991 resultados para access site
Resumo:
The safety of percutaneous transapical mitral paravalvular leak (PVL) closure could potentially be enhanced by device closure of the ventricular access site. Percutaneous transapical PVL closure was performed. The 9F delivery sheath was pulled back, and a 6-mm Amplatzer muscular ventricular septal defect occluder was deployed at the apical puncture site. Immediate hemostasis was achieved. Total hospitalization was 9 days. New York Heart Association functional class was improved, hemoglobin and haptoglobin rose, while lactate dehydrogenase fell. Follow-up fluoroscopy and transthoracic echocardiography revealed a good functional result. Closure of the apical access site by means of an Amplatzer muscular ventricular septal defect occluder is feasible.
Resumo:
© 2015 Wiley Periodicals, Inc.
Resumo:
© 2015 Wiley Periodicals, Inc.
Resumo:
The majority of transcatheter aortic valve implantations, structural heart procedures and the newly developed transcatheter mitral valve repair and replacement are traditionally performed either through a transfemoral or a transapical access site, depending on the presence of severe peripheral vascular disease or anatomic limitations. The transapical approach, which carries specific advantages related to its antegrade nature and the short distance between the introduction site and the cardiac target, is traditionally performed through a left anterolateral mini-thoracotomy and requires rib retractors, soft tissue retractors and reinforced apical sutures to secure, at first, the left ventricular apex for the introduction of the stent-valve delivery systems and then to seal the access site at the end of the procedure. However, despite the advent of low-profile apical sheaths and newly designed delivery systems, the apical approach represents a challenge for the surgeon, as it has the risk of apical tear, life-threatening apical bleeding, myocardial damage, coronary damage and infections. Last but not least, the use of large-calibre stent-valve delivery systems and devices through standard mini-thoracotomies compromises any attempt to perform transapical transcatheter structural heart procedures entirely percutaneously, as happens with the transfemoral access site, or via a thoracoscopic or a miniaturised video-assisted percutaneous technique. During the past few years, prototypes of apical access and closure devices for transapical heart valve procedures have been developed and tested to make this standardised successful procedure easier. Some of them represent an important step towards the development of truly percutaneous transcatheter transapical heart valve procedures in the clinical setting.
Resumo:
Background Transcatheter aortic valve implantation (TAVI) is a treatment option for high-risk patients with severe aortic stenosis. Previous reports focused on a single device or access site, whereas little is known of the combined use of different devices and access sites as selected by the heart team. The purpose of this study is to investigate clinical outcomes of TAVI using different devices and access sites. Methods A consecutive cohort of 200 patients underwent TAVI with the Medtronic CoreValve Revalving system (Medtronic Core Valve LLC, Irvine, CA; n = 130) or the Edwards SAPIEN valve (Edwards Lifesciences LLC, Irvine, CA; n = 70) implanted by either the transfemoral or transapical access route. Results Device success and procedure success were 99% and 95%, respectively, without differences between devices and access site. All-cause mortality was 7.5% at 30 days, with no differences between valve types or access sites. Using multivariable analysis, low body mass index (<20 kg/m2) (odds ratio [OR] 6.6, 95% CI 1.5-29.5) and previous stroke (OR 4.4, 95% CI 1.2-16.8) were independent risk factors for short-term mortality. The VARC-defined combined safety end point occurred in 18% of patients and was driven by major access site complications (8.0%), life-threatening bleeding (8.5%) or severe renal failure (4.5%). Transapical access emerged as independent predictor of adverse outcome for the Valve Academic Research Consortium–combined safety end point (OR 3.3, 95% CI 1.5-7.1). Conclusion A heart team–based selection of devices and access site among patients undergoing TAVI resulted in high device and procedural success. Low body mass index and history of previous stroke were independent predictors of mortality. Transapical access emerged as a risk factor for the Valve Academic Research Consortium–combined safety end point.
Resumo:
OBJECTIVES Percutaneous closure of the transapical (TA) access site for large-calibre devices is an unsolved issue. We report the first experimental data on the TA PLUG device for true-percutaneous closure following large apical access for transcatheter aortic valve implantation. METHODS The TA PLUG, a self-sealing full-core closure device, was implanted in an acute animal study in six pigs (60.2 ± 0.7 kg). All the pigs received 100 IU/kg of heparin. The targeted activated clotting time was left to normalize spontaneously. After accessing the left ventricular apex with a 39 French introducer, the closure plug device was delivered with a 33 French over-the-wire system under fluoroscopic guidance into the apex. Time to full haemostasis as well as rate of bleeding was recorded. Self-anchoring properties were assessed by haemodynamic push stress under adrenalin challenge. An additional feasibility study was conducted in four pigs (58.4 ± 1.1 kg) with full surgical exposure of the apex, and assessed device anchoring by pull-force measurements with 0.5 Newton (N) increments. All the animals were electively sacrified. Post-mortem analysis of the heart was performed and the renal embolic index assessed. RESULTS Of six apical closure devices, five were correctly inserted and fully deployed at the first attempt. One became blocked in the delivery system and was placed successfully at the second attempt. In all the animals, complete haemostasis was immediate and no leak was recorded during the 5-h observation period. Neither leak nor any device dislodgement was observed under haemodynamic push stress with repeated left ventricular peak pressure of up to 220 mmHg. In the feasibility study assessing pull-stressing, device migration occurred at a force of 3.3 ± 0.5 N corresponding to 247.5 mmHg. Post-mortem analyses confirmed full expansion of all devices at the intended target. No macroscopic damage was identified at the surrounding myocardium. The renal embolic index was zero. CONCLUSIONS True-percutaneous left ventricular apex closure following large access is feasible with the self-sealing TA PLUG. The device allows for immediate haemostasis and a reliable anchoring in the acute animal setting. This is the first report of a true-percutaneous closure for large-calibre transcatheter aortic valve implantation access.
Resumo:
This thesis provides a query model suitable for context sensitive access to a wide range of distributed linked datasets which are available to scientists using the Internet. The model is designed based on scientific research standards which require scientists to provide replicable methods in their publications. Although there are query models available that provide limited replicability, they do not contextualise the process whereby different scientists select dataset locations based on their trust and physical location. In different contexts, scientists need to perform different data cleaning actions, independent of the overall query, and the model was designed to accommodate this function. The query model was implemented as a prototype web application and its features were verified through its use as the engine behind a major scientific data access site, Bio2RDF.org. The prototype showed that it was possible to have context sensitive behaviour for each of the three mirrors of Bio2RDF.org using a single set of configuration settings. The prototype provided executable query provenance that could be attached to scientific publications to fulfil replicability requirements. The model was designed to make it simple to independently interpret and execute the query provenance documents using context specific profiles, without modifying the original provenance documents. Experiments using the prototype as the data access tool in workflow management systems confirmed that the design of the model made it possible to replicate results in different contexts with minimal additions, and no deletions, to query provenance documents.
Resumo:
Background: Arteriovenous fistula (AVF) failure to mature (FTM) rates contribute to excessive dependence on central venous catheters for haemodialysis. Choosing the most appropriate vascular access site for an individual patient is guided largely by their age, co-morbidities and clinical examination. We investigated the clinical predictors of AVF FTM in a European cohort of patients and applied an existing clinical risk prediction model for AVF FTM to this population.
Methods: A prospective cohort study was designed that included all patients undergoing AVF creation between January 2009 and December 2014 in a single centre (Belfast City Hospital) who had a functional AVF outcome observed by March 2015.
Results: A total of 525 patients had a functional AVF outcome recorded and were included in the FTM analysis. In this cohort, 309 (59%) patients achieved functional AVF patency and 216 (41%) patients had FTM. Female gender [P < 0.001, odds ratio (OR) 2.03 (CI 1.37–3.02)] and lower-arm AVF [P < 0.001, OR 4.07 (CI 2.77–5.92)] were associated with AVF FTM. The Lok model did not predict FTM outcomes based on the associated risk stratification in our population.
Conclusions: In this European study, female gender was associated with twice the risk of AVF FTM and a lower-arm AVF with four times the risk of FTM. The FTM risk prediction model was not found to be discriminative in this population. Clinical risk factors for AVF FTM vary between populations;we would recommend that units investigate their own clinical predictors of FTM to maximize AVF functional patency and ultimately survival in dialysis patients. Clinical predictors of AVF FTM may not be sufficient on their own to improve vascular access functional patency rates.
Resumo:
Objetivo: Comparar las complicaciones del uso de Angioseal® versus compresión manual en los pacientes llevados a cateterismo cardíaco en el Servicio de Hemodinamia de la Fundación Santa Fe de Bogotá, del 1º de enero de 2005 al 31 de diciembre de 2010, mediante punción arterial femoral percutánea. Metodología: Se realizó un Estudio Observacional, Analítico, de tipo Cohorte Retrospectiva. Partiendo de dos grupos de personas con indicación de cateterismo cardíaco por cualquier causa, uno expuesto al procedimiento con Angioseal® y el otro con compresión manual. Resultados: Con el uso de Angioseal® versus compresión manual la aparición de complicaciones fue 7,3% vs 4,1%, estas diferencias no fueron significativas (OR 1,81 IC95 0,96-3,40; RR 1,75 IC95 0,96-3,18) . La enfermedad coronaria (OR 2,27 IC95 1,07-4,79; RR 2,18 IC95 1,06-4,46) y a la colocación de stent (OR 3,49 IC95 1,82-6,69; RR 3,25 IC95 1,75-6,02 si se relacionaron significativamente con la aparición de complicaciones menores. Conclusión: No encontramos soporte para aprobar o desaprobar el uso de Angioseal® o compresión manual como manejo de la hemostasia, con respecto a las complicaciones. Sin embargo, se encontró que la colocación de stents está fuertemente relacionada con el desarrollo de complicaciones menores, lo cual hace que estos pacientes deban ser objeto de monitorización estrecha.
Resumo:
Este estudo apresenta resultados preliminares obtidos com um novo filtro permanente de veia cava, baseado no desenho de Greenfield, com três hastes prolongadas de um total de seis, para dar estabilidade central ao filtro na luz da veia cava. Neste artigo, relatamos sua avaliação clínica preliminar quanto à aplicabilidade, eficácia e segurança. de agosto de 2004 a dezembro de 2006, 15 filtros foram implantados em nove homens e seis mulheres, com idades variando de 38 a 79 anos (média de 57,8 anos). O acesso foi feito sempre por via transjugular. As indicações foram: trombose venosa proximal, com contra-indicação de anticoagulação em 12 pacientes; complicações hemorrágicas com anticoagulação em dois pacientes; e embolia pulmonar, apesar de anticoagulação adequada, em um paciente. Os filtros foram avaliados quanto à liberação, inclinação, mau posicionamento e perfuração de cava. No seguimento, avaliou-se trombose no local de acesso, tromboembolismo venoso recorrente, migração do filtro e trombose de cava pelo ultra-som. Nenhum paciente recebeu anticoagulantes no seguimento. O filtro foi liberado com sucesso em todos os casos sem mau posicionamento, inclinação, perfuração ou trombose de acesso. Os pacientes foram seguidos entre 3 e 23 meses (média de 11 meses). Nenhum paciente teve recorrência de tromboembolismo venoso. Não houve casos de trombose de veia cava ou migração do filtro. Óbito ocorreu em sete casos, todos relacionados com a moléstia de base. Os resultados preliminares indicam potencial eficácia e segurança do uso do novo filtro no período estudado.
Resumo:
There is an interest to keep the arterial access site for percutaneous coronary interventions (PCI) small. Using sheaths for introduction of arterial catheters is standard. The effective outer diameter of the usual introducer sheaths is about 1.5 French (F) larger than the labeled size. Omitting the sheath affords a smaller access without loss of working lumen.
Resumo:
Introduction Reduced left ventricular function in patients with severe symptomatic valvular aortic stenosis is associated with impaired clinical outcome in patients undergoing surgical aortic valve replacement (SAVR). Transcatheter Aortic Valve Implantation (TAVI) has been shown non-inferior to SAVR in high-risk patients with respect to mortality and may result in faster left ventricular recovery. Methods We investigated clinical outcomes of high-risk patients with severe aortic stenosis undergoing medical treatment (n = 71) or TAVI (n = 256) stratified by left ventricular ejection fraction (LVEF) in a prospective single center registry. Results Twenty-five patients (35%) among the medical cohort were found to have an LVEF≤30% (mean 26.7±4.1%) and 37 patients (14%) among the TAVI patients (mean 25.2±4.4%). Estimated peri-interventional risk as assessed by logistic EuroSCORE was significantly higher in patients with severely impaired LVEF as compared to patients with LVEF>30% (medical/TAVI 38.5±13.8%/40.6±16.4% versus medical/TAVI 22.5±10.8%/22.1±12.8%, p <0.001). In patients undergoing TAVI, there was no significant difference in the combined endpoint of death, myocardial infarction, major stroke, life-threatening bleeding, major access-site complications, valvular re-intervention, or renal failure at 30 days between the two groups (21.0% versus 27.0%, p = 0.40). After TAVI, patients with LVEF≤30% experienced a rapid improvement in LVEF (from 25±4% to 34±10% at discharge, p = 0.002) associated with improved NYHA functional class at 30 days (decrease ≥1 NYHA class in 95%). During long-term follow-up no difference in survival was observed in patients undergoing TAVI irrespective of baseline LVEF (p = 0.29), whereas there was a significantly higher mortality in medically treated patients with severely reduced LVEF (log rank p = 0.001). Conclusion TAVI in patients with severely reduced left ventricular function may be performed safely and is associated with rapid recovery of systolic left ventricular function and heart failure symptoms.
Resumo:
Transcatheter aortic valve implantation (TAVI) for the treatment of symptomatic severe aortic stenosis has emerged as an effective treatment for high risk patients. In 2002 TAVI was performed for the first time in a human by Alain Cribier, using an antegrade access approach via the femoral vein, crossing the intra-atrial septum after puncture and passing the native aortic valve in the direction of blood flow. This technically demanding approach was subsequently replaced by retrograde transfemoral arterial access. For patients with severe peripheral vascular disease or inadequately sized femoral arteries, the transapical route provides an alternative route with antegrade access to the aortic valve via puncture of the anterolateral wall of the left ventricle. The transsubclavian access approach using most frequently the left subclavian artery and direct transaortic access have been introduced more recently and attest to the versatility of TAVI in terms of access site. This article will focus on the different access site options available to operators, provide a step-by-step guide through the procedure, and a detailed description of the technological evolution of transcatheter heart valve systems.
Resumo:
This report describes the use of transluminal coil embolization to treat pseudoaneurysm of deep femoral artery branch in two patients. The pseudoaneurysms had developed after coronary angiographv in one patient and after hip replacement in the other. Immediate control angiography after embolization procedures demonstrated complete closure of the pseudoaneurysms. During follow-up of 19 and 3 months, respectively, there was no recurrent bleeding. The aim of this case report is to show the advances in endovascular microcatheter technology, and embolic materials, that made percutaneous transluminal embolization of arterial pseudoaneurysms safe and efficient. In addition, it keeps the medical personnel aware of vascular injuries at the access site related to endovascular procedures as well as vascular complications of total hip arthroplasty. It calls their attention to the possibility of endovascular treatment as an alternative to surgery.
Resumo:
OBJECTIVES: To evaluate the efficacy of stent placement after infrainguinal loco-regional thrombolysis and iliac thrombectomy (surgical TT) of acute deep vein thrombosis (DVT) in patients with May-Thurner-Syndrome. MATERIAL AND METHODS: We retrospectively analysed a group of 11 patients (9 women) (mean age 34 years, range 16-64 years) with surgical TT and additional intra-operative stenting due to compression of the common iliac vein. Patients underwent venography to demonstrate outflow patency after surgical TT, and to identify any obstruction at the level of the left-sided common iliac vein ("Beckenvenen-Sporn"). Obstruction at the level of arterial crossing was treated using Wallstents placed via an introducer sheath from the inguinal access site. Stents were fully deployed using balloons adjusted to the size of vein. Patients were treated with oral anticoagulants for 6 months, and followed using duplex ultrasonography. RESULTS: Technical success defined as complete vein patency and normal valve function was documented in all 11 patients. One patient needed early stent extension due to residual stenosis. At 6 months follow-up one patient (9%) had an asymptomatic occlusion of the stented common iliac vein. In all 11/11 (100%) patients the femoral segment was found to be patent, and in 1/11 (9%) there was mild reflux with few clinical symptoms of post-thrombotic syndrome. The calculated cumulative primary patency rate for venous iliac stents was 82%, and assisted patency rate was 91%, which remained unchanged over a mean follow-up of 22 months. CONCLUSION: Combining surgical TT and stenting of common iliac vein obstructions in DVT is safe, effective, and results in a acceptable venous patency.