54 μSv/MBq. Differential activity measurement in blood cells and plasma showed an average of <5 % of NOCATE and OCTREO attached to globular blood components. CONCLUSION: NOCATE showed a slower clearance from normal tissues and its effective dose was roughly double that of OCTREO.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this chapter is to give insights into metacaspase of Leishmania protozoan parasites as arginine-specific cysteine peptidase. The physiological role of metacaspase in Leishmania is still a matter of debate, whereas its peptidase enzymatic activity has been well characterized. Among the different possible expression systems, metacaspase-deficient yeast cells (Δyca1) have been instrumental in studying the activity of Leishmania major metacaspase (LmjMCA). Here, we describe techniques for purification of LmjMCA and its activity measurement, providing a platform for further identification of LmjMCA substrates.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND. Human primary fetal bone cells (hFBC) are being characterized for use in bone tissue regeneration. Unlike human mesenchymal stem cells (hMSC), hFBC are partially differentiated with high expansion and regeneration potential. To date, proliferative and osteoblastic differentiation capacities of fetal bone cells remain poorly examined. The goal of this study was to define an environmental culture conditions for optimal proliferation and production of extracellular bone matrix leading to efficient bone repair. METHODS. Human primary FBC derived from our dedicated, consistent banks of bone cells comprising several fetal donors. For proliferation study, monolayer cultures of both cell types were expanded in DMEM or α- MEM media. Osteoblastic differentiation potentials of both hFBC and hMSC were evaluated through RT-PCR. Regulation of osteogenic differentiation by protein ligands Wnt3a and Wnt5a was studied by ALP enzymatic activity measurement. RESULTS. Evaluation of the proliferation rate demonstrated that hFBC proliferated more rapidly in α-MEM medium. Regarding growth factors that could stimulate cell proliferation rate, we observed that PDGF, FGF2 and Wnt3a had positive effects on proliferation of hFBC. Gene expression analysis demonstrated a higher expression of runx2 in hFBC cultured in basal conditions, which was was similar than that was observed in hMSC in osteoinductive culture conditions. Expression of sox9 was very low in hBFC and hMSC, compared to expression observed in fetal cartilage cells. Looking at osteogenic differentiation capacity, ALP activity was positively regulated byWnt5awhen hFBCwere cultured inα-MEM, but not in DMEM. Conversely, Wnt3a was shown to block the effect of osteogenic inductors on differentiation of both cell types. CONCLUSION. Data presented in this study indicate that the proliferation and differentiation of fetal and mesenchymal stem cells is optimal in α- MEM. Evidence for a pre-differentiated state of hBFC was given by extracellular matrix spontaneous mineralization as well as by higher ALP activity levels observed for these cells in baseline culture conditions, in comparison with hMSC. As we showed that, in vitro, hFBC express a higher capacity to differentiate in osteoblasts, they represent an attractive and promising prospect for fundamental research, and specifically for a new generation of skeletal tissue engineering.