Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes


Autoria(s): Wenaweser, Peter; Pilgrim, Thomas; Roth, Nadja; Kadner, Alexander; Stortecky, Stefan; Kalesan, Bindu; Meuli, Fabienne; Büllesfeld, Lutz; Khattab, Ahmed A; Huber, Christoph; Eberle, Balthasar; Erdös, Gabor; Meier, Bernhard; Jüni, Peter; Carrel, Thierry; Windecker, Stephan
Data(s)

2011

Resumo

Background Transcatheter aortic valve implantation (TAVI) is a treatment option for high-risk patients with severe aortic stenosis. Previous reports focused on a single device or access site, whereas little is known of the combined use of different devices and access sites as selected by the heart team. The purpose of this study is to investigate clinical outcomes of TAVI using different devices and access sites. Methods A consecutive cohort of 200 patients underwent TAVI with the Medtronic CoreValve Revalving system (Medtronic Core Valve LLC, Irvine, CA; n = 130) or the Edwards SAPIEN valve (Edwards Lifesciences LLC, Irvine, CA; n = 70) implanted by either the transfemoral or transapical access route. Results Device success and procedure success were 99% and 95%, respectively, without differences between devices and access site. All-cause mortality was 7.5% at 30 days, with no differences between valve types or access sites. Using multivariable analysis, low body mass index (<20 kg/m2) (odds ratio [OR] 6.6, 95% CI 1.5-29.5) and previous stroke (OR 4.4, 95% CI 1.2-16.8) were independent risk factors for short-term mortality. The VARC-defined combined safety end point occurred in 18% of patients and was driven by major access site complications (8.0%), life-threatening bleeding (8.5%) or severe renal failure (4.5%). Transapical access emerged as independent predictor of adverse outcome for the Valve Academic Research Consortium–combined safety end point (OR 3.3, 95% CI 1.5-7.1). Conclusion A heart team–based selection of devices and access site among patients undergoing TAVI resulted in high device and procedural success. Low body mass index and history of previous stroke were independent predictors of mortality. Transapical access emerged as a risk factor for the Valve Academic Research Consortium–combined safety end point.

Formato

application/pdf

Identificador

http://boris.unibe.ch/2602/1/Wenaweser%20AmHeartJ%202011.pdf

Wenaweser, Peter; Pilgrim, Thomas; Roth, Nadja; Kadner, Alexander; Stortecky, Stefan; Kalesan, Bindu; Meuli, Fabienne; Büllesfeld, Lutz; Khattab, Ahmed A; Huber, Christoph; Eberle, Balthasar; Erdös, Gabor; Meier, Bernhard; Jüni, Peter; Carrel, Thierry; Windecker, Stephan (2011). Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes. American Heart Journal, 161(6), pp. 1114-1124. St. Louis, Mo.: Elsevier 10.1016/j.ahj.2011.01.025 <http://dx.doi.org/10.1016/j.ahj.2011.01.025>

doi:10.7892/boris.2602

info:doi:10.1016/j.ahj.2011.01.025

info:pmid:21641358

urn:issn:0002-8703

Idioma(s)

eng

Publicador

Elsevier

Relação

http://boris.unibe.ch/2602/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Wenaweser, Peter; Pilgrim, Thomas; Roth, Nadja; Kadner, Alexander; Stortecky, Stefan; Kalesan, Bindu; Meuli, Fabienne; Büllesfeld, Lutz; Khattab, Ahmed A; Huber, Christoph; Eberle, Balthasar; Erdös, Gabor; Meier, Bernhard; Jüni, Peter; Carrel, Thierry; Windecker, Stephan (2011). Clinical outcome and predictors for adverse events after transcatheter aortic valve implantation with the use of different devices and access routes. American Heart Journal, 161(6), pp. 1114-1124. St. Louis, Mo.: Elsevier 10.1016/j.ahj.2011.01.025 <http://dx.doi.org/10.1016/j.ahj.2011.01.025>

Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed