924 resultados para Wall building technology
Resumo:
4th Conference COST ACTION FP1303 – Designing with Bio-based Materials – Challenges and opportiunities. INIA – CSIC, Madrid, 24-25 February 2016. Book of abstracts, T.Troya, J.Galván, D.Jones (Eds.), INIA and IETcc – CSIS, pg. 79-80 (ISBN: 978-91-88349-16-3)
Resumo:
En este trabajo se analizan las publicaciones procedentes de instituciones españolas recogidas en las revistas de la categoría Construction & Building Technology de la base de datos Web of Science para el periodo 1997-2008. El número de revistas incluidas es de 35 y el número de artículos publicados ha sido de 760 (Article o Review). Se ha realizado una evaluación bibliométrica con dos nuevos parámetros: Factor de Impacto Ponderado y Factor de Impacto Relativo; asimismo se incluyen el número de citas y el número de documentos a nivel institucional. Entre los centros con una mayor producción científica destaca, como era de prever, el Instituto de Ciencias de la Construcción Eduardo Torroja (CSIC), mientras que atendiendo al Factor de Impacto Ponderado ocupa el primer lugar la Universidad de Vigo. Por otro lado, sólo dos revistas Cement and Concrete Research y Materiales de Construcción aglutinan el 45.26% de toda la producción científica española, con 172 trabajos cada una de ellas. En cuanto a la colaboración internacional, destacan países como Inglaterra, México, Estados Unidos, Italia, Argentina y Francia
Resumo:
Crossed-arch vaults are a particular type of ribbed vaults. Their main feature is that the ribs that form the vault are intertwined, forming polygons or stars and leaving an empty space in the middle. The firsts appear in Córdoba in the second half of the 10th Century. Afterwards, the type diffused through Spain and North Africa, 11th_13th Centuries. These vaults reappear in Armenia in the 13th Century. In the 14th and 15th Century a few examples are found both in England (Durham, Raby) and Central Europe (Prague, Landshut, Vienna). At about the same time, Leonardo da Vinci produced designs for the Tiburio (Ciborium) of Milan cathedral with a cross-arched structure and proposed tests to assess the strength; he also, made use of the same pattern of vault for Renaissance centralized churches. Eventually, the type can be tracked through the 17th (Guarini) and 18th (Vittone) Centuries, until Spanish post war architecture in the 1940-60s (Moya). Some questions arose, which so far, have not been answered. How was it possible that a particular type of vault had such enormous geographical spread? How was it transmitted from Córdoba to the Caucasus? The matter is one of transfer of knowledge, ideas, and technology; it relates both aesthetics and construction.
Resumo:
Mode of access: Internet.
Resumo:
Cover title.
Resumo:
"December 1979."
Resumo:
The influence of the aspect ratio (building height/street canyon width) and the mean building height of cities on local energy fluxes and temperatures is studied by means of an Urban Canopy Model (UCM) coupled with a one-dimensional second-order turbulence closure model. The UCM presented is similar to the Town Energy Balance (TEB) model in most of its features but differs in a few important aspects. In particular, the street canyon walls are treated separately which leads to a different budget of radiation within the street canyon walls. The UCM has been calibrated using observations of incoming global and diffuse solar radiation, incoming long-wave radiation and air temperature at a site in So Paulo, Brazil. Sensitivity studies with various aspect ratios have been performed to assess their impact on urban temperatures and energy fluxes at the top of the canopy layer. In these simulations, it is assumed that the anthropogenic heat flux and latent heat fluxes are negligible. Results show that the simulated net radiation and sensible heat fluxes at the top of the canopy decrease and the stored heat increases as the aspect ratio increases. The simulated air temperature follows the behavior of the sensible heat flux. (C) 2010 Elsevier Ltd. All rights reserved.
Resumo:
This paper presents the experimental results of 32 axially loaded concrete-filled steel tubular columns (CFT). The load was introduced only on the concrete core by means of two high strength steel cylinders placed at the column ends to evaluate the passive confinement provided by the steel tube. The columns were filled with structural concretes with compressive strengths of 30, 60, 80 and 100 MPa. The outer diameter (D) of the column was 114.3 mm, and the length/diameter (L/D) ratios considered were 3, 5, 7 and 10. The wall thicknesses of the tubes (t) were 3.35 mm and 6.0 mm, resulting in diameter/thickness (D/t) ratios of 34 and 19, respectively. The force vs. axial strain curves obtained from the tests showed, in general, a good post-peak behavior of the CFT columns, even for those columns filled with high strength concrete. Three analytical models of confinement for short concrete-filled columns found in the literature were used to predict the axial capacity of the columns tested. To apply these models to slender columns, a correction factor was introduced to penalize the calculated results, giving good agreement with the experimental values. Additional results of 63 CFT columns tested by other researchers were also compared to the predictions of the modified analytical models and presented satisfactory results. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
The performance assessment as to water consumption in WC cisterns has contributed to the development of flushing system technologies, which allow smaller flushing volumes. The purpose of this work is to assess the performance of the the low water consumption requirement of WC cisterns with dual flushing system (6/3L), when compared to 6L flushing volume WC cisterns in multifamily buildings. The research methodology consisted of a case study in a multifamily residential building with submetering system, by monitoring the total water consumption and the two flushing systems using water meters installed in WC cisterns. By means of a mathematical model, a comparison of the design flowrate in the main branch was carried out considering the two types of WC cisterns. The results indicated that the water consumption in the 6L WC cistern was 20% in relation to the total domestic consumption, whereas the water consumption observed in the dual-flush WC cistern (6/3L) was 16%. The dual flushing system (6/3L) presented about 18% consumption reduction impact as compared to the 6 L system. The design flowrate values in the main branch, obtained by the mathematical model, were 0.35 L/s for systems with 6 L WC cistern and 0.34 L/s with dual-flush WC cistern (6/3 L), that is, a reduction of similar to 3%. Practical application: The knowledge of the performance in field of dual-flush WC cistern contributes to industry to improve this system and to users to aid their choice of technologies aimed at water conservation, and so assisting to the development of sustainable buildings.
Resumo:
There are several ways to attempt to model a building and its heat gains from external sources as well as internal ones in order to evaluate a proper operation, audit retrofit actions, and forecast energy consumption. Different techniques, varying from simple regression to models that are based on physical principles, can be used for simulation. A frequent hypothesis for all these models is that the input variables should be based on realistic data when they are available, otherwise the evaluation of energy consumption might be highly under or over estimated. In this paper, a comparison is made between a simple model based on artificial neural network (ANN) and a model that is based on physical principles (EnergyPlus) as an auditing and predicting tool in order to forecast building energy consumption. The Administration Building of the University of Sao Paulo is used as a case study. The building energy consumption profiles are collected as well as the campus meteorological data. Results show that both models are suitable for energy consumption forecast. Additionally, a parametric analysis is carried out for the considered building on EnergyPlus in order to evaluate the influence of several parameters such as the building profile occupation and weather data on such forecasting. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
In the last 7 years, a method has been developed to analyse building energy performance using computer simulation, in Brazil. The method combines analysis of building design plans and documentation, walk-through visits, electric and thermal measurements and the use of an energy simulation tool (DOE-2.1E code), The method was used to model more than 15 office buildings (more than 200 000 m(2)), located between 12.5degrees and 27.5degrees South latitude. The paper describes the basic methodology, with data for one building and presents additional results for other six cases. (C) 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
In recent years it has been noticed the progressive disappearance of vernacular sustainable building technologies all over the world mainly due to a strong urban rehabilitation process with modern technologies not compatible with ancient knowledge. Simultaneously new dwellings are needed all over the world and in this sense it was decided to study an ecological and cost-controlled building technology of monolithic walls that can combine the use of low carbon footprint materials, such as earth, fibres and lime using an invasive species: giant reed cane (Arundo Donax). This paper explains the development of this building technology through testing diverse prototypes.
Resumo:
Projeto de investigação integrado de International Master in Sustainable Built Environment
Resumo:
Turun yliopiston arkeologian oppiaine tutki Raision Ihalan historiallisella kylätontilla, ns. Mullin eduspellolla, asuinpaikan, josta löydettiin maamme oloissa harvinaisen hyvin säilyneitä rakennusten puuosien jäännöksiä. Löytö on ainutlaatuinen Suomen oloissa ja sillä on kansainvälistäkin merkitystä, koska hyvin säilyneet myöhemmän rautakauden ja varhaisen keskiajan maaseutuasuinpaikat, joista tavataan puujäännöksiä, ovat harvinaisia erityisesti itäisen Itämeren piirissä. Rakennukset on ennallistettu käyttäen tiukkaa paikallisen analogian (’Tight Local Analogy’) metodia, erityisesti suoraa historiallista analogista lähestymistapaa. Tätä tarkoitusta varten muodostettiin aluksi arkeologinen, historiallinen ja etnografinen lähdemalli. Tämä valittiin maantieteellisesti ja ajallisesti relevantista tutkimusaineistosta pohjoisen Itämeren piiristä. Tiedot lounaisen Suomen rakennuksista ja rakennusteknologiasta katsottiin olevan tärkein osa mallia johtuen historiallisesta ja spatiaalisesta jatkuvuudesta. Lähdemalli yhdistettiin sitten Mullin arkeologiseen aineistoon ja analyysin tuloksena saatiin rakennusten ennallistukset. Mullista on voitu ennallistaa ainakin kuusi eri rakennusta neljässä eri rakennuspaikassa. Rakennusteknologia perustui kattoa kannattaviin horisontaalisiin pitkiin seinähirsiin, jotka oli nurkissa yhdistetty joko salvoksella tai varhopatsaalla. Kaikissa rakennuksissa ulkoseinän pituus oli 5 – 7 metriä. Löydettiin lisäksi savi- ja puulattioita sekä kaksi tulisijaa, savikupoliuuni ja avoin liesi. Runsaan palaneen saven perusteella on mahdollista päätellä, että katto oli mitä todennäköisimmin kaksilappeinen vuoliaiskatto, joka oli katettu puulla ja/tai turpeella. Kaikki rakennukset olivat samaa tyyppiä ja ne käsittivät isomman huoneen ja kapean eteisen. Kaikki analysoitu puu oli mäntyä. Ulkoalueelta tavattiin lisäksi tunkioita, ojia, aitoja ja erilaisia varastokuoppia. Rakennukset on ajoitettu 900-luvun lopulta 1200-luvun lopulle (cal AD). Lopuksi tutkittiin rakennuksia yhteisöllisessä ympäristössään, niiden ajallista asemaa sekä asukkaiden erilaisia spatiaalisia kokemuksia ja yhteyksiä. Raision Ihalaa analysoidaan sosiaalisen identiteetin ja sen materiaalisten ilmenemismuotojen kautta. Nämä sosiaaliset identiteetit muodostuvat kommunikaatioverkostoista eri spatiaalisilla ja yhteisöllisillä ta¬soilla. Näitä eri tasoja ovat: 1) kotitalous arjen toimintoineen, perhe ja sukulaisuussuhteet traditioineen; 2) paikallinen identiteetti, rakennus, rakennuspaikka, asuinpaikan ympäristö ja sen käyttö, (maa)talo ja kylä; 3) Raision Ihalan kylä laajemmassa alueellisessa kontekstissaan pohjoisen Itämeren piirissä: kauppiaiden ja käsityöläisten kontaktiverkostot, uskonnollinen identiteetti ja sen muutokset.