972 resultados para Visual examination
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to compare the performance of the DIAGNOdent 2095 with visual examination for occlusal caries detection in permanent and primary molars. The sample comprised 148 permanent human molars and 179 primary human molars. The samples were measured and visually examined three times by two examiners. After measurement, the teeth were histologically prepared and assessed for caries extension. Sensitivity, specificity, accuracy and area under the receiver operating characteristics (ROC) curve were calculated. Intra-class correlation (ICC), unweighted kappa and the Bland and Altman method were used to assess inter- and intra-examiner reproducibility. DIAGNOdent showed higher specificity and lower sensitivity than did visual examination. The ICC values indicated an excellent agreement between the examinations. Kappa values varied from good to excellent for DIAGNOdent but from poor to good for visual examination. In conclusion, the DIAGNOdent may be a useful adjunct to conventional methods for occlusal caries detection.
Resumo:
O objetivo do presente trabalho foi avaliar in vivo a detecção de cárie através do exame visual ICDAS, transiluminação por fibra ótica combinado ao ICDAS e exame radiográfico. Um total de 2.279 superfícies proximais e cicatrículas e fissuras em incisivos superiores, pré-molares e molares permanentes e 272 superfícies em molares decíduos em72 escolares (8 a 18 anos) foram avaliadas por um examinador treinado. Os sete escores para detecção de cárie primária do sistema visual ICDAS foram aplicados. Dois equipamentos de transiluminação por fibra ótica foram avaliados: FOTI Schott (SCH), com ponta de fibra ótica com 0,5mm de diâmetro, e FOTI Microlux (MIC), com diâmetro da ponta 3 mm. Durante o exame combinado FOTI/ICDAS, a fibra ótica era utilizada tanto para iluminar quanto para transiluminar a superfície sob avaliação. O exame radiográfico (RX) consistiu de radiografias interproximais posteriores e periapicais anteriores. Os exames foram realizados em consultório odontológico após escovação supervisionada. No primeiro dia de exame, o exame visual utilizando o ICDAS era realizado e em seguida, o exame combinado ao MIC ou SCH. Logo após era realizado o exame radiográfico. Após uma semana, novamente o ICDAS era realizado, e em seguida o exame combinado com o equipamento de FOTI não utilizado na semana anterior. Os exames foram repetidos em 10 pacientes após intervalo mínimo de uma semana para avaliação da reprodutibilidade intra-examinador, a qual apresentou valores de 0,95 (ICDAS), 0,94 (MIC), 0,95 (SCH) e 0,99 (RX) pelo kappa ponderado. Em cicatrículas e fissuras de permanentes, o RX julgou que um número maior de superfícies apresentava lesão em dentina (53) do que os outros métodos (34 a 36); porém não detectou nenhuma lesão em esmalte, as quais foram identificadas pelo ICDAS (94), SCH (107) e MIC (91). Em proximais permanentes, a transiluminação por fibra ótica identificou maior número de proximais como lesão em esmalte - 150 (SCH) e 139 (MIC) - do que o exame visual (106), enquanto o RX identificou somente 43. Em oclusais de decíduos, os quatro métodos julgaram um número aproximadamente similar de superfícies sem lesão (52 a 59) ou com lesão em dentina (21 a 26), assim como para lesões proximais em dentina (31 a 36). Entretanto um número reduzido de lesões proximais decíduas em esmalte foi julgado pelo exame radiográfico (3) em comparação com os outros métodos (15 a 16). Em decíduos, o ICDAS e o FOTI combinado ao exame visual julgaram maior número de lesões proximais em esmalte que o exame radiográfico, sendo que número similar de lesões em dentina foram classificadas pelos quatro métodos em oclusais e proximais de molares decíduos. Em cicatrículas e fissuras de permanentes, tanto o exame visual ICDAS quanto sua combinação aos dois equipamentos de transiluminação apresentaram maior similaridade de superfícies julgadas como lesão em esmalte ou como lesão em dentina, enquanto o exame radiográfico classificou mais superfícies como lesão em dentina e nenhuma como lesão em esmalte. A adição da transiluminação por fibra ótica ao exame visual aumentou em um terço a detecção das lesões cariosas proximais julgadas em dentina pelo ICDAS isoladamente e aproximadamente quadruplicou o número daquelas assim classificadas pela avaliação radiográfica em permanentes.
Resumo:
This in vitro study evaluated the performance of visual (International Caries Detection and Assessment System [ICDAS]) and radiographic (bitewing [BW]) examinations for occlusal caries detection and their associations with treatment decision (TD). Permanent teeth (n=104) with occlusal surfaces varying from sound to cavitated were selected. Sites were identified from 10x occlusal surface photographs. Standardized bitewing (BW) radiographs were taken. Four dentists with at least five years of experience scored all teeth twice (one-week interval) for ICDAS (0-6), BW (0=sound, 1=caries restricted to enamel, 2=caries in outer third dentin, 3=caries in inner third dentin), and TD (0=no treatment, 1=sealant, 2=microabrasion and sealant, 3=round bur sealant, 4a=resin, 4b=amalgam). Histological validation was performed by observation under a light microscope, with lesions classified on a five-point scale. Intraexaminer and inter-examiner repeatability were assessed using two-way tables and intraclass correlation coefficients (ICCs). Comparisons between percentage correct, specificity, sensitivity, and area under the receiver-operating characteristic (ROC) curve were performed using bootstrap analyses. ICCs for intraexaminer and interexaminer repeatability indicated good repeatability for each examiner, ranging from 0.78 to 0.88, and among examiners, ranging from 0.74 to 0.81. Correlation between ICDAS and TD was 0.85 and between BW and TD was 0.78. Correlation between the methods and histological scores was moderate (0.63 for ICDAS and 0.61 for BW). The area under the ROC curve was significantly greater for ICDAS than for BW (p<0.0001). ICDAS had significantly lower specificity than BW did (p=0.0269, 79% vs 94%); however, sensitivity was much higher for ICDAS than for BW (p<0.0001, 83% vs 44%). Data from this investigation suggested that the visual examination (ICDAS) showed better performance than radiographic examination for occlusal caries detection. The ICDAS was strongly associated with TD. Although the correlation between the ICDAS and BW was lower, it is still valuable in the clinical decision-making process.
Resumo:
A study was designed to investigate the effect of medetomidine sedation on quantitative electroencephalography (q-EEG) in healthy young and adult cats to determine objective guidelines for diagnostic EEG recordings and interpretation. Preliminary visual examination of EEG recordings revealed high-voltage low-frequency background activity. Spindles, k-complexes and vertex sharp transients characteristic of sleep or sedation were superimposed on a low background activity. Neither paroxysmal activity nor EEG burst-suppression were observed. The spectral analysis of q-EEG included four parameters, namely, relative power (%), and mean, median and peak frequency (Hz) of all four frequency bands (delta, theta, alpha and beta). The findings showed a prevalence of slow delta and theta rhythms as opposed to fast alpha and beta rhythms in both young (group A) and adult (group B) cats. A posterior gradient was reported for the theta band and an anterior gradient for the alpha and beta bands in both groups, respectively. The relative power value in group B compared to group A was significantly higher for theta, alpha and beta bands, and lower for the delta band. The mean and median frequency values in group B was significantly higher for delta, theta and beta bands and lower for the alpha band. The study has shown that a medetomidine sedation protocol for feline EEG may offer a method for investigating bio-electrical cortical activity. The use of q-EEG analysis showed a decrease in high frequency bands and increased activity of the low frequency band in healthy cats under medetomidine sedation.
Resumo:
The cores described in this report were taken on AMPHITRITE Expedition in Decenber 1963 - February 1964 by Scripps Institution of Oceanography from, the R/V Argo. A total of 148 cores were recovered and are available at Scripps for sampling and study. The coring sites, all in the tropical central Pacific. The AMPHITRITE cores are here briefly described to identify visually distinct units based on lithology, color, texture, or other characteristic unique to an interval of sediment. For determination of lithology, the slides prepared from samples of the cores were examined microscopically in conjuction with the visual examination.
Resumo:
Natural disasters can have adverse effect on human lives. To raise the awareness of research and better combat future events, it is important to identify recent research trends in the area of post disaster reconstruction (PDR). The authors used a three-round literature review strategy to study journal papers published in the last decade that are related to PDR with specific conditions using the Scopus search engine. A wide range of PDR related papers from a general perspective was examined in the first two rounds while the final round established 88 papers as target publications through visual examination of the abstracts, keywords and as necessary, main texts. These papers were analysed in terms of research origins, active researchers, research organisations, most cited papers, regional concerns, major themes and deliverables, for clues of the past trends and future directions. The need for appropriate PDR research is increasingly recognised. The publication number multiplied 5 times from 2002 to 2012. For PDR research with a construction perspective, the increase is sixfold. Developing countries such as those in Asia attract almost 50% researchers' attention for regional concerns while the US is the single most concentrated (24%) country. Africa is hardly represented. Researchers in developed countries lead in worldwide PDR research. This contrasts to the need for expertise in developing countries. Past works focused on waste management, stakeholder analysis, resourcing, infrastructure issue, resilience and vulnerability, reconstruction approach, sustainable reconstruction and governance issues. Future research should respond to resourcing, integrated development, sustainability and resilience building to cover the gaps. By means of a holistic summary and structured analysis of key patterns, the authors hope to provide a streamlined access to existing research findings and make predictions of future trends. They also hope to encourage a more holistic approach to PDR research and international collaborations.
Resumo:
This is the protocol for a review and there is no abstract. The objectives are as follows: Our objective is to determine if there is sufficient evidence to recommend the use of pH testing (the intervention under scrutiny) for verification of correct placement of nasogastric tubes in adults and children. To this end, we will attempt to answer the following questions: 1. In adults and children, is pH testing an effective and safe method for determining whether nasogastric tubes are correctly positioned in the stomach before feeding (or delivery of any fluid) begins? 2. What evidence is there about the risk of adverse events in the case of incorrect placement? For this review, pH testing is defined as: litmus paper, pH indicator test strips, pH meters. These will be tested against other methods used for detecting placement of nasogastric tubes, including visual examination of aspirate, auscultation with insufflation of air, detection of air bubbles in a bowl of water, X-ray, ultrasonography, endoscopy, enzyme analysis of aspirate, capnography, and other methods that do not rely on measurement of pH.
Resumo:
The primary objective of the present work was to study the electronic and in vitro electrochemical properties of micro-arc oxidized titania films on Cp Ti, fabricated independently in various electrolyte solutions consisting of anions such as phosphate (PO43-), borate (B4O72-), citrate (C6H5O73-) and silicate (SiO32-). Further the role of anions on the structural, morphological and compositional properties of the fabricated films was studied. All the titania films were developed by micro-arc oxidation (MAO) technique for a fixed treatment time of 8 min under constant current mode. The surface morphology, elemental distribution, composition and structural characteristics of the films were assessed by scanning electron microscope (SEM) equipped with energy dispersive spectroscopy (EDS) and X-ray diffraction (XRD) techniques. The thermodynamic and kinetic corrosion properties of the films were studied under simulated body fluid (SBF) conditions (pH 7.4 and 37 degrees C) by conducting chronopotentiometric and potentiodynamic polarization tests. Electrochemical impedance spectroscopy (EIS) coupled with equivalent circuit modelling was carried out to analyse the frequency response and Mott-Schottky analysis was performed to study the semiconducting (electronic) properties of the films. Salt spray fog accelerated corrosion test was conducted for 168h as per ASTM B117 standard to corroborate the corrosion and semiconducting properties of the samples based on the visual examination. The XRD results showed that the transformation from the metastable anatase phase to the thermodynamically stable rutile phase and the crystalline growth of the respective phases were strongly influenced by the addition of anions. The SEM-EDS results demonstrated that the phosphorous (P) content in the films varied from 2.4 at% to 5.0 at% indicating that the amount of P in the films could be modified by adding an appropriate electrolyte additive. The electrochemical corrosion test results showed that the film fabricated in citrate (C6H5O73-) containing electrolyte is thermodynamically and kinetically more stable compared to that of all the others. The results of the Mott-Schottky analysis indicated that all the fabricated films showed an n-type semiconducting behaviour and the film developed in citrate (C6H5O73-) containing electrolyte exhibited the lowest donor concentration and the most negative flat band potential that contributed to its highest corrosion resistance in SBF solution. The results of the salt spray accelerated corrosion tests were in agreement with those obtained from the electrochemical and Mott-Schottky analysis.
Resumo:
The acute toxicity of Linear Alkylbenzene Sulphonate (LAS) detergent to Clarias gariepinus fingerlings was investigated using static bioassays and continous aeration over a period of 96h. The 96h LC sub(50) was determined as 24.00mgL super(-1). During the exposure period, the test fish exhibited several behavioural changes before death such as restlessness, rapid swimming, loss of balance, respiratory distress and haemorrhaging of gill filaments amongst others. Opercula ventilation rate as well as visual examination of dead fish indicates lethal effects of the detergent on the fish. Water quality examination showed increase in pH from 6.55 to the alkaline, death point of 10.55. There was also a remarkabel rise of alkalinity from 20.00mgL super(-1) to 52.50mgL super(-1)
Resumo:
The landscape of late medieval Ireland, like most places in Europe, was characterized by intensified agricultural exploitation, the growth and founding of towns and cities and the construction of large stone edifices, such as castles and monasteries. None of these could have taken place without iron. Axes were needed for clearing woodland, ploughs for turning the soil, saws for wooden buildings and hammers and chisels for the stone ones, all of which could not realistically have been made from any other material. The many battles, waged with ever increasingly sophisticated weaponry, needed a steady supply of iron and steel. During the same period, the European iron industry itself underwent its most fundamental transformation since its inception; at the beginning of the period it was almost exclusively based on small furnaces producing solid blooms and by the turn of the seventeenth century it was largely based on liquid-iron production in blast-furnaces the size of a house. One of the great advantages of studying the archaeology of ironworking is that its main residue, slag, is often produced in copious amounts both during smelting and smithing, is virtually indestructible and has very little secondary use. This means that most sites where ironworking was carried out are readily recognizable as such by the occurrence of this slag. Moreover, visual examination can distinguish between various types of slag, which are often characteristic for the activity from which they derive. The ubiquity of ironworking in the period under study further means that we have large amounts of residues available for study, allowing us to distinguish patterns both inside assemblages and between sites. Disadvantages of the nature of the remains related to ironworking include the poor preservation of the installations used, especially the furnaces, which were often built out of clay and located above ground. Added to this are the many parameters contributing to the formation of the above-mentioned slag, making its composition difficult to connect to a certain technology or activity. Ironworking technology in late medieval Ireland has thus far not been studied in detail. Much of the archaeological literature on the subject is still tainted by the erroneous attribution of the main type of slag, bun-shaped cakes, to smelting activities. The large-scale infrastructure works of the first decade of the twenty-first century have led to an exponential increase in the amount of sites available for study. At the same time, much of the material related to metalworking recovered during these boom-years was subjected to specialist analysis. This has led to a near-complete overhaul of our knowledge of early ironworking in Ireland. Although many of these new insights are quickly seeping into the general literature, no concise overviews on the current understanding of the early Irish ironworking technology have been published to date. The above then presented a unique opportunity to apply these new insights to the extensive body of archaeological data we now possess. The resulting archaeological information was supplemented with, and compared to, that contained in the historical sources relating to Ireland for the same period. This added insights into aspects of the industry often difficult to grasp solely through the archaeological sources, such as the people involved and the trade in iron. Additionally, overviews on several other topics, such as a new distribution map of Irish iron ores and a first analysis of the information on iron smelting and smithing in late medieval western Europe, were compiled to allow this new knowledge on late medieval Irish ironworking to be put into a wider context. Contrary to current views, it appears that it is not smelting technology which differentiates Irish ironworking from the rest of Europe in the late medieval period, but its smithing technology and organisation. The Irish iron-smelting furnaces are generally of the slag-tapping variety, like their other European counterparts. Smithing, on the other hand, is carried out at ground-level until at least the sixteenth century in Ireland, whereas waist-level hearths become the norm further afield from the fourteenth century onwards. Ceramic tuyeres continue to be used as bellows protectors, whereas these are unknown elsewhere on the continent. Moreover, the lack of market centres at different times in late medieval Ireland, led to the appearance of isolated rural forges, a type of site unencountered in other European countries during that period. When these market centres are present, they appear to be the settings where bloom smithing is carried out. In summary, the research below not only offered us the opportunity to give late medieval ironworking the place it deserves in the broader knowledge of Ireland's past, but it also provided both a base for future research within the discipline, as well as a research model applicable to different time periods, geographical areas and, perhaps, different industries..
Resumo:
The vibrated stone column technique is an economical and environmentally friendly process that treats weak ground to enable it to withstand low to moderate loading conditions. The performance of the treated ground depends on various parameters such as the strengths of the in-situ and backfill materials, and the spacing, length and diameter of the columns. In practice, vibrated stone columns are frequently used for settlement control. Studies have shown that columns can fail by bulging, bending, punching or shearing. These failure mechanisms are examined in this paper. The study involved a series of laboratory model tests on a consolidated clay bed. The tests were carried out using two different materials: (a) transparent material with ‘clay like’ properties, and (b) speswhite kaolin. The tests on the transparent material have, probably for the first time, permitted visual examination of deforming granular columns during loading. They have shown that bulging was significant in long columns, whereas punching was prominent in shorter columns. The presence of the columns also greatly improved the load-carrying capacity of the soft clay bed. However, columns longer than about six times their diameter did not lead to further increases in the load-carrying capacity. This suggests that there is an optimum column length for a given arrangement of stone columns beneath a rigid footing.
Resumo:
We used ground surveys to identify breeding habitat for Whimbrel (Numenius phaeopus) in the outer Mackenzie Delta, Northwest Territories, and to test the value of high-resolution IKONOS imagery for mapping additional breeding habitat in the Delta. During ground surveys, we found Whimbrel nests (n = 28) in extensive areas of wet-sedge low-centered polygon (LCP) habitat on two islands in the Delta (Taglu and Fish islands) in 2006 and 2007. Supervised classification using spectral analysis of IKONOS imagery successfully identified additional areas of wet-sedge habitat in the region. However, ground surveys to test this classification found that many areas of wet-sedge habitat had dense shrubs, no standing water, and/or lacked polygon structure and did not support breeding Whimbrel. Visual examination of the IKONOS imagery was necessary to determine which areas exhibited LCP structure. Much lower densities of nesting Whimbrel were also found in upland habitats near wetlands. We used habitat maps developed from a combination of methods, to perform scenario analyses to estimate the potential effects of the Mackenzie Gas Project on Whimbrel habitat. Assuming effective complete habitat loss within 20 m, 50 m, or 250 m of any infrastructure or pipeline, the currently proposed pipeline development would result in loss of 8%, 12%, or 30% of existing Whimbrel habitat. If subsidence were to occur, most Whimbrel habitat could become unsuitable. If the facility is developed, follow-up surveys will be required to test these models.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)